Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.0 CrAccepted-AOC SHOP NO 106 1ST FLOOR ASHOKA SHOPPING CENTRE LT ROAD MUMBAI 400001 | MUMBAI | MUMBAI | MAHARASHTRA | 400001 | ₹1.0 Cr | L1 | Accepted-AOC AOC |
| 2 | L2₹1.1 Cr+₹4.8 L (4.59%)Rejected-Finance 1 14 SUJAL MANSION B BLOCK BHANGWADI KALBADEVI ROAD MUMBAI 400 002 | MUMBAI | MAHARASHTRA | 400002 | ₹1.1 Cr+₹4.8 L (4.59%) | L2 | Rejected-Finance Other Than Being Lowest |
| 3 | L3₹1.1 Cr+₹8.9 L (8.50%)Rejected-Finance | ₹1.1 Cr+₹8.9 L (8.50%) | L3 | Rejected-Finance Other Than Being Lowest |
| 4 | L4₹1.2 Cr+₹20.0 L (19.1%)Rejected-Finance BLOCK C 14 GROUND FLOOR PLOT 618 624 BHIVANDIWALA TERRACE JAGANNATH SHANKARSHETH MARG DHOBI TALAO NEAR KALBADEVI POST OFFICE MUMBAI 400002 | MUMBAI | MAHARASHTRA | 400002 | ₹1.2 Cr+₹20.0 L (19.1%) | L4 | Rejected-Finance Other Than Being Lowest |
| 5 | L5₹1.3 Cr+₹22.0 L (21.0%)Rejected-Finance SHOP NO 10 BMC SHOPPING CENTRE MITHA NAGAR GOREGAON WEST MUMBAI 400 104 | MUMBAI | MUMBAI SUBURBAN | MAHARASHTRA | 400104 | ₹1.3 Cr+₹22.0 L (21.0%) | L5 | Rejected-Finance Other Than Being Lowest |
| Sl No | Description | Qty | Unit | Shetty Construction Co L9 | ASHOK ENTERPRISES L6 | Chakshu Enterprise L2 | AGRAWAL ASSOCIATES L4 | Idustrial products India L7 | Nexus Infratech L3 | pk Enterprises L1 | sapana enterprises L8 | Shree Ayyappa Engineering L5 | shakti engineering and electrical works L10 |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 1.00 | Comprehensive maintenance of fire detection system / automatic fire alarm system / fire suppression system / fire hydrant system, including connected pump motors of any type, valves, starter panels, control panels, detectors and associated accessories, installed at various locations in INS ANGRE & buildings located inside Naval Dockyard area, including attending day-to-day complaints and carrying out cleaning, inspection, repair and testing of equipment to keep the entire system in functional condition, complete all as specified and directed by the Engineer-in-Charge.
Detailed scope of work shall include the following:
(i) Routine Maintenance:
Regular cleaning, inspection, checking and rectification/repair as required of all equipment and components of fire detection, fire alarm, fire suppression and fire hydrant systems to ensure continuous and reliable operation.
(ii) Operational Testing:
Operational testing of all fire detection and fire fighting equipment, including pumps and panels, in the presence of the User’s Representative and Engineer-in-Charge.
(iii) Test Reports:
Submission of detailed test reports certifying satisfactory functioning of all equipment, duly signed by the contractor, User’s Representative and Engineer-in-Charge.
(iv) Manpower & Attendance:
Maintenance shall be carried out by sufficient numbere of skilled/unskilled technician having minimum 3–5 years’ experience, deployed on daily basis in general shift from 0900 hrs to 1700 hrs except Sundays to JE E/M-in-Charge at MES Service Cell for attending day-to-day complaints.
Daily routine maintenance records shall be maintained in the format approved by the Engineer-in-Charge. All complaints shall be attended promptly and recorded in the complaint register. | 9 | Each Month | 35,750 ₹3,21,750 | 35,000 ₹3,15,000 | 26,950 ₹2,42,550 | 34,000 ₹3,06,000 | 37,777 ₹3,39,993 | 15,000 ₹1,35,000 | 10,000 ₹90,000 Lowest | 33,150 ₹2,98,350 | 32,500 ₹2,92,500 | 38,888 ₹3,49,992 |
| 2.00(v) Emergency Visits: Emergency visits shall be carried out whenever called, in addition to routine maintenance, in case of any system failure due to any cause, without any extra cost. (vi) Materials & Spares: Materials required for replacement shall be measured and paid separately under relevant items of this Schedule as SUPPLY ONLY. However, minor consumables/spares such as screws, nuts, washers, wires, couplings of motors, tools and plants etc. shall be deemed to be included in the quoted rate. Note: In case of failure/absence of the attendence of the manpower at MES Service Cell during the specified time, recovery shall be effected @ ₹1000/- per hour beyond 4 hours. | |||||||||||||
| 3.00 | Material and labour for locating faults and testing of all loops of Automatic Fire Detection System (AFDS), including smoke detectors, heat detectors, beam detectors, flame detectors, hooters, response indicators, manual call points etc. of existing make, comprising checking and testing of electrical wiring connections for each device, manual/mechanical cleaning of all connected devices, re-numbering of devices for programming in AFDS panels, configuration of connected devices as per actual site location, updating of software of AFDS panels of any make as per site requirement, including testing in the presence of User’s Representative and JE/Engineer-in-Charge, complete all as specified and directed.
Notes:
(i) Separate test report for each panel shall be submitted after completion of work. Cost of the same shall be deemed to be included in the quoted rate.
(ii) All devices connected to each AFDS panel, irrespective of loop capacity, including loop testing, wiring testing, cleaning of detectors (smoke/thermal/beam/flame), response indicators, manual call points, re-numbering, configuration, programming and software updation of AFDS panel, shall be treated as one job. | 30 | Each Job | 1,852 ₹55,560 | 1,752 ₹52,560 Lowest | 1,870 ₹56,100 | 2,580 ₹77,400 | 2,222 ₹66,660 | 2,270 ₹68,100 | 3,850 ₹1,15,500 | 3,315 ₹99,450 | 3,020 ₹90,600 | 2,580 ₹77,400 |
| 4.00 | Supply and fix, in replacement, photo-electric smoke cum thermal detector with mounting base, complete all as specified and directed. | 840 | Each | 2,812 ₹23,62,080 | 2,617 ₹21,98,280 | 2,090 ₹17,55,600 | 2,200 ₹18,48,000 | 2,444 ₹20,52,960 | 1,500 ₹12,60,000 | 1,150 ₹9,66,000 Lowest | 1,450 ₹12,18,000 | 2,493 ₹20,94,120 | 3,100 ₹26,04,000 |
| 5.00 | Supply and fix, in replacement, addressable manual call point, resettable type, complete all as specified and directed. | 175 | Each | 2,671 ₹4,67,425 | 2,500 ₹4,37,500 | 2,750 ₹4,81,250 | 2,800 ₹4,90,000 | 2,666 ₹4,66,550 | 1,890 ₹3,30,750 Lowest | 2,150 ₹3,76,250 | 3,045 ₹5,32,875 | 2,755 ₹4,82,125 | 2,678 ₹4,68,650 |
| 6.00 | Supply and fix, in replacement, conventional manual call point, resettable type, complete all as specified and directed.
Make: Honeywell / Bosch / Notifier | 85 | Each | 1,623 ₹1,37,955 | 1,000 ₹85,000 | 990 ₹84,150 | 1,100 ₹93,500 | 1,666 ₹1,41,610 | 600 ₹51,000 | 550 ₹46,750 Lowest | 630 ₹53,550 | 1,250 ₹1,06,250 | 1,789 ₹1,52,065 |
| 7.00 | Supply and fix, in replacement, intelligent addressable monitor module, complete all as specified and directed. | 60 | Each | 2,623 ₹1,57,380 | 2,200 ₹1,32,000 | 2,420 ₹1,45,200 | 2,500 ₹1,50,000 | 2,666 ₹1,59,960 | 1,850 ₹1,11,000 | 1,850 ₹1,11,000 | 1,815 ₹1,08,900 Lowest | 2,455 ₹1,47,300 | 2,789 ₹1,67,340 |
| 8.00 | Supply and fix, in replacement, fault isolator module with automatic resetting arrangement, complete all as specified and directed. | 75 | Each | 1,785 ₹1,33,875 | 1,700 ₹1,27,500 Lowest | 1,705 ₹1,27,875 | 1,700 ₹1,27,500 Lowest | 1,777 ₹1,33,275 | 1,860 ₹1,39,500 | 1,900 ₹1,42,500 | 1,815 ₹1,36,125 | 1,822 ₹1,36,650 | 1,789 ₹1,34,175 |
| 9.00 | Supply and fix, in replacement, response indicator (RI), complete all as specified and directed. | 100 | Each | 1,623 ₹1,62,300 | 1,000 ₹1,00,000 | 1,155 ₹1,15,500 | 250 ₹25,000 | 1,111 ₹1,11,100 | 180 ₹18,000 | 45 ₹4,500 Lowest | 185 ₹18,500 | 1,122 ₹1,12,200 | 1,234 ₹1,23,400 |
| 10.00 | Supply and fix, in repairs, control module (HZM) suitable for flame detectors, complete all as specified and directed. | 50 | Each | 3,123 ₹1,56,150 | 2,500 ₹1,25,000 | 2,750 ₹1,37,500 | 2,900 ₹1,45,000 | 3,333 ₹1,66,650 | 1,200 ₹60,000 Lowest | 2,226 ₹1,11,300 | 2,010 ₹1,00,500 | 2,844 ₹1,42,200 | 3,456 ₹1,72,800 |
Tender Value
₹1.2 Cr
EMD Value
₹1.9 L
Closing Date
5 Feb 2026, 6:00 pmClosed
CWE (NW) Mumbai
CWE NW MUMBAI
AS PER TENDER
2026_MES_748029_1
8512/CWE(NW)Mumbai/E8
Open Tender
Civil Works - Others
Item Rate
270 days
GE (NW) Kunjali
AS PER TENDER
7 documents required · 7 mandatory
₹1,000
GE NW KUNJALI
₹1.9 L
Yes
27 Mar 2026
10 Jan 2026
7 Feb 2026
10 Jan 2026
5 Feb 2026
31 Jan 2026
10 Jan 2026 - 30 Jan 2026
Comprehensive maintenance of fire detection system / automatic fire alarm system / fire suppression system / fire hydrant system, including connected pump motors of any type, valves, starter panels, control panels, detectors and associated accessories, installed at various locations in INS ANGRE & buildings located inside Naval Dockyard area, including attending day-to-day complaints and carrying out cleaning, inspection, repair and testing of equipment to keep the entire system in functional condition, complete all as specified and directed by the Engineer-in-Charge. Detailed scope of work shall include the following: (i) Routine Maintenance: Regular cleaning, inspection, checking and rectification/repair as required of all equipment and components of fire detection, fire alarm, fire suppression and fire hydrant systems to ensure continuous and reliable operation. (ii) Operational Testing: Operational testing of all fire detection and fire fighting equipment, including pumps and panels, in the presence of the User’s Representative and Engineer-in-Charge. (iii) Test Reports: Submission of detailed test reports certifying satisfactory functioning of all equipment, duly signed by the contractor, User’s Representative and Engineer-in-Charge. (iv) Manpower & Attendance: Maintenance shall be carried out by sufficient numbere of skilled/unskilled technician having minimum 3–5 years’ experience, deployed on daily basis in general shift from 0900 hrs to 1700 hrs except Sundays to JE E/M-in-Charge at MES Service Cell for attending day-to-day complaints. Daily routine maintenance records shall be maintained in the format approved by the Engineer-in-Charge. All complaints shall be attended promptly and recorded in the complaint register.
(v) Emergency Visits: Emergency visits shall be carried out whenever called, in addition to routine maintenance, in case of any system failure due to any cause, without any extra cost. (vi) Materials & Spares: Materials required for replacement shall be measured and paid separately under relevant items of this Schedule as SUPPLY ONLY. However, minor consumables/spares such as screws, nuts, washers, wires, couplings of motors, tools and plants etc. shall be deemed to be included in the quoted rate. Note: In case of failure/absence of the attendence of the manpower at MES Service Cell during the specified time, recovery shall be effected @ ₹1000/- per hour beyond 4 hours.
Material and labour for locating faults and testing of all loops of Automatic Fire Detection System (AFDS), including smoke detectors, heat detectors, beam detectors, flame detectors, hooters, response indicators, manual call points etc. of existing make, comprising checking and testing of electrical wiring connections for each device, manual/mechanical cleaning of all connected devices, re-numbering of devices for programming in AFDS panels, configuration of connected devices as per actual site location, updating of software of AFDS panels of any make as per site requirement, including testing in the presence of User’s Representative and JE/Engineer-in-Charge, complete all as specified and directed. Notes: (i) Separate test report for each panel shall be submitted after completion of work. Cost of the same shall be deemed to be included in the quoted rate. (ii) All devices connected to each AFDS panel, irrespective of loop capacity, including loop testing, wiring testing, cleaning of detectors (smoke/thermal/beam/flame), response indicators, manual call points, re-numbering, configuration, programming and software updation of AFDS panel, shall be treated as one job.
Supply and fix, in replacement, photo-electric smoke cum thermal detector with mounting base, complete all as specified and directed.
Supply and fix, in replacement, addressable manual call point, resettable type, complete all as specified and directed.
Supply and fix, in replacement, conventional manual call point, resettable type, complete all as specified and directed. Make: Honeywell / Bosch / Notifier
Supply and fix, in replacement, intelligent addressable monitor module, complete all as specified and directed.
Supply and fix, in replacement, fault isolator module with automatic resetting arrangement, complete all as specified and directed.
Supply and fix, in replacement, response indicator (RI), complete all as specified and directed.
Supply and fix, in repairs, control module (HZM) suitable for flame detectors, complete all as specified and directed.
Supply and fix in repairs of hooter with control module.
Supply only addressable / conventional type heat detector with mounting base, complete all as specified and directed.
Supply only addressable / conventional type beam detector (beam master type) complete with transmitter and receiver, including all standard accessories, complete all as specified and directed.
Supply only flame detector, complete with all standard fittings and accessories, complete all as specified and directed.
Supply only addressable fire alarm control panel, complying with BS EN 54 / UL standards, single loop panel, capable of supporting minimum 126 detectors and 126 modules per loop, complete all as specified and directed.
Supply only addressable fire alarm control panel, complying with BS EN 54 / UL standards, double loop panel, capable of supporting minimum 126 detectors and 126 modules per loop, complete all as specified and directed.
Supply and fix addressable fire alarm control panel, complying with BS EN 54 / UL standards, double loop panel, capable of supporting minimum 126 detectors and 126 modules per loop, including installation, interconnections, testing and commissioning, complete all as specified and directed.
Supply only addressable fire alarm control panel, complying with BS EN 54 / UL standards, four loop panel, capable of supporting minimum 126 detectors and 126 modules per loop, complete all as specified and directed.
Supply and fix addressable fire alarm control panel, complying with BS EN 54 / UL standards, four loop panel, capable of supporting minimum 126 detectors and 126 modules per loop, including installation, interconnections, testing and commissioning, complete all as specified and directed.
Supply only addressable fire alarm repeater panel, complete with all standard accessories, complete all as specified and directed.
Material and labour for taking out unserviceable repeater / fault control panel of existing fire detection system from site, repairing the same including replacement of defective/unserviceable components, refixing in original position, and carrying out testing and commissioning to ensure proper functioning, complete all as specified and directed by the Engineer-in-Charge.
Supply and fix, in replacement, PCB loop card suitable for self-addressable fire finder system, including necessary connections, testing and commissioning, complete all as specified and directed.
Supply, laying and connecting, in replacement, PVC insulated and PVC sheathed copper conductor cable, FRLS, 1100 Volts grade, 2 core × 1.5 sq mm, drawn in existing MS/PVC conduit fixed on walls/ceilings of the building, including necessary connections, testing and commissioning, complete all as specified and directed.
Supply and fix MS conduit of 20 mm diameter, including all necessary accessories such as saddles, couplers, bends, tees, inspection bends, lock nuts and screws, fixed on wall/ceiling, complete all as specified and directed.
Supply only 12 Volt, 7 Ah sealed maintenance-free battery, complete all as specified and directed.
Disconnecting, dismantling and taking out unserviceable motherboard of existing fire finder (addressable fire alarm) system and supply and fix new compatible motherboard suitable for two numbers of loop cards, including refixing, necessary interconnections, testing and commissioning, complete all as specified and directed.
Material and labour for refilling Sinorix 1230 (Siemens) or FK-5-1-12 (Rotarex) or FM-200 gas in cylinders of any capacity, as per site requirement, including disconnecting and safely removing cylinders from site, transporting to authorized factory/workshop for refilling, bringing back and reinstalling the same, including replacement of unserviceable pressure gauges, connector pipes, nozzles and other connected accessories, and testing in the presence of JE/Engineer-in-Charge, complete all as specified and directed. Note: Cost of transportation of gas cylinders to and from the factory/workshop shall be deemed to be included in the quoted rate..
Material and labour for hydrostatic pressure testing (HPT) of gas cylinders of existing capacity at authorized factory/workshop, including successful testing, punching of test year, painting of cylinders, and submission of test certificates, complete all as specified and directed.
Supply only, in replacement, new gas cylinder of 68 litre capacity, test year 2024, suitable for refilling of Sinorix 1230 (Siemens) or FK-5-1-12 (Rotarex) or FM-200 gas or NOVOC 1230 (3M) , conforming to OEM and statutory requirements, complete all as specified and directed.
Material and labour for servicing of connected valves and solenoids of existing fire suppression system, of any size and make, including cleaning, checking, lubrication, minor adjustments and functional testing, complete all as specified and directed.
Material and labour for replacement of valve and solenoid assembly, complete with all accessories, suitable for Sinorix 1230 (Siemens) or FK-5-1-12 (Rotarex) or FM-200 or NOVOC 1230 (3M) gas cylinders, as per OEM recommendations, including testing and commissioning, complete all as specified and directed.
Material and labour for supply, installation, testing and commissioning of real-time cylinder weight monitoring (weight-loss) device, suitable for Sinorix 1230 (Siemens) or FK-5-1-12 (Rotarex) or FM-200 or NOVOC 1230 (3M) gas cylinders, including interfacing with existing fire suppression system, complete as per OEM recommendations and all as specified and directed by the Engineer-in-Charge.
Supply and fix, in replacement, discharge nozzle or sensor of fire suppression system, of existing type and rating, at various buildings as per site requirement, including necessary connections, alignment and testing, complete all as specified and directed.
Supply and fix, in replacement, MS/GI pipes of existing diameters for fire suppression system at various buildings, including fittings, joints, supports, cutting, threading/welding, testing and making good, complete all as specified and directed.
Supply only conventional gas release fire alarm control panel, complying with BS EN 54 / UL standards, single loop panel, capable of supporting minimum 126 detectors and 126 modules, complete all as specified and directed.
Supply only conventional fire alarm control panel, complying with BS EN 54 / UL standards, single loop panel, capable of supporting minimum 126 detectors and 126 modules, complete all as specified and directed.
Disconnecting horizontal or vertical split-casing pump of any make/model, dismantling and taking out pump shaft assembly for replacement of DE or NDE bearings, including replacement of pump gaskets, gland packing, nuts, bolts and flanges of required size, servicing of pump set, re-coupling, alignment, testing and commissioning, complete all as specified and directed, for the following sizes/capacities of pumps. Note :- Rates deemed to be included for decoupling and coupling pump with motor.
Bearing suitable for pump coupled with 60 HP motor.
Bearing suitable for pump coupled with 10 HP motor.
Supply and fix, in repair, DE/NDE bearings of electric motor, including dismantling, removal of defective bearings, supply and fixing of new bearings, necessary greasing, reassembly of motor, reconnection, testing and commissioning, complete all as specified and directed, for the following motor capacities:
Motor capacity 60/75 HP suitable bearing
Motor capacity 10/12.5 HP suitable bearing
Material and labour for repair and replacement of rubber coupling, of size as per existing, including dismantling, supply and fixing of new rubber coupling, alignment, testing and commissioning, complete all as specified and directed.
Supply and fix, in repair, pressure gauge, 150 mm or 100 mm dial, range 0–10 kg/cm², including removal of defective gauge, fixing new gauge, testing and commissioning, complete all as specified and directed.
Supply and fix, in repair, MS coupling suitable for pumps driven by 75 HP to 100 HP motors, including dismantling, refixing, alignment, testing and commissioning, complete all as specified and directed.
Supply and fix, in repair, MS coupling suitable for pumps driven by 45 HP to 60 HP motors, including dismantling, refixing, alignment, testing and commissioning, complete all as specified and directed.
Supply and fix, in repair, MS coupling suitable for pumps driven by 5 HP to 40 HP motors, including dismantling, refixing, alignment, testing and commissioning, complete all as specified and directed.
Disconnecting electric connections from various capacities of electric motor and dismantling from the pumping sets , removing and taking down carefully and transporting to authorised workshop for rewinding strip opening and dismantling complete rotor and stator assemby , cutting ;and taking out old burnt copper winding from the stator assembly and cleaning the slots of stor with carbon tetra chloride solution .Material and labour for rewinding complete stator assembly with and including super enamelled copper winding wire of suitable gauge machine with existing .Applying the minimum two coats of insulation varnish and keeping the stator assembly in heating chamber to improve for insulation value. Assemblyling the motor , transporting to site of work, coupled with the pumping sets allingments properly , connecting the LT cables and testing and commissioning complete of the following capacity of Electric Motors :
75 HP/60HP Capacity
30 HP to 45 HP Capacity
20 HP to 25 HP Capacity
7.5 HP to 10 HP Capacity
S&F in repair/replacement of main contactor suitable for following capacity of motors including taking down old one :-
100 HP motor, MNX 140, 3 pole, 415V, 50 Hz Make :L&T/Havells/Siemens
75/60 HP motor, MNX 95 , 3 pole, 415V, 50 Hz Make :L&T/Havells/Siemens
12.5/10/7.5 HP motor, MNX 18, 3 pole, 415V, 50 Hz Make :L&T/Havells/Siemens
S&F in repair/replacement of MCCBs , Adjustable type fixed in existing panel board including taking down old one :-
MCCB 3 Phase (TP) 400 A, 35 KA
MCCB 3 Phase (TP) 200A 50Hz, 35 KA
MCCB 3 Phase (TP) 100A 50Hz, 25 KA
MCCB 3 Phase (TP) 63A 50Hz, 16 KA
M & L for replacement of unserviceable pump & line shaft for following cap pump sets :-
Suitable for 100 HP
Suitable for 75 HP/60/50HP
Suitable for 25 HP
Suitable for 7.5/10/12.5HP
M & L for replacement of unserviceable impeller incl impeller ring and casing ring and balancing of rotating assembly with impeller as per existing suitable for following cap pump sets :-
Suitable for 100 HP
Suitable for 75 HP/60/50HP
Suitable for 25 HP
Suitable for 7.5/10/12.5HP
M & L for replacement of unserviceable air release valve made out of Stainless steel of any size for 75hp pump set. Note :- Rates for replacement of gaskets, SS nuts, SS bolts, washers, etc are deemed to be included in the item rate.
Supply anf fix in repair direct on line (DOL) starter 3 phase 415 Volts 7.5 hp to 05 HP capacity
Material and labour for disconnecting, transporting to civil workshop for repairing, metal filling, turning and grinding on lathe machine shafts of the following capacity pump sets and re-installing after repair complete all as specified and directed.
Suitable for 100 HP
Suitable for 75 HP/60/50HP
Suitable for 25 HP
Suitable for 7.5/10/12.5HP
Material and labour for replacement of gland packing, suitable for pump sets and sluice valves of any capacity, including removal of worn-out gland packing, cleaning of stuffing box and shaft/sleeve, refixing, adjustment, testing for leakage and satisfactory operation, complete all as specified and directed by the Engineer-in-Charge.
Supply and fix, in repair/replacement, star-delta starter suitable for 60 / 75 HP electric motor, 415 Volts, 50 Hz, including dismantling of unserviceable starter/parts, supply and fixing of new starter or components, reconnection, testing and commissioning, complete all as specified and directed.
Supply and fix, in repair/replacement, star-delta starter suitable for 12.5 / 10 / 7.5 HP electric motor, 415 Volts, 50 Hz, including dismantling of unserviceable starter/parts, supply and fixing of new starter or components, reconnection, testing and commissioning, complete all as specified and directed.
Taking down and dismantling centrifugal pump sets of following capacity installed at various water supply installations for servicing/overhauling , greasing, replacing bearing and replacement of worn out parts which shall be measured and paid separately under the relevant items of Sch `A' :- Note : Cost of minor spare parts such as gland packing, bearings, rubber packing, coupling, nut bolts, washers etc is included in quoted rate by the contractor
S&F in repair sluice valves flanged end, cast iron body, flanged and drilled and non rising type brass spindle with nut, long body, class P N 16, conforing to IS 14846 of 2000 for following sizes including all flange joint with rubber or fiber board, bolts, nuts and washers complete including pumping out accumulated water all as specified and directed of following size.
150 mm bore
100 mm bore
80 mm bore
S&F in repair Non Return sluice Valve flanged end, cast iron body, flanged and drilled and non rising type brass spindle with nut, long body, class P N 16, conforing to IS 14846 of 2000 for following sizes including all flange joint with rubber or fiber board, bolts, nuts and washers complete including pumping out accumulated water all as specified and directed of make sant, kirloskar, kartar and of following size.
150 mm bore
100 mm bore
Construction of brick masonry valve chamber in repair, of internal size 1.20 m × 1.20 m × 1.20 m, with chamber top 0.30 m above ground level, suitable for installation of sluice valves, comprising the following works: (a) Earthwork in excavation in any type of soil, including dressing, ramming, watering and disposal of surplus excavated material outside MD land. (b) Hardcore of broken stone, 15 cm thick, well rammed and consolidated. (c) Plain cement concrete (PCC) 1:4:8 (Type D-2), 15 cm thick, as foundation bed. (d) Brick masonry 23 cm thick, built with first-class bricks in cement mortar 1:4. (e)Internal and external plastering, 15 mm thick, in cement mortar 1:3, including plastering to floor/top surfaces, finished even and smooth without using extra cement. (f)RCC coping in PCC 1:2:4 (Type B-1), including embedding 50 mm × 50 mm × 6 mm MS angle frame. (e)MS cover plate, 5 mm thick, mounted on angle frame, with rectangular hinged opening of size 150 mm × 100 mm, including locking arrangement, holdfasts, etc. (f)Painting to all steel surfaces with one coat of red oxide primer and two coats of synthetic enamel paint. complete all as specified and directed by the Engineer-in-Charge.
Supply, laying, fixing, jointing, connecting and testing of MS ERW pipes, ISI marked conforming to IS:1239, of any length, including supply and fixing of all fittings such as bends, tees, reducers, sockets, flanges, unions, clamps and supports, fixed on walls/ceilings or laid in floors/trenches, including dismantling and taking down existing unserviceable pipes where required, complete all as specified and directed by the Engineer-in-Charge.
150 mm bore
100 mm bore
80 mm bore
Taking down old unserviceable GI/MS pipelines and supply and fix MS heavy class pipes, complete with all fittings such as unions, tees, bends, elbows, reducers, sockets etc., fixed on walls/ceilings or laid in floors/trenches, complete all as specified and directed. Note: Cost of supporting clamps, hangers, nuts, bolts and other fixing accessories required for installation shall be deemed to be included in the quoted rate.
(a) MS Pipe size 80 mm dia
(b) MS Pipe size 100 mm dia
Supply and fix, in repairs, gunmetal gate valve, ISI marked conforming to IS:778, with iron wheel head, screwed ends suitable for iron/MS pipes or ferrule connection, including necessary fittings such as unions, check nuts, packing, and any additions/alterations required for fixing, complete all as specified and directed by the Engineer-in-Charge.
40 mm bore
50 mm bore
Taking down corroded MS structural sections and supply and fix angle iron framework of any size, including necessary cutting, welding, drilling, fabrication, erection and fixing, complete with one coat of red oxide primer and two coats of synthetic enamel paint, complete all as specified and directed by the Engineer-in-Charge.
Material and labour for preparation of steel/iron surfaces of existing painted pipelines, of any size up to 200 mm diameter, including scraping, wire brushing, cleaning of rust and loose paint, and applying one coat of red oxide zinc chromate primer followed by two coats of approved anti-corrosive paint, suitable for protection against sea water, matching existing colour pattern, including writing identification name and flow direction arrow marking with synthetic enamel paint, complete all as specified and directed by the Engineer-in-Charge.
Supply and fix, in repair, rubber hose pipe, 30 m long, 20 mm diameter, plain, 2-ply rayon braided high-pressure type, ISI marked, complete all as specified and directed.
Supply and fix, in repair, canvas fire hose, 63 mm bore, 30 m long, conforming to relevant IS standards, provided with male and female brass couplings at both ends, ISI marked, complete all as specified and directed.
Supply and fix, in repair, stainless steel nozzle, 25 mm bore, suitable for 63 mm diameter canvas fire hose, complete all as specified and directed.
Supply and fix, in repair, hose reel drum, suitable for 30 m long × 20 mm diameter rubber hose, including necessary brackets and fittings, complete all as specified and directed. Make: Vijay Engineering / Omex / Cease Fire
Supply and fix, in repair, gunmetal branch pipe, 63 mm instantaneous inlet, threaded outlet with 15 mm bore nozzle, complete all as specified and directed.
Supply & fix in repair twin outlet Brass hydrant valve 100mm having 65mm outlet with lock pin wheel complete all as specified and directed by Engineer-in-charge.
Supply and fix, in repair, single outlet brass hydrant valve, 100 mm size, having one 65 mm outlet, complete with lock-pin wheel, complete all as specified and directed by the Engineer-in-Charge.
Supply and fix, in repair, gunmetal two-way fire brigade inlet connection, complete with adaptor of size 80 mm dia × 63 mm dia, including necessary fittings, complete all as specified and directed.
Excavation in trenches not exceeding 1.5 mtr wide and not exceeding 1.5 mtr in depth for foundation/laying of pipe etc and getting out in hard dense soil/road/PCC surface complete all as specified.
Returning filling in including spreading, leveling, watering and well ramming in layers not exceeding 25 cm deep as in soil complete all as specified .
Removing surplus excavated soil to a distance not exceeding 50 m and deposited where directed complete all as specified.
Supply and fix, in replacement, wall-mounted fire hose box, made of 16-gauge MS sheet, powder-coated in Post Office Red colour, cabinet size 800 mm × 600 mm × 250 mm, suitable for housing two numbers of 15 m long canvas hoses and branch pipes, complete with glass front, locking arrangement, painted fire red externally and brilliant white internally, complete all as specified and directed by the Engineer-in-Charge.
Supply and fix, in replacement, damaged glass panes, 6 mm thick, suitable for existing indoor type fire cabinets, complete all as specified and directed by the Engineer-in-Charge.
Supply and fix, in replacement, mouth washers, suitable for 63 mm size fire hydrant, complete all as specified and directed by the Engineer-in-Charge.
M & L for heavy duty ball type MS foot valves flanged end swing type operation with rubber seat as per IS4038 of following types, including nuts, bolts and washers etc complete.
(a) 80 mm bore
(b) 100 mm bore
(c) 150 mm Bore
Supply, laying, fixing, jointing, connecting and testing of XLPE insulated, aluminium conductor, armoured power cable, 1100 Volts grade, 4 core × 16 sq mm, laid in trenches or drawn through pipes, fixed on walls/floors with suitable size clamps/supports or laid in any other required position, including dismantling and taking out damaged/unserviceable existing cable, complete all as specified and directed by the Engineer-in-Charge. Note: Cost of cable lugs/thimbles, cable glands, cladding material, saddles/clamps and all accessories required for proper termination and fixing shall be deemed to be included in the quoted rate and no extra payment shall be made.
All as per Item No. 76.00 above, but for XLPE aluminium armoured cable 3.5 core × 25 sq mm, 1100 Volts grade, complete all as specified and directed.
All as per Item No. 76.00 above, but for XLPE aluminium armoured cable 3.5 core × 35 sq mm, 1100 Volts grade, complete all as specified and directed.
All as per Item No. 76.00 above, but for XLPE aluminium armoured cable 3.5 core × 50 sq mm, 1100 Volts grade, complete all as specified and directed.
All as per Item No. 76.00 above, but for XLPE aluminium armoured cable 3.5 core × 95 sq mm, 1100 Volts grade, complete all as specified and directed.
Material and labour for periodic and preventive servicing of diesel engine driven fire pump, installed at various locations, complete, including the following operations: (a) Replacement of engine oil filter (b) Replacement of air filter (c) Replacement of fuel filter (d) Calibration, servicing and cleaning of fuel injector pump (e) Replacement of drive belt (f) Replacement of engine oil and coolant (g) Repair/servicing of radiator assembly (h) Replacement of four (04) numbers of anti-vibration pads for each diesel engine pump Notes: (i) Any parts/accessories required to make the engine pump serviceable and fully functional, as directed by the Engineer-in-Charge, shall be deemed to be included in the quoted rate. (ii) Cost of dismantling, lifting, repositioning and refixing diesel engine driven pump of any make and capacity for fixing anti-vibration pads, including minor spares, tools & plants and reconnection as per existing arrangement, shall be deemed to be included in the quoted rate. Complete all as specified and directed.
Attending complaints of fire detection / fire alarm systems / fire suppression system / fire hydrant system, including connected pump motors of any type, valves, starter panels etc., installed at various locations, comprising cleaning, inspection, repair and testing of equipment to keep the systems in functional condition, complete all as specified and directed. (i) Operational testing of all fire detection and fire-fighting equipment in the presence of User’s Representative and Engineer-in-Charge. (ii) Maintenance shall be carried out by one skilled technician having minimum 3–5 years’ experience and one helper. (iii) Materials required for replacement shall be measured and paid separately under relevant items of this schedule. However, minor consumables such as screws, nuts, wires, washers, motor couplings, tools & plants etc. shall be deemed to be included in the quoted rate. Note: Complaints shall be attended and rectified within 24 hours of intimation. In case of failure beyond 24 hours, recovery shall be effected @ ₹500/- per hour beyond the stipulated time.
Supply and fix, in repair, 1 HP monoblock pump, 3-phase, 440 Volts, including dismantling, refixing, testing and commissioning, complete all as specified and directed.
Supply and fix, in repair, 5 HP submersible open-well pump, 3-phase, 440 Volts, including dismantling, refixing, testing and commissioning, complete all as specified and directed.
Supply , fixing, testing in repairs of JEF ECO SAFE Maintenance Free Grounding Solution set comprising of High tensile low carbon steel rod of 3 Mts length & 25 mm dia with 250 micron ( averaSchneider ) molecularly bonded copper on the outer surface to confirm with requirements of UL467 along with Back-fill compound strictly be a Carbon based conductive concrete type which has a resistivity of less than 0.12 Ohm Mtr as per Clause 14.5D of IEEE : 80 standard. Back-fill compound should be electronically conductive ( Like in metals ) and should not depend on moisture for conduction. JEF Powerfill Loresco compound shall be supplied in 50 Pound Bag. ( 1 Bag of 50 Pounds required per earthing set). Back-fill comound should be environment friendly, should solidify when mixed with water and set like concrete and should not leach / diffuse into the ground. A suitable earth terminaton clamp should also be supplied along with the set alongwith earth pit weatherproof incl all as specified . Note : Back-fill compund shall not be mixed with any soil while pouring in the bore hole.
M & L for Earth continuity conductor / main earthing lead, fixed on wall, batten, recess, chases, buried in ground, drawn in conduit/pipe or fixed to poles, as required for loop earthing, using 25 mm × 3 mm galvanised iron strip, complete all as specified and directed.
Material and labour for replacement of fabricated MS fuel tank, of existing size and thickness, suitable for storage of diesel for diesel engine operated fire pump, including appropriate MS stand, inlet opening for filling diesel, outlet connection to engine, and fuel level indicator, complete all as specified and directed by the Engineer-in-Charge.
Supply and fix, in replacement, UPS of 1.0 kVA capacity, suitable for operation on 230 Volts, 50 Hz AC supply, including connections, testing and commissioning, complete all as specified and directed. Make: Microtek / Sukam
Supply and fix sprinkler (glass bulb type), standard response, pendent type, 68°C temperature rating, conforming to IS:15106 / TAC guidelines, complete all as specified and directed.
Supply and fix stainless steel flexible sprinkler drop hose, rated 200 psi, length up to 1800 mm, complete with end connections suitable for existing sprinkler size, including fixing and testing, complete all as specified and directed.
stage.html
html • 0.07 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.41 MB
8512.rar
Tender Documents • 3.38 MB
BOQ_837695.xls
BOQ • 2.60 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .