Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹11.1 LAccepted-AOC | L1 | Accepted-AOC 1st lowest | |
| 2 | L2₹11.7 L+₹60,620 (5.45%)Rejected-Finance | L2 | Rejected-Finance Being not a lowest | |
| 3 | L3₹14.6 L+₹3.5 L (31.6%)Rejected-Finance 150 BC LINE MALL ROAD MEERUT CANTT 250001 | MEERUT | UTTAR PRADESH | 250001 | L3 | Rejected-Finance Being not a lowest | |
| 4 | L4₹14.7 L+₹3.6 L (32.2%)Rejected-Finance | L4 | Rejected-Finance Being not a lowest | |
| 5 | L5₹15.4 L+₹4.3 L (38.8%)Rejected-Finance | L5 | Rejected-Finance Being not a lowest |
Tender Value
₹20 L
EMD Value
₹40,000
Closing Date
25 Mar 2022, 6:00 pmClosed
GE (WEST) PATHANKOT
GE (WEST) PATHANKOT
REPAIR/MAINT TO SUMMER APPLIANCES, DESERT COOLER, WATER COOLER, DEEP FREEZER, REFRIGERATORS, SPLIT/WINDOW TYPE AC AND AC PLANT INCL ALLIED SERVICES UNDER AOR OF GE (WEST) PATHANKOT
2022_MES_510427_1
GE/PKT-67/2021-22
Open Tender
Miscellaneous Works
Item Rate
180 days
GE (WEST) PATHANKOT
Please refer tender documents
9 documents required · 9 mandatory
₹500
GE (WEST) PATHANKOT
₹40,000
Yes
31 Mar 2022
25 Feb 2022
28 Mar 2022
25 Feb 2022
25 Mar 2022
12 Mar 2022
26 Feb 2022 - 10 Mar 2022
Amount
Servicing of water /air type cooling tower complete by changing its acrilic fins inside the bottle and pipes, nozzeles etc including cleaning and spray painting with synthetic enamelled paint complete all as specified and directed by Engr- in -charge.
Repair and maintenance of Central AC plant of capacity 2X50 TON ton at Kiran Auditorium including supply and fixing in replacment of following parts including testing complete:- a) S&F of air filter As per existing size - (6Nos) b) V-belt B-83 =02 No c) Tyer Coupling TC93 - (2 (Nos) d) Servicing of electric motors . e) Cleaning the AHU - (2 Nos) f) S&F of air filter As per existing size - (6Nos)
M&L for replacement of old unsv compressor oil (servo) forAC plant complete all as specified and directed by Engr- in -charge. Make :- Indian oil/ BPCL/HPCL
M&L for descaling of condensor of 50 TR capacity of AC Plant with dilute chemical solutionand with the help of nylon brush 3-4 times followed by the cleaning and washing with water so that chemical solution is completely clean out from system complete all as specified and directed by Engr- in -charge.
S&F Oil seal assembly for 50 ton compressor of make voltas model T- 5000 complete all as specified and directed by Engr- in -charge.
M&L for rewinding of AHU motor of 15 HP three phase with super enamalled copper wire of appropriate gauge with insulating material complete after removing old burnt winding wire include servicing, change the unserviceble Bush & shaft & testing complete all as specified and directed by Engr- in -charge.
M&L for rewinding of Condensor/Chiller Pump motor of 7. 5 HP three phase with super enamalled copper wire of appropriate gauge with insulating material complete after removing old burnt winding wire include servicing, change the unserviceble Bush & shaft & testing complete all as specified and directed.
Repair, rewinding and maintenance of voltage stabilizer of any company/ make of capacity 4 KVA after disconnecting the voltage stabilizer from machine, rewinding transformer with super enamelled copper wire of existing gauge complete all as specified and directed
Repair, rewinding and maintenance of voltage stabilizer of any company/ make of capacity 5 KVA after disconnecting the voltage stabilizer from machine, rewinding transformer with super enamelled copper wire of existing gauge complete all as specified and directed
S & F Cutout relay as per existing make suitable for voltage stabilizer complete all as specified and directed.
S&F Electric circuit suitable for voltage stabilizer complete all as specified and directed.
S & F Indicator lamp as per existing make suitable for voltage stabilizer complete all as specified and directed.
S & F Flexible wire suitable for voltage stabilizer complete all as specified and directed.
S& F in replacement of existing UNSV Power Contactor ML-2 coil voltage 240 Volt all as specified and directed by Engr- in -charge. Make ;- Havells /Legrand
S& F in replacement of existing UNSV Contactor ML-1 coil voltage 240 Volt all as specified and directed by Engr- in -charge. Make;-L & T
S&F in replacement of UNSV MCCB 160 amps , triple pole 35 KA rupturing capacity fixing in position and making cable conection including testing on load complete all as specified and directed by Engr- in -charge.
S&F in replacement of UNSV MCCB 200 amps , triple pole 35 KA rupturing capacity fixing in position and making cable conection including testing on loadall as specified and directed by Engr- in -charge.
Taking down defective AC , window type of capacity upto 2 ton of any make after disconnecting electric connections and transporting to workshop from site, dismantling the AC and taking out burnt rotary / reciprocating compressor unit from AC and replacing the same with new compressor of existing make with 12 months warranty including gas charging and testing complete all as specified and directed by Engr- in -charge. Make: TOTAL LINE/HIGHLY/Voltas
S&F Starting relay for window AC, split AC. fixed in repair all as specified and directed by Engr- in -charge.
S&F Thermostate switch for window AC, hot and cold type fixed in repair all as specified and directed by Engr- in -charge.
S&F Swing motor for window type AC / split type AC of capacity 1.5 ton as per existing make LG/Voltas/whirlpool fixed in repair complete all as specified and directed by Engr- in -charge..
S&F Running capacitor 50 +2 to 6 MFD (ISI Marked) for window AC/ split AC 1.5/2 Ton fixed in repair all as specified and directed by Engr- in -charge.
S&F Running capacitor 60 +2 to 6 MFD (ISI Marked) for window AC/ split AC 1.5/2 Ton fixed in repair all as specified and directed by Engr- in -charge.
S&F Running capacitor 45 +2 to 6 MFD (ISI Marked) for window AC/ split AC 1.5/2 Ton fixed in repair all as specified and directed by Engr- in -charge.
S&F Running capacitor 36 +2, to 6 MFD (ISI Marked) for window AC 1.5/2 Ton fixed in repair all as specified and directed by Engr- in -charge.
S&F Front grill of window AC, capacity 1.5/2 ton suitable for AC of Make:- LG/ Carrier/ Sidwal/ Whirlpool as per existing fixed in repair complete all as specified and directed by Engr- in -charge.
S&F Condensing fan of window type AC of capacity 1.5 ton as per existing fixed in repair complete all as specified and directed by Engr- in -charge. MAKE -LG/VOLTAS/CARRIER
S&F Blower fan of window type AC of capacity 1.5 ton as per existing fixed in repair complete all as specified and directed by Engr- in -charge.
S&F Sheet metal enclosure with MCB single pole 20 Amp for AC fixed in repair complete all as specified and directed by Engr- in -charge.
Servicing of window type AC/ split type AC of capacity 1.5 ton of any make at site with complete washing/ removing of dust from blower fan and necessary oiling the blower motor complete all as specified and directed by Engr- in -charge..
S&F Blower Motor (ISI marked ) 1/5 HP capacity of window type AC fixed in repair complete all as specified and directed by Engr- in -charge.
S&F in replacement of UNSV Recycle valve kit to maintain the desired temperature of cooling system of window type AC /split type AC as per requirement including gas charging, fixed in repair complete all as specified and directed by Engr- in -charge..
S&F in replacement of UNSV PCB circuit Hot & cold for window type AC fixed in repair complete all as specified and directed by Engr- in -charge. Make- LG /Voltas
S&F in replacement of unsv condensing coil for window type AC of capcity 1.5 ton including gas charging, complete all as specified and directed by Engr- in -charge.
S&F Copper pipe of dia 1/4 inch fixed in repair complete all as specified and directed by Engr- in -charge.
S&F Copper pipe of dia 3/8 inch fixed in repair complete all as specified and directed by Engr- in -charge.
S&F Copper pipe of dia 1/2 inch fixed in repair complete all as specified and directed by Engr- in -charge.
Taking down defective split type AC of any capacity /make after disconnecting electric connections and transporting to workshop from site ,dismantling the AC and taking out burnt rotary / reciprocating compressor unit from AC and replacing the same with new compressor of existing make with 12 months warranty including gas charging and testing complete all as specified and directed by Engr- in -charge. Make: TOTAL LINE/HIGHLY/ CARRIER
Taking down defective split type AC of any capacity /make after disconnecting electric connections and transporting to workshop from site, dismantling the AC and taking out burnt rotary / reciprocating compressor unit from INVERTER AC and replacing the same with new compressor of existing make with 12 months warranty including gas charging and testing complete all as specified and directed by Engr- in -charge. Make: TOTAL LINE/HIGHLY/ CARRIER
Taking down defective indoor Unit for Split AC 1.5 Ton and replacing the same with new for existing make of AC complete all as specified and directed by Engr- in -charge. Make: Whirlpool.
S&F in replacement of PCB circuit hot and cold to split type AC for existing makes of AC complete all as specified and directed by Engr- in -charge.
S&F in replacement of PCB circuit for INVERTER AC hot and cold to split type AC for existing makes of AC complete all as specified and directed by Engr- in -charge.
S&F Blower Motor (ISI marked ) of split type AC fixed in repair complete all as specified and directed by Engr- in -charge.
S&F Condensor fan Motor (ISI marked ) of split type AC fixed in repair complete all as specified and directed by Engr- in -charge..
S&F in replacement of UNSV Air filter for split type AC of any capacity complete all as specified and directed by Engr- in -charge.
S&F in replacement of UNSV Remote control with two AAA battery for split type AC of capacity 1.5 ton /2 ton suitable for make of LG/ Carrier/ Sidwal/ Whirlpool as per existing complete all as specified and directed by Engr- in -charge .
S&F Insulation material for copper pipe outer covering 25mm thick fixed in repair complete all as specified and directed by Engr- in -charge.
S&F in replacement condensing fan for split type AC of capacity 1.5 ton /2 ton complete all as specified and directed by Engr- in -charge.
S&F in replacement Blower fan for split type AC of capacity 1.5 ton /2 ton complete all as specified and directed by Engr- in -charge.
S&F PVC flexible copper conductor sheathed cable of size 2.5 Sqmm 3 core fixed in repair complete all as specified and directed by Engr- in -charge.
Supply & Charging Refrigerant R -134 complete one time for top up or making full qty as per pressure requirment of plant and testing for any leakage and rectifying the same all as specified and directed by Engr- in -charge. .
Supply & charging Refrigerant R-22 to Air conditioner (window type /split type) of any capacity and make all as specified and directed by Engr- in -charge. Make ;- Mafron
Supply & charging Refrigerant R-32 to Aiir conditioner (window type /split type) of any capacity and make all as specified and directed by Engr- in -charge
Supply & Charging Refrigerant R-410 to Air conditioner (window type /split type )of any capacity and make complete all as specified and directed by Engr- in -charge. Make ;- Mafron
Repair, rewinding and maintenance of voltage stabilizer of any company/ make, of capacity upto 0.5 KVA, after disconnecting the voltage stabilizer from machine, strip opening the stabilizer, finding faults including rewinding transformer with super enamelled copper wire of existing gauge including replacement of unserviceable parts like voltmeter, Amp meter, cutout relay, electric circuit, indicator lamp, top plug, flexible wire including necessary painting with two coats of synthetic enamel paint after proper scratching and preparing the surface complete all as specified and directed by Engr- in -charge
Repair, rewinding and maintenance of voltage stabilizer of any company/ make, of capacity upto 1 KVA, after disconnecting the voltage stabilizer from machine, strip opening the stabilizer, finding faults including rewinding transformer with super enamelled copper wire of existing gauge including replacement of unserviceable parts like voltmeter, Amp meter, cutout relay, electric circuit, indicator lamp, top plug, flexible wire including necessary painting with two coats of synthetic enamel paint after proper scratching and preparing the surface complete all as specified and directed by Engr- in -charge
Repair, rewinding and maintenance of voltage stabilizer of any company/ make, of capacity upto 2 KVA, after disconnecting the voltage stabilizer from machine, strip opening the stabilizer, finding faults including rewinding transformer with super enamelled copper wire of existing gauge including replacement of unserviceable parts like voltmeter, Amp meter, cutout relay, electric circuit, indicator lamp, top plug, flexible wire including necessary painting with two coats of synthetic enamel paint after proper scratching and preparing the surface complete all as specified and directed by Engr- in -charge.
Repair, rewinding and maintenance of voltage stabilizer of any company/ make, of capacity upto 3 KVA, after disconnecting the voltage stabilizer from machine, strip opening the stabilizer, finding faults including rewinding transformer with super enamelled copper wire of existing gauge including replacement of unserviceable parts like voltmeter, Amp meter, cutout relay, electric circuit, indicator lamp, top plug, flexible wire including necessary painting with two coats of synthetic enamel paint after proper scratching and preparing the surface complete all as specified and directed by Engr- in -charge.
S & F Voltmeter as per existing make suitable for voltage stabilizer complete all as specified and directed.
S & F Amp meter as per existing make suitable for voltage stabilizer complete all as specified and directed.
S & F Cutout relay as per existing make suitable for voltage stabilizer complete all as specified and directed.
S& F Electric circuit suitable for voltage stabilizer complete all as specified and directed.
S & F Indicator lamp as per existing make suitable for voltage stabilizer complete all as specified and directed.
S&F in replacemen Flexible wire suitable for voltage stabilizer complete all as specified and directed.
S&F in replacement UNSV Submersible water lifting pump for desert cooler, 230 V ,50 Hz fixed in repair include taking down old one complete all as specified and directed by Engr- in -charge. Make : Khaitan/ Cool Home/Orison.
S&F in replacement of UNSV Fan motor of desert cooler 1/7 HP with fan blade & legs single phase 230 V, 50 Hz fixed in repair complete all as specified and directed.by Engr- in -charge. Make : Khaitan/ Cool Home/ AUE
M/L for rewinding of D/cooler fan motor of 1/7 HP single phase 3 speed with super enamalled copper wire of appropriate gauge with insulating material complete after removing old burnt winding wire include servicing, change the unserviceble Bush & shaft & testing complete all as specified and directed by Engr- in -charge.
S&F in replacement Rubber pipe 15mm dia (ISI marked) heavy grade for desert cooler fixed in repair complete all as specified and directed by Engr- in -charge.
S&F in replacement Wood wool pad of size 24" x 18" (set of 3) for desert cooler fixed in repair complete all as specified and directed byEngr- in -charge.
S&F in replacement Pad retaining jalli 16 SWG of suitable size of desert cooler (set of 3) fixed in repair complete all as specified and directed by Engr- in -charge.
S&F in replacement Water distributor for water connection of desert cooler complete all as specified and directed by Engr- in -charge.
S&F in replacement Plug top three pin 15 Amps complete all as specified and directed by Engr- in -charge.
S&F in replacement Plug top three pin 5 Amps complete all as specified and directed by Engr- in -charge.
S&F in replacement Ball valve of size 15mm high pressure of PTMT with epoxy coated aluminium rod and high density plastic ball screwed for iron pipe fixed in repair complete all as specified and directed by Engr- in -charge.
S&F in replacement PVC connection of size 15mm x 450 mm superier quality fixed in repair complete all as specified and directed by Engr- in -charge.
S&F in replacement Stop valve of PTMT of size 15mm, any colour screwed for iron pipe (ISI marked) fixed in repair complete all as specified and directed by Engr- in -charge.
Removing of desert cooler coolers from site after disconnecting the electric connection and water connection taking out rusted bottom and replacing with new bottom as per existing size with 24 gauge PGI sheet and transporting back from wksp and installing at site including electric and water connections complete all as specified and directed.by Engr- in -charge
S&F in replacement Side shutter of Desert cooler as per existing size with 24 gauge PGI sheet of desert coolercomplete all as specified and directed.
Removing of desert cooler coolers from site after disconnecting the electric connection and water connection taking out rusted Side legs and replacing with new legs as per existing size with 24 gauge PGI sheet and transporting back from wksp and installing at site including electric and water connections complete all as specified and directed by Engr- in -charge..
S&F in replacement Capacitor 4 MFD (ISI Marked) fixed in repair all as specified and directed by Engr- in -charge.
S & Charging Refrigerant R 134 a/R-32 to Refrigerators of any capaciy, & replace old drier and capillary tube as per existing size any length and make all as specified and directed by Engr- in -charge. .
S&F in replacement Starting relay No CAJ -2612 for water cooler all as specified and directed by Engr- in -charge.
S&F in replacement Starting relay No CAJ -34 for water cooler fixed in repair all as specified and directed Engr- in -charge.
S&F in replacement Starting relay No AHR 13 for water cooler fixed in repair all as specified and directed Engr- in -charge.
S&F in replacement Starting capacitor of capacity 80 / 100 MFD (ISI Marked) for water cooler fixed in repair all as specified and directed by Engr- in -charge.
S&F in replacement Starting capacitor of capacity 100 / 120 MFD (ISI Marked) for water cooler fixed in repair all as specified and directed by Engr- in -charge.
S&F in replacement Over load protector of any size for water cooler fixed in repair all as specified and directed by Engr- in -charge.
S&F in replacement Thermostat switch of any size for water cooler fixed in repair all as specified and directed by Engr- in -charge.
Taking out defective condensing coil from water cooler and supply and fix new condensing coil suitable for unit model CAJ-2612 with gas charging of R 134a all as specified and directed by Engr- in -charge Make of cooler :- Usha/Sidhwal/Blue Star/Sri Ram
Taking out defective condensing coil from water cooler and supply and fix new condensing coil suitable for unit model CAJ-34 with gas charging of R 134a all as specified and directed by Engr- in -charge Make of cooler :- Usha/Sidhwal/Blue Star
Taking out defective condensing coil from water cooler and supply and fix new condensing coil suitable for unit model AHR-13 with gas charging of F-22 all as specified and directed by Engr- in -charge. Make of cooler :- Usha/Sidhwal/Blue Star
S&F in replacement new Condensing fan blade for water cooler of any size fixed in repair all as specified and directed by Engr- in -charge (As per sample) .
S&F in replacement Self closing bib cock chromium plated for water cooler of any size fixed in repair all as specified and directed by Engr-in-charge.
S&F in replacement Rubber pipe 1.25 inch dia for water waste of water cooler all as specified and directed by Engr- in -charge. .
S&F in replacement Rubber gasket cover of size 1cmx1cm for top cover of water cooler all as specified and directed by Engr- in -charge
Removing of water cooler of model No CAJ-2612 from site after disconnecting electric & water connections and transporting to workshop, taking out burnt compressor and replacing with new compressor suitable for refrigerent gas R134a of the same make/ company of existing water cooler with 12 months warranty including leakage test, gas charging, testing including transporting back from workshop and installing at site complete all as specified and directed by Engr- in -charge. Make - COPELAND/ VOLTAS
Removing of water cooler of model No CAJ-34 from site after disconnecting electric & water connections and transporting to workshop, taking out burnt compressor and replacing with new compressor suitable for refrigerent gas R134a of the same make/ company of existing water cooler with 12 months warranty including leakage test, gas charging, testing including transporting back from workshop and installing at site complete all as specified and directed by Engr-in-charge..Make - COPELAND/ VOLTAS
Removing of water cooler of model No AHR-13 from site after disconnecting electric & water connections and transporting to workshop , taking out burnt compressor and replacing with new compressor suitable for refrigerent gas R134a of the same make/ company of existing water cooler with 12 months warranty including leakage test, gas charging, testing including transporting back from workshop and installing at site complete all as specified and directed. at site complete all as specified and directed.Engr- in -charge..Make - COPELAND/ VOLTAS
S&F Thermostat switch for refrigerator fixed in repair all as specified and directed by Engr-in-charge.
S&F in replacement Blower motor of capacity 1/35 HP for water cooler of capacity 40/80, 60/120 Ltrs fixed in repair all as specified and directed by Engr- in -charge
S&F in replacement Blower motor of capacity 1/10 HP for water cooler of capacity 150 Ltrs fixed in repair all as specified and directed by Engr- in -charge.
Supply & Charging Refrigerant R 134 a / R 22 /R-32 to Water Cooler of any capaciy, & replace old drier and capillary tube as per existing size any length and make all as specified and directed by Engr- in -charge. .
Removal of rusted bottom and repair of body of water cooler of any make and capacity with MS sheet 0.71mm thick, pedestal legs and fixing bottom sheet of suitable existing size and pedstal legs,frame of water cooler by angle iron of size 25x25x3mm and welding including applying one coat of anti corrosive paint by spray machine before fixing all as specified and directed by Engr- in -charge. .
Removal of rusted bottom and repair of body of refrigerator of any make and of capacity 165/ 300 ltrs with MS sheet , pedestal legs and fixing bottom sheet of suitable existing size and pedestal legs, frame of refrigerator with angle iron and welding including applying one coat of anti corrosive paint by spray machine before fixing all as specified and directed by Engr- in -charge.
Removing refrigerator of capacity 280/300ltrs from site after disconnecting electric connection and transporting to workshop , taking out burnt compressor and replacing with new compressor 1/6 HP Suiteble comperessor of the same make/ company of refrigerator with 12 months warranty including leakage test, R134a gas charging, testing including transporting back from workshop and installing at site complete all as specified and directed by Engr- in -charge
Removing refrigerator of capacity 165l//190 litrs from site after disconnecting electric connection and transporting to workshop , taking out burnt compressor and replacing with new compressor1/8 hp R134a compitable comperesssor of the same make/ company of refrigerator with 12 months warranty including leakage test, R134a gas charging, testing including transporting back from workshop and installing at site complete all as specified and directed by Engr- in -charge.
Removing refrigerator of capacity 320ltrs doubble door from site after disconnecting electric connection and transporting to workshop , taking out burnt compressor and replacing with new compressor R134a compitable comperesssor of the same make/ company of refrigerator with 12 months warranty including leakage test, R134a gas charging, testing including transporting back from workshop and installing at site complete all as specified and directed by Engr- in -charge.
Removing Deep Freezer of capacity 200/300 ltrs from site after disconnecting electric connection and transporting to workshop , taking out burnt compressor and replacing with R134 a compitable comperesssor of the same make/ company of refrigerator with 12 months warranty including leakage test, R134a gas charging, testing including transporting back from workshop and installing at site complete all as specified and directed by Engr- in -charge.
S&F in replacement defective condensing coil from deep freezer and supply and fix new condensing coil with gas charging of R 134a all as specified and directed by Engr- in -charge Make of cooler :- voltas/ blue star/ usha
S&F in replacement Condensor fan motor for deep freezer of any capacity fixed in repair as per exiting size & make all as specified and directed Engr- in -charge . Make of deep freezer: voltas /blue star
S&F in replacement Starting relay of refrigarator of any capacity fixed in repair complete all as specified and directed Engr- in -charge.
S&F Over load protector of refrigarator of any capacity fixed in repair all as specified and directed by Engr- in -charge.
S&F Thermostate switch for deep freezers of refrigerator of any capacity fixed in repair all as specified and directed by Engr- in -charge.
S&F Freezer door of refrigerator of any capacity fixed in repair all as specified and directed by Engr- in -charge
S&F in replacement defective cooling coil from refrigerator and supply and fixing new cooling coil as per existing size with gas refilling all as specified and directed by Engr- in -charge Make of regrigerator :Godrej/Voltas/LG/ Whirlpool .
S&F in replacement defective condensing coil from refrigerator and supply and fixing new condensing coil as per existing size with gas refilling all as specified and directed by Engr- in -charge. Make of regrigerator :Godrej/Voltas/LG/ Whirlpool .
S&F in replacement PVC flexible copper conductor sheathed cable of size 1.5 Sqmm 3 core, fixed in repair complete all as specified and directed by Engr- in -charge.
Removing of water coolers ,Desert cooler , Refrigerator from site after disconnecting the electric connection and water connection and painting with one coat of Red oxide primer and two coats of synthetic enamel paint by spray machine as per existing colour code after scratching the old paint complete and installing at site including electric and water connections all as specified and directed byEngr- in -charge.
S&F in replacement fan motor with fan for Double door Refrigerator all as specified and directed byEngr- in -charge. Make of refrigerator -Whirlpool / LG as per suitable size.
S&F in replacement PCB Circuit for Double door Refrigerator all as specified and directed byEngr- in -charge. Make of refrigerator -Whirlpool / LG / samsung as per suitable size.
S&F in replacement Bio Metal for Double door Refrigerator all as specified and directed byEngr- in -charge. Make of refrigerator -Whirlpool / LG / samsung as per suitable size.
S&F in replacement heater for Double door Refrigerator all as specified and directed byEngr- in -charge. Make of refrigerator -Whirlpool / LG as per suitable size.
S&F in replacement vegitable tray for Refrigerator as per suitable size all as specified and directed byEngr- in -charge.
S&F in replacement bulb for Refrigerator as per suitable size all as specified and directed by Engr- in -charge
S&F in replacement Racks Jali for Refrigerator as per suitable size all as specified and directed by Engr- in -charge.
S&F in replacement sliding glass for Refrigerator as per suitable sizeall as specified and directed by Engr- in -charge.
S&F in replacement bottle support for Refrigerator as per suitable size all as specified and directed byEngr- in -charge.
Notes :- (a) The contract sum shall be arrived at after deduction of amount of Schedule of Credit. (Rs. 83,939.50). (b) PERFORMANCE SECURITY :- (Refer condition 19 of IAFW-2249) The performance security for an amount equivalent to 3% (Three percent) of the accepted contract sum shall be delivered by the successful bidder immediately after the date of intimation letter of acceptance and all provisions shall be applicable as per condition 19 of IAFW 2249
INDERJIT SINGH
VIRAT CONSTRUCTIONS
M/s. Aggarwal Engineers
M/S BR ENTERPRISES
JAI DURGA CONSTRUCTION CO
M/S MS ENTERPRISES
M/S SALARIA BUILDERS
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .