| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹27.0 LAccepted-AOC 275 2 AJIT NAGAR UPPER GADIGARH AIR PORT ROAD JAMMU INDEX NO D 04 ADGNJ | JAMMU | JAMMU AND KASHMIR | 180001 | L-1 | Accepted-AOC Being lowest bidder | |
| 2 | L-2₹28.6 L+₹1.6 L (5.85%)Rejected-AOC | L-2 | Rejected-AOC Other than lowest bidder | |
| 3 | L-3₹28.6 L+₹1.6 L (6.03%)Rejected-AOC | L-3 | Rejected-AOC Other than lowest bidder | |
| 4 | L-4₹31.9 L+₹4.9 L (18.0%)Rejected-AOC | L-4 | Rejected-AOC Other than lowest bidder | |
| 5 | L-5₹32.5 L+₹5.5 L (20.3%)Rejected-AOC | L-5 | Rejected-AOC Other than lowest bidder |
| Sl No | Description | Qty | Unit | GENESIS INDIA L1 | BALVINDER SINGH AND SONS L2 | M/s K.S. Constructions L4 | M/s KULDEEP KUMAR CONTRACTOR L5 | M/S SUDAGAR MAL L3 |
|---|---|---|---|---|---|---|---|---|
| 1.00 | M&L for capilary rise treatment of walls as following :-
Base coat: Berger HS Latex plus (or equivalent)
Consumption base coat: 0.3 kg/m2
Second and Third coat: Latex sheild 2K (or equivalent)
Consumption top coat: 3 kg/m2
System requirements: density: 2.00 kg/ltr
Compressive strength: 0.5 N/mm2
Note :-The concerned items should be executed by OEM authorized applicator after signing of MOU (format attached as Appendix 'AB' on page no. 75 of tender documents as per Sch 'A' Note No 19 Page No 17). Non uploading of MOU by the bidder shall lead to rejection of bid during technical evaluation. | 600 | Sqm | 297 ₹1,78,200 Lowest | 340 ₹2,04,000 | 399 ₹2,39,400 | 340 ₹2,04,000 | 330 ₹1,98,000 |
| 2.00 | Demolition of brick work or stone masonary built in cement mortar including all quoins , arches, pillar etc but excluding ashlars facing dressed stone work and pre-cast concrete article complete all as specified and directed. | 5 | Cubic Metre | 99 ₹495 | 100 ₹500 | 50 ₹250 Lowest | 50 ₹250 Lowest | 1,500 ₹7,500 |
| 3.00 | Brick work with sub class ‘B’ bricks straight or curved on plan exc 6 m mean radius and built in cement mortar 1:6 all as specified and directed | 3 | Cubic Metre | 3,650 ₹10,950 | 2,500 ₹7,500 | 3,200 ₹9,600 | 3,500 ₹10,500 | 2,000 ₹6,000 Lowest |
| 4.00 | Brick work with sub class ‘B’ bricks ,straight or curved on plan exc 6 m mean radius and built in cement mortar 1:6 complete , but except bricks , i.e using serviceable bricks obtained from demolition complete all as specified and directed | 2 | Cubic Metre | 1,600 ₹3,200 | 1,500 ₹3,000 Lowest | 1,700 ₹3,400 | 1,500 ₹3,000 Lowest | 1,500 ₹3,000 Lowest |
| 5.00 | Taking down cement plaster on bricks or stone wall / ceiling decayed surfaces of concrete , roof projections or chajjas etc upto triple storey including racking out joints, hacking for key, scrubbing down with water etc complete all as specified and directed. | 4,650 | Square Metre | 6 ₹27,900 | 10 ₹46,500 | 4 ₹18,600 | 3 ₹13,950 Lowest | 5 ₹23,250 |
| 6.00 | M & L for Rendering 15mm thick fair faces of brick / concrete surfaces in cement mortar 1:4 finished even and smooth without using extra cement complete all as specified and directed. | 4,200 | Square Metre | 140 ₹5,88,000 | 180 ₹7,56,000 | 152 ₹6,38,400 | 130 ₹5,46,000 Lowest | 150 ₹6,30,000 |
| 7.00 | M & L Rendering 10mm thick on fair face of brick / concrete surfaces in cement mortar 1:6 finished even and smoth without using extra cement complete all as specified and directed. | 400 | Square Metre | 300 ₹1,20,000 | 160 ₹64,000 | 149 ₹59,600 Lowest | 150 ₹60,000 | 150 ₹60,000 |
| 8.00 | M & L Rendering 5 mm thick on concrete surfaces of ceilings in cm 1:3 finished even and smooth without using extra cement complete all as specified and directed | 50 | Square Metre | 300 ₹15,000 | 150 ₹7,500 | 170 ₹8,500 | 130 ₹6,500 Lowest | 430 ₹21,500 |
| 9.00 | Dismantling water tanks of any description 1000 Ltrs capacity complete all as specified and directed. | 20 | Each | 69 ₹1,380 | 20 ₹400 Lowest | 100 ₹2,000 | 20 ₹400 Lowest | 300 ₹6,000 |
| 10.00 | Dismantling water tanks of any description 500 Ltrs capacity complete all as specified and directed. | 10 | Each | 69 ₹690 | 20 ₹200 Lowest | 100 ₹1,000 | 20 ₹200 Lowest | 200 ₹2,000 |
Tender Value
₹49 L
EMD Value
₹98,000
Closing Date
25 Aug 2025, 6:00 pmClosed
Sh Tanuj Bagla IDSE EE GE
GE Kaluchak PIN-900673 C/O 56 APO
REPAIR TO ROOF TREATMENT, RWP AND PLASTER AT MIL STN BD BARI UNDER GE KALUCHAK
2025_MES_722982_1
GE/KC-27/2025-26
Open Tender
Civil Works
Item Rate
180 days
Kaluchak
Please refer tender documents
9 documents required · 9 mandatory
₹500
GE Kaluchak
₹98,000
Yes
16 Sept 2025
28 Jul 2025
27 Aug 2025
28 Jul 2025
25 Aug 2025
11 Aug 2025
Amount
M&L for capilary rise treatment of walls as following :- Base coat: Berger HS Latex plus (or equivalent) Consumption base coat: 0.3 kg/m2 Second and Third coat: Latex sheild 2K (or equivalent) Consumption top coat: 3 kg/m2 System requirements: density: 2.00 kg/ltr Compressive strength: 0.5 N/mm2 Note :-The concerned items should be executed by OEM authorized applicator after signing of MOU (format attached as Appendix 'AB' on page no. 75 of tender documents as per Sch 'A' Note No 19 Page No 17). Non uploading of MOU by the bidder shall lead to rejection of bid during technical evaluation.
Demolition of brick work or stone masonary built in cement mortar including all quoins , arches, pillar etc but excluding ashlars facing dressed stone work and pre-cast concrete article complete all as specified and directed.
Brick work with sub class ‘B’ bricks straight or curved on plan exc 6 m mean radius and built in cement mortar 1:6 all as specified and directed
Brick work with sub class ‘B’ bricks ,straight or curved on plan exc 6 m mean radius and built in cement mortar 1:6 complete , but except bricks , i.e using serviceable bricks obtained from demolition complete all as specified and directed
Taking down cement plaster on bricks or stone wall / ceiling decayed surfaces of concrete , roof projections or chajjas etc upto triple storey including racking out joints, hacking for key, scrubbing down with water etc complete all as specified and directed.
M & L for Rendering 15mm thick fair faces of brick / concrete surfaces in cement mortar 1:4 finished even and smooth without using extra cement complete all as specified and directed.
M & L Rendering 10mm thick on fair face of brick / concrete surfaces in cement mortar 1:6 finished even and smoth without using extra cement complete all as specified and directed.
M & L Rendering 5 mm thick on concrete surfaces of ceilings in cm 1:3 finished even and smooth without using extra cement complete all as specified and directed
Dismantling water tanks of any description 1000 Ltrs capacity complete all as specified and directed.
Dismantling water tanks of any description 500 Ltrs capacity complete all as specified and directed.
S & F of 1000 Litre capacity rotational moulded polythene water storage tanks (cylindrical vertical with closed top) of specifications as per MES Schedule 2009, Part – I and hoisted, fixed in position complete all as specified and directed.
S & F of 500 Litre capacity rotational moulded polythene water storage tanks (cylindrical vertical with closed top) of specifications as per MES Schedule 2009, Part – I and hoisted, fixed in position complete all as specified and directed.
Supply and fixing in repair 20 mm ball valves high pressure of PTMT with epoxy coated aluminium rod & high density plastic ball screwed for iron pipe minimum weight 210 gms complete all as specified and directed.
Taking up or down 20 mm bore steel tubing and connections including cleaning, threading for prefixing or removal complete all as specified and directed.
Taking up or down 15 mm bore steel tubing and connections including cleaning, threading for prefixing or removal complete all as specified and directed.
S&F Steel tubing medium grade galvanised of 20mm bore with all fitting and fixed complete to walls and ceiling or laid in floors, complete all as specified and directed.
S&F Steel tubing medium grade galvanised of 15 mm bore with all fitting and fixed complete to walls and ceiling or laid in floors, complete all as specified and directed.
Fixing only 20 mm bore old steel water tubing and connection in new or old position to wall and ceiling or laid in floors jointing and testing of old retrieved serviceable galvanized mild steel water tubing with and including all fitting (such as bends, elbows, tees, short pieces, connectors, back nuts, deminishing pieces caps, plugs and union etc) complete all as specified and directed. NOTE: - OLD STEEL WATER TUBING OBTAINED FROM DISMANTLING SHALL BE USED UNDER THIS ITEM.
Fixing only 15 mm bore old steel water tubing and connection in new or old position to wall and ceiling or laid in floors jointing and testing of old retrieved serviceable galvanized mild steel water tubing with and including all fitting (such as bends, elbows, tees, short pieces, connectors, back nuts, deminishing pieces caps, plugs and union etc) complete all as specified and directed. NOTE: - OLD STEEL WATER TUBING OBTAINED FROM DISMANTLING SHALL BE USED UNDER THIS ITEM.
M & L for Stop cock 20 mm cast cooper alloy of screwed down high pressure with crutch or Fancy type , screwed with ends for iron pipe or unions fixed in repairs. Make ISI marked
S&F Stop cock/ angle valve 15 mm cast cooper alloy of screwed down high pressure with crutch or Fancy type , screwed with ends for iron pipe or unions fixed in repairs. Make ISI marked
S&F Bib taps 15mm dia cast copper alloy fancy type chromium plated, screwed down for iron pipe or for brass ferrule fixed in repair complete all as specified and directed.
S&F Pillar taps 15 mm dia, cast copper alloy, fancy type with caS&Fpstan heads, chromium plated, screwed down high pressure with or with out lettered 'Hot' or 'Cold' with long screwed shanks and fly nuts screwed for iron pipe fixed in repairs complete all as spd & directed.
S&F Stop valve 15mm dia cast copper alloy chromium plated fancy type with long shank and cup (concealed type) srewed both ends for iron pipe or for union and fixed in repair all as spd & directed
S&F PVC (SWR) floor trap , plain with grating including jointing with solvent cement of 75mm outlet dia all as specified
Dismantling cast iron or reinforced concrete drain pipes of 75/100mm bore, fixed with walls and taking out of trenches, if required compelete all as specified and directed.
S&F PVC (SWR) pipes single socketed,110mm bore in any length with rubber ring joints, laid in trenches or in floors compelete all as specified and directed.
S&F PVC (SWR) pipes 110mm bore single socketed in any length with rubber ring joints fixed to wall including fixing clamps complete all as specified.
S&F PVC (SWR) bends any radius 110mm bore compelete all as specified and directed.
S&F PVC (SWR) branch piece, (single Y) equal or unequal 110mm bore compelete all as specified and directed.
S&F PVC (SWR) junction single (single T) equal or unequal 110mm bore compelete all as specified and directed.
S&F PVC (SWR) pipes single socketed,75mm bore in any length with rubber ring joints, laid in trenches or in floors compelete all as specified and directed.
S&F PVC (SWR) pipes 75 mm bore single socketed in any length with rubber ring joints fixed to wall including fixing clamps compelete all as specified and directed.
S&F PVC (SWR) bends any radius 75mm bore all as specified compelete all as specified and directed.
S&F PVC (SWR) branch piece, (single Y) equal or unequal 75mm bore compelete all as specified and directed.
S&F PVC (SWR) junction single (single T) equal or unequal 75mm bore compelete all as specified and directed.
S&F PVC(SWR) vent cowl 75 mm bore compelete all as specified and directed.
M & L preparation of new plastered surfaces of walls/ ceiling and material and labour for applying two coats of oil emulsion distemper over a coat of chalk whiting all as specified and directed.
M & L preparation of new plaster surfaces of walls and material and labour for applying two coats of weather coat over one coat of primer, all as specified and directed.
M & L preparation of old distempered surfaces and applying one coat of oil emulsion distemper on walls and ceilings upto tripple storey all as specified and directed.
M & L for preparation of new or previously untreated wooden surfaces exc. 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer complete all as specified and directed.
M & L for preparation of steel surfaces over 10 cm width or girth and applying two coats of synthetic enamel paint over one coat of red oxide primer complete all as specified and directed.
M & L complete removal of of exiting treatment from wall and finish the undulated surface by cement putty and applying two coat of weather proof paint after application of one coat of primer complete all as specified and directed
M & L providing cement concrete type B-0 1:2:4 (using 12.5 mm graded stone aggregate ) in roof padding, roof kerbs or mud stops, rounded or chamfered on edges
M&L for Home Sheild PU Roofkoat (or equivalent) is a one component liquid, solvent free, cold applied water-proofing membrane that is highly elastic and UV resistant with 10 years warranty. ASTM D 6083-97 a waterproofing and heat reflecting system having following key performace properties : 1. UV resistant, prevent yellowing and weathering 2. Highly elastic upto 350% and crack bridging 3. Excellent adhesion on porous and non-porous substrates 4. Tensile strength > 10 N/mm2 with Geo Textile fleece 5. Soler reflective Index (SRI) more then 109-111 ASTM E 1980-11 System : First coat : Providing and applying primer over the prepared surface with HS PU roofkoat Primer (or equivalent) Coverage :0.2kg/m2 (with 50 % dilution of water) Reinforcement : Geotextile 40 gsm Second coat : Home sheildroofkoat (or equivalent) Consumption : 0.5 kg/m2 Third coat : HS PU roofkoat (or equivalent) Consumption : 0.8 kg/m2 System buildup-1.5kg/sqm with geotextile of 40 gsm For accessible roof, tiles with scred/ adhesive may be fixed thereafter. Note :-The concerned items should be executed by OEM authorized applicator after signing of MOU (format attached as Appendix 'CD' on page no. 79 of tender documents as per Sch 'A' Note No 19 Page No 17). Non uploading of MOU by the bidder shall lead to rejection of bid during technical evaluation.
BALVINDER SINGH AND SONS (BID ID -3405107)
M/S SUDAGAR MAL (BID ID -3405505)
M/s K.S. Constructions (BID ID -3405705)
M/s KULDEEP KUMAR CONTRACTOR (BID ID -3405299)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .