Loading…
Loading…
Tender Value
₹29.1 L
EMD Value
₹58,220
Closing Date
17 Aug 2026, 6:00 pm
Maj R S Kalkat
GARRISON ENGINEER 867 EWS
RAPAIR MAINT REPLACEMENT OF OLD U S CI GI PIPE LINE PUMP SLUICE VALVE GATE VALVE VALVE CHAMBER CLEANING OF UG SUMP AND SERVICE TANK AND MISC ALLIED WORKS AT AP ALGARAH DALAPCHAND AND TEESTA TCP PEDONG ALGARAH UNDER GE 867 EWS
2026_MES_781074_1
8638/E8
Open Tender
Civil Works
Item Rate
180 days
PEDONG
AS PER NIT
8 documents required · 8 mandatory
₹500
GE 867 EWS
₹58,220
Yes
27 Jul 2026
27 Jul 2026
19 Aug 2026
27 Jul 2026
17 Aug 2026
10 Aug 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | M&L for Cleaning of semi under ground water sumps of 50000 Glns capacity by removing residual/balance water, taking out solid residual loose dirt, scales, mud, fungus, vegetation growth, scrubbing the complete inner surface of wall and floor with wire brushes and cleaning with water and again cleaning and washing completely using bleaching powder and fresh water, drying the entire surface and applying two coats of lime wash internally and writing the date of cleaning on external surfaces with thick synthetic enamel paint in bold Capital letters (not exceeding 15 cm high) once in six month complete all as directed by the Engineer-in-Charge. | 3 | Each Job | - | - |
| 2 | M&L for Cleaning of semi under ground water sumps of 35000 Glns capacity by removing residual/balance water, taking out solid residual loose dirt, scales, mud, fungus, vegetation growth, scrubbing the complete inner surface of wall and floor with wire brushes and cleaning with water and again cleaning and washing completely using bleaching powder and fresh water, drying the entire surface and applying two coats of lime wash internally and writing the date of cleaning on external surfaces with thick synthetic enamel paint in bold Capital letters (not exceeding 15 cm high) once in six month complete all as directed by the Engineer-in-Charge. | 2 | Each Job | - | - |
| 3 | M&L for Cleaning of semi under ground water sumps of 10000 Glns capacity by removing residual/balance water, taking out solid residual loose dirt, scales, mud, fungus, vegetation growth, scrubbing the complete inner surface of wall and floor with wire brushes and cleaning with water and again cleaning and washing completely using bleaching powder and fresh water, drying the entire surface and applying two coats of lime wash internally and writing the date of cleaning on external surfaces with thick synthetic enamel paint in bold Capital letters (not exceeding 15 cm high) once in six month complete all as directed by the Engineer-in-Charge. | 3 | Each Job | - | - |
| 4 | M&L for disconnecting existing PVC water tanks of capacity 2000 ltrs, setting aside (or lowering if requried) cleaning and removing all scale & dirt etc., from tanks and mouths of circulating pipes etc., by using bleaching powder and writing/marking MES Number and date of cleaning on external surfaces with thick synthetic enamel paint in bold Capital letters (not exceeding 15 cm high) and hoisting if requried, re-connecting and re-fixing in position complete all as specified and directed by the Engineer-in-Charge. | 38 | Each | - | - |
| 5 | M&L for disconnecting existing PVC water tanks of capacity 1000 ltrs, setting aside (or lowering if requried) cleaning and removing all scale & dirt etc., from tanks and mouths of circulating pipes etc., by using bleaching powder and writing/marking MES Number and date of cleaning on external surfaces with thick synthetic enamel paint in bold Capital letters (not exceeding 15 cm high) and hoisting if requried, re-connecting and re-fixing in position complete all as specified and directed by the Engineer-in-Charge. | 33 | Each | - | - |
| 6 | M&L for disconnecting existing PVC water tanks of capacity 500 ltrs, setting aside (or lowering if requried) cleaning and removing all scale & dirt etc., from tanks and mouths of circulating pipes etc., by using bleaching powder and writing/marking MES Number and date of cleaning on external surfaces with thick synthetic enamel paint in bold Capital letters (not exceeding 15 cm high) and hoisting if requried, re-connecting and re-fixing in position complete all as specified and directed by the Engineer-in-Charge. | 20 | Each | - | - |
| 7 | M&L for construction of Valve chamber of internal dimension/size 600 x 600 x 600 mm, with 200mm thick pre-cast PCC solid block masonry (made of PCC (1:3:6) type C-1 : using 20mm graded crushed stone aggregate) wall in cement mortar (1:6), with 1.6 mm thick MS sheet cover, fixed with 25x25x6 mm stiffner welded around, welded over angle iron frame of size 65 x 65 x 6 mm with locking arrangements including applying two coats of first grade synthetic enamel paint (of approved tint) over a coat of red oxide primer on steel surfaces, necessary earth work in soft/loose soil with and including 100 mm thick PCC (1:3:6) Type C-2 (using 40mm graded stone aggregete) as in foundation, 50 mm thick PCC (1:2:4),Type B-1 (using 20mm graded stone agregate) as in coping on top including rendering 10mm thick in cement mortar (1:6), finished even and fair and applying three coats of white wash on exposed surfaces, complete including demolition of existing unserviceable valve chamer complete all as specified and directed by the Engineer-in-Charge. (The chamber shall be 150 mm above the ground level). | 1 | Each | - | - |
| 8 | M&L for construction of Valve chamber of internal dimension/size 900 x 900 x 900 mm, with 200mm thick pre-cast PCC solid block masonry (made of PCC (1:3:6) type C-1 : using 20mm graded crushed stone aggregate) wall in cement mortar (1:6), with 1.6 mm thick MS sheet cover, fixed with 25x25x6 mm stiffner welded around, welded over angle iron frame of size 65 x 65 x 6 mm with locking arrangements including applying two coats of first grade synthetic enamel paint (of approved tint) over a coat of red oxide primer on steel surfaces, necessary earth work in soft/loose soil with and including 100 mm thick PCC (1:3:6) Type C-2 (using 40mm graded stone aggregete) as in foundation, 50 mm thick PCC (1:2:4),Type B-1 (using 20mm graded stone agregate) as in coping on top including rendering 10mm thick in cement mortar (1:6), finished even and fair and applying three coats of white wash on exposed surfaces, complete including demolition of existing unserviceable valve chamer complete all as specified and directed by the Engineer-in-Charge. (The chamber shall be 150 mm above the ground level). | 2 | Each | - | - |
| 9 | S&F in repair gun metal, globe or gate valve 50mm bore dia., with iron wheel head, screwed both ends for iron pipes and fixed complete all as specified and directed. | 4 | Each | - | - |
| 10 | S&F in repair gun metal, globe or gate valve 40mm bore dia., with iron wheel head, screwed both ends for iron pipes and fixed complete all as specified and directed. | 6 | Each | - | - |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.18 MB
Tender.pdf
Tender Documents • 1.09 MB
BOQ_874977.xls
BOQ • 0.33 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at [email protected].