Tender Value
₹2 Cr
EMD Value
₹4 L
Closing Date
9 Oct 2026, 2:00 pm
SE PWD Ghy Bldg Circle-II Chandmari Ghy-3
O/o the SE PWD Ghy Bldg Circle-II Chandmari Ghy-3
Infrastructure Development of Community Development Centre of Uttar Purvanchal Lok Kalyan Samiti at Borbanghsar, North Guwahati, Kamrup, Phase-II
2026_PWBNH_53918_1
SE/BII/Tech/CDC/Lokalyansamiti
Open Tender
Civil Works - Building
Item Wise
180 days
Borbanghsar, North Guwahati
Please refer Tender documents.
3 documents required · 3 mandatory
₹4,000
₹4 L
Yes
O/o the SE PWD Ghy Bldg Circle-II Chandmari Ghy-3
15 Sept 2026
15 Sept 2026
9 Oct 2026
15 Sept 2026
9 Oct 2026
19 Sept 2026
19 Sept 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Excavating, supplying and filling of local earth (including royalty) by mechanical transport upto a lead of 5km also including ramming and watering of the earth in layers not exceeding 20 cm in trenches, plinth, sides of foundation etc. complete. | - | cum | - | - |
| 2 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more. | 50,771.7 | kg | - | - |
| 3 | Providing, driving with hydraulic piling rigs with power units and
installing driven cast-in-situ reinforced cement concrete piles of grade M-25 of specified diameter and length below the pile cap, to carry safe working load not less than specified, excluding the cost of steel reinforcement but including the cost of shoe and the length of pile to be embedded in the pile cap etc. all complete. (Length of pile for payment shall be measured from top of shoe to the bottom of pile cap) :
450 mm dia piles | 4,050 | metre | - | - |
| 4 | Vertical load testing of piles in accordance with IS 2911 (Part IV)
including installation of loading platform by Kentledge/Anchor piles method and preparation of pile head or construction of test cap and dismantling of test cap after test etc. complete as per specification & the direction of Engineer in-charge.
Note: 1. Initial and Routine Load Test shall not be carried out by
Dynamic method of testing.
Note: 2. Testing agency shall submit the design of loading platform for the approval of Engineer-in-charge.
Single pile upto 50 tonne Safe capacity Initial test (Test Load 2.5 times the Safe capacity) | 1 | Per test | - | - |
| 5 | Vertical load testing of piles in accordance with IS 2911 (Part IV)
including installation of loading platform by Kentledge/Anchor piles method and preparation of pile head or construction of test cap and dismantling of test cap after test etc. complete as per specification & the direction of Engineer in-charge.
Note: 1. Initial and Routine Load Test shall not be carried out by
Dynamic method of testing.
Note: 2. Testing agency shall submit the design of loading platform for the approval of Engineer-in-charge.
Single pile upto 50 tonne Safe capacity
Routine test (Test Load 1.5 times the Safe capacity) | 2 | per test | - | - |
| 6 | Preparation of site for placement of the drilling rig including excavation of mud pit, circulation drain, collection chamber etc. all complete as directed. | 1 | Each DTW | - | - |
| 7 | Drilling with drill bit in overburden portion of soil formation including collection of soil sample at every 3.0 m depth wherever there is a change of strata in sample boxes with distinguishing marks upto the depth of rock formation and withdrawing the drill bit for lowering casing as directed with 245mm to 300 mmm dia drill bit. | 95 | Metre | - | - |
| 8 | Casing / sinking / lowering of 200 mm dia MS pipe including cost of pipe and labour charge for casing, welding of joint by welding machine and sinking by drilling rig in portion all complete as
directed by department. | 100 | Metre | - | - |
| 9 | Drilling with drilling rig using D.T.H. in all kinds of rock formation including collection of sample at every 3.0 m depth of boring or wherever there is a change of strata in sample boxes with
distinguishing marks upto a required depth of boring along with breaking rock fracture for desired discharge, withdrawing drilling rod and finishing the borehole by ramming upto a reqired
dia upto the bottom and washing the well as per direction of the department all complete including testing of yield and drawdown of SWL of the DTW in presence of Engineer / incharge with submission of all report and lithology of the well as directed by the department. | 145 | Metre | - | - |
| 10 | Supplying, assembling, lowering and fixing in vertical position in bore well unplasticized PVC medium well screen (RMS) pipes with ribs, conforming to IS: 12818, including hire & labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer-in-charge.
100 mm nominal size dia | 240 | metre | - | - |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 2.68 MB
SBD.pdf
Tender Documents • 5.96 MB
BOQ_84689.xls
BOQ • 0.34 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .