Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹29.6 LAccepted-AOC 13 218 MASJID EXTEN SADAR BAZAR | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹36.8 L+₹7.0 L (23.4%)Rejected-Finance | L2 | Rejected-Finance Not being lowest tenderer | |
| 3 | L3₹39.9 L+₹10.1 L (33.7%)Rejected-Finance NIVADA TIVAYA ROAD TIVYA MUST BUS STOP VILLAGE KHATAULI SAHARANPUR UP 247001 | SAHARANPUR | SAHARANPUR | UP | 247001 | L3 | Rejected-Finance Not being lowest tenderer | |
| 4 | L4₹40.4 L+₹10.5 L (35.4%)Rejected-Finance | L4 | Rejected-Finance Not being lowest tenderer | |
| 5 | L5₹47.6 L+₹17.8 L (59.8%)Rejected-Finance | L5 | Rejected-Finance Not being lowest tenderer |
Tender Value
₹49.5 L
EMD Value
₹99,000
Closing Date
18 Jan 2022, 6:00 pmClosed
Garrison Engineer South Delhi Cantt 110010
Delhi Cantt 110010
REPAIR/ REPLACEMENT OF CONVENTIONAL LIGHTS WITH LED FITTING OF 341 DUS AND CONNECTED E/M NATURE OF WORK AT TARAPORE OFFRS ENCLAVE AND REPAIR/ REPLACEMENT OF LT OVERHEAD LINES ELECTRIC POLES TRANSFORMER EATHING SECURITY LIGHTS FLOOD LIGHTS JUNCTION BO
2021_MES_496500_1
GE/DS-77/2021-22
Open Tender
Civil Works
Item Rate
270 days
Garrison Engineer South Delhi Cantt 110010
Please refer Tender documents.
10 documents required · 10 mandatory
₹500
Garrison Engineer South Delhi Cantt 110010
₹99,000
Yes
14 Mar 2022
21 Dec 2021
20 Jan 2022
21 Dec 2021
18 Jan 2022
4 Jan 2022
22 Dec 2021 - 1 Jan 2022
Amount
Taking down carefully old unservicable copper/ Aluminium point wiring (light, fan, socket or power) complete fitting such as switches, ceiling roses, holder pandants, sockets regulators, bell push etc) and making good disturbed surfaces of walls including necessary touch up with the adjoining surfaces of disturbed area i.e. with OBD/colour wash/white wash as the existing finish complete all as specified and directed by Engineer-in-charge.
M&L for point wiring complete, stranded copper conductor 1.5 Sqmm nominal area PVC insulated FRLS 1100 volts grade electrical cable in but with through existing concealed PVC/ MS conduit and including replacement of modular sunken pressed steel terminal boxes 2mm thick of required size and modular white cover plate with all accessories including 1.5 sqmm stranded copper conductor PVC unsheathed cable earth wire to common earth and connected to earth dolly complete and making good to disturbed surface of walls including necessary touch up with adjoining surface of disturbed area i.e with OBD/colour work/white wash as existing finishes complete all as specified and directed by Engineer-in-charge. Note :- In existing conduit wiring new conduit will be added where there is a burnt/blokage/damage to the existing conduit including bends/elbows/tees/Junction boxes.
All as per item No 2 above but one 3 pin 5 Amps socket outlet point controlled by one No one way modular switch and modular socket on independent board.
All as per item No 2 above but one 3 pin 5 Amps socket outlet point controlled by one No one way modular switch and modular socket on same board.
All as Item No 2 above but point wiring for 16 Amps for modular socket point with 2.5 Sqmm single core copper cable and earth continuity wire with 2.5 Sqmm single core cable for one three pin 15 Amps modular switch/socket outlet point on independent board.
All as Item No 2 above but for one One light controlled by 2-way switches using cable of 1.5 Sq mm for phase and neutral and 1.5 sqmm for earthing.
All as Item No 2 above but for one AC point controlled by using cable of 4 Sq mm for phase and neutral and 4 sqmm for earthing.
S&F Switch modular type, 1Module, 6 Amps one way as per sample complete all as specified and directed by Engineer-in-charge.
S&F Switch modular type 1M 6 Amp 2-way as per sample complete all as specified and directed by Engineer-in-charge.
S&F Bell push modular type 1M 5/6 Amp as per sample complete all as specified and directed by Engineer-in-charge.
S&F Socket outlet modular type 2M, 2/3 pin, 6 Amp as per sample complete all as specified and directed by Engineer-in-charge.
S&F Switch modular type 1M, 16 Amp as per sample complete all as specified and directed by Engineer-in-charge.
S&F Socket Outlet modular type 2M combined shuttered, 5 pin 6/16 Amp as per sample complete all as specified and directed by Engineer-in-charge.
S&F Electronic fan regulator, modular type 2M, 4 steps, as per sample complete all as specified and directed by Engineer-in-charge.
S&F in replacement Modular box with MCB 20 Amp complete with metal box and 3 Pin top plug as per sample complete all as specified and directed by Engineer-in-charge. Note : Rates are inclusive of cutting / chases for mounting modular metal box concealed in wall and making good to disturbed surfaces with OBD / Colour wash / white wash and wall putty where ever required.
S&F lamp holder Angle type bakelite insulated body with back plate suitable for batten fitting as per sample complete all as specified and directed by Engineer-in-charge.
S&F Electric Bell (Buzzer) AC, 230 volts single phase as per sample complete all as specified and directed by Engineer-in-charge.
S&F in replacement of old unserviceable plug top metal type 15/16 Amps for Geyser as per sample, complete all as specified and directed by Engineer-in-charge.
S&F ceiling rose surface Bakelite 65x25 mm two to three terminals as per sample complete all as specified and directed by Engineer-in-charge.
S&F in replacement of 32 Amp SPN rating 240V, 10KA 'C' curve miniature circuit breaker (MCB) as per sample complete all as specified and directed by Engineer-in-charge.
S&F in replacement of 5 to 32 Amp SP rating 240V, 10KA 'C' curve miniature circuit breaker (MCB) as per sample complete with connection testing and commissioning complete all as specified and directed by Engineer-in-charge.
S&F in replacement of single phase inducation motor AC 230V, 1300 RPM copper wounded suitable for fresh air fan 200mm sweep as per sample, complete all as specified and directed by Engineer-in-charge.
S&F in replacement of single phase inducation motor AC 230V, 1350 RPM copper wounded suitable for fresh air fan 300mm sweep as per sample, complete all as specified and directed by Engineer-in-charge.
M&L for Rewinding of ceiling fan 1200/1400 mm sweep by dismantling of fan motor cutting and removing of burnt windings, cleaning, winding with supper enameled copper wire of superior quality, same gauge of wire, same Nos of turns, provn of insulation paper applying of varnish drying of varnish and assembling of fan including replacement gun metal bush and Shaft where ever required complete all as specified and directed by Engineer-in-charge.
S&F in replacement of 415V DB 8 way TPN single door as per sample complete all as specified and directed by Engineer-in-charge.
S&F in replacement of MCB TPN 63 Amps 415V 10KA 'C' curve as per sample complete with connection testing and commissioning complete all as specified and directed by Engineer-in-charge.
S&F in replacement Gaskets of Collector as per site requirement complete all as specified and directed by Engineer-in-charge.
S&F in replacement Dead plug of Collector as per site requirement complete all as specified and directed by Engineer-in-charge.
S&F in replacement SS-304 Nuts and bolts 6 x 25 mm size all as per site requirement complete all as specified and directed by Engineer-in-charge.
S&F Hose pipe 25mm dia with adjustable clamp heavy duty/nut/bolts etc laid in trenches fixed to wall, ceilings and floor for hot water as per sample complete all as specified and directed by Engineer-in-charge.
S&F in replacement thermostat ( 9/11 inch Long) for 25 ltrs capacity geysers as per sample complete all as specified and directed by Engineer-in-charge.
S&F in replacement heating element 1.5 KW for any make of geyser of 25 litres capacity as per sample as per sample complete all as specified and directed by Engineer-in-charge.
S&F in replacement indicating lamp round / flat type for geyser 25 litres capacity as per sample complete all as specified and directed by Engineer-in-charge.
S&F in repairs Rotational moulded polyethylene water storage tanks of 1000 ltr capacity (cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Part I alongwith all fittings for connection inlet/outlet complete all as specified and directed by Engineer-in-charge.
Earthing complete with galvanized steel earth plate electrode 60 cm x 60 cm x 6 mm thick buried directly in ground (earth pit not less than 2.25 metres deep below normal ground level) with top edge of plate not less than 1.5 metres below normal ground level, connecting to the Galvanised earth lead wire 4.0 mm dia by means of bolts, nuts , check nuts and washers of galvanized iron and steel earth wire protected by provision of GI light grade pipe 40 mm bore including provision of concrete pit made from PCC ( 1:2:4) type B-1 (using 20 mm graded stone aggregate) with 40mm thick cover of RCC 1:2:4 reinforced with XPM (Weight not less than 4 Kg/Sqm) and frame of angle iron 40 x 40 x 6 mm and handle of 6 mm dia MS bar made to shape, GI light grade 20 mm bore pipe for watering perforated at bottom, 1.50 metre long placed on top edge of earth plate, common salt & charcoal filling, with fixing arrangement , funnel, wire mesh and earth work in hard/dense soil , returning filling in and removal of surplus soil to a distance not exceeding 50 metres, all as per electrical plate No 5 of SSR 2009 Part-I and connecting to Poles all as specified or indicated including testing on complete all as specified and directed by Engineer-in-charge.
M&L for sub main wiring using single run PVC FRLS grade insulated unsheathed, multistrand copper conductor cable 4 runs of 10 Sqmm for Phase and neutral and 1 run of 10 sqmm for earth wire drawn through existing size of PVC concealed conduit and including replacement of unsv pressed steel terminal boxex of in wall as per suitalbe/existing dia with fittings like tees, bends junction/terminal boxex etc as per site requirement complete all as specified and directed by Engineer-in-charge. Note :- Phase should be Red/Yellow/Blue, neutral should be black and earthing wire should be of green colour. Five runs of cable for 3 phase neutral and for earth will be measured and paid as one unit length) and making good a disturbed surface
S&F in replacement Wall mounted LED Integrated aluminium Battern luminaire polycarbonate co-extrusion tube for 20W LED light housing with engg-plastic end caps Co-extrusion tube top part is made of Polycarbonate material and the diffuser is made of opal polycarbonate mateial with groove inside of PCB complete with including flexible wire complete all as specified and directed by Engineer-in-charge.
S&F in replacement Surface mounting round shaped LED downlighter with durable housing with Al heat shrink with diffuser to give glare free light 12 Watt LED 6000K/6500K lamp type from ceiling of stairs/common areas, complete all as specified and directed by Engineer-in-charge.
S&F LED bulk head in engineering plastic housing with clear prismatic diffuser, 10W WHITE in replacement of old unsv bulk head fitting including all accessories connecting up twin core flexible copper conductor cable complete all as specified and directed by Engineer-in-charge.
S&F in repairs ,Decorative wall light mounting alongwith LED Lamp upto 15 Watt with all connections complete all as specified and directed by Engineer-in-charge. .
M&L for spray painting of Transformer (including bringing compressor of suitable size at site) old painted steel or iron surface of 100 to 400 KVA transformer (11/0.433KV) complete with all connected fittings & fixtures i.e. buchholz relay, conservator tank, cooling fins and other standard fittings & attachments as per existing colour scheme and pattern with atleast one coats of synthetic enameled paint over two coats of red oxide primer after duly preparing the surface by cleaning with scrapers and emrey paper to the entire satisfaction complete all as specified and directed by Engineer-in-charge. Note:- Contractor will apply one layer of greese over specification plate / any written letter before painting and clean the same after painting, rates for the same is deemed to be included in the item quoted rates.
M&L for cross arms, bracings, supports, channel,clamps and back plates fabricated from steel section including nuts, bolts, washers, welding bending cold or hot drilling holes for bolts in any shape or size as indicated or directed and inclusive of one primer coat, one under coat and one finishing coat of paint complete including taking out existing supports of wooden pieces for holding overhead conductor complete all as specified and directed by Engineer-in-charge.
Dismantling burnt / defective Gang Operated Switch keeping away from site , Supply & install 11 KV 3 Phase Gang operated air break switch with drop out fuses set ( consisting 12 Nos Post Insulator ) 400 amp capacity, vertical mounting with fixed and moving contacts complete with locking arrangement and fixing the gang operated switch on existing two/four pole structure including making all jumper connections with insulated leads of suitable size with line tops etc, complete all as specified and directed by Engineer-in-charge.
S&F in replacement of lightening arrestor explusion type complete with all fittings, transmission class, discharge capacity 65kA and suitable for working voltage 11000 volts complete all as specified and directed by Engineer-in-charge.
S&F in repairs for danger notice plate of 1.6mm thick mild steel sheet, vitreous enamelled white, with letters, figures and conventional skull and bones in signal red colour and fixed with & including M.S. clamps, bolts and nuts of approved size, for LT of 20x15cm size complete all as specified and directed by Engineer-in-charge.
S&F in repair for danger notice plate of 1.6mm thick mild steel sheet, vitreous enamelled white, with letters, figures and conventional skull and bones in signal red colour and fixed with & including M.S. clamps, bolts and nuts of approved size, for HT of 25x20cm size complete all as specified and directed by Engineer-in-charge.
Cleaning, preparing and painting with one coat of super enamalled aluminium paint over two coats of red oxide primer to cross arms, MS channels, angle iron, frame work, on pre-stressed HT concrete 2 pole/4 pole structure complete all as specified and directed by Engineer-in-charge.
Earthing complete with galvanized steel earth plate electrode 60 cm x 60 cm x 6 mm thick buried directly in ground (earth pit not less than 2.25 metres deep below normal ground level) with top edge of plate not less than 1.5 metres below normal ground level, connecting to the Galvanised iron strip 25x4 mm by means of bolts, nuts , check nuts and washers of galvanized iron and steel earth wire protected by provision of GI light grade pipe 40 mm bore including provision of concrete pit made from PCC ( 1:2:4) type B-1 (using 20 mm graded stone aggregate) with 40mm thick cover of RCC 1:2:4 reinforced with XPM (Weight not less than 4 Kg/Sqm) and frame of angle iron 40 x 40 x 6 mm and handle of 6 mm dia MS bar made to shape, GI light grade 20 mm bore pipe for watering perforated at bottom, 1.50 metre long placed on top edge of earth plate, common salt & charcoal filling, with fixing arrangement , funnel, wire mesh and earth work in hard/dense soil , returning filling in and removal of surplus soil to a distance not exceeding 50 metres, all as per electrical plate No 5 of SSR 2009 Part-I and connecting to Transformer / Poles all as specified or indicated including testing on complete all as specified and directed by Engineer-in-charge.
Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing/connecting as required 25x4 mm galvanised iron strip complete all as specified and directed by Engineer-in-charge.
M&L for test point terminal block made of gun metal or phosphorus bronze size gun metal or phosphorus bronze size 75 X 75 X 25 mm, drilled and screwed including 3 nos. 8mm dia 25 mm long hex. Head screw complete all as specified and directed by Engineer-in-charge.
S&F in repairs for synthetic insulating mat of size 2m x 1m x 12 mm complete all as specified and directed by Engineer-in-charge.
Supply & toping up of new transformer oil (in sealed barrel) having dielectric strength 40KV at 2.5mm gap after initial dehydration complete all as specified and directed by Engineer-in-charge.
M&L for dehydration & filteration of transformer oil by dehydration plant (bringing plant at site) including testing of sample before and after dehydration and filteration to achieved 40 KV at 2.5 mm gap complete all as specified and directed by Engineer-in-charge.
S&F in replacement of oil temperature/winding temperature indicator suitable for transformer of capacity 100 to 400 KVA all as per existing and having level marking complete all as specified and directed by Engineer-in-charge.
S&F in replacement of air breather complete with new silca GEL suitable for 11/0.433 KV, 100 to 400 KVA capacity transformer complete all as specified and directed by Engineer-in-charge.
Taking down transformer 11/0.433 KV, 100 to 400 KVA of any make disconnecting all the electrical connections from HT & LT side and earthing of unserviceable transformer, from platform /four pole structure, draining out the transformer oil in clean barrels, loading and unloading of transformer & transportation by suitable vehicle from substation to the workshop for rewinding/reconditioning or any other repair required, reassembling making the internal HT & LT connections by fixing the studs, bushings, fitting the top cover by replacing cork sheet including gasket along with conservator including hoisting placing in position and securing properly on platform/pole structure at site, including pouring the transformer oil in the transformer, re-installation and commissioning complete all as specified and directed by Engineer-in-charge. Note: Unserviceable items required for repairing shall be measured and paid separately.
M&L for opening of top cover of transformer 11/0.433 KV, 100 to 400 KVA of any make for repairing/leakage removal after disconnecting the HT/LT side connections, draining out transformer oil keeping in safe custody in a dry and clean container, taking out top cover, oil conservator, explosion vent with & including replacement of complete gasket set for top cover, oil conservator, explosion vent, HT/LT side bushing valve including replacement of worn out nuts, bolts and washers, re-assembling and refilling of transformer oil, making connections on HT/LT side complete all as specified and directed by Engr-in-charge and directed by Engr-in-Charge. Note: Major unserviceable items like bushing/winding/new oil shall be measured and paid seperately.
M&L for re-winding of HT coils of 11/0.433 KV, 400 to 200 KVA transformer of any make with superior quality super enamelled copper winding wire/strip of approved make of suitable gauge and number of turns alongwith allied materials such as cork sheet, fibre glass, insulation paper, isulation cotton, empire tape and wooden blocks, bolts, nuts and washers, soldering and other packing materials including taking out of existing unserviceable coils complete all as specified and directed by Engineer-in-charge.
M&L for re-winding of LT coils of 11/0.433 KV, 400 to 200 KVA transformer of any make with superior quality super enamelled copper winding wire/strip of approved make of suitable gauge and number of turns alongwith allied materials such as cork sheet, fibre glass, insulation paper, isulation cotton, empire tape and wooden blocks, bolts, nuts and washers, soldering and other packing materials including taking out of existing unserviceable coils complete all as specified and directed by Engineer-in-charge.
M&L for heat treatment at the workshop furnance of complete core before and after re-assembly of coil into limps after rewinding for transformer capacity 400 to 200 KVA, 11/0.433 KV complete all as specified and directed by Engineer-in-charge.
S&F in replacement of HT bushing, 11000 volts, 50 Hz suitable for transformer 11/0.433 KV, 250 to 400 KVA capacity of any make complete all as specified and directed by Engineer-in-charge.
S&F in replacement of HT bushing, 11000 volts, 50 Hz suitable for transformer 11/0.433 KV, 100 to 200 KVA capacity of any make complete all as specified and directed by Engineer-in-charge.
S&F in replacement of LT bushing, 1100 volts, 50 Hz suitable for transformer 11/0.433 KV, 250 to 400 KVA capacity of any make complete all as specified and directed by Engr-in-charge.
S&F in replacement of LT bushing, 1100 volts, 50 Hz suitable for transformer 11/0.433 KV, 100 to 200 KVA capacity of any make complete all as specified and directed by Engineer-in-charge.
S&F in replacement of HT brass stem, 11000 volts, 50 Hz suitable for transformer 11/0.433 KV, 250 to 400 KVA capacity of any make complete with one chuck nut, two nuts, washers and rubber seal complete all as specified and directed by Engineer-in-charge.
S&F in replacement of HT brass stem, 11000 volts, 50 Hz suitable for transformer 11/0.433 KV, 100 to 200 KVA capacity of any make complete with one chuck nut, two nuts, washers and rubber seal complete all as specified and directed by Engineer-in-charge.
S&F in replacement of LT brass stem, 1100 volts, 50 Hz suitable for transformer 11/0.433 KV, 250 to 400 KVA capacity of any make complete with one chuck nut, two nuts, washers and rubber seal complete all as specified and directed by Engineer-in-charge.
S&F in replacement of LT brass stem, 1100 volts, 50 Hz suitable for transformer 11/0.433 KV, 100 to 200 KVA capacity of any make complete with one chuck nut, two nuts, washers and rubber seal complete all as specified and directed by Engineer-in-charge.
Taking out serviceable/unserviceable vacuum circuit breaker (VCB) of capacity 400/630 Amps, 11 KV of any make from HT panel for repairing/servicing, opening all covers/strips, cleaning, servicing & lubricating, internally & externally all contacts, springs, motor charging mechanism, tripping system including adjustment, tightening & setting of all contacts & inserting it in its original position, re-assembling all parts and fixing in its panel for smooth functioning of the circuit breaker to the entire satisfaction complete all as specified and directed by Engineer-in-charge. Note:- Unserviceable parts required to make breaker serviceable shall be measured and paid separately under respective items.
S&F in replacement of tripping push button as per sample suitable for VCB/OCB11 KV complete all as specified and directed by Engineer-in-charge.
S&F in replacement of closing coil assembly suitable for VCB 11 KV complete all as specified and directed by Engineer-in-charge.
S&F in replacement of tripping coil assembly suitable for VCB 11 KV complete all as specified and directed by Engineer-in-charge.
S&F in replacement of earth contact assembly suitable for VCB 11 KV complete all as specified and directed by Engineer-in-charge.
S&F in replacement of spring charging mechanism suitable for VCB 11 KV complete all as specified and directed by Engineer-in-charge.
S&F in replacement of spring charged indicator suitable for VCB 11 KV complete all as specified and directed by Engineer-in-charge.
S&F in replacement of ON/OFF indicator suitable for VCB/OCB 11 KV complete all as specified and directed by Engineer-in-charge.
S&F in replacement of auxiliary switch suitable for VCB 11 KV complete all as specified and directed by Engineer-in-charge.
S&F in replacement of vaccum interreputer bottle 400/630 Amps, 11KV per phase suitable for VCB complete all as specified and directed by Engineer-in-charge.
S&F in replacement of moving contact assembly suitable for VCB 11 KV complete all as specified and directed by Engineer-in-charge.
S&F in replacement of fixed contact assembly suitable for VCB 11 KV complete all as specified and directed by Engineer-in-charge.
S&F in replacement of motor & gear assembly for spring charging suitable for VCB 11 KV complete all as specified and directed by Engineer-in-charge.
S&F in replacement of main shaft inter lock assembly suitable for VCB 11 KV complete all as specified and directed by Engineer-in-charge.
S&F in replacement of power pack unit suitable for 230 volts, 50 Hz AC input voltage and 3 Nos of output voltage i.e. 110, 24 & 12 volts DC complete with battery back up (minimum 2 Nos x 7 AH capacity battery) suitable for operation of HT VCB 11 KV matching with existing system complete all as specified and directed by Engineer-in-charge.
S&F in replacement of ON/OFF switch with NO/NC contact suitable for VCB/OCB 11 KV complete all as specified and directed by Engineer-in-charge.
S&F in replacement of indicating lamp LED type in red, yellow, blue suitable for VCB 11 KV Panel complete all as specified and directed by Engineer-in-charge.
S&F in replacement of indoor type 3 phase 11KV/110V potential transformer, 12KV, 50 Hz, earthed type, draw-out type with accuracy class 0.5 for metering & protection, rated burden both winding 100VA, hermetically sealed to eliminate breathing and prevent air & moisture, secondary terminal should be partitioned so as to house the metering terminals separately from protection & various terminal connectors providing sufficient earth clearance complete all as specified and directed by Engineer-in-charge.
S&F in replacement of 11 KV current transformer, cast resin type, 50 Hz with ratio of 600-400/5 Amps having protection & metering core, 15 VA burden or as matching with existing, class 1.0 of minimum breaking capacity 13.10 KV for 1.0 second complete all as specified and directed by Engineer-in-charge.
S&F in replacement of master tripping relay suitable for protection/tripping of HT 11 KV VCBs Panel including carry out necessary modification in existing panel complete all as specified and directed by Engineer-in-charge.
S&F in replacement of electromechanical type over current relay (inverse) type, CDG type with range 2.5 to 10.0 Amps in 7 steps suitable for protection/tripping of HT 11 KV VCBs/OCBs Panel including carry out necessary modification in existing panel complete all as specified and directed by Engineer-in-charge.
S&F in replacement of electromechanical type earth fault relay (inverse) type, CDG type with range 1.0 to 4.0 Amps in 7 steps suitable for protection/tripping of HT 11 KV VCBs/OCBs Panel including carry out necessary modification in existing panel complete all as specified and directed by Engineer-in-charge.
Supply, Installation,testing commissioning of following items/spares in the existing panel of automatic power factor improvement (outdoor) capacitor bank having aggregate capacity 100 KVAR to 175 KVAR (As per site requirment) in different stage with microprocessor along with factory made type panel board including taking down old/unservicable following parts complete all as specified and directed by Engineer-in-charge.
Power factor corrector relay 8 to 10 stage
Capacitor duty contactor for 25 KVAR
Capacitor duty contactor for 20 KVAR
Capacitor duty contactor for 15 KVAR
Capacitor duty contactor for 10 KVAR
Capacitor duty contactor for 5 KVAR
ON-OFF push button
Aux Contactor 4 No + 4 NC
Indicating lamp ON-OFF
Power factor 25 KVAR ultra heavy duty MPP type having tolerance 0% with discharge device resistor
Power factor 20 KVAR ultra heavy duty MPP type having tolerance 0% with discharge device resistor
Power factor 15 KVAR ultra heavy duty MPP type having tolerance 0% with discharge device resistor
Power factor 10 KVAR ultra heavy duty MPP type having tolerance 0% with discharge device resistor
Power factor 5 KVAR ultra heavy duty MPP type having tolerance 0% with discharge device resistor
Digital voltmeter 0-500 V with VSS
Digital Ammeter 0-400 A with VSS & CT
M&L for restringing of LT OH conductor ACSR including binding of conductor making jumper connection etc complete all as specified and directed by Engineer-in-charge. Note:- One conductor will be measured as one length.
M&L for cutting of tree branches touching or leaning over overhead power lines (between two poles of minimum distance 30 Mtr) and removing of cut tree branches from the site complete all as specified and directed by Engineer-in-charge.
Dismantling the existing unserviceable stay assembly complete using stay rod of any size/type including breaking of PCC foundation and throwing away demolished materials at low laying areas and making good disturbed surface complete all as specified and directed by Engineer-in-charge.
M&L stay assembly complete using stay rod of 20 mm dia complete with accessories as shown in electric plate No. 1 of SSR – 2010 Part–I complete all as specified and directed by Engineer-in-charge. Note : Loop type insulator excavation , stay clamp, nuts, bolts, washers and concrete to be measured and paid separately.
Excavation in trenches in any type of soil n exc 1.5 mtr in width and n. exc 1.5 mtr in depth and getting out all as required for laying of cables,Foundation filling of poles or stays complete all as specified and directed by Engineer-in-charge.
S&F PVC Line spacer of superior quality of 2 Way spiral type complete all as specified and directed by Engineer-in-charge.
S&F PVC Line spacer of superior quality of 4 Way spiral type complete all as specified and directed by Engineer-in-charge.
Dismantling/Taking down existing unserviceable ACSR conductor of any make and removing from site or setting aside for reuse complete all as specified and directed by Engineer-in-charge.
S&F aluminum conductor steel reinforced (ACSR) for LT lines on pre-stressed concrete poles, streching without kinks and bends including aluminum binding wires complete all as specified and directed by Engineer-in-charge. (a) 1 of 6/1x2.59mm (Weasel)
Dismantling/Taking down galvanised steel earth wire of any make and removing from site or setting aside for reuse complete all as specified and directed by Engineer-in-charge.
Galvanised steel earth wire of 4mm dia with hooks, , streching kinks and bends complete all as specified and directed by Engineer-in-charge.
Dismantling taking down insulator any type any size from LT/HT poles complete all as specified and directed by Engineer-in-charge.
S&F Pin Insulator, porcelain, vitreous white, brown or green insulator incl one galvanized mild steel spindle,two galvanised iron washers and one galvanised iron nut , 100 mm height , 65 mm dia for 1100 volts grade complete all as specified and directed by Engineer-in-charge.
S&F Disc type Porcelain Insulator, vitreous brown , large size with overall dimension 145x250mm clearence of hole 25.5 mm ,working pressure 11000 volts complete all as specified and directed by Engineer-in-charge.
S&F Shackle type, porcelain, vitreous white, brown or green insulator incl one galvanized mild steel straps, washers insulator bolts , washers & nut 75 mm height, 90mm dia for 1100V grade complete all as specified and directed by Engineer-in-charge.
S&F Loop Insulator, porcelain, vitreous white, brown or green large size with overall dimension 90x140mm clearence of hole 25.5 mm complete all as specified and directed by Engineer-in-charge.
M&L Steel tubular swaged poles complete with cast iron base plate, finial taper plug, bolts, nuts & screws asspecified type 410 SP-31 (9.0 metres long) complete all as specified and directed by Engineer-in-charge.
M&L for cement concerete 1:4:8 type D2 ( using 40mm grade stone aggregate) cement concrete as in foundation filling and mass concrete for sub base of LT poles complete all as specified and directed by Engineer-in-charge.
M&L for cement concerete 1:3:6 type C2 ( using 20mm grade stone aggregate) cement concrete as in foundation filling for base of LT poles complete all as specified and directed by Engineer-in-charge.
M&L for cement concerete 1:2:4 type B1 ( using 12.5mm grade stone aggregate) cement concrete as in coping of LT poles complete all as specified and directed by Engineer-in-charge.
Excavation in trenches not exceeding 1.5 mtr wide and exceeding 1.5 mtr in depth (7 cm) for LT poles and stay and getting out soil in soft/loose soil complete all as specified and directed by Engineer-in-charge.
Removing excavated material not exceeding 50 mtr and depositing where directed in a level not exceeding 1.5 mtr above the starting point of any type of soil complete all as specified and directed by Engineer-in-charge.
S&F in replacement of LED Security light fitting 90 Watt Highly efficient made of pressure die cast housing with toughened glass with IP66 ingress protection and impact including fixing material ie MS clamp, Nut and bolt,anchor fastner washer etc complete all as specified and directed by Engineer-in-charge.
S&F in replacement of LED Security light fitting 45 Watt Highly efficient made of pressure die cast aluminium housing with high power LED as lighting source and lens embedded PC cover including fixing material ie MS clamp, Nut and bolt,anchor fastner washer etc complete all as specified and directed by Engineer-in-charge.
S&F in replacement LED post top 40 watt made in cast aluminium with decorative opal polycarbonate diffuser with IP 65 protection with necessary accessories complete all as specified and directed by Engineer-in-charge.
S&F in replacement of LED flood light 120 W luminaire with ultra sleek, light weight and with secondary optics, made of pressure die-cast housings with IP66 ingress protection including fixing material ie MS clamp, Nut and bolt,anchor fastner washer etc complete all as specified and directed by Engineer-in-charge.
S&F in replacement of GI bracket of suitable size for fixing of LED security light fitting, bracket is atleast 1.5 mtr long to be fixed on pole and it has to be bend in 45 degree angle to install the LED security light fitting including necessary welding work and MS fastner, clamp with strip complete all as specified and directed by Engineer-in-charge.
Supply, fixing and testing cable junction box MS distribution board type of Size 240 MM X 130 MM X 110 MM cucbical floor mounted type made out of 3.15 mm thick CRCA sheet duly powder coated complete with aluminium bus bar 4 Nos 415 Volts 50 Hz suitable for 40 amps mounted on epoxy based post insulators and provsion of MCB SP of 6 Amp duly fixed on pole with suitable Clamp with Nuts & Bolts etc in replacement of old u/s cable junction box complete all as specified and directed by Engineer-in-charge.
Note:- The contract sum shall be after deducting the amount of Credit shown in Credit Schedule of this Tender.
PD SHARMA AND SONS
Chaudhary Constructions
Microsys Controls India
Surjit and Sons
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .