| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹23.3 LAccepted-AOC | L-1 | Accepted-AOC Being L1 | |
| 2 | L-2₹26.2 L+₹2.3 L (9.55%)Rejected-Finance | L-2 | Rejected-Finance Other Than First Lowest | |
| 3 | L-3₹27.9 L+₹4.0 L (16.5%)Rejected-Finance | L-3 | Rejected-Finance Other Than First Lowest | |
| 4 | L-4₹30.4 L+₹6.5 L (27.2%)Rejected-Finance 499 A VIDHYUT NAGAR A AJMER ROAD JAIPUR 302021 | JAIPUR | JAIPUR | RAJASTHAN | 302021 | L-4 | Rejected-Finance Other Than First Lowest | |
| 5 | L-5₹30.5 L+₹6.6 L (27.7%)Rejected-Finance | L-5 | Rejected-Finance Other Than First Lowest |
Tender Value
Refer Docs
EMD Value
₹62,000
Closing Date
27 Apr 2024, 6:00 pmClosed
GE Jaipur
GE Jaipur
REPAIR / MAINT OF PUMP SETS, SUBMERSIBLE PUMP SETS, STARTER AND CONNECTED ITEMS IN ZONE - II AREA UNDER AGE E/M OF GE JAIPUR
2024_MES_648548_1
GE/J-74/2023-24
Open Tender
Civil Works
Item Rate
270 days
GE Jaipur
As per Tender Documents
5 documents required · 5 mandatory
₹500
GE Jaipur
₹62,000
Yes
31 Aug 2024
30 Mar 2024
29 Apr 2024
30 Mar 2024
27 Apr 2024
13 Apr 2024
Amount
M & L for transporataion & dismantaling of mono block, fountain pump set any type, cap 5 HP, 1 or 3 phase, 415 volts, 50Hz, AC supply after disconnecting electric connection, dismanteling of pump for repairing/ replacing defective parts as ordered, re-assembling and testing including replacing worn out nuts, bolts, washers,Lathe machine work complete and lowering the same and reconnecting to pipe line and electric connection after following repairs as directed by Engineer-in-charge :- Note : - (i) The spare part required for replacement shall be measured & paid for separately as supply only under item
Supply only bush with oiling and greasing as required.
Supply only ball bearing as per existing. Make:- NBC/SKF/TATA
Supply only pumpshaft as per existing
Supply only gun metal impeller
Cutting of burnt winding and rewinding the stator with supper enamelled copper wire of suitable size and class of insulation including insulation paper, sleeves, thimbles etc.
M & L for transporataion & dismantaling of centrifugal pump set/ Mono block of cap 7.5 to 10 HP, 3 phase, 415 volts, 50Hz, AC supply after disconnecting electric connection, dismanteling of pump for repairing/ replacing defective parts as ordered, re-assembling and testing including replacing worn out nuts, bolts, washers, Lathe machine work complete and lowering the same and reconnecting to pipe line and electric connection after following repairs as directed by Engineer-in-charge :- Note : - (i) The spare part required for replacement shall be measured & paid for separately as supply only under relevant items of BOQ.
Supply only bush with oiling and gresing as required.
Supply only terminal box including connectors of copper, plate of motor.
Supply only ball bearing as per existing. Make:- NBC/SKF/TATA
Supply only gun metal impeller
Shaft sleeve bronze as per existing
Supply only shaft metallic coupling with key.
M & L for transporataion & dismantaling of centerifugal pump set / Mono block of Cap 12.5 HP 3 phase, 415 volts, 50Hz, AC supply after disconnecting electric connection, dismanteling of pump for repairing/ replacing defective parts as ordered, re-assembling and testing including replacing worn out nuts, bolts, washers, Lathe machine work complete and lowering the same and reconnecting to pipe line and electric connection after following repairs as directed by Engineer-in-charge :- Note : - (i) The spare part required for replacement shall be measured & paid for separately as supply only under item
Supply only bush with oiling and gresing as required.
Supply only terminal box including connectors of copper, plate of motor.
Supply only ball bearing as per existing. Make:- NBC/SKF/TATA
Supply only gun metal impeller
Supply only shaft sleeve bronze as per existing
M & L for transporataion & dismantaling of centerifugal pump set of Cap 20 HP 3 phase, 415 volts, 50Hz, AC supply after disconnecting electric connection, dismanteling of pump for repairing/ replacing defective parts as ordered, re-assembling and testing including replacing worn out nuts, bolts, washers , Lathe machine work complete and lowering the same and reconnecting to pipe line and electric connection after following repairs as directed by Engineer-in-charge :- Note : - (i) The spare part required for replacement shall be measured & paid for separately as supply only under item
Supply only bush with oiling and gresing as required.
Supply only ball bearing as per existing. Make:- NBC/SKF/TATA
Supply only terminal box including connectors of copper, plate of motor.
Supply only damaged star rubber coupling as per existing
Supply only gun metal impeller
Shaft sleeve bronze as per existing
supply only shaft metallic coupling with key.
M & L for transporattaion & dismanteling of centerifugal pump set of Cap 40 HP 3 phase, 415 volts, 50Hz, AC supply after disconnecting electric connection, dismanteling of pump for repairing/ replacing defective parts as ordered, re-assembling and testing including replacing worn out nuts, bolts, washers, Lathe machine work complete and lowering the same and reconnecting to pipe line and electric connection after following repairs as directed by Engineer-in-charge :- Note : - (i) The spare part required for replacement shall be measured & paid for separately as supply only under item
Supply only bush with oiling and gresing as required.
Supply only ball bearing as per existing. Make:- NBC/SKF/TATA
Supply only terminal box including connectors of copper, plate of motor.
Supply only damaged star rubber coupling as per existing
Supply only gun metal impeller
Supply only shaft sleeve bronze as per existing
Supply only shaft metallic coupling with key.
M & L for transporataion & dismantaling of centerifugal pump set of Cap 50 HP 3 phase, 415 volts, 50Hz, AC supply after disconnecting electric connection, dismanteling of pump for repairing/ replacing defective parts as ordered, re-assembling and testing including replacing worn out nuts, bolts, washers, Lathe machine work complete and lowering the same and reconnecting to pipe line and electric connection after following repairs as directed by Engineer-in-charge :- Note : - (i) The spare part required for replacement shall be measured & paid for separately as supply only under item
Supply only bush with oiling and gresing as required.
Supply only ball bearing as per existing. Make:- NBC/SKF/TATA
Supply only pumpshaft as per existing
Supply only terminal box including connectors of copper, plate of motor.
Supply only damaged star rubber coupling as per existing
Supply only gun metal impeller
Supply only shaft sleeve bronze as per existing
M&L for dismantaling of existing defective induction motor of the of Pumpset of 50 HP Capacity, 3 phase, 415 volt from the foundation, disconnecting the electric connection, coupling joint and taking out to workshop for cutting down and removing existing burnt copper windings, clenining of slots and rewinding the same with supper enameled copper conductor complete including varnishing, drying ovening, overhauling, greesing, necessary lathe work and replacement of bearing and fixing in the same position making neccessary electric connection and couppling connection and testing of induction motor complete all as specified and as directed by Eng in charge
,---ditto--- all as per Item No 7 above but Induction motor of pumpset of 40 HP capacity, 3 phase, 415 Volt complete
,---ditto--- all as per Item No 7 above but Induction motor of pumpset 20 HP capacity, 3 phase, 415 Volt complete
,---ditto--- all as per Item No 7 above but Induction motor of Pumpset 12.5 HP capacity, 3 phase, 415 Volt complete
,---ditto--- all as per Item No 7 above but Induction motor of pumpset 7.5 to 10 HP capacity, 3 phase, 415 Volt complete
M & L taking out including lifting of submersible pump set of Capacity 3 HP to 7.5 HP, 3 phase, 415 volts, 50Hz, AC supply along with column pipe of any size from the bore well after disconnecting electric connection, dismantling of pump and motor for repairing/ replacing defective parts as ordered, oiling, greasing as required and re-assembling and testing including replacing worn out nuts, bolts, washers complete and lowering the same after repairing and making electrical and delivery pipe connections complete all as specified and directed. Note : - (i) The spare part required for replacement shall be measured & paid for separately as supply only under item No
Supply only stainless steel pumpshaft.
Supply only gun metal impeller with neck key and distance bush.
Supply only Shaft bush.
Supply only thrust bearing with plate of pump
Supply only rubber gasket 3mm thick having 4 Nos of 5/8" dia hole.
Cutting of burnt winding and rewinding the stator with PVC insulated copper wire of suitable size and class of insulation including insulation paper, sleeves, thimbles etc.
M & L taking out including lifting of submersible pump set of capacity 10 HP to12.5 HP, 3 phase, 415 volts, 50Hz, AC supply along with column pipe of any size from the bore well after disconnecting electric connection, dismantling of pump and motor for repairing/ replacing defective parts as ordered, oiling, greasing as required and re-assembling and testing including replacing worn out nuts, bolts, washers complete and lowering the same after repairing and making electrical and delivery pipe connections complete all as specified and directed. Note : - (i) The spare part required for replacement shall be measured & paid for separately as supply only under item
Supply only stainless steel pumpshaft.
Supply only gun metal impeller with neck key and distance bush.
Supply only Shaft bush.
Supply only thrust bearing with plate of pump
Supply only rubber gasket 3mm thick having 4 Nos of 5/8" dia hole.
Cutting of burnt winding and rewinding the stator with PVC insulated copper wire of suitable size and class of insulation including insulation paper, sleeves, thimbles etc.
M & L taking out including lifting of submersible pump set of capacity 17.5 HP to 20 HP, 3 phase, 415 volts, 50Hz, AC supply along with column pipe of any size from the bore well after disconnecting electric connection, dismantling of pump and motor for repairing/ replacing defective parts as ordered, oiling, greasing as required and re-assembling and testing including replacing worn out nuts, bolts, washers complete and lowering the same after repairing and making electrical and delivery pipe connections complete all as specified and directed. Note : - (i) The spare part required for replacement shall be measured & paid for separately as supply only under item
Supply only stainless steel pumpshaft.
Supply only gun metal impeller with neck key and distance bush.
Supply only Shaft bush.
Supply only thrust bearing with plate of pump
Supply only rubber gasket 3mm thick having 4 Nos of 5/8" dia hole.
Cutting of burnt winding and rewinding the stator with PVC insulated copper wire of suitable size and class of insulation including insulation paper, sleeves, thimbles etc.
Supply and fix in repair DOL starter, 10 HP (MU1) suitable for 3 phase, 415 volts AC supply 10 HP motor complete all as specified and directed. Make- L&T Cat part No SS-95647 or equivelent as approved by GE.
Supply and fix in repair of fully automatic star delta starter MUG 20 suitable 20 HP Capacity complete all as specified and directed. Make- L&T Cat part No SS-95975 or equivelent as approved by GE.
Supply and fix in repair of fully automatic star delta starter MN32 FASD with MNX cont 415 volt,20-33Amp complete all as specified and directed. Make- L&T Cat part No SS-94366 or equivelent as approved by GE.
Supply and fix in repair of fully automatic star delta starter 40 to 50 HP (MN45) suitable for operating up to 40 HP to 50 HP centrifugal pump set complete all as specified and directed. Make- L&T Cat part No SS-94021 or equivelent as approved by GE.
Supply and fixing in replacement of fully automatic star delta starter (EMX3 soft starter) of capacity up to 20 HP centrifugal pump. Make:- L&T Cat No. EMX3-0043B-411 or equivalent as approved by GE.
Supply and fixing in replacement of fully automatic star delta starter (EMX3 soft starter) of capacity up to 40 HP centrifugal pump. Make:- L&T Cat No. EMX3-0053B-411 or equivalent as approved by GE.
Supply and fixing in replacement of fully automatic star delta starter (EMX3 soft starter) of capacity up to 50 HP centrifugal pump. Make:- L&T Cat No. EMX3-0076B-411 or equivalent as approved by GE.
Supply and fix in replacement copper cable multistranded conductor unarmoured 25 Sqmm single core 1100 v grade PVC insulated sheathed along with proper lugs complete all as specified and directed.
Supply and fix in repair MCCB TPN (4 pole) 63 Amp, 415 volts, 50 Hz 35KA complete all as specified and directed.
Supply and fix in repair MCCB TPN (4 pole) 100 Amp, 415 volts, 50 Hz 35KA complete all as specified and directed.
Supply and fix in repair MCCB TPN (4 pole) 200 Amp, 415 volts, 50 Hz 35KA complete all as specified and directed.
Supply and fix in repair MCCB TPN (4 pole) 250 Amp, 415 volts, 50 Hz 35KA complete all as specified and directed.
Supply and fix in repair MCCB TPN (4 pole) 400 Amp, 415 volts, 50 Hz 35KA complete all as specified and directed.
Supply & fix cable jointing kit for 1.1 KV grade cable for straight through heat shrinkable joint complete with jointing material and accessories including necessary earth work suitable for 3.5 core XLPE / PVC armoured AI conductor cable of 16 Sqmm to 50 Sqmm size complete all as specified and directed.
,---ditto--- all as per srl item No 28 above but 70Sqmm to 120 Sqmm size complete.
Supply & fix in replacement of power contactor of capacity 60 Amp, 4 pole, as per existing complete all as specified and directed.
Supply & fix in repair for electronic timer as per existing complete all as specified and directed.
Supply & fix in replacement electronic motor protection relay inbuilt CT, trip indication, current unbalance, phase sequence reversal complete all as specified and directed.
Supply & fix in repair for single phase preventor 415 Volt for the motors as per existing complete all as specified and directed.
Supply & fix in repair for ampere meter with CT,s of range 0-30 amps as per existing complete all as specified and directed.
Supply & fix in repair for voltmeter with PT,s of range 0-500 volts as per existing complete all as specified and directed.
Supply & fix in repair for over load relay coil 37-50 Amp, 230 volts type RT23V as per existing complete all as specified and directed.
Supply & fix in repair for MCB TP of capacity 20-63 amps, c series 415 volts as per existing complete all as specified and directed.
S&F in replacement of old U/S gland packing with new to the pump set of any sizes/capacity complete with neoprene rubber gasket, jointing material and incl nuts/bolts/washer of suitable size etc complete all as specified and directed.
Supply and fix in repair MS nuts, bolts with washer of 5/8 inch dia 4 inch long complete all as specified and directed.
Material and labour for cutting of bituminous road or any type of floor for laying of pipe / cables not exceeding 1.5 meter wide and not exceeding 1.5 meter deep including refilling / with material and , watering well ramming / compacting and making good with PCC 1;2;4,type B-1, 100mm thick complete all as specified and directed by Engr-in-Charge.
S&F in repair 80mm bore size column pipe, both side flanged GI Medium grade ISI marked (Each of 3 m length) including taking out old corroded column pipe both side flanged complete all as specified and directed.
,---ditto--- all as per srl item No 41 above but 65 mm bore pipe complete.
,---ditto--- all as per srl item No 41 above but 50 mm bore pipe complete.
Supply and fix jointing kit for submersible cable of 1100 volts grade of 4/6 sqmm 3 core complete all as specified and directed.
Supply only submersible copper cable PVC insulated over all sheethed flat ISI marked of 1100 volts grade of 6 sqmm 3 core complete all as specified and directed.
Supply only submersible copper cable PVC insulated over all sheethed flat ISI marked of 1100 volts grade of 10 sqmm 3 core complete all as specified and directed.
Disconnecting and taking out exisitng LT over heated or burnt cable terminal/ joint at panel /feeder pillar & unserviciable portion of LT cable of any size, after that stretching/ opening cable to suitable required length etc and fixing aluminium lugs / joint material and suitable nuts bolts & washer etc complete all as specified and directed by Engr-in-charge
Labour only for checking the serviceability of the different spares/ component / parts of the starter and motor pump set / panel of any capacity at site complete all as directed by Engr-in-charge
Dismantaling of pressure pump set of cap 0.5 to 1 HP, single phase, 230 volts, 50Hz, AC supply after disconnecting electric connection, repairing/ replacing defective parts as ordered, re-assembling and testing including replacing worn out nuts, bolts, washers complete and electric connection after following repairs as directed by Engineer-in-charge :- Note : - (i) The spare part required for replacement shall be measured & paid for separately as supply only under item
Supply only ball bearing as per existing. Make:- NBC/SKF/TATA
Cutting of burnt winding and rewinding the stator with supper enamelled copper wire of suitable size and class of insulation including insulation paper, sleeves, thimbles etc.
Supply only seal as per existing.
Supply only relay kit
Supply only Auto switch as per existing.
Supply and fix in replacement of changover switch 250 Amp, 415 volts, 4 pole off load without sheet enclouser suitable for existing panel complete all as specified and directed.
Taking out old unsv 80mm bore steel tubing and connections from walls and ceilings, trenches, under floor or road complete all as specified and directed.
,---ditto--- all as per srl item No 51 above but 100 mm bore pipe complete.
M&L for 80mm bore galvanised steel tubes "medium grade " (ISI marked) with all fitting (ISI marked) and fixed complete to walls and ceilings or laid in floors/trenches and under road complete all as specified and directed of the following sizes :-
,---ditto--- all as per srl item No 53 above but 100 mm bore pipe complete.
Supplying, laying, jointing and testing in repair of ductile iron pipe class K-9 confirming to IS : 8329 of bore 200 mm (ISI marked), spigot & socketed ends centrifugally cast suitable for rubber tyton joints complete all as specified and as directed.
Supplying, laying, jointing and testing in repair of ductile iron pipe class K-9 confirming to IS : 8329 of bore 150 mm (ISI marked), spigot & socketed ends centrifugally cast suitable for rubber tyton joints complete all as specified and as directed.
Supplying, laying, jointing and testing in repair of ductile iron pipe class K-9 confirming to IS : 8329 of bore 100 mm (ISI marked), spigot & socketed ends centrifugally cast suitable for rubber tyton joints complete all as specified and as directed.
M&L ductile iron fittings, IS-1538 marked viz bends, tapers, reducers, tee pieces (single or double branch) any type, angle / radius and straight connecting pieces, but all ends flanged, size of pipe upto 150 mm bore complete all as specified.
S&F in repair pressure pump of capacity 0.5 HP single phase 230 volts 50 HZ AC supply including testing and commissioning. complete as specified and directed by Engineer-in-charge. Make :- KSB or equivelent as approved by GE
S & F in replacement of CI foot valve of size 150 mm with gun metal working parts, ISI marked with all fittings all as specified and directed by EIC
,---ditto--- all as per item No 60 above but 80 mm size complete all as specified and directed.
,---ditto--- all as per item No 60 above but 50 mm size complete all as specified and directed.
,---ditto--- all as per item No 60 above but 40 mm size complete all as specified and directed.
Testing of drinking water from borewell / UG sump to analysis the following parameters as per IS 10500:2000 through NABL accredited lab (a) Chemical parameter of water (b) Bacteriological test of water
Providing area cleaning/sweeping of preimises water supply installation (Ph House) including cutting out green vegetation, roots, bushes, Tree branches, picking polothine and other unwanted material from the installation area and maintaining the ground surrounding the installation and removing the same out side the defence area as directed by Engr in charge. The approx area of installation kept clean all as under. (1) PH7 -8000Sqm (2) Ghotic line - 6900 Sqm (3) Peru line - 6100 Sqm (4) Vijay Line PUMP HOUSE - 6000sqm Note :- (i) if contractor is fail to clean the area of installation compete in all respect else recovery @ 5000 per job shall be recovered from his dues and contractors claim shall not enter on this account. (ii) Area shall be maintained begning from commencement of contract to completion date and paid once only (iii) Necessary T&P reqd for the work shall be arrange by contractor
M & L for non return valves, class PN 1.0 of undermentioned type and 150 mm size with cast iron body and both ends flanged, IS-14846 marked comlete with neoprene rubber gasket ,jointing material and incl nuts/bolts/washer of suitable size etc including taking down old unsv complete as specified and directed by Engineer-in-charge.
M&L for water high pressure gauge including socket welded to measure pressure in the delivery pipe 0-300 Psi Kg/CM2 Make:-FE/BIG/GURU, RAMCO
Peoviding water tanker 5000 ltr capacity for carrying water inside milt area, if required due to any pump failuer at Zone II area
Excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5 m in depth and getting out in soft/loose soil including trimming of tree roots in trenches complete all as specified and directed.
Returning, filling-in, including spreading, watering and well ramming in layers not exceeding 25 cm thick each, in soft /loose soil complete all as specified and directed.
Removing excavated surplus soil to a distance not exceeding 50 m and depositing where directed at a level not exceeding 1.5 m above the starting point complete all as specified and directed.
M & L Sand cushioning to PVC under ground cable with screened and washed tibba sand (non cohessive) and punning to provide a required cover complete all as specified and directed. Note : Punned thickness shall only be measured for payment.
M & L Bricks for protection cover to under ground cable (with old size sub class ‘B’ bricks laid flat abutting each other with width of protection being equal to length of brick. The gap between adajcent bricks shall not exceed 10 mm as directed by Engineer-in-Charge.
M&L for PCC (1:3:6) type C1 using 20 mm graded aggregate for making good the disturbed portion of road/floor/platform etc including form work and compaction etc complete all as specfied and directed .
M&L for boaring of existing road/path for laying of GI pipe for protection of cable including making good distrubed area/surface all as directed by Engr in charge
Supply, Laying, Jointing, testing & commissioning LT under ground cable XLPE insulated, screened PVC bedded, galvanised steel strips or wire armoured, heavy duty with multi stranded aluminium conductor, 1100 volts grade (ISI marked) laid in trenches, ducts, pipes or fixed on poles of size 35 Sqmm 3 ½ core including taking down old unserviceable cable complete all as specified and directed.
Supply, Laying, Jointing, testing & commissioning LT under ground cable XLPE insulated, screened PVC bedded, galvanised steel strips or wire armoured, heavy duty with multi stranded aluminium conductor, 1100 volts grade (ISI marked) laid in trenches, ducts, pipes or fixed on pole of size 50 Sqmm 3 ½ core including taking down old unserviceable cable complete all as specified and directed.
Repair & maintenance of existing header, welding work, jointing of pipe, butter fly valve etc of header as per eixsting shape upto 150 mm to 400 mm dia pipe complete all as specified and directed.
Replacement of existing MS pipe150 mm dia including welding work fitting like as (flanged, rubber sheet, bend, nut bolt etc) complete all as specified and directed .
M & L for sluice valves, class PN 1.6 of 80mm bore size with cast iron body, non rising type and cast iron wheel head, both ends flanged, IS-14846 marked comlete with neoprene rubber gasket, jointing material and incl nuts / bolts / washer of suitable size etc including taking down old unsv complete all as specified and directed.
,---ditto--- all as per srl item No. 80 above but of size 100 mm bore.
,---ditto--- all as per srl item No. 80 above but of size 150 mm bore.
,---ditto--- all as per srl item No. 80 above but of size 200 mm bore.
M & L for non return valves, class PN 1.0 of 80mm bore size with cast iron body and both ends flanged, ISI marked comlete with neoprene rubber gasket, jointing material and incl nuts / bolts / washer of suitable size etc including taking down old unsv complete all as specified and directed.
,---ditto--- all as per srl item No. 84 above but of size 100 mm bore complete.
M & L for Butterfly valve 100 mm dia, ISI marked complete with all fittings/accessories, required for fixing in existing header including taking down old unsv complete all as specified and directed.
Supply calcium based high strength granular chlorination chemical (calcium hypochlorite having chlorine 65% to 70% ) for water treatment. Granular material shall be free of foreign material decomposing at 177 C soluble in water and alcohol not hygroscopic practically clear in water solution at saturation level. The material should not contain more than 5% to 10 % moisture. Granular size should be as follows:- Mesh passing through -100 BSS 1.5 % maximum iron as Fe 0.05% maximum Mn 40 PPM maximum Mol wt 142.98, Toxicity :Oral rate LD 50-850 mg/kg. duly tested from approved laboratory packed in a fibre drum duly sealed granular type from manufacturer or authorised dealer/distributor complete all as specified and directed. Note- Brand name/batch number and complete particulars of manufacturer should be printed on the container/packing. Make:-“M/S Sree Rayalaseema Hi-Strength Hypo Ltd (Puri Chlor brand Calcium Hypo Chlorite) or any make approved by E-in-C's Branch”.
M&L Earthing complete as per electrical plate No 5 of MES SSR Part I with galvanised steel plate earth electrode 60 cm x 60 cm x 6.0mm, burried directly vertically in ground in a pit of depth not less than 2.5 metres below ground level with the top edge of earth plate at a depth not less than 1.8m below normal ground level connected to and including galvanised iron or steel earth strip 32X6 mm by means of bolts, nuts, check nuts and washers of galvanised iron or steel. Earthing wire protected by galvanised iron or steel pipe 40mm bore light grade and connected to continuous earth wire on pole/ test point. Watering pipe shall be 20mm bore GI medium grade. The earthing shall be inclusive of excavation and earth work in any type of soil,charcoal, salt,funnel , PCC pit and RCC cover complete all as specified & directed. Note 1 - following items deemed to be included in quoted rate (a) Earth electrode. (b) Main earthing lead from earth electrode to test point and further to equipment to be earthed upto 7.5 metre. (c) Material and labour for connecting earth electrode and earthing lead as specified. (d) Adequate quantity of charcoal dust and common salt as per direction. (e) All labour involved including testing of earth net work. (f) Excavation and earth work or drilling hole for electrode. (g) P.C.C. pit and C.I. cover. (h) Funnel with watering pipe, wire mesh and copper lugs etc. as specified. (j) G.I. protection pipe of size ordered specified for protection of earthing lead from mechanical injury or tempering. Note 2 - On testing after completion if the desired earth resistance is not obtained the earthing will be redone at no extra cost.
Taking out of old existing unserviceable earthing lead of 32 x 6 mm size of galvanised iron strip or steel strip complete all as specified and directed.
M&L for Earth continuity conductor or main earthing lead 32 X 6mm GI strip fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required complete all as specified and directed.
Taking out of old existing unserviceable GI protection pipe of dia 40 mm galvanised iron with all fittings complete all as specified and directed.
Supply & fix tubes 40 mm dia 'light grade', galvanised, with all fitting laid in trenches for protection of GI strip complete all as specified and directed.
M&L for taking out old/existing earthing pit by removal of unserviceale funnel and cover of earthing complete all as specified and directed.
M&L for Making earthing pit as per electrical plate No.2 with wire mesh, CI cover, Frame, funnel including necessary PCC work all as directed by EIC with testing complete all as specified and directed.
M&L for preparation of old painted surface of electrical panel inner and outer surface by scrubbing with iron brush and applying two coat synthetic enamel paint with spray machine complete. Length (0.5 m to 1 m), Height (0.5m to 1m), Breadth( up to 0.5m)
,---ditto--- all as per item No. 95 above but of size complete Length (0.5 m to 1 m), Height (1m to 2m), Breadth (up to 0.5m)
,---ditto--- all as per item No. 95 above but of size complete Length (1 m to 2 m), Height (1m to 2m), Breadth( up to 0.5m)
Material and labour for repairing of manually operator shutter of pump house by welding, oiling, greasing etc including minor repair parts like spring,nut and bolts applying two coat synthetic enamel paint of existing colour at ineer and outer side of shutter as specified and directed.
M&L for writing latters or figures (block, Romen, Italic,or indian) n exc. 30 Cm height, before writing painter will scrub/clean the floor/wall as per requirement dimention and double coat a base paint
M& L for repairing of LT panel including welding of doors, fixing of hinges, brazing complete all as specified and directed by EIC.
Supply and fix in repair aviation / obstruction light on over head tank with wiring with 1.5 Sqmm 2 core wire up to the DB at base of OHT complete all as specified and directed by engr in charge.
Preparation of old painted steel surface of centrifugal pump with motor up to 50 HP and applying two coats of synthetic enameled paint over and incl one coat of red oxide primer complete all as specified and directed by engr in charge.
S&F in repair submersible pump set with motor of capacity 10 HP with head 29meter and discharge capacity 80 cum/hr, 3 phase, 230/415 volts, 50Hz, AC supply including testing and commissioning complete as directed and specified by Engineer-in-charge. Make :- KSB / crompton / Kirloskar or equivalent as approved by GE.
Preparation of old painted GI / MS pipe surfaces upto 150 mm dia at various pump house and applying two coats of synthetic enamelled paint over and incl one coat of red oxide primer complete all as specified and directed by engr in charge.
Supply only drinking water chlorine test kit of range min 0.2 PPM to Max 5 PPM as per specified and directed by EIC. Make - Aquasol or equivelent as approved by GE
Supply only digital TDS meter kit as per specified and directed by EIC
Supply only digital Turbidity meter as per specified and directed by EIC
Supply only shock treatment chart (50x70 cm) with combined language hindi and english,chart should be laminated on both sides as per specified and directed by EIC
S & F in reapir insulation mat of thickness 3 to 6mm thick as per IS 15652, ISI marked of size 1m x 2m to safegaurd of electric shock as per specified and directed by EIC
S &F in repair notice board of size 3 feet x 4 feet of premium material green colour notice board / soft board / pin- up display board with 50 pins for pump house with Alloy Aluminium Frame, softboard Core, Premium Flocked Fabric (Velvet) Cloth surface & Virgin ABS Corner complete all as specified and directed.
Note:- (a) Contractor must deploy a faullt/leakage investigating and rectifying team within 4 hours of intimation of fault for attendimg the complaint and recitify it within 24 hours. (b) If contractor is failed to comply with the then penalty of Rs 1000 per day will be deducted (c) Material like MCB, MCCB, Starter (all type and size), Cable (all type), GI pipe, Column pipe, DI pipe, Sluice valve, NRV, butterfly valve etc shall be procured by contractor in one time for complete quantity as mentioned in BOQ, of approved make from authorised dealer of manufacturers within 30 days of date of commencement and purchase vouchers & manufacturers test certificate ( where applicable) shall be submitted by contractor before clam of payments (d) The contract sum shall be calculated by deducting the amount shown in Credit Schedule attached to this tender, from total amount of Schedule 'A'/BOQ
Gaurav & company
C.P.Computers
DIVYA ASSOCIATES
M/S TRADE LINKERS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .