Loading…
Loading…
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance | Admitted-Finance |
| 2 | Not Admitted-Fee/PreQual/Technical | Not Admitted-Fee/PreQual/Technical No EMD or Fee received |
Tender Value
₹62 L
EMD Value
₹1.2 L
Closing Date
19 Feb 2024, 11:00 amClosed
SE Civil RVPN Jaipur
Chambal Power house, Hawa sadak , Sodala, Jaipur
Const. of foundation and civil work for shifting of part of existing 33KV switchyard at 220 KV GSS NPH to new location due to settlement of soil at old location as augmentation work.
2024_RRVPN_379730_1
RVPN/SE/CIVIL/NIT 25/01
Open Tender
Civil Works
Percentage
270 days
220 KV GSS NPH Jaipur
Please refer Tender documents.
2 documents required · 2 mandatory
₹2,360
Accounts officer T and C RVPNL Jaipur city
₹1.2 L
Yes
23 Feb 2024
6 Feb 2024
20 Feb 2024
6 Feb 2024
19 Feb 2024
6 Feb 2024
Amount
Labour charge for spreading of available 20 to 63 mm nominal size hand/ crusher broken stone aggregate in uniform layer 100 mm thickness in yard of any substation (charged/ uncharged GSS) with manual/ Mechanical means, as permitted by engineer in charge with due care as per safety norms of substation, complete in all respect with all lead and lift. (payment shall be done as stack measurment after deduction of voids, as per norms.)
Supply & Fixing 30mm thick ferro cement RCC cable trench covers up to span 1200mm C:C grade M-25 (1 Cement : 1 course sand :2 graded store aggregate 20mm nominal size) having outer frame of M.S. flat 30x3 mm and reinforcement consisting of 6mm dia M.S.round bar both way at the spacing of 8 to 10 cm C/C as required to adjust the spacing welded with outer frame and binding with bibding wire in middle with two layers of G.I. wire mesh 12mm shape of 24 gauge including proper quantities of concrete additional admixture like plasticizer, bond improving compound etc. manufacture with vibro pressing system , 20% cover shall have lifting hooks of 10mm dia plain round bar to be fixed as directed. M.S. flat/hooks exposed shall be painted with two coats of superior quality corrosion resistance paint. tThe above covers shall to take for live load of 2000 KG/sqm and minimum ultimate load of 3000 Kg/sqm under defection not exceeding L/25.
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .