Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1Accepted-Finance 1 SANSKRUTI APPARTMENT MURKUTE LANE NEW PANDIT COLONY NASHIK TAL DIST NASHIL | NASHIK | NASHIK | MAHARASHTRA | 422001 | L1 | Accepted-Finance L1 | |
| 2 | L2₹2+₹1 (100.0%)Rejected-Finance | L2 | Rejected-Finance L2 |
Tender Value
Refer Docs
Closing Date
24 Aug 2020, 2:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Executive Engineer, PW Division, Thane No 1
Executive Engineer, PW Division, Thane no 1 , PWD Compound, Station Road, Thane (West)- 400601
Construction of New Court Building (Basement plus Stilt to 10th Floor) in the Thane District Court. (Waterproofing Treatment to Raft and Retaining wall with HDPE Membrane sheet)
2020_PWR_603980_1
NIT_NO_07_FOR_2020_21
Open Tender
Civil Works
Item Rate
15 days
Thane
As Per Tender Documents
2 documents required · 2 mandatory
₹0
Exempted
8 May 2024
17 Aug 2020
26 Aug 2020
17 Aug 2020
24 Aug 2020
17 Aug 2020
60 days
Amount
Waterproofing Treatment to Raft - (HDPE Membrane): Supplying and installing of 1.2mm thick pre-applied HDPE membrane having puncture resistance of 800N as per ASTM E 154), tensile strength of 21 Mpa, and hydrostatic head resistance not less than 65m water head as per ASTM D 5385 & elongation of 500% as per ASTM D 412, peel adhesion to concrete of 880 N/m as per ASTM D 903, Lap peel adhesion > 400 N/m as per ASTM D1876. The pre-applied, fully bonded HDPE sheet membrane shall be loosely laid on PCC and gets bonded to the underneath of the poured concrete of base/ raft slab and confined retaining wall. The fully bonded HDPE sheet membrane shall consist of a high performance PE film, self adhesive polymer layer and unique particulate layer with pressure sensitive adhesive, which bonds fully to the poured concrete of base slab/confined retaining wall. The membrane shall have minimum of 75mm side laps and end laps which shall be sealed with double sided adhehive tape.,etc complete as per manufactures specification and instructions.
Waterproofing Treatment to Retaining Wall (Unconfined area): Providing and laying of 1.5 mm thick self adhesive, cold applied waterproofing membrane comprising of a self adhesive rubberized asphalt with cross laminated HDPE film topped with solar reflective film, confirming to the requirements of DIN EN 1849-1 for thickness with a puncture resistence of >220 N/cm as per ASTM D5147, puncture resistence of 200N as per ASTM E 154, providing ancillary products and finish complete including cleaning the surface, priming the surface with cold applied bituminous primer. The membrane should be sealed properly at joints & maintaining 75 mm overlap between the membrane selvedge & 100 mm overlap on the end joints of the membrane over the surface etc., complete as per manufacturers specification.Providing & laying high density polyethylene (HDPE) dimpled protection and drainage sheet; over the waterproofing membrane on the retaining walls. The protection and drainage sheet shall consist of dimpled HDPE sheet with fused on hydrophilic polypropylene geotextile; confirming to EN 13252, etc. complete as per manufacturer specifications.Termination: Supplying and applying aluminium strip flashing with fasteners at the top and sealing the joints with SmartCare Hybrid PU Sealant or approved equivalent.
Construction Joint Treatement:- Providing and laying of 1.5 mm thick self adhesive, cold applied waterproofing membrane comprising of a self adhesive rubberized asphalt with cross laminated HDPE film topped with solar reflective film, confirming to the requirements of DIN EN 1849-1 for thickness with a puncture resistence of >220 N/cm as per ASTM D5147, puncture resistence of 200N as per ASTM E 154, providing ancillary products and finish complete including cleaning the surface, priming the surface with cold applied bituminous primer. The membrane should be sealed properly at joints & maintaining 75 mm overlap between the membrane selvedge & 100 mm overlap on the end joints of the membrane over the surface etc., complete as per manufacturers specification.
Treatment for Pressure Release Pipes: Treatment of 50mm dia Pressure Release Pipes Periphery: Providing and sealing the periphery of the pipe with double sided tape and covering with PU Magnum, a thixotropic PU membrane. Note: Rate is including cost of pipe ( Length 1.5 Mtr GI Class B, its installation and grouting of pipe
Aquaseal Technologies
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .