GE AF TUGHLAKABAD
GE AF TUGHLAKABAD SANGAM VIHAR PO NEW DELHI 110080
SPECIAL REPAIR TO COOLING APPLIANCE AT AF STN NAJAFGARH UNDER GE (AF) TUGHLAKABAD
2021_MES_444646_1
GE/TKD/TOKEN-03/2021-22
Open Tender
Civil Works - Others
Item Rate
180 days
GE AF TUGHLAKABAD
MES contractor enlisted as Class E or above category ci having deposited Standing Security of Rs. 50000 with dept. Contractors not enlisted in MES should meet the MES enlistment criteria corresponding to appropriate class and category
8 documents required · 8 mandatory
₹500
GE AF TUGHLAKABAD
₹29,000
Yes
29 Mar 2022
21 May 2021
19 Jun 2021
31 May 2021
17 Jun 2021
31 May 2021
Amount
Supply, installation, commissioing and testing of air conditioner window type single phase AC 230 Volt with minimum BEE 3 star rating with CFC refrigerant, 1.5 Tonne capacity including necessary intial gas charging, fixing arrangment, medium grade fixed to wall surface for condensed water outlet, electric connection, PVC insulated unsheathed aluminium conductor twin core cable of size 10 Sqmm form electric pole complete all as specified and directed by Engr-in-charge. Make: Cat No 18H CZP of Voltas/Cat No KAZE PLUS RAW318KUD of Hitachi/Cat No JW-Q18WUXA of LG
Supply, installation, commissioing and testing of high wall BEE 5 star air conditioner split type with outdoor unit and cordless remote control and with in built air ioniser and plasma filter for better indoor air quality with CFC refrigerant, 1.5 Tonne capacity complete, comprising of the following:- (a) Room evaporaive indoor unit with speed blower fan of appropriate capacity including PCB, thermostatic control, air filter and drain for condensing water. (b) Out door condensing unit of capacity 18000 BTU/Hr capacity with condenser fan motor of appropriate capacity - 01 No air cooled condenser of 1.5 TR capacity - 01 No shall be installed out side the building on and including suitable factory made mild steel brackets fixed on wall using fastners for fixing and installation of AC's. (c) Refrigerant copper pipe of suction and discharge line with insulation, condensing water drain pipe & protected by suitable size of flexible PVC conduit with control valves & safety accessories including control wiring for evaporator & condensing unit with suitable size of copper cable shall be fixed. (d) Making good the distrubed surface to match the existing surface after pluging the holes etc.
Contd sl item No 2.00 Note : (i) Cutting holes in walls/window of any thickness for installation of AC etc connection and making good the distrubed surface to match with the thickness for installation of AC etc, connection and unit rate quoted by contractor shall deemed to be inclusive of this aspect. (ii) Electrical cable of required size & length to connect outdoor unit with indoor unit and indoor unit to voltage stabliser is deemed to be included in the quoted rates of contractor. (iii) Copper piping/with insulations and drain piping shall be also deemed to be inclusive in quoted unit rate. Make: Cat No KS-Q18HNZD of LG/ Cat No Copper SAC_185V_ADS White of Voltas
Supply, installation, commissioing and testing of high wall BEE 5 star air conditioner split type with outdoor unit and cordless remote control and with in built air ioniser and plasma filter for better indoor air quality with CFC refrigerant, 2.0 Tonne capacity complete, comprising of the following:- (a) Room evaporaive indoor unit with speed blower fan of appropriate capacity including PCB, thermostatic control, air filter and drain for condensing water. (b) Out door condensing unit of capacity 18000 BTU/Hr capacity with condenser fan motor of appropriate capacity - 01 No air cooled condenser of 2.0 TR capacity - 01 No shall be installed out side the building on and including suitable factory made mild steel brackets fixed on wall using fastners for fixing and installation of AC's. (c) Refrigerant copper pipe of suction and discharge line with insulation, condensing water drain pipe & protected by suitable size of flexible PVC conduit with control valves & safety accessories including control wiring for evaporator & condensing unit with suitable size of copper cable shall be fixed. (d) Making good the distrubed surface to match the existing surface after pluging the holes etc.
Contd sl item No 3.00 Note: (i) Cutting holes in walls/window of any thickness for installation of AC etc connection and making good the distrubed surface to match with the thickness for installation of AC etc, connection and unit rate quoted by contractor shall deemed to be inclusive of this aspect. (ii) Electrical cable of required size & length to connect outdoor unit with indoor unit and indoor unit to voltage stabliser is deemed to be included in the quoted rates of contractor. (iii) Copper piping/with insulations and drain piping shall be also deemed to be inclusive in quoted unit rate. Make: Cat No Copper SAC_245V_ZZV White of Voltas/Cat No Alloy AC 2T GIC 24 MGP5-WRA Split 5S of Godrej
Supply, installation, commissioing and testing of desert cooler made out/body fabricated of 20 gauge MS sheet having a sump storage of 36 litre capacity of water with air flow of 4000 cum per hour, submersible type water lift pump of suitable capacity, fan with motor 450 mm sweep single phase AC 230 Volt and all necessary fittings such as front grill with tilting fins, control panel with switches including necessary fixing arrangement on window frames with 6 mm thick ply board of suitable size to cover the openings from all sides complete all as specified and directed by Engr-in-charge.
Supply, installation, commissioing and testing of desert cooler made out/body fabricated of 20 gauge MS sheet having a sump storage of 36 litre capacity of water with air flow of 5000 cum per hour, submersible type water lift pump of suitable capacity, fan with motor 450 mm sweep single phase AC 230 Volt and all necessary fittings such as front grill with tilting fins, control panel with switches including necessary fixing arrangement on window frames with 6 mm thick ply board of suitable size to cover the openings from all sides complete all as specified and directed by Engr-in-charge.
Supply and installed of water cooler electric driver of single phase AC 230 Volt having water storage capacity 80 litre and nominal cooling capacity of 40 litre per hour complete all as specified and directed by Engr-in-charge. Make: Cat No PC480 of Blue Star/Cat No SS4080 of Usha/Cat No 40/80 FSS/PSS 80L of Voltas
Supply and installed of Regrigerator BEE certified 5 star built in voltage stabiliser having nominal storage capacity 195 litre single phase AC 230 Volt double door type with himidity controller complete all as specified and directed by Engr-in-charge. Make: Cat No RR21T2H2W9R of Samsung/Cat No RD EDGEPRO 205E 53 TAI of Godrej/Cat No GL-D201ARGZ of LG
Supply and installed of Regrigerator BEE certified 3 star built in voltage stabiliser having nominal storage capacity 300 litre single phase AC 230 Volt double door type with himidity controller complete all as specified and directed by Engr-in-charge. Make: Cat No RT30N3753SL of Samsung/Cat No R T EON 311P 3.4 of Godrej/Cat No GL-T322RSPX of LG
Supply and fixing of 4 KVA voltage stabiliser for automatic operation single phase AC 230 Volt naturally air cooled indoor type and designed for input variation between 170 Volt to 250 Volt with output voltage 230 Volt with accuracy of +2.5% complete all as specified and directed by Engr-in-charge.
Supply and fixing of 5 KVA voltage stabiliser for automatic operation single phase AC 230 Volt naturally air cooled indoor type and designed for input variation between 170 Volt to 250 Volt with output voltage 230 Volt with accuracy of +2.5% complete all as specified and directed by Engr-in-charge.
Supply and fixing of 2 KVA voltage stabiliser for automatic operation single phase AC 230 Volt naturally air cooled indoor type and designed for input variation between 170 Volt to 250 Volt with output voltage 230 Volt with accuracy of +2.5% complete all as specified and directed by Engr-in-charge.
Taking down existing sub main wiring of any type and description including removal of teak wood batten/pipe, floors with using one coat of putty and two coats distemper on disturbed surface complete all as specified and directed by Engr-in-charge.
M&L for concealed sub main wiring complete with two runs of 6 Sqmm (nominal area) PVC insulated, multi stranded, FRLS copper conductor cable unsheathed drawn through and including 25mm dia PVC conduit with all fittings medium grade ISI Marked duly concealed by cutting chases and making good to match with surroundings including necessary periodicals applying one coat of putty and two coats of oil bound distemper along with PVC insulated FRLS copper conductor cable of size 4 Sq mm as earth wire, connected to common earth dolly complete all as specified and as directed by Engr-in-charge. Note: (i) The work includes cutting of chases and making good the disturbed surfaces and quoted rate deemed to be included the same aspect. (ii) One run of conduit with accessories, two runs of 6 Sq mm and one run of 4 Sq mm copper conductor will be measured as one unit of RM.
S&F in replacement sheet metal enclosure of two pin socket and chain plug cover type with 'C' series MCB single pole of 20 Amp breaking capacity 10 kA including electric connection complete all as specified and directed by Engr-in-charge.
Taking down/out from the existing position of split type AC's indoor & outdoor unit of capacity 1.5 / 2 TR, servicing the same by washing filters with soap solution jet followed by clean water, cleaning, drying, dusting with blower to complete assembly, checking wiring, replacement of air filter, worn out nuts, bolts, electric connections, tightening all loose parts for proper functioning, setting grills and fan blades including oiling, greasing/lubricating to moving parts and refixing to its original position and testing for smooth functioning complete all as specified and as directed by Engr-in-charge. Notes: (a) Entire work is to be carried out by the authorised technician of OEM only. (b) Cost of all T&P i.e. Blower, pressure pump, bucket, hose pipe etc is deemed to be included in the coated rates.
Disconnecting and taking down the unserviceable rotary compressor of the 1.5 ton split type air conditioner and S&F new rotary compressor, hermetically sealed including cutting, brazing, pressure testing and establishing vacuum for dehydration etc complete all as specified and as directed by Engr-in-charge
Disconnecting and taking down the unserviceable rotary compressor of the 2.0 ton split type air conditioner and S&F new rotary compressor, hermetically sealed including cutting, brazing, pressure testing and establishing vacuum for dehydration etc complete all as specified and as directed by Engr-in-charge
Supply and fixing in replacement Condenser unit for split AC of capacity 1.5 ton of any model, type, testing making all connections complete all as specified and directed by Engr-in-charge. Note: Necessary gas charging shall be measured and paid separately
Supply and fixing in replacement Condenser unit for split AC of capacity 2.0 ton of any model, type, testing making all connections complete all as specified and directed by Engr-in-charge. Note: Necessary gas charging shall be measured and paid separately
Checking leakage with soap solution of split type AC 1.5 / 2 TR of capacity by creating pressure with dry nitrogen gas complete all as specified and directed by Engr-in-charge.
Supply and charging R-22 refrigerant in split or window type AC 1.5 / 2 TR capacity / Refrigerator / Water cooler to make the system working complete all as specified and directed by Engr-in-charge. Note: Empty cylinder will be issued by the department on loan and as when required at site.
Supply, installation in replacement of copper tube of superior quality of dia 1/2" and minimum thickness 0.7 mm including necessary brazing, jointing, clamping/saddles and fix with walls with gitty or clamp complete all as specified and directed by Engr-in-charge.
Supply, installation in replacement of copper tube of superior quality of dia 3/8" and minimum thickness 0.7 mm including necessary brazing, jointing, clamping/saddles and fix with walls with gitty or clamp complete all as specified and directed by Engr-in-charge.
Supply, installation in replacement of copper tube of superior quality of dia 1/4" and minimum thickness 0.7 mm including necessary brazing, jointing, clamping/saddles and fix with walls with gitty or clamp complete all as specified and directed by Engr-in-charge.
Supply, fixing and testing in replacement with new electronic card/PCB of existing window or split type AC of capacity 1.5/2.0 TR complete all as specified and directed by Engr-in-charge.
Supply, fixing and testing in replacement with running or starting capacitor of 3.15/4.0/6.0 mfd capacity in cooling appliances complete all as specified and directed by Engr-in-charge.
Supply, fixing and testing in replacement with running or starting capacitor of 36 mfd capacity 6 Pin in cooling appliances complete all as specified and directed by Engr-in-charge.
Supply, fixing and testing in replacement with running or starting capacitor of 45 mfd capacity 6 Pin in cooling appliances complete all as specified and directed by Engr-in-charge.
Supply, fixing and testing in replacement with running or starting capacitor of 50 mfd capacity 6 Pin in cooling appliances complete all as specified and directed by Engr-in-charge.
S&F in replacement of 6 Amp plug top, 3 Pin 230 Volt and testing complete all as specified and directed by Engr-in-charge.
S&F in replacement of wood wool pad heavy duty of suitable size for desert cooler of any make or capacity including mounting arrangements complete all as specified and directed by Engr-in-charge.
S&F in replacement of fan motor copper wound single phase 230 Volt, 1440 RPM for deser cooler of any make or capacity including mouting arrangements complete all as specified and directed by Engr-in-charge.
Supply, fixing and testing in replacement of 18/20 Watt water pump with discharge head of 1.87 metre single phase 230 Volt, 1440 RPM for deser cooler of any make or capacity including mouting arrangements complete all as specified and directed by Engr-in-charge.
M&L for preparing the surfaces by scrapping out the old paint and painting with two coats of synthetic enamel paint inside & outside surface and applying two coats of rubber seal paint inside the water tank of desert cooler capacity upto 5000 cum per hour by spray painting including rewriting the MES/SM NO complete all as specified and directed by Engr-in-charge.
Supply, fixing and testing in replacement for PVC insulated cable of 3 core 1.5 Sq mm, FRLS 1100 Volts grade copper conductor, multistranded including testing complete all as specified and directed by Engr-in-charge.
Supply & fixing in replacement of old rusted front panel with show grill of desert cooler capacity 4000/5000 cum/hr with new grill made out of GI sheet 22 SWG complete with front panel and replacement of complete rusted cooler body, unserviceable fan motor of capacity 230 V and unserviceable water Pump of capacity 18/20 Watt & four speed regulator of approved make all as specified and as directed by Engr-in-Charge.
Supply and fixing in replacement of fan blade made of GI sheet of heavy duty for the desert cooler for any capacity complete all as specified and as directed by Engr-in-charge.
Supply and fixing in replacement PVC flexible rubber heavy duty pipe 15 mm dia for desert coolers complete all as specified and directed by Engr-in-charge.
Supply and fixing in replacement PVC water distributor four way along with necessary PVC elbows threaded suitable for insertion in PVC pipe 15 mm dia for desert coolers complete all as specified and directed by Engr-in-charge.
Notes: The amount of Rs 9,850/- against schedule of credit given on Tender Serial Page No 32 shall be deducted from the total amount quoted by the contractor against BOQ while deriving the contract sum for acceptance.
DP Traders
PARKASH ENTERPRISES
M/S S.K.Electricals
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .