Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹60,120Accepted-Finance | 1 | Accepted-Finance Technical and financial bid are in order | |
| 2 | 2₹66,070+₹5,950 (9.90%)Accepted-Finance | 2 | Accepted-Finance Technical and financial bid are in order | |
| 3 | 3₹66,690+₹6,570 (10.9%)Accepted-Finance | 3 | Accepted-Finance Technical and financial bid are in order | |
| 4 | Rejected-Technical | - | Rejected-Technical Non submission of tender doucment |
Tender Value
₹72,540
Closing Date
6 May 2021, 3:00 pmClosed
EE, NACD, APWD, Mayabunder
EE, NACD, APWD, Mayabunder
Repair / Renovation of Agriculture Sub Depot at CFO Nallah under SAGY village Sub Division No.III, Swadeshnagar, NACD, APWD, Mayabunder. SW Providing IEI.
2021_APWD_2861_1
NIT NO.133/EE/NACD/2020-21
Open Tender
Electrical Works
Works
30 days
EE, NACD, APWD, Mayabunder
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
EE, NACD, APWD, Mayabunder
Exempted
11 May 2021
9 Apr 2021
7 May 2021
9 Apr 2021
6 May 2021
9 Apr 2021
Amount
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.
Group C
Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit alongwith 1 No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required.
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.
2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire
2 X 6 sq. mm + 1 X 6 sq. mm earth wire
Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.
5/6 A switch
3 pin 5/6 A socket outlet
Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.
Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required.
12 Module (200 mmX150 mm)
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 A & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required.
Supplying and fixing 3 pin, 5 A ceiling rose on the existing junction box/ wooden block including connections etc. as required.
Installation, testing and commissioning of wall bracket /ceiling fittings of all sizes and shapes containing upto two GLS/CFL/ LED lamps per fitting, complete with all accessories including connections etc. as required.
Installation, testing and commissioning of pre-wired, fluorescent fitting / compact fluorescent fitting of all types, complete with all accessories and tube/lamp etc. directly on ceiling/ wall, including connections with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. as required.
Installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length (upto 30 cm) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable etc. as required.
Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)
6 way, Double door
Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, “C” curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
Single pole
Supplying and fixing following rating, double pole, 240 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.
Earthing with G.I. earth pipe 4.5 meter long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required.
Providing and laying earth connection from earth electrode with 4.00 mm dia copper wire in 15 mm dia G.I. pipe from earth electrode including connection with copper thimble excavation and re-filling as required.
Providing and fixing 4.00 mm dia copper wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/ submain wiring/ cable as required.
Supplying of pre-wired surface mounted LED tube fittings similar to Crompton cat No.DMLN1LT8-16 with LED tube lamp similar to Crompton Cat No.LTT8-20 or its equivalent to ISI standard.
Supplying of AC Ceiling fan 1200 mm sweep similar to Bajaj KESSEL 50 ISI without regulator etc. or equivalent to ISI standard.
Supplying of LED Bulk Head fittings 10W LED 6000K equivalent to Havells ELLIPSE OVAL Cat No.LHEXCGP7PN5W010 etc. or its equivalent to ISI standard.
Providing and eraction of single phase metering box made out of SMC of overall size 310 x 285 x 180 with hinged cover and locking arrangements, viewing glass etc. as required similar to Sintex Model No. GSMB 2525.
KHODIAR DEVICES
AKABEA INFRASTRUCTURES PRIVATE LIMITED
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .