Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹9.9 LAccepted-AOC AZAD COLONY B 90 FEET ROAD SOURA SRINAGAR J K 190011 | SRINAGAR | SRINAGAR | JAMMU AND KASHMIR | 190011 | L1 | Accepted-AOC Being lowest | |
| 2 | L2₹11.2 L+₹1.3 L (13.1%)Rejected-Finance 1597 1ST FLOOR SECTOR 45 BURAIL CHANDIGARH CHANDIGARH 160047 | CHANDIGARH | CHANDIGARH | 160047 | L2 | Rejected-Finance Not being lowest | |
| 3 | L3₹11.8 L+₹1.8 L (18.6%)Rejected-Finance | L3 | Rejected-Finance Not being lowest | |
| 4 | L4₹12.7 L+₹2.8 L (27.8%)Rejected-Finance BOOTH NO 56 MAIN MARKET SECTOR 40 C CHANDIGARH U T 160036 | CHANDIGARH | CHANDIGARH | CHANDIGARH | 160036 | L4 | Rejected-Finance Not being lowest |
Tender Value
₹13 L
EMD Value
₹26,000
Closing Date
18 Dec 2020, 12:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE 970 EWS
GE 970 EWS c/o 56 APO
PROVN OF 02 NOS UPS 15 KVA WITH BATTERY AND CONNECTED WORKS AT OLD AIR FIELD, SRINAGAR UNDER GE 970
2020_MES_396639_1
GE 970 EWS-49/2020-21
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
Old Air Field Srinagar
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
GE 970 EWS
₹26,000
Yes
4 Feb 2021
20 Nov 2020
21 Dec 2020
20 Nov 2020
18 Dec 2020
4 Dec 2020
60 days
Amount
Supply, fixing, testing and commissioning UPS for minimum 4-6 Hrs backup having 3 Phase AC input voltage of 300 to 450 V and output voltage single phase AC 230 V / Three phase 415 Volts 50 Hz with + 1% variation of capacity 15 KVA double convertion online UPS system, IGBT based fully microprocessor controller and indication such as UPS ON/OFF, over load, battery charging, Bypass arrangements, Overcurrent trip relays, power ON/OFF buttons, Safety Fuses, under voltage indications, over current tripping systems incl battery backups and battery rack made up of MS Angle iron / Flat duly powder coated painting with 12Volt, 150 AH SMF VRLA batteries-12 Nos or equiavlent capacity power batteries and interconnecting copper cables as per OEM specifications complete all as specified and directed. Makes of UPS :- Exide / Microtec / Luminious or techno-commericially equivalent in approved makes.
M&L sub main wiring with four runs of single core 6.0 Sqm, FRLSH copper conductor PVC insulated unsheathed mutlistranded cable as per IS 694-1990 (third revision) drawn through & including non- metallic rigid PVC casing caping (double interlock type) of suitable width (not less than 25mm, ISI marked) medium duty with all accessories such as Tees, elbows, junction boxes etc, as required fixed on wall along with two runs of 4.0 Sqmm single core PVC FRLSH insulated unsheathed copper conductor cable as continuous earth wire and connecting to existing main switch board/ distribution board and testing on completion etc complete all as specified and directed. Note :- Four runs of cable, two run of earth continuity conductor and one run of PVC casing caping/conduit shall be measured as one unit.
S&F DB with sheet metal enclosure 240 volts, 4 way with 200 Amp rated bus bar single pole & neutral double door type complete all as specified and as directed.
S&F MCB TPN 32 Amp, 'C' curve 10 KA complete all as specified and as directed.
M&L LT cable XLPE insulated heavy duty armoured sheathed 1100 volts grade, 16 Sqmm, 4 core, with aluminium conductor, ISI marked as per IS : 7098(Part-1) for house service connections connecting from pole/panel to DB's etc complete all as specified and as directed.
M&L Earthing complete with galvanized steel earth plate, 60 cm x 60cm x 6 mm, as earth electrode thick buried directly in ground (earth pit not less than 2.25m deep below normal ground level) with top edge of the plate not less than 1.5 metre below normal ground level, connected and and including GI strip 32mmx6mm by means of GI bolts, nuts, check nut and washers, earth plate surrounded by packed alternate layers of coal dust and common salt 15cm thick all around top and bottom and watering pipe 20mm bore of GI pipe light grade with funnel and wire mesh and 50mm bore GI pipe light grade for protection of GI strip 32mmx 6mm from top of earth upto test point (upto 7.5metre in depth) connected with suitable size of GI nuts, bolts and washers all as shown in Electrical plate No. 03 of SSR-I, testing on completion including excavation/ earth work in any type of soil/ rock. PCC chamber 1:3:6 using 20mm graded stone aggregate and 50mm thick RCC 1:2:4, type B1 cover slab reinforced with 8mm dia TMT steel bars @ 100mm c/c both ways with suitable handle for lifting arrangements and including formwork and MS frame using MS angle iron 40mmx40mmx6mm complete all as specified and directed. Note:- Earth pit shall be constructed 50 cm from the side of excavation to avoid sinking of pit.
ADP Engineering
M/S M.R. Construction
L-7 Primewave Communications
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .