Eligibility, documents, scope, Go/No-Go checksEligibility, required documents, scope of work and Go/No-Go checks for this tender, in one click.
Tender Value
₹3.6 L
EMD Value
₹3,620
Closing Date
13 Oct 2026, 3:00 pmDue today
Eligibility, documents, scope, Go/No-Go checksEligibility, required documents, scope of work and Go/No-Go checks for this tender, in one click.
THE COMMISSIONER, ERODE CITY MUNICIPAL CORPORATION
246, MEENAKSHI SUNDARANAR SALAI, ERODE 638001
Maintanance works for public health ward office at Iyyanarappan koil st in ward no. 41
2026_MAWS_708232_1
E1-3317-2026-07-ERODE CITY MUNICIPAL CORPORATION
Open Tender
Civil Works
Works
60 days
ERODE CITY MUNICIPAL CORPOATION
Please refer Tender documents.
1 document required · 1 mandatory
₹0
₹3,620
25 Sept 2026
25 Sept 2026
13 Oct 2026
25 Sept 2026
13 Oct 2026
25 Sept 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Dismantling the damaged Brick masonry wall including cost of labour charges and clearing away and carefully stacking materials useful for re-use for any thickness materials for all etc complete. | 3 | M2 | - | - |
| 2 | Removing the damaged Gi sheet Roofing including cost of labour charges and clearing away and carefully stacking materials useful for re-use for any thickness materials for all etc complete. | 24 | M2 | - | - |
| 3 | Dismantling the damaged PCC for flooring including cost of labour charges and clearing away and carefully stacking materials useful for re-use for any thickness materials for all etc complete. | 3 | M2 | - | - |
| 4 | Earth work open excavation in all soils and sub-soils and to full depth as may be directed except in rock requiring blasting inclusive of shoring shuttering, bailing out water wherever necessary and depositing the excavated earth with a lead of 10 mts. within the compound in places shown by the departmental officers and clearing and levelling the site, etc., complete complying with standard specification. | 1 | M3 | - | - |
| 5 | Cement Concrete 1:5:10 (One Cement, Five crushed stone sand and Ten hard broken stone jelly) using 40 mm gauge hard broken granite stone jelly for foundation including dewatering wherever necessary and laid in layers of not more than 15 cm thick well rammed, consolidated and including curing etc. complete complying with standard specification and as directed by the departmental officers. -Mixing by manual means | 3 | M3 | - | - |
| 6 | Plain Cement Concrete 1:1.5:3 (One part of Cement, one and half part of Crushed Sand (M- Sand), three coarse aggregates) using 20mm size ISS HBG metal including cost and conveyance of all materials to site and including for the mixing, laying and labour charges etc., complete as per standard specification | 4 | M3 | - | - |
| 7 | Fly Ash Brick work in CM 1:5 (one cement & five sand) using II class ground moulded bricks of size 9"X43/8"X 2 3/4" including finishing, curing, etc., complete complying with standard specification | 0.6 | M3 | - | - |
| 8 | Plastering with cement mortar 1:4 (One Cement, Four PSand) 20mm thick in all floors including cost and conveyance of all materilas to site and labour charges etc,complete as per standard specifications. | 25 | M2 | - | - |
| 9 | Plastering with cement mortar 1:5 (One Cement, Five PSand) 12mm thick in all floors including cost and conveyance of all materilas to site and labour charges etc,complete as per standard specifications. | 15 | M2 | - | - |
| 10 | supply and Fixing of polyurethane foam for Sloped roof as thermal insulation panels or Sand wich insulated panels with external 0.50mm total coated thickness pre painted Galvalume sheet with trapezoidal roofing profile having crest height of 38mm at every 333mm span, whereas internal 0.50mm total coated thickness pre painted galvanized iron sheet with micro ribbed profile and the insulation material will be chlorofluoro carbon and hydro chlorofluoro carbon free, high performance rigid polyurethane foam (PUF) conforming to IS 12436 having density not less than 40±2Kg/M3, Thermal conductivity (K-Value) 0.024 W/m.K measured at 10 degree C meantemperature along with necessary flashings such as L flashing, C flashing etc& accessories such as screws ,fastners ,sealants etc for fixing the panel etc., complete complying with standard specification. | 30 | M2 | - | - |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.13 MB
BOQ_851116.xls
BOQ • 0.25 MB
7.pdf
Tender Documents • 0.42 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .