Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹6.7 LAccepted-Finance | 1 | Accepted-Finance 1st Lowest | |
| 2 | 2₹8.6 L+₹1.9 L (29.1%)Accepted-Finance | 2 | Accepted-Finance 2nd Lowest |
Tender Value
₹5.9 L
EMD Value
₹11,753
Closing Date
30 Mar 2023, 10:00 amClosed
Executive Engineer, Store Division, APWD., Port Bl
Executive Engineer, Store Division, APWD., Port Blair
A/R and M/o 20 Nos Split Type Air Conditioners in Andaman Bhawan at Anna Nagar Chennai under Stores Division, APWD during 2022-2023
2023_APWD_9760_1
e-Tender/DB/SD/2022-23/192
Open Tender
Electrical Works
Works
365 days
Anna Nagar Chennai
4 documents required · 4 mandatory
₹0
₹11,753
Yes
12 May 2023
15 Mar 2023
30 Mar 2023
15 Mar 2023
30 Mar 2023
16 Mar 2023
16 Mar 2023 - 29 Mar 2023
Amount
Providing services of Skilled/ Un-Skilled labours for repair and maintenance of Air Conditioners, IEI & EEI on daily basis round the clock or as and when required basis for a period of one year during 2022-23.
Air Conditioner Mechanic
Wireman
Presssure testing for leakage flushing vaccummising the system, gas charging with Freon -22 servicing the unit testing for satisfactory performance, replacement of necessary spare parts i/c re installation of the unit etc as required for AC.
Replacement of defective compressor unit with new one suitable for following capacity room AC i/c pressure testing for leakage, flushing vaccumising the system gas charging with freon -22 servicing the unit, painting and testing for satisfactory performance, replacement of necessary spare parts i/c reinstallation of the unit duly tested etc as required.
Replacement of damaged condensor coil with new copper condensor coil suitable for following capacity split type AC i/c dismantling the damaged coil, fixing the new one, gas charging, re-installation and plating patch repair work if any, testing and commissioning the unit etc as required. .
Repalcement of defective AC blower motor/indoor fan motor by new one for 1.5 Ton capacity , AC.
Repalcement of defective AC blower motor/indoor fan motor by new one for 2.0 Ton capacity , AC.
Repalcement of defective AC outdoor fan motor by new one for 1.5 Ton capacity AC.
Repalcement of defective AC outdoor fan motor by new one for 2.0 Ton capacity AC.
Providing and fixing of refrigerant copper pipes of following sizes (Suction & delivery) of split type AC i/c providing electrical cables, insulation, extra gas charging and covering with PVC non adhessive tape over the insulation of refrigerant pipes to give smooth finish and as per the direction of Engineer-in-Charge.
Refrigerant pipes of Sizes 5/8" & 3/8"
Repalcement of defective Voltage Stabilizer 4 KVAR for 1.5 Ton capacity similar to V-Guard Model No: VND-400/Microtek EM/IFB IVS etc. or equivalent as required.
Repalcement of defective Voltage Stabilizer 5 KVAR for 2.0 Ton capacity similar to V-Guard Model No: VND-500/Microtek EM/IFB IVS etc. or equivalent as required.
Supplying Installing testing & Commissioning of PCB for 1.5/2.0 Ton A.C as directed by the Engineering- in- Charge
Supplying of following spares and accessories for maintenance of Air Conditioners installed in the Andaman Bhawan as and when required basis.
Single Core Contractor
45 MFD Pin type (ALU Body)
60MFD Pin type(ALU Body)
Insulation Tape (roll)
Freon (R-22) Gas
Welding can(flame gas)
Welding rod
RSK CONSSTRUCTIONS
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .