| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹5.8 LAccepted-AOC GHORADHARA JHARGRAM | L1 | Accepted-AOC Lowest Rate | |
| 2 | L2₹5.8 L+₹5,783 (1.00%)Rejected-Finance 211 2 NARAYANTALA EAST BAGUIHATI KOLKATA | KOLKATA | WEST BENGAL | 700001 | L2 | Rejected-Finance Higher than L1 | |
| 3 | L3₹5.9 L+₹8,674 (1.50%)Rejected-Finance ADAM KANAN JHARGRAM 721507 | JHARGRAM | WEST BENGAL | 721507 | L3 | Rejected-Finance Higher than L1 |
Tender Value
Refer Docs
EMD Value
₹11,920
Closing Date
25 Nov 2022, 3:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
The Executive Engineer
Raghunathpur, Jhargram.
WBPHE/EE/JMD/NIeT 18_2 OF 2022-2023
2022_PHED_421415_2
WBPHE/EE/JMD/NIeT 18 OF 2022-2023
Open Tender
Miscellaneous Works
Item Rate
30 days
Jhargram
Please refer Tender documents.
4 documents required · 4 mandatory
₹11,920
Yes
9 Dec 2022
16 Nov 2022
28 Nov 2022
16 Nov 2022
25 Nov 2022
17 Nov 2022
Amount
Supply and delivery of following material at site:- Submersible pumping machinery directly coupled with submersible motor suitable for above pump having power supply at 230V (±10%), 50 Hz (±3%) Material of Construction : Pump bowl. Housing : C.I. Pump / motor shaft : SS-410. Impeller :Bronze/CS/SS NRV Size: 50 mm Starting Method : DOL Speed : 2900 rpm max. i) Q = 8 m3/hr ii)H = 56 mtr (Test certificate, H&Q characteristic curve should be provided at the time of delivery) Make:- As per approved vendor list of PHED vide no.PHE/IV/2277/W-181/19 dated 25.09.2019
50 mm dia UPVC ( Standard type) column pipe with both side threaded and one side socketed a) 3 Mtr. Long
b) 1.5 Mtr. Long
c) 50 mm dia top & bottom Adoptor (CI)
102 mm. dia 0-7 kg/cm² range wall mounted bourdon type pressure gauge complete with brass cock & other fittings as per direction of E.I.C for tubewell outside the pump house. Make :- As per approved vendor list of PHED vide no. PHE/IV/2277/W-181/19 dated 25.09.2019.
102 mm. dia. wall mounted bourdon type depth gauge capable to measure direct reading in feet with 6mm PVC air pipe with socket (assembly should be 50mtr. long) including supply of one good quality hand pump hand pump for tubewell outside the pump house. (This cost includes 15 mm. dia. G.I. Pipe approx. 40 ft. length and specials) Make :- As per approved vendor list of PHED vide no. PHE/IV/2277/W-181/19 dated 25.09.2019.
M.S fabricated split type suitable tube well cover as per tube well housing with necessery clamping arrangement including provision of holes for column pipe ,air pipe and cable entry etc. all complete as per direction of E.I.C
Anti-snapping safety device for above pump by supplying suitable 0.5" dia. Nylone rope of required length (double) including supply of all necessary materials as required.
M.S suspention clamp with necessery nuts,bolts & washer etc suitable for 50 mm dia pipe ( Size 300 mm X 50 mm X 8 mm each)
1.1 KV Grade 415 V, 2 core 10 sq.mm. PVC sheathed XLPE insulated Al. armoured cable conforming to IS:7098 (PART-1) 2011 with latest amendmends as applicable. Make :- As per approved vendor list of PHED vide no. PHE/IV/2277/W-181/19 dated 25.09.2019.
1.1 KV grade, 2.5 sq.mm. 3 core PVC insulated & sheathed copper flat submersible cable conforming to IS: 694 (PART-1) with latest amendmends as applicable. Make :- As per approved vendor list of PHED vide no. PHE/IV/2277/W-181/19 dated 25.09.2019.
50 mm dia, P.N. 1.0, CIDF Non return valve conforming to IS: 5312, part-I. Make :- As per approved vendor list of PHED vide no. PHE/IV/2277/W-181/19 dated 25.09.2019.
50 mm dia, P.N. 1.0, CIDF sluice valve conforming to IS: 14864. Make :- As per approved vendor list of PHED vide no. PHE/IV/2277/W-181/19 dated 25.09.2019.
50 mm dia ,PN-1.0 CIDF wafer type butterfly valve with single phase actuator operated conforming to IS:13095/1991. Make :- As per approved vendor list of PHED vide no. PHE/IV/2277/W-181/19 dated 25.09.2019.
50 mm dia heavy type suitable length CI/MS Black pipes (for common delivery header,backwash line for pump under sl no-1, along with necessary bends, specials, fittings , viz flanges, bolts, nuts, gaskets, concentric enlarger , MS dismenteling joint, for connecting main pipe line etc. including providing MS/Bricks/PCC support for laying of pipes, valves as required to make the installation complete.
230 V MCC cum PDB (1-3 HP with DOL, Direct Online starter) with minimum 2 mm thickness and degree of protection IP-54, conforming to IS-8623 with suitable Bus Bar, Digital Voltmeter Ammeter, Contactor, Delay timer, MCB, Valve Actuator, starter etc. with PLC logic as detailed in attached technical specification. (Make :- As per approved vendor list of PHED vide no. PHE/IV/2277/W-181/19 dated 25.09.2019 with latest amendments.)
10 KVA, single phase, oil cooled type having unbalance 115-289V input voltage and 230 V(± 1%) output voltage, auto/manual servo voltage stabilizer with U/V,O/V,O/L protection with MCB at output side & input MCCB, Ammeter Bell etc. As per IE Rules and as per technical specification. Make:-As per approved vendor list of PHED vide no PHE/IV/2277/W-181/19 dated 25.09.2019
LED street light luminarie IP 66 LM6-HPDC Housing Street light aerodynamically designed with better thermal management/ Potted driver is to be provided,the luminaire and housing should be from the same manufacturer(cat no- BRP052 LED 045 CW SLMR FG S1 PSU GR ,System Efficacy greater than 100 lumen/watt) Make-Philips OR Equivalent and same techinal specification of Havells.The manufacturer has to provide LM79/LM80 reports corresponding to the luminaire/LED Chip along with type test Certificate.Respectively the luminaire manufacturer should have an in house NABL Accredited testing facility.
63 Amp, 10 kA, 240/415V, 50 Hz Double pole MCB Isolator conforming to IS / IEC: 60947-3, "C" characteristics with enclosure. Make :- As per approved vendor list of PHED vide no. PHE/IV/2277/W-181/19 dated 25.09.2019.
6-32 Amp Amp,10 kA, 240/415V, 50 Hz SP MCB conforming to IS / IEC: 60898-1, "C" characteristics. (6 Amp - 1 no., 16 Amp - 1 no.) Make :- As per approved vendor list of PHED vide no. PHE/IV/2277/W-181/19 dated 25.09.2019.
10 Amp,10 kA, 240/415V, 50 Hz SPN MCB conforming to IS / IEC: 60898-1, "C" characteristics. Make :- As per approved vendor list of PHED vide no. PHE/IV/2277/W-181/19 dated 25.09.2019.
6 way SP&N Double Door horizontal Distribution Board (I/C 2 + O/C 4) conforming to IS 13032 & IS 8623 and IP42/43. Make :- As per approved vendor list of PHED vide no. PHE/IV/2277/W-181/19 dated 25.09.2019.
63 Amp. 2 pole on load change over switch Make: As per approved vendor list of PHED vide no. PHE/IV/2277/W-181/19 dated 25.09.2019.
PVC moulded chair without arm. (Make:- Nilkamal/Supreme/Cello)
PVC moulded table of 850 x 850x 725 mm size. (Make:- Nilkamal/Supreme/Cello)
63 Amp, 240/415 V Porcelain fuse unit (Base & Bridge) Make :- As per approved vendor list of PHED vide no. PHE/IV/2277/W-181/19 dated 25.09.2019.
Hard wooden board (450mm X 304.8 mmx 2 mm thick)
1.1 KV grade, 12 core, 1.5 sq. mm. Copper Control Cables, Solid Copper Conductor & Balance Stranded Copper, XLPE Insulated PVC Inner sheathed, Armoured extruded PVC Type ST2 Sheathed as per IS 7098 (Part 1) 1988. (For actuator connection from panel) Make :- As per approved vendor list of PHED vide no. PHE/IV/2277/W-181/19 dated 25.09.2019.
Installation of item Installation, testing & commisioning of above supplied Pumping Machinery MCC,valves etc. (item no 1 to 9, 12 to 16,17, 20 to 24, 27, 28) by jointing submersible cable within the tubewell situated outside the pump house by making derrick arrangement by assembling the column pipes properly and fitting, fixing the pressure gauge, depth gauge, air pipe etc. in position and erection of delivery line & wash out line with the C.I specials and Tee including mending damages goods etc. all complete as per direction. This also includes the charges for laying submersible cable from tubewell to control panel by underground and saddle on wall and connection with required feeder of panel all complete.
Making suitable size pump foundation base ( Size: 1.00 mtr. x 1.00 mtr. x 1.5 mtr.) with supplying cement, sand, stone chips etc. in the portion of (4:2:1) including plastering, neat cement finishing etc. all Complete as per direction of EIC. (i) Tubewell outside pump house
Making required nos. of brick pillar 0.25 mtr. X 0.25 mtr. For supporting of valves and pipes with 12 mm thick plaster and net cement finish complete.
Laying of cable (as in item no. 10) on wall/surface incl. S & F of MS saddles with earthing attachment in 10 SWG GI (Hot Dip) wire, making holes etc. as necy. mending good damages and painting all complete as per direction of E.I.C.
Supplying and fixing of compression type gland complete with brass gland, brass ring & rubber ring for dust & moisture-proof entry of cable (as in item no. 10) all complete as per direction of E.I.C.
Finishing the end of cable (as in item no. 10) by crimping method incl. supplying and fixing solderless socket (Dowels make), tapes, anticorrosive paste & jointing materials all complete as per direction of E.I.C.
Making internal wiring/electrification of the Pump house by (2x 22/0.3 (1.5 sqmm) + 1x 22/0.3 (1.5 sqmm) single core PVC insulated multistrand FRLSH Grade flexible copper wire through 20 mm PVC conduit pipe/casing by supplying one no. 40 Amp, 10kA, 240/415V,50 Hz SPN/DP MCB Isolator conforming to IS / IEC: 60947-3, "C" characteristics. (As per approved vendor list of PHED vide no. PHE/IV/2277/W-181/19 dated 25.09.2019) with required module PVC Board & piano key type switch. (ave. run 6 mtr). i) LED Tube set point-2 nos., Bulk Head light point- 1 no., 5 pin 6 Amps. Plug point- 1 no., 16 Amp socket & switch- 1 no, indicator- 1 no. each, with necy. earthing arrangement & one fan point (Total point 6 nos. points) including drawing power by suitable gauge (2.5 mm2) of copper wire from installed cut-out to SPN/DP MCB within DB through 20 mm PVC casing capping (precision make) as per direction of EIC (fittings should be of Philips make & wiring should be with continuous earthing arrangement and 20W two nos. 4 ft long LED tube light sets PHILIPS Astra Line, one no. bulk head (Endura WT202W LED6S NW PSU S2 PC), one no. 0-4 step fan regulator (Humfree), fittings etc to be supplied by agency).
S&F of 3" dia 1.5 mt minipole with baseplate to be fixed on rooftop incl. S&F of 1.5 mtr long arm bracket (removable type) incl. CC (6:3:1) muffing (450X450X600) with 3 mm thick neat cement finish & painting incl. S&F of 200x150x100 mm 16 SWG GI loop box with necessary power connection by 3x 22/0.3 (1.5 Sq.mm) (2 nos. P&N and 1 no. ECC) 'FRLSH' PVC insulated & unsheathed copper wire (Approved make) in 20 mm size PVC rigid conduit 'FRLSH' (Precision make) incl. necy. fittings as required as per direction of EIC. (for 12m length)
(a) Earthing with 50 mm ISI mark medium diameter G.I. pipe 3.64 mm thick x 3Mtr. (10ft.) long and 1 x 4 SWG G.I. wire (4Mtr.long) 13 mm diameter x 80mm (3inch) long G.I. Bolts, double nuts, washer including S & F of 15mm diameter G.I. pipe protection (1 Mtr. Long) to be filled with bitumen partly below ground level to an average depth of 3.65Mtr.(12ft.) below the ground level and restoring the surface duly rammed. i) For soft soil by ISI Medium GI pipe.
(b) Extra for providing masonery enclosure on the top of the earth electrode of overall size 86.36 cm x 86.36 cm x 46 cm deep (below Ground level) complete with cemented brick work(1:6) of 25 cm width duly plastered with cement morter (inside) CI hinged inspection cover of size 36.56 cm x 35.56 cm with locking arrangement, GI reducer including drilling of 46 nos. 12 mm dia holes on the GI pipe.
(c) Extra for treatment of soil by salt and charcoal coke for pipe electrode.
(d) Supplying & fixing earth busbar of galvanized (Hot Dip) MS flat 25 mm x 6 mm on wall having clearance of 6 mm from wall including providing drilled holes on the busbar complete with GI bolts, nuts, washers, spacing insulators etc. as required.Length of busbar is 0.5 mtr.
(e) Connecting the equipments body to earth busbar including S & F of 20 mm x 6 mm galvanised (Hot Dip) MS flat on wall/floor with GI saddles as required and connection to equipments incl. drilling holes, with bolts, nuts, washers etc. all complete as per direction of E.I.C.
Supply, delivery and fitting-fixing of 230 volt ,1200 mm sweep AC ceiling fan with ball bearing complete with all accessories such as blade, canopy, fork, down rod etc. Make :- As per approved vendor list of PHED vide no. PHE/IV/2277/W-181/19 dated 25.09.2019.
Carrying back the old unserviceable part from work site to DCC campus store including loading, unloading complete.
Add: 18% GST
Add: 1% CESS
P K ENGINEERING
DEBJYOTI BASU
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .