EE E BSNL ED LUDHIANA
The Executive Engineer E BSNL Electrical Division Ludhiana TE Bldg SBS Nagar Ludhiana
Repairing Servicing and Shifting of DEA sets at various Sites in Ropar OA
2023_BSNL_170073_1
EE/E/BSNL/ED/LDH/NIT/23-24/20
Open Tender
Electrical Works
Works
15 days
ROPAR
Please refer Tender documents.
2 documents required · 2 mandatory
₹580
AO BSNL Ludhiana
₹10,293
25 Oct 2023
7 Oct 2023
20 Oct 2023
7 Oct 2023
16 Oct 2023
7 Oct 2023
Amount
Sub Head-I ( Servicing and shifting of DEA set works )
General Servicing of following capacity of DEA sets of different makes and models under various exchanges comprising of following jobs i/c Transportation, Labour charges & material required for servicing i/c minor material required for healthyness of DG set etc. as reqd. (i) Cleaning & greasing of the parts. (ii) Tappet setting as per standard (iii) Fan belt, tensioner pulley and lever adjustments. (iv) Tightening of all the nuts, bolts and clamps. (v) Testing & checking of AC & DC Wiring. (vi) Self & Charging Alternator cleaning and testing, checking of working & minor fault removal. (vii) Checking of Supply & return fuel pipes from fuel tank to engine. (viii) Replacement of consumables like lub Oil, diesel filter, Oil filter, filter element of air cleaner & coolant (in case of water cooled engines). (ix) Checking of FIP timing by Fuel cut off method. (x) General servicing i/c cleaning of DG panel (xi) General servicing & complete cleaning of DG set
Dismentling of existing silent canopy /open type DEA Set of capacity up to 50 KVA of different Make & model with Manual /AMF control panel with Power and control cable , Silencer and exaust pipe , diesel tank , battery and associated fuel line and all other electrical acessories etc complete at TE/BTS site i/c making good the damage etc as reqd.
Shifting of existing dismentalled Silent canopy/open type DEA Set of capacity up to 50 KVA of different make and model a/w all acessories like AMF Manual control panel with power and control cable , silencer ,exaust pipe , diesel tank and fuel line ,battery and all other electrical acessories etc complete from One TE /BTS /BSNL Campus to other TE /BTS/BSNL Campus for distance up to 100 KM i/c loading at TE /BTS/BSNL campus and transportation to other TE/BTS Site and unloading the same at TE/BTS site on existing CC foundation etc as reqd. Note -Safe loading and transportation and unloading will be responsibility of agency ,any damange during loading ,transit and unloading will be making good ny agency without any extra cost .
Installation, testing , commissioning of Existing Silent canopy /open type Diesel Engine Alternator set of capacity up to 50 KVA of different make & model on existing CC foundation with all acessories like Cubical type manual /AMF control panel i/c fixing of Silencer ,exhaust pipe , fuel tank , fuel line connections, control wiring from panel to engine i/c cutting, jointing, welding of flanges (if reqd) , nuts, bolts , i/c two coat silver paint on exhaust pipe and silencer i/c making good the damage etc. i/c 30 min testing of DG set on exchange load etc as reqd (Note -All consumable like diesel will be arrange by the ageny for comissioning purpose )
Sub Head-II ( Repairing Works of DEA Sets )
Providing maintenance free New Lead acid Batteries following types/rating complete with first fill of electrolyte & first charging i/c replacement of leads, nut bolts ,terminals/thimbles complete as reqd.
12V, 130 AH ( M/S Exide Express Model No. FXPO-XP1300 or equivalent model of Similar Superior make)
12V, 100 AH ( M/S Exide Express Model No. FXPO-XP1000 or equivalent model of Similar Superior make)
Replacement of following defective accessories in the existing DG sets with new accessories, complete as reqd. [Dismantled defective accessories shall belong to vendor, credit for same has to be considered while quoting rates.]
Stop Solinoid 12 volt (Engine shut off solenoid)
12 Volt Electrical Battery Charger (SMPS ) i/c Transformer, Rectifier unit and Filter Circuit etc. complete as reqd.
Oil pressure gauge
Oil temperature meter with safety
Starting key switch
VAF meter
32 Amp 4 pole MCB
63 Amp 4 Pole MCCB
Steel wire braided fuel pipe with benjo bolts & washer
12 Volt DC/ 220 Volt AC hour meter
Battery Leads Red & Black Standard Length & Size i/c brass terminals
Fan Belt
Control wiring of DEA set i/c replacement of Start / Stop push button i/c NO/NC for running of DEA set from Panel
Replacement of radiator suitable for 50KVA water cooled DEA set i/c hose pipes , nut blots, drilling , welding , painting interconnections etc as reqd.
Servicing of the self starter of DEA set i/c dismantling, cleaning of self with petrol, greasing and oiling of bearing i/c testing etc complete as reqd.
This item exclude the cost of parts associated with Self Starter.
Repairing of following faulty items in the self starter of DEA set i/c dismantling of unserviceable/ defective items, fixing with new one i/c connection, testing etc complete as reqd.
[Note: Labour charges already covered in item No 3]
Carbon bush set
Solenoid coil
Bendex Gear
Supply of 12 volt battery operated self starter suitable for engine alternator set in place of existing faulty self starter including fixing the same on the DG set making connection testing etc complete as required.
Calibration of the fuel injection pump of following capacity of DEA sets of different makes and models under various exchanges I/c removal of fuel pump from site, transportation at Workshop, calibration of pump and nozzles, grinding and fixing the same after calibration at site in the existing DEA set etc complete as reqd.
1 Certificate from authorised service centre is to be submitted regarding calibration of fuel pump & nozzles.
2 This item exclude the cost of parts associated with fuel pump
up to 20 KVA DEA set
More than 20 KVA and up to 50 KVA
Extra charges for associated items of fuel pump, if required.
[Note: Labour charges already covered in item No 7]
Delivery valve
Delivery element
Nozzle
Replacement / Repairing of faulty items in the existing Alternator up to 50 KVA Alternator at TE / BTS Sites i/c dismantling the faulty, replacement by new one i/c fixing, testing, commissioning etc. complete as reqd.
AVR Make National or S.S.
Power Diode for Rotating Rectifier Assembly
Rewinding of following parts of existing alternator upto 50 KVA with suitable size copper enamelled wire including providing of insulation of appropriate class, varnishing, assembling including transportation charges for alternator from Site to Workshop & back after repairing and dismantling, loading, unloading, transportation, safe Handling & Commissioning after repairing, testing etc complete as required.
Main Stator winding
Main Rotor winding
Exciter Stator winding
Exciter Rotor winding
Repairing of existing canopy of 15 KVA DG set by providing suitable GI sheet on damaged roof,jointing/fixing with rivets/screws/welding etc including providing& fixing of hinges of broken doors /welding etc complete etc as required.
Rewinding of existing exhaust fan in 15 KVA DG silent enclosure complete in all respects,i/c dismantling from site ,carriage ,rewinding and refixing at site complete etc as reqiured.
Supplying and fixing of 450 mm sweep ,1500 rpm exhaust fan suitable for working on 250 V single phase AC supply including fixing, interconnections complete etc as required.(for sites where exfan is missing/theft case)
Labour charges for top overhauling of existing following capacity of DEA set I/c removal, repair of engine parts, cleaning of all the parts such as exhaust/inlet manifold, cylinder head chamber, cylinder block, fly wheel,self starter,battery charging alternator etc complete as required.
1 The cost of required parts shall be paid extra against item No 2,3 & 4
2 Labour charges for servicing of radiator, crank shaft, repairing/grinding nozzle testing, turbo charger is not included in this item.
up to 40 KVA DEA set
Removal of following faulty / burnt / damage parts in the existing up to 40 KVA DEA set and providing & fixing of new parts to bring the Engine in healthy condition etc. complete as reqd.
Oil seal of crank shaft (front & rear)
Main bearing
CR bearing
Connecting rod
Piston assembly
Piston ring
Liner
Liner O ring
Head gasket
Valve (Inlet and Exhaust) with guide
Set of gasket
Set of O ring
oil seal deiven
Oil seal driver end
Thrust washer
Lub oil pump
Hose pipe set
Supply and fixing of 12 volt battery charging alternator on the existing DG set in place of existing faulty battery charging alternator i/c making connections testing etc. complete as reqd.
Servicing of Battery Charging Alternator / Dynamo i/c Dismantling of equipment, cleaning, greasing and oiling of bearings and other parts etc. complete as required. Note-This item exclude the cost of parts associated with Self Starter.
S/F of 63 amps four pole on load change over switch in steel enclosure with side handle operation capable of working 415/500 V i/c drilling hole on the board, making connection, earthing the body etc. as reqd.
S/F of 100 amps four pole on load change over switch in steel enclosure with side handle operation capable of working 415/500 V i/c drilling hole on the board, making connection, earthing the body etc. as reqd.
Less for old faulty DG set battery of following capacity
12 Volts 88 AH
12 Volts 130 AH
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .