Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹22.0 LAccepted-AOC B 3 105 PASCHIM VIHAR NEW DELHI 110063 | WEST | DELHI | 110063 | L1 | Accepted-AOC Lowest Bidder | |
| 2 | L2₹27.2 L+₹3.8 L (16.0%)Rejected-Finance RZ 1 7 167 GALI NO 6 DURGA PARK NASIRPUR SOUTH WEST DELHI DELHI 110045 | SOUTH WEST | DELHI | 110045 | L2 | Rejected-Finance Other than Lowest | |
| 3 | L3₹27.7 L+₹4.3 L (18.2%)Rejected-Finance RZ 18 260 WEST SAGARPUR NEAR MCD SCHOOL NEW DELHI 110046 | NEW DELHI | NEW DELHI | DELHI | 110046 | L3 | Rejected-Finance Other than Lowest | |
| 4 | L4₹31.5 L+₹8.0 L (34.2%)Rejected-Finance 19 62 1ST FLOOR WEST MOTI BAGH SARAI ROHILLA NEW DELHI 110035 | NEW DELHI | NEW DELHI | DELHI | 110035 | L4 | Rejected-Finance Other than Lowest | |
| 5 | L5₹31.8 L+₹8.3 L (35.6%)Rejected-Finance | L5 | Rejected-Finance Other than Lowest |
Tender Value
₹45.1 L
EMD Value
₹90,120
Closing Date
26 Jan 2023, 6:00 pmClosed
GE UTILITY PLANT AND MACHINERY DELHI CANTT-10
GE UTILITY PLANT AND MACHINERY KIRBY PLACE DELHI CANTT-10
REPAIR MAINTENANCE OF TOWER ACS MISC OTHER AIR CONDITIONING WORKS AND SUMMER APPLIANCES AT NAVAL OFFICERS MESS UNDER GE (U) PM DELHI CANTT-10.
2022_MES_571983_1
GE(U)/PM/D-66/2022-23
Open Tender
Electrical and Maintenance Works
Item Rate
240 days
DELHI CANTT-10
MES contractor enlisted under class D category c(i) having deposited standing security of Rs 100000 with department. Contractor not enlisted in MES should meet the MES enlistment criteria corresponding to appropriate class and category.
6 documents required · 6 mandatory
₹500
Yes
GE UTILITY PLANT AND MACHINERY DELHI CANTT-10
₹90,120
Yes
15 Mar 2023
29 Dec 2022
28 Jan 2023
29 Dec 2022
26 Jan 2023
12 Jan 2023
Amount
Taking down of tower type AC 4 TR Capacity including cleaning of cooling coil, air filters , condenser, compressors, fan motor etc with vacuum cleaner OR cleaning solution including checking the serviceability of electrical/electronic circuits relays, wiring kit, thermostat switches knobs, remote control unit including PCB, fan, blower, etc, changing connections from heating mode to cooling mode or vice-versa and keeping the AC unit in satisfactory working condition after necessary servicing/ repair/ replacement of defective spares as required and refixing the same in existing position complete all specified and as directed by Engineer-in-Charge. Notes :- (i) Replacement of defective spares for making the AC units in satisfactory working condition will be measured & paid separately under relevant items and Labour charges for taking out old spares & refixing of new spares shall deemed to be included in unit quoted rate. (ii) Penalty will be charged for not attending complaint from 12 Hours to 24 hours Rs. 500/- each complaint. Further if complaint not attended and rectified within 24 hours after intimation (Intimation will be given by message/whats app/mail by mentioning time of complaint, for that contractor has to submit his authorised reps details for receiving complaint) of complaint, failing which same will be got rectified through spot quotation by job order by any other agency and double of the job order amount to be deducted from contractors dues.
Supply and fixing Baimetal overload relay 6-10A. (Make:- L &T /ABB/ Seimens )
Supply and fixing Contractor MNX 12. ( Make:- L &T / ABB/ Seimens )
Supply & fixing Condenser fan blade of Aluminium for tower type A.C of Capacity 4 TR as per Existing size as specified and directed by engineer-in-charge.
Supply and fixing In Repair single phase preventer VSP 1. ( Make:- L &T / ABB/ Seimens )
Disconnecting the main printed circuit board (PCB) and repair the PCB with electric accessories and sensors as per existing suitable for Tower AC of capacity 4 TR and refixing it complete with all testing and commssioning as directed by Engr-in-Charge.
Supply & fixing in repairs of suction valve set of size 15.9mm (5/8'') for Tower 4 TR capacity complete all as directed by Engr-in-Charge. Note:- Supply & filling of refrigerant gas shall be measured and paid under relevent item.
Supply & fixing in repairs of Discharge valve set of size 9.52 mm (3/8'') for Tower 4 TR capacity complete all as directed by Engr-in-Charge. (Make:- LG/ Voltas/ Blue Star/ Hitachi). Note:- Supply & filling of refrigerant gas shall be measured and paid under relevent item.
Supply & fixing in repairs of Expansion valve for tower type AC of capacity 4 TR complete all as directed by Engr-in-Charge. (Make:- Danfos, Emerson, Temsuch)
Taking down unserviceable reversible valve for split AC of capacity 1.5TR and supply & fixing new reversible valve with solenoid coil including required different copper pipe with PCB and remote alteration/modification complete all as specified and directed by Engr-in-charge. (Make:- LG/ Voltas/ Blue Star/ Hitachi) (Note 01:- Supply & filling of refrigerant gas shall be measured and paid under relevent item.) (Note 02:- various size copper pipe used for this to be included in above quoated artes.) (Note 03:- Any Alteration or modifation including electronic component required in PCB and Remote to be included in above quoated rates.) Note 04:-carryout the pressure test of refrigeration system, detecting leakage and charging the refrigerant gas of matching description as per existing including soldering and brazing of leaking copper tubing complete all as specified and directed to be included in above mentioned rates.
ditto- all as per item No. 10 above but window type Air Conditioner of capacity 1.5 TR.
ditto- all as per item No. 10 above but window type Air Conditioner of capacity 2 TR.
ditto- all as per item No. 10 above but spilt type Air Conditioner of capacity 2 TR.
Disconnecting from mains and taking out existing unserviceable sealed compressor unit from the Tower type Air Conditioner of Cap 4 Ton, of any make any type from any location
Supply , Installing and testing of new sealed unit compressor 4TR for Tower type Air Conditioner of Cap 4 Ton alongwith test certificate from manufacturer including cleaning and removing dust/dirt from the cooling coil condenser coil with necessary modification of capillary tube etc & Charging of Gas R-22/R-134A/R-410 and commissioning complete all as specified & directed by Engg-in-Charge. (Make:- Emerson /Tecumseh/ Danfos) Note :-1. Gas charging shall be paid spepartely under relevent item. 2. Transportation Charges from site to trade workshop and back to original location after repair shall be deemed to be included in unit rate quoted above.
Supply & fixing in repairs of air blower motor copper wounded for 4TR capacity tower AC as per existing complete all as specified & as directed. (Make-AUE/Crompton Greaves/Cool Master.)
Disconnecting the mains and taking out the unserviceable condenser coil of Tower AC of capacity 4TR of any make from any location and supply, fixing and testing new condenser coil as per existing size & patterns for complete all as specified & as directed. (Make:- Voltas/Carrier/LG)
Supply & fixing in repairs of evaporator/cooling coil for tower type Air Conditioner of capacity 4 TR of existing make and size complete all as specified & as directed by Engr-in-Charge.
Dismantling and removing defective burnt blower unit motor of any capacity and make of indoor units of tower type AC of capacity 4 TR capacity rewinding the motor with enamel copper binding wire of existing guage and size including replacement of worn out motor bearing etc, refixing and testing all as directed.
Dismantling and removing defective burnt outdoor unit motor of any capacity and make of indoor units of tower type AC of capacity 4 TR capacity rewinding the motor with enamel copper binding wire of existing guage and size including replacement of worn out motor bearing etc, refixing and testing all as directed.
Material and labour for applying POP gypsum paste in hole of wall as directed and specified by engineer in charge.
Dismantling and Refixing the Split AC of 1.5/2 TR Including Drilling of holes into a brick wall for connecting Indoor with OutDoor Unit’s pipes and Connecting indoor and outdoor units with copper pipes and installation of drainage pipes and Fixing Outdoor unit on separately ODU stand, Temperature & gas pressure testing,gas charging, Carpentry work, Plumbing, masonry & white cementing Note : Drain Pipe, Copper of required size, Refrigenent gas , Outdoor stand , power plug, MCB and Copper wire to be paid under relevent item
Material and labour in repair for MS iron cross arms, bracing supports , clamps and back plates fabricated from strctural steel sections including nuts, bolts,washers, welding bending cold or hot , drilling holes for bolts in any shape or size for outdoor stand/ desert cooler stand/ tower ac stand (indoor / Outdoor) as indicated and inclusive of one coat of zinc cromate primer , one under coat & one finishing coat & good quality of aluminium paint all as specified and directed.
Supply & fixing in Repair Outdoor Unit (ODU) Stand for 4 TR Type tower AC as directed and specified by engineer in charge.
Supply & fixing in Repair Outdoor Unit (ODU) Stand for 1.5TR/ 2 TR Type split AC as directed and specified by engineer in charge.
Supply & fixing heavy duty hard copper pipe 10mm (3/8") dia/ bore complete including insulation brazing, welding, nuts, bolts and screws of required size including taking down old unserviceable one complete all as specified and directed by Engr-in-Charge. (Make:- Maxflow/mandev/ rajco)
ditto- all as per item No. 26 above but copper pipe 15mm (5/8") dia/ bore.
ditto- all as per item No. 26 above but copper pipe 12mm (1/2") dia/ bore.
ditto- all as per item No. 26 above but copper pipe 6mm (1/4") dia/ bore.
Taking down unserviceable insulation for copper pipe, supply and fixing new insulation for copper pipes suitabale for tower/Split AC of capacity from 1.5 to 4.0 TR all as specified and directed by Engineer-in-charge.
Taking down unserviceable UPVC drain pipe and supply & fixing new PVC drain pipe 15 mm dia for Split/window AC all as specified and directed by Engineer-in-charge. (Make:- Prayag/ Supreme/ Prince.)
Taking down unserviceable UPVC drain pipe and supply & fixing new PVC drain pipe 20 mm dia for Split/window AC all as specified and directed by Engineer-in-charge. (Make:- Prayag/ Supreme/ Prince.)
Taking down unserviceable UPVC drain pipe and supply & fixing new PVC drain pipe 25 mm dia for Split/window AC all as specified and directed by Engineer-in-charge. (Make:- Prayag/ Supreme/ Prince.)
Supply and filling refrigerant gas R-22/R-32/R-410A/R-134 in window type /Split Type AC/ Tower type unit of capacity 1.5/2//4 TR. (Make : Mefron/Floron/ Refron.)
Material and labour for detecting the leakage of gas at any location and rectifying the defect to stop the leakage by gas welding or by any other means including cutting & brazing of copper tubes testing and commissioning complete in satisfactory working condition all as specified and as directed.
Material and labour for sub main wiring with two runs of single core 6 Sqmm (nominal area) PVC insulated copper conductor FRLS (conforming to IS-694), multistranded, unsheathed 1100 volts grade in PVC casing caping (heavy grade) of adequit size with all fittings and casing caping accessories of surface type including one run 6 Sqmm single core unsheathed multistranded copper conductor cable FRLS (conforming to IS-694) as earth wire including taking down old unservisible sub main wiring complete all as specified and as directed. (Make of cable:- NICCO / FINOLEX / RR KABEL/ HAVELL'S/ POLYCAB / KEI INDUSTRIES LTD and make of Casing caping:- FINOLEX / PAYAL/KALINGA/ PRESTO PLAST.)
Material and labour for sub main wiring with two runs of single core 4 Sqmm (nominal area) PVC insulated copper conductor FRLS (conforming to IS-694), multistranded, unsheathed 1100 volts grade in PVC casing caping (heavy grade) of adequit size with all fittings and casing caping accessories of surface type including one run 4 Sqmm single core unsheathed multistranded copper conductor cable FRLS (conforming to IS-694) as earth wire including taking down old unservisible sub main wiring complete all as specified and as directed. (Make of cable:- NICCO / FINOLEX / RR KABEL/ HAVELL'S/ POLYCAB / KEI INDUSTRIES LTD and make of Casing caping:- FINOLEX / PAYAL/KALINGA/ PRESTO PLAST.)
Supply and fixing in repairs of metal clad socket outlet with single pole and neutral enclosure with two pin and earth plug socket complete with one single pole MCB 32 Amps including taking down old unserviceable metal clad socket complete all as specified and as directed. (Make:- Schneider/ Legrand/ ABB/ Siemens/ L & T)
Supply and fixing in repairs of MCB TPN 415 volts 32 Amps, 16 kA, 'C' curve complete all as specified and as directed. (Make:- Schneider/ Legrand/ ABB/ Siemens/ L & T)
Supply & fixing in repair metal clad socket of 20 Amps complete all as specified & as directed. (Make:- Schneider/ Legrand/ ABB/ Siemens/ L & T)
Supply & fixing in repairs metal clad plug with two pin of capacity 20 Amps complete all as specified & as directed. (Make:- Schneider/ Legrand/ ABB/ Siemens/ L & T)
Supply & fixing in replacement only Basic all purpose surface and wall mounted LED batten with polycarbonate housing & integrated electronic driver LED tube light fitting 20 watt including LED tube, 230 volt complete all as specified and directed. (Make :Havells cat part No LUMILINEBS9WLED830SPCWH or equivalent model of make Phillips / Surya Roshni Ltd / Bajaj/ Crompton Greaves/ C & S Electric)
Disconnecting the unserviceable PCB of any make invert AC of capacity 1.5/2 TR and refixing the same after necessary repair of PCB for satisfactory functioning of the AC unit Complete all as specified and as directed.
Dismantling of existing repairable Non-Inverter/inverter Refrigerators of any make and from its position after disconnecting electric connections, transporting from site to contractor's workshop for carrying out repairs and renewal/replacement of parts, reassembling and transporting back to the site including installation of the same on the same location and making electric connection etc, all as specified and directed by Engineer-in-Charge. Note :- 1. Replacement of defective spares for making the Refrigerator units in satisfactory working condition will be measured & paid separately under relevant items and Labour charges for taking out old spares and fixing of new spares shall deemed to be included in unit rate quoted.
Supply only capillary tube of existing size including necessary brazing suitable for 165-310 ltrs capacity refrigerator all as specified and directed. (Make:- As per sample)
Supply only overload protector relay suitable for 165-310 ltrs capacity refrigerator all as directed. (Make:- Renutrol/ Sri Ram/ Microtech)
Supply only thermostat suitable for 165-310 ltrs capacity refrigerators all as directed. (Make:-HONEY WELL/ INDFOSS/ RENUTROL /SIEMENS/ DASPASS.)
Supply only freezer door with spring of refregierators of any capacity all as directed. (Make : Suitable for Whirlpool/ LG/Samsung/ Godrej make refrigerator).
Supply only vegetable basket with glass suitable for 165-310 ltrs capacity refrigerators all as directed. (Make : Suitable for Whirlpool/ LG/Samsung/ Godrej make refrigerator).
Supply only PVC defrost tray as per sample suitable for 165-310 ltrs capacity refrigerators. (Make : Suitable for Whirlpool/ LG/Samsung/ Godrej make refrigerator).
Material and labour for inspection from the authorised repair centre of respective company ( LG/Whirlpool/Samsung) to find out the defects in compressor, PCB, and carrying out the required repair.
Supply and filling refrigerant gas R-134/ R-600 in water co0ler/ refrigerator/ deep freezer of various capacity. (Make :Honeywell/ Sterlin/Duplon.)
Supply and fixing in replacement inverter type compressor for refrigerators of capacity 225 to 310 ltrs. Make:Emerson/ Tecumseh/LG
Supply and fixing in replacement PCB compatible suitable for inverter type refrigerators of capacity 225 to 310 ltrs.
Material and labour for dismantling the existing window type air conditioner complete of capacity 1.5/ 2.0 TR and refixing to any other location after servicing including cutting of window grills, covering the open space of old location and new place of fitting complete all as specified & as directed.
Supply and fixing in replacement 4mm thick wooden play for exposed space for window AC complete as specifed and directed.
Supply and fixing in replacement wood wollen pad of suitable size for 24” sweep desert cooler complete all as specified and directed 01 Set comprising of 3 Nos of pads (Make:- As per sample.)
Supply and fixing in replacement only 3 pin plug top 15 Amp for desert cooler complete all as specified and directed. (Make-Anchor/Kinjal/Havells)
Supply and fixing in replacement pump motor 230 Volts, single phase, AC suitable for Plastic body/Steel body Desert cooler complete all as specified & as directed. (Make- cool master/ Crompton Greaves/ Khaitan/ indcool.)
Supply and fixing in replacement of desert cooler kit fan motor, single speed, 230 V, 50 Hz of capacity 90 Watt 1450 RPM, copper wounded including nuts bolts for fixing complete all as specified and directed. (Make : Crompton Greaves/Usha/Khaitan)
Supply and fixing in replacement Desert cooler exhaust fan motor, single speed, 230 V, 50 Hz of capacity 150 Watt 1400 RPM, copper wounded including nuts bolts for fixing including taking down old unserviceable one complete all as specified and directed. (Make- cool master/ Crompton Greaves/ Khaitan/ indcool.)
Taking down of split type AC 1.5/2 TR Capacity including cleaning of cooling coil, air filters/plasma filters etc, (Indoor unit), condenser, compressors, fan motor etc,(Out door unit) with vacuum cleaner OR cleaning solution including checking the serviceability of electrical/electronic circuits relays, wiring kit, thermostat switches knobs, Remote control unit including PCB, fan, blower, etc., changing connections from heating mode to cooling mode or vice-versa and keeping the AC unit in satisfactory working condition after necessary servicing/ repair/ replacement of defective spares as required and refixing the same in existing position complete all specified and as directed by Engineer-in-Charge.
Taking down of Window type AC 1.5/2 TR Capacity including cleaning of cooling coil, air filters , condenser, compressors, fan motor etc with vacuum cleaner OR cleaning solution including checking the serviceability of electrical/electronic circuits relays, wiring kit, thermostat switches knobs, remote control unit including PCB, fan, blower, etc, changing connections from heating mode to cooling mode or vice-versa and keeping the AC unit in satisfactory working condition after necessary servicing/ repair/ replacement of defective spares as required and refixing the same in existing position complete all specified and as directed by Engineer-in-Charge. Notes for Ser Item No 76 & 77 :- (i) Replacement of defective spares for making the AC units in satisfactory working condition will be measured & paid separately under relevant items and Labour charges for taking out old spares & refixing of new spares shall deemed to be included in unit quoted rate. (ii) Penalty will be charged for not attending complaint from 12 Hours to 24 hours Rs. 500/- each complaint. Further if complaint not attended and rectified within 24 hours after intimation (Intimation will be given by message/whats app/mail by mentioning time of complaint, for that contractor has to submit his authorised reps details for receiving complaint) of complaint, failing which same will be got rectified through spot quotation by job order by any other agency and double of the job order amount to be deducted from contractors dues.
Supply only Running capacitor 36+6 MFD. (Make:- Epcos/ Usha/ Keltron.)
Supply only Running capacitor 45+5 MFD. (Make:- Epcos/ Usha/ Keltron.)
Supply only Running capacitor 50+6 MFD. (Make:- Epcos/ Usha/ Keltron.)
Supply only Starting capacitor 80-100 MFD. (Make:- Epcos/ Usha/ Keltron.)
Supply only Starting capacitor 100-120 MFD. (Make:- Epcos/ Usha/ Keltron.)
Supply only Starting Relay 1622. (Make:- Hytech/ Renutrol/ Sri Ram/Microtech.)
Supply only Starting Relay 2000. (Make:- Hytech/ Renutrol/ Sri Ram/Microtech.)
Supply only Overload Relay. (Make:- Hytech/ Renutrol/ Sri Ram/Microtech.)
Supply only Thermostat switch 2059/2064/2054. (Make :- Indfos/ Renutrol).
Supply only Condenser fan blade for Window type A.C of Capacity 1.5/2 TR made of Plastic.
Supply only Condenser fan blade for spilt Type A.C of Capacity 1.5/2 TR made of Plastic.
Supply only main printed circuit board (PCB) with electric accessories and sensors suitable for split AC of capacity 1.5/2 TR as directed by Engr-in-Charge.
Supply only main printed circuit board (PCB) with electric accessories and sensors suitable for window AC of capacity 1.5/2 TR as directed by Engr-in-Charge. Note for item No 78 to 90:- Materials of item Nos 78 to 90 to be incorporated in item Nos 76 & 77 here-in-before.
Supply & fixing in repairs plastic louvers (Front panel) for Window AC 1.5/2 TR complete all as directed by Engr-in-Charge.
Supply & fixing in repairs of capillary tube for Split/ Window type AC of capacity 1.5/2 TR complete all as directed by Engr-in-Charge. (Make:- As per Sample)
Supply & fixing in repairs of capillary filter for Split/ Window type AC of capacity 1.5/2 TR complete all as directed by Engr-in-Charge. (Make:- As per Sample)
Disconnecting from mains and taking out existing unserviceable sealed compressor unit from the Split/window type Air Conditioner of Cap 1.5/2 Ton, of any make any type from any location as directed and specifed.
Supply , Installing and testing of new sealed unit compressor for window type Air Conditioner of Capacity 2 TR with necessary modification capillary tube etc & Charging of Gas R-22/R-410a/R-32 and commissioning complete all as specified & directed by Engg-in-Charge. (Make:- Emerson /Tecumseh/ LG) Note :-1. Gas charging shall be paid spepartely under relevent item. 2. Transportation Charges from site to trade workshop and back to original location after repair shall be deemed to be included in unit rate quoted above.
ditto- all as per item No. 81 above but window type Air Conditioner of Capacity1.5 TR. (Make:- Emerson /Tecumseh/ LG)
ditto- all as per item No. 81 above but spilt type Air Conditioner of Capacity 2 TR. (Make:- Emerson /Tecumseh/ LG)
ditto- all as per item No. 81 above but spilt type Air Conditioner of Capacity 1.5 TR. (Make:- Emerson /Tecumseh/ LG)
Supply & fixing in Replacement of Indoor Air blower motor for Split 1.5 TR & 2 TR capacity complete all as specified & as directed. (Make-AUE/Crompton Greaves/Cool Master.)
Supply & fixing in replacement of copper wounded condenser fan motor for Split type AC of 1.5 TR & 2 TR capacity outdoor units complete all as specified & as directed. (Make-AUE/Crompton Greaves/Cool Master.)
Disconnecting the mains and taking out the unserviceable condenser coil of window type AC of capacity 1.5/ 2TR of any make from any location and supply, fixing and testing new condenser coil as per existing size & patterns for complete all as specified & as directed. (Make:- Voltas/Carrier/LG)
ditto- all as per item No. 87 above but spilt type Air Conditioner Capacity 1.5/ 2 TR. (Make:- Voltas/Carrier/LG)
Supply & fixing in repairs of evaporator/cooling coil for window type Air Conditioner of capacity 1.5/ 2TR of existing make and size complete all as specified & as directed by Engr-in-Charge. (Make:- As per Sample)
ditto- all as per item No. 89 above but spilt type Air Conditioner Capacity 1.5/ 2 TR. (Make:- As per Sample)
Supply and fixing in repairs of 1.5TR capacity split type Air Conditioner outdoor kit including condenser coil, blower motor, chasis, base plate complete set except compressor complete all as specified & as directed by Engr-in-Charge. (Make:- Nepoleon/ Commander/ Camipro/ Skoda.)
ditto- all as per item No. 91 above but spilt type Air Conditioner of capacity 2 TR. (Make:- Nepoleon/ Commander/ Camipro/ Skoda.)
Taking down unserviceable indoor unit of split type AC of any make and supply & fixing new indoor unit complete set suitable for 1.5 TR capacity complete all as directed by Engr-in-Charge. (Make:- LG/Carrier/Voltas.)
ditto- all as per item No. 93 above but spilt type Air Conditioner of capacity 2 TR. (Make:- LG/Carrier/Voltas.)
Supply and fixing in repairs of 2 TR capacity window type AC kit including condenser coil, cooling coil, front grill blower motor, chasis, base plate complete set except compressor. (Make:- Nepoleon/ Commander/ Speed.)
Supply and fixing in repairs of 1.5 TR capacity window type AC kit including condenser coil, cooling coil, front grill blower motor, chasis, base plate complete set except compressor. (Make:- Nepoleon/ Commander/ Speed.)
Supply and fixing in replacement Honeycomb based cooler pad for air washer of 50mm thickness size complete all as specified and directed.
Taking down carefully existing surface/concealed unserviceable copper/Aluminium point wiring (light, fan socket or power) complete with fittings such as switches, ceiling rose, lamp holder, regulators, sockets, F/Tube/Sketch light fittings, wooden terminal box, plastic laminated sheet cover, from Teak Wood batten including Teak Wood batten or PVC conduits complete all as specified & as directed.
Material and labour for point wiring using 1.50 sqmm size FRLS, PVC insulated, unsheathed 1100 volts grade single core multi-stranded copper conductor cable in proper colour coding drawn into and including non metallic rigid PVC conduit medium grade (not less than 20 mm dia) for wall and 25mm PVC medium grading grade casing and caping in the ceiling wherever required with and including its all necessary fittings and accessories fixed concealed, sunk cast iron or 1.2 mm thick pressed steel terminal box for mounting fittings and covered with 3 mm thick white bakelite / laminated hard glossy surface sheet top cover fixed with brass screws and cup washers including one continuous run of PVC insulated (green colour) 1.50 sqmm size FRLS stranded copper conductor cable as in earth wire and connecting all metal parts to common earth dolly for one light / Fan / exhaust fan / Bell point controlled by one, one way switch complete all as specified & directed by Engr-in-Charge. (Make of cable:- NICCO / FINOLEX / RR KABEL/ HAVELL'S/ POLYCAB / KEI INDUSTRIES LTD) (Make of Conduit:- FINOLEX / PAYAL/KALINGA/ PRESTO PLAST)
All as per item No. 99.00 above but for one 5 pin 5/6 Ampere socket outlet point controlled by one, one way switch on the same board complete all as specified and directed by Engr-in-Charge.
All as per item No.99.00 above but for one 5 pin 5/6 Ampere socket outlet point controlled by one, one way switch on independant board complete all as specified and directed by Engr-in-Charge.
Material and labour for point wiring for one 15/16 Ampere socket outlet independent point using 2.50 sqmm FRLS size (Nominal cross sectional area), PVC insulated, unsheathed 1100 volts grade single core multi-stranded copper conductor cable in proper colour coding drawn into and including non metallic rigid PVC conduit medium grade concealed (not less than 25 mm dia) for wall and 25mm PVC medium grading grade casing and caping in the ceiling wherever required with and including its all necessary fittings and accessories fixed concealed, sunk cast iron or 1.2 mm thick pressed steel terminal box for mounting fittings and covered with 3 mm thick white bakelite / laminated hard glossy surface sheet top cover fixed with brass screws and cup washers including one continuous run of PVC insulated (green colour) 2.50 sqmm FRLS size stranded copper conductor cable as in earth wire and connecting all metal parts to common earth dolly complete all as specified and directed. (Make of cable:- NICCO / FINOLEX / RR KABEL/ HAVELL'S/ POLYCAB / KEI INDUSTRIES LTD Make of Conduit:- FINOLEX / PAYAL/KALINGA/ PRESTO PLAST)
Supply & fixing in repair socket out let 2 in 1, 3/5 Pin, 15/16 Ampere, 230V AC, flush type complete all as specified and as directed. (Make : Anchor / Cona / Kinjal / Havells)
Supply & fixing in repair ceiling rose, 3 phase, PVC / polycarbonate, surface type, 65mm x 50mm, insulated body, three terminals complete all as specified and as directed. (Make : Anchor / Ess Ess Kay / Havells/ Cona)
Supply & fixing in repair modular switch one module, 15/16 Amp, one way, 230 volts AC complete all as specified and as directed by Engr-in-Charge. (Make : Anchor / Cona / Crabtree / Legrand / Indo Asian (Glint))
Supply & fixing in repair of modular socket outlet (two module) 5/6 amps, 2 in 1, 2 & 3 pin combined, 230 volts AC complete all as specified and as directed by Engr-in-Charge. (Make : Anchor / Cona / Crabtree / Legrand/ Indo Asian (Glint) )
Supply & fixing in repair modular socket out let (two module), 2 in 1, 3 Pin suitable for 5/6 Amp and 3 Pin suitable 15/16 Amp combined, 230 volts AC complete all as specified and as directed by Engr-in-Charge. (Make : Anchor / Crabtree / Legrand / Indo Asian (Glint)
Supply & fixing in repair of electric ding dong bell, 230 volt AC, single pole, complete all as specified and as directed by Engineer-in-Charge. (Make :- Anchor / Cona / Wipro / Bajaj/Havells)
Supply & fixing in repair of flush type bell push, 5 Amps complete all as specified and as directed by Engr-in-Charge. (Make : Anchor / Cona / Kinjal / Havells)
Supply & fixing in repair of lamp holder, PVC/polycarbonate type, insulated body with back plate of batten fitting complete all as specified and as directed. (Make : Anchor / Ess Ess Kay / Plaza / Havells)
Supply & fixing in repair of stepped type 5 steps 100 watts electronic fan regulator flush type on the existing phenolic laminated sheets etc as required all as specified and as directed. (Make : Anchor / Havells / Usha / Crompton / Bajaj)
Supply & fixing in repair of Modular Fan regulator step type, 1 Module size complete all as secified and as directed. (Make: Havells / Legrand/ Crabtree/ Anchor)
Disconnecting from mains/taking out existing unserviceable/defective Servo Voltage of capacity 10 KVA of any size, type, and make removing from foundation and shifting from ground floor to II/III floor of building complete all as specified and as directed.
Material and labour for painting outside body with synthetic enamel paint of existing tint/colour of 10 KVA voltage stablizer complete all as specified and as directed.
Material and labour for on line Dehydration/filteration of Servo Voltage Stablizer oil including filteration using automatic centrifuging machine minimum three cycles to achieve dielectric strength 40 to 60 KV breaking capacity at 2.5mm gap by absorbing and abolishing all sludge particles as per BS-66-1963 including topping up with new transformer oil as required complete all as specified and as directed. Note- (i) Centrifuging Machine with all T&P & testing machine of oil required for dehydration shall be arrange by contractor. (ii) Oil required for topping up the stablizer will be measured & paid separately as supply only under respective item of this Sch.
Supplying and filling/topping up transformer oil low viscocity, dielectric strength 35 to 40 KV breaking voltage for topping up servo voltage stablizers duly centrifuging including filter action by using automatic centrifuging machine to achieve min 35 to 40 KV breaking capacity at 4 mm gap by absorbing and abolishing all sludge particles for use as per BS-B-66-1983 complete all as specified and as directed..
Supply, installation, testing and commissioning in replacement complete indoor unit for tower type split AC of 4 TR, inclusive of blower motor, blower, PCB circuit ,wiring kit with cooling coil etc, suitable for R-410A/R-32 Gas, including all copper tubing of required size & electrical cabling up to 5 metre all as required as per site complete all as specified and directed. Make: Lloyd /Carrier/ Blue star/Voltas/Hitachi. Indoor Unit Technical specification- Nominal cooling cap -3.5 TR, Indoor fan motor-300 watt, Dimension(WXDXH): 55 cm X 35 cm X 180 cm. Gross weight: 60-70 KG, Operating temp.- > 17 °C, Controller-Remote Control, IDU Noise (dB)-52 dB, Air Flow (m³/h)-1680 m³/h, Input Power (W)-5490 W, Cooling Capacity (W)13500 W. Note :- Old taking down indoor unit of any capacity and size shall be deposited to MES store yard from existing location. The rate include necessary transportation & Manpower to dismantling and transporting of the unit.
Supply, installation, testing and commissioning in replacement complete outdoor unit for Tower type split AC of 4 ton, without scroll compressor, suitable for R-410A/ R-32 Gas, condenser coil, wiring kit , condenser fan motor, condenser fan, terminal etc also making platform for outdoor unit with suitable size of fastener and MS frame work stand and making good the disturb surface including all copper tubing of required size, control wiring all as required as per site complete all as specified and directed. Make: Model No- GLT48B01AG of Lloyd or equivalent model of Carrier/ Blue star/Voltas/Hitachi. Outdoor Unit Technical specification- Power Supply- 3 phase, 380-415 Volt, 50 Hz, Outdoor fan motor-290 watt, Fan motor speed-830 RPM, Dimensions(WXDXH): 94.6 cm x 41.0 cm x 81.0 cm, Gross weight - 75-93 KG, Refrigerant piping-Max pipe lenght-20 mtr, Max difference in level-10 mtr Note :- The outdoor unit shall be replaced from roof of building of height 40-50ft. Note :- Old taking down Outdoor unit of any capacity and size shall be deposited to MES store yard from existing location. The rate include necessary transportation & Manpower to dismantling and transporting of the unit.
YASHVI ENGINEERS
P S TRADERS
SNOWY ENGINEERING INC
SEHGAL ELECTRICAL INDIA
Sai Enterprises
DP Traders
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.PDF
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .