Loading…
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Tender Value
₹56.0 L
EMD Value
₹1.1 L
Closing Date
11 Dec 2025, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Col S P Singh
Commander Works Engineers (AF) Lohegaon, Pune - 411 032
CONSTRUCTION OF DEFICIENT LIVING IN CPL AND BELOW BILLETS AT SITE R AT AF STN THANE
2025_MES_732652_1
82673/E8
Open Tender
Miscellaneous Works
Lump-sum
360 days
GE AF Thane
AS PER NIT AND TENDER DOCUMENTS
6 documents required · 6 mandatory
₹1,000
GE AF Thane
₹1.1 L
Yes
25 Sept 2025
25 Sept 2025
18 Dec 2025
25 Sept 2025
11 Dec 2025
28 Nov 2025
NOTE: Schedule ‘A’ Part I to IX under Ser No 1 to 9 are Prepriced by MES. Bidders shall insert their lumpsum amount in the Green coloured field under Col-6 only.
Lump sum price worked out for Building / Structures as listed in Sch `A’ Part I.
Lump sum price worked out for Excavation / Earthwork & Site Clearance as listed in Sch `A’ Part II
Lump sum price worked out for Internal Water Supply as listed in Sch `A’ Part III
Lump sum price worked out for Internal Electrification as listed in Sch `A’ Part IV
Lump sum price worked out for Road/ Path/ Paved Area as listed in Sch `A’ Part V
Lump sum price worked out for Sewage Disposal as listed in Sch `A’ Part VI
Lump sum price worked out for Area Drainage as listed in Sch `A’ Part VII
Lump sum price worked out for External Water Supply as listed in Sch `A’ Part VIII
Lump sum price worked out for External Electric Supply as listed in Sch `A’ Part IX
SCHEDULE 'A' PART - X MISCELLANEOUS ITEMS (Note for Item No 10.00 to Item No 13.00 : Bidder shall insert their rates for each of these items separately in Green filed under Col-6. The estimated rate column 05 is left blank since the same is not prepriced by MES.)
SEWAGE DISPOSAL
M&L for cutting into existing manholes for connecting new drains 200mm dia, making good to pipe and rendering, cutting out existing benching for and forming branch channel (1/2 round or ¾ section) in cement concrete 1:2:4 type B-1 smooth finished and reforming benching as required.
INTERNAL WATER SUPPLY
S&F CP health faucet (ABS body) mild steel chromium plated suitable for 15mm dia pipe with 1.25 metro long Flexible Tube & Wall Hook complete all as specified and as directed by Engineer-in-charge (Make : Pryag, Seiko, Jaquar)
EXTERNAL WATER SUPPLY
Material and Labour for Construction of brick masonry valve pit chamber of inner dimension 90x90x90cms suitable for gate valve upto 50mm size, with PCC 1:4:8 type D-2 as in foundation, brick work with sub class B bricks in cm 1:4, rendering 15mm thick in CM 1:4, coping with PCC 1:2:4 type B-1, incl necessary earth work etc complete with and including 2mm thick MS sheet cover with angle iron 50x50x6 mm frame work including two coats of synthetic enameled paint over a coat of red oxide primer with making provision for locking arrangements etc complete all as specified and directed by engr- In- Charge.
EXTERNAL ELECTRIC SUPPLY
Supply, installation, testing and commissioning LT panel board suitable for working on 3 phase, 4 wire, 415 volts, AC, 50Hz outdoor type, cubicle, floor mounted, free standing, dust and vermin proof, air ventilation, factory fabricated made out of 3.2mm thick CRCA sheet duly powder coated and shall be CPRI approved and as approved by GE. The Panel shall have front and rear opening, locking arrangement, bus bar chamber and switch gear compartment, hinged door with rubber gasket, bottom cable entry holes for incoming and out going cables, earthing terminals, affix danger notice plate, aluminium bus bar duly covered with heat shrink sleeves colour coded duly fixed on DMC/SMC insulators, aluminium strip connection from bus bar to outgoing MCCBs and copper conductor cable of adequate size for MCBs, housed in a separate bus bar chamber and control wiring adequate size and length, outgoing MCCBs shall have extended bus bar links. Panel mounted on 50x50x5mm size MS angle iron frame duly painted including PCC 1:2:4 Type B1 using 20mm graded stone aggregate in foundation, design subject to approved by GE as per site requirement. The minimum size of panel is 1500x450x1800mm, minimum clearance from ground level is 450mm including removing old unserviceable item complete all as specified and directed. Panel shall be comprising of following:-
(a) MCCB 100Amps, FP, 16 KA, Adjustable type, 415 volts, 50Hz-1 Nos. (b) MCB 40 Amps, FP, 10 KA, 415 volts 50Hz-2 Nos. (c) MCB 32 Amps, FP, 10 KA, 415 volts, 50 Hz-10 Nos. (d) Digital voltmeter, with VSS-01 set, (e) Digital, Ammeter, with CTs & ASS-01 set. (f) LED phase indication lamps RYB-01 set. (g) Aluminium bus bar TPN 300 Amps rating -01 set. Note : (i) Contractor shall provide CPRI certification of the panel. (ii) All items incorporated in panel is ISI marked or IS specification. Make for MCCB :- Schneider/L&T/Legrand/Standard. Make for CT :- Nippen/AE, Make of LED Lamp :- Teknic, Make for amp meter and volt, meter :- AE/Kaycee
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.14 MB
82673-TD.pdf
Tender Documents • 1.75 MB
BOQ_820319.xls
BOQ • 0.50 MB
DRAWINGS-82673_compressed.pdf
Additional Documents • 30.84 MB
date3.pdf
PDF • 0.30 MB
date2.pdf
PDF • 0.30 MB
dateamendment-82673.pdf
PDF • 0.29 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .