Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.7 CrAccepted-AOC 303 GHS 888 SECTOR 20 PANCHKULA 134116 HARYANA | PANCHKULA | PANCHKULA | HARYANA | 134116 | ₹1.7 Cr | L1 | Accepted-AOC Lowest bidder |
| 2 | L2₹1.8 Cr+₹7.3 L (4.32%)Rejected-AOC | ₹1.8 Cr+₹7.3 L (4.32%) | L2 | Rejected-AOC Other than lowest |
| 3 | L3₹1.8 Cr+₹7.8 L (4.63%)Rejected-AOC 5037 5038 URBAN ESTATE PH 1 PATIALA 147002 PUNJAB | PATIALA | PATIALA | PUNJAB | 147002 | ₹1.8 Cr+₹7.8 L (4.63%) | L3 | Rejected-AOC Other than lowest |
| 4 | L4₹1.8 Cr+₹14.9 L (8.88%)Rejected-AOC ASTBAL MOHALLA BANASAR BAGH ROAD PATIALA GATE SANGRUR 148001 | SANGRUR | SANGRUR | PUNJAB | 148001 | ₹1.8 Cr+₹14.9 L (8.88%) | L4 | Rejected-AOC Other than lowest |
| 5 | L5₹1.9 Cr+₹24.0 L (14.3%)Rejected-AOC 3 1 4 GOPINATH BAZAR DELHI CANTT 110 010 | NEW DELHI | DELHI | 110010 | ₹1.9 Cr+₹24.0 L (14.3%) | L5 | Rejected-AOC Other than lowest |
Tender Value
₹2.2 Cr
EMD Value
₹3.0 L
Closing Date
4 May 2024, 6:00 pmClosed
CHIEF ENGINEER CHANDIGARH ZONE
CHIEF ENGINEER CHANDIGARH ZONE OLD AIRPORT CHOWK CHANDIGARH 160003
CA NO CE CHZ CHM T 15 2023 24 PROVN OF EXHAUST FANS AND GEYSERS IN JCOS OR MD ACCN AT SECTOR D AND E INCLUDING AUGMENTATION OF ELECTRIC SUP IN SECTOR D CHANDIMANDIR
2024_MES_640287_1
CECHZ/CHM/T-15/2023-24
Open Tender
Electrical and Maintenance Works
Item Rate
365 days
CHANDIMANDIR
Please refer Tender documents.
9 documents required · 9 mandatory
₹2,000
GE CHANDMANDIR
₹3.0 L
Yes
25 Jun 2024
22 Feb 2024
6 May 2024
22 Feb 2024
4 May 2024
27 Apr 2024
25 Feb 2024 - 5 Mar 2024
Amount
M&L Point wiring with PVC insulated PVC unsheathed electric FRLSH cable 1100V grade single core having multi stranded copper conductor of size 1.5 sqmm for phase & neutral in and new concealed PVC conduits medium grade including sheet steel modular sunken/flush boxes 1.2 mm thickness and suitable size of frame cover for mounting modular switch, socket and regulator fixed on surface in touch with wall and including 1.5 sqmm green PVC insulated unsheathed copper conductor as a earth wire connected to earth dolly by providing lugs for one light point/ fan point/ bell point controlled by one switch complete all as specified. Note:- Unit rate quoted includes cutting chases wall/ floor/ RCC and making good the disturbed surface to match with the original, nothing extra shall be paid on this account.
M&L Point wiring with PVC insulated PVC unsheathed electric FRLSH cable 1100V grade single core having multi stranded copper conductor of size 4.0 sqmm for phase & neutral in and new concealed PVC conduitsmedium grade including sheet steel modular sunken/flush boxes 1.2 mm thickness and suitable size of frame cover for mounting modular switch, socket and regulator fixed on surface in touch with wall and including 4.0 sqmm green PVC insulated unsheathed copper conductor as a earth wire connected to earth dolly by providing lugs for one light point/ fan point/ bell point controlled by one switch complete all as specified. Note:- Unit rate quoted includes cutting chases wall/ floor/ RCC and making good the disturbed surface to match with the original, nothing extra shall be paid on this account.
S&F modular switch one way 6 Amps one module 230 volts single pole all as specified.
S&F modular switch one way 16 Amps one module 230 volts single pole all as specified.
S&F modular socket outlet 2 in 1, 6/16 Amps two module 230 volts complete all as specified.
S&F sheet metal enclosures for MCB DB SPN 240 volts, 4 way single door fitted with 200 Amp rated bus bar complete all as specified.
S&F MCB SPN 32 Amp 230 volts having breaking capacity 10KA "B" type complete all as specified.
S&F MCB SP 6 to 32 Amp 230 volts having breaking capacity 10KA "B" type complete all as specified.
S & F Ceiling rose 6 Amps three terminals complete all as specified and directed.
M&L of Sub main wiring with two runs of single core PVC insulated and unsheathed multistranded, copper conductor (FRLSH) cable of size 4.0 sqmm LT, 1100V grade, down through and including adequate size of medium grade PVC non metallic conduit of 20mm/appropriate dia with accessories and fittings and one run of 4.0 sqmm single core multi stranded copper conductor cable (FRLSH) as earth continuity conductor. Two runs of cable one run of earth wire and one run of PVC non metallic conduit shall be measured as one run length, Cable required for connection to DBs shall deemed to be inclusive and shall not be measured separately. Earth wire shall run inside the conduit pipe complete all as specified.
Supply and fix exhaust fan made of sturdy engineering plastic complete with louvers shutter suitable for voltage 230V, 50 Hz, RPM minimum 900, 2 Nos bush bearing, Copper enameled wire winding, sweep 300mm including fixing with suitable size of MS Nuts/Bolts all as specified and directed.
S&F Exhaust fan , steel body AC single phase , 230 V of size 300 mm sweep with 900 RPM, pre lubricated double ball bearing, Copper enameled wire winding, blades, frame and louvers including grouting nuts, fastners and provision of flexible copper cable 3 core from ceiling rose to exhaust fan complete all as specified and directed. Note: Type of blade leaves - CRCA MS sheet, Nos of blade leaves - Four, Finish all exposed steel parts should be powder coated with minimum coating thickness of 50 microns, Exhaust fan motor: Totaly enclosed type capacitor start, induction type with 'E' class insulation,
Note for Ser No 11 & 12:- (i) Louvers shall be factory made from manufacturer of exhaust fan. (ii) "Pre dispatch" inspection shall be carried out at "Factory premises" by rep of accepting officer with in overall cost quoted. (iii) Item of making suitable hole and providing RCC Collar whereever required shall be measured and paid separately under relevant item.
S&F electric water storage heater (vertical type geysers) 25 ltrs , 2.0 KW, BEE 5 Star 230 volts AC single phase, including MS glass lined inner tank, glass coated heating element, high density PUF insulation, Anode rod protection, heavy duty fastner not less than 100mm with suitable size of nut & washer grouted in wall with complete mason work for proper mounting of geyser fastner bolt, such as safety valve ,NRV, thermostat, plug top etc as directed as per site requirement , making necessary inlet/outlet water connection and electric connection, testing on load for full satisfaction of Engineer-in-charge. Note:- (i) "Pre dispatch" inspection shall be carried out at "Factory premises" by rep of accepting officer with in overall cost quoted. (ii) Portable residual current device (16 Amps, 30mA) shall be provided with each Geysers in lieu of Plug Top. Cost of which is included in overall qoated cost by contractor. Any item left out for completion of job is deemed to be included in overall rates quoted by contractor.
Renewing tiles in patches, area n exc 5 sq.m. including removing old tiles, preparing beds in cement mortar 1:4 and laying or setting with cement slurry, jointing and pointing new glazed wall tiles to match the existing tiles complete all as specified.
S&F 15mm size PVC connection heavy duty 450 mm long with PTMT nuts complete all as specified.
S&F 15mm Tubes, 'medium grade' galvanised withand including all fittings and fixed complete to walls and ceilings or laid in floors complete all as specified and directed.
Cutting chases, pinning with cutter to facing of brick walls where reqd not exceeding 10 cm in girth including pointing in cement mortar 1:3 to cutting chases for concealed water tubing including making good cutting including existing finishes complete all as specified.
S&F 15 mm bore angle stop valve fancy type chromium plated high pressure with crutch or butterfly handle, screwed both end for iron pipe on wall complete as directed.
S&F 15mm bore bib cock long body fancy type chromium plated with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule complete all as directed.
Material and labour for cutting & screwing existing steel tubing 15mm bore size for alternations or additions required for connection with inlet pipe of geyser complete as directed at site.
M&L for making opening in brick wall bulit in cement mortar of any thickness including providing and fixing RCC pipe collar of 300 mm dia and making good the disturbed surfaces with cement mortar /concrete and finishing and matching the surfaces with existing finishes complete all as specified and directed.
Excavation in trenches in any type of soil not exceeding 1.50 metre wide and not exceeding 1.50 metre in depth; for laying of cable,poles etc. and getting out complete all as specified.
Returning filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25 cm thick each complete all as specified.
Removing excavated soil to a distance not exceeding 50 metre and depositing where directed at a level not exceeding 1.5 metre above the starting point complete all as specified.
Supplying and laying un-reinforced precast concrete cable cover ISI mark, class HV, type 1 flat , size 300mm x 180mm x 40mm complete all as directed.
M & L dry sand laid in trenches/ ducts for bedding and cushioning to cable, 8cm in depth before laying the cable and 15 cm after laying cable including spreading, levelling and consolidation complete all as specified and directed. Note- Consolidated/ punned sand shall be measured for payment purpose.
Supply and laying un-reinforced precast concrete cable cover ISI mark, class LV, type 1 flat , size 250 mm x 150 mm x 40 mm complete all as directed.
S & F in trenches, ducts or fixing along the poles or passing through pipes or laid under floors etc and testing XLPE insulated , screened PVC bedded, galvanised steel strip armoured, heavy duty HT power cables ISI marked with aluminium conductor, 11000 volts grade cross sectional area 240 sqmm 3 core, 11 KV earthed, complete all as specified.
All as per item No 28.00 here in before but size 95 sqmm 3 core.
S & F HT heat shrinkable type indoor end termination cable jointing kit with jointing material and accessories sutable for 11000 volt (Earthed) grade XLPE cable of size 240 Sqmm, 3 core complete all as specified: -
S & F HT heat shrinkable type indoor end termination cable jointing kit with jointing material and accessories sutable for 11000 volt (Earthed) grade XLPE cable of size 95 Sqmm, 3 core complete all as specified: -
S & F HT heat shrinkable type outdoor end termination cable jointing kit with jointing material and accessories sutable for 11000 volt (Earthed) grade XLPE cable of size 95 Sqmm, 3 core complete all as specified: -
Supply , installing, commissioning and testing transformer step down, Copper wounded, Outdoor type complete with standard fittings HT 11 KV/433 volts (at no load) 3 phase 4 wire, 50 Hz, capacity 750 KVA or next higher capacity, core type double copper wound, oil immersed. naturally cooled,. Oil naturally Air natural (ON AN) with external cooling tubes, delta connected on primary side (HV) and star connected on secondary side (LV) in accordance with vector group DYn-11 with neutral brought out on secondry side (LV side) and having tapping at +/- 7.5% in steps of 2.5% on HV side to be changed by means of hand operated off load tap changer gear. The maximum temp rise should not exceed 45 degree celsius in oil and 55 degree Celsius in HV/LV winding when measured by resistance method after continous full load run on an ambient temperature of 40 degree Celsies. The Transformer shall be IS- 1180 level 2 marked and shall comprises of the following :-
(a) Three Nos porceian bushing suitable for 11 KV on HV side complete with copper rods, nuts and washers (b) One cable box on LT side (Secondary side) consisting of four Nos porcelain bushing with copper rods, complete with nuts and washers with cable glands (c ) Oil conservator with filter type drain valve and oil level gauge (d) De- hydrating breather with first time fill of dehydrating agent (Silica Gel) (e) Explosive vent, thermometer pocket on tank cover .Oil level gauge , Oil drain filter valve, Lifting lugs, Oil filling hole with cap , plug with connection plate complete, Air release valve plug and four nos plain solid cast steel detachable rollers. (f) One no 100 mm dia dial type thermometer vapour pressure type , having range 0-120 Degree Celsius with metal guard having maximum perimeter temperature reading indicator with re- setting devices (g) Two earthing terminal on tank cover to facilitate fixing of 25x4 mm GI iron earth strip for earthing of body (h) Rating plate and terminal marking plate (j) Extra bushing for neutral, out side the cable box for providing independent set of earthing for neutral. (k) First filling of new transformer oil, IS- 335 filtered and tested.
NOTE: (i) Transformer shall be painted two coats of epoxy paint. (ii) Transformer shall be energy convervant for which necessary test certificate to be produced by Contractor from OEM of the transformer. (iii) Pre dispatch inspection of transformer shall be carried out by rep of Accepting Officer at manufacturer premises within overall cost quoted by Contractor. Nothing extra shal be payable on this account. (iv) After installation of the transformer, the same shall be tested and commissioned by SEI or rep of Accepting Officer and equipment/instruments required for testing shall be arranged by Contractor. Cost of the same shall also be deemed to be included in the item rates quoted by the contractor. (v) Drawing of transformer shall be approved by GE before placement of order. (vi) Minimum size of plinthfor transformer shall be 4Mx4Mx1M (LXBXH)
M & L PCC 1:2:4 type B-2 using 40 mm graded crushed stone aggregate as in transformer foundation including form work as required at site complete all as specified.
Excavation in post holes (or similar holes) each not exc 0.5 Cum, getting out, returning filling in and ramming earth or broken rubble mixed with earth around, in layers not exc 25cm, watering, and removing surplus soil to a distance not exc 50m and making good surface complete in any type of soil.
M&L for mild steel work as of posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire etc flat iron fillets(for securing wire mesh etc) including all necessary drilling, bolting or riveting etc and similar work confirming to Fe-290 Gde E-165 complete including painting with two coats of synthetic enamel paint of approved color over a coat of red oxide primer complete all as specified and directed.
Supply and fix of Galvanized Steel Chain Link fencing of mesh size 50mm x 50mm and dia of wire 4.00mm with and including line wires fixed to any type of standards, rails, straining bolts, etc. including provision of binding wire complete all as specified and directed
M&L for Mild steel bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips etc conforming to Fe.290.Gde-E-165 complete all as specified and directed.
M&L Pre-cast cement concrete block masonry type B1 1:2:4 (20mm graded aggregate) with solid blocks, exc. 10 cm in width and setting in cement mortar 1:6, complete
M&L for rendering 10mm thick cement plaster 1:6 on fair faces of brick work or concrete surfaces finished even and smooth (with out using extra cement) complete all as directed.
Supply , install, testing and commissioning of indoor type vacuum circuit breaker independent Panel as set of 3 panel Switchboard (1 incomer & 2 Outgoings) with posibility of future extension at one side,capacity 11 KV, 630 Amp, 3 Phase, 3 wire, 50 Hz, having a rupturing capacity of 350 MVA at 11 KV , 25 KA breaking capacity for 3 sec, Internal arc type tested for 25KA for 1 sec with AFLR clasification, totally enclosed with extended bus bar of 630 Amps for each phase, floor mounting, metal clad, Indoor extensible type , flush front, Horizontal isolation, Horizontal drawout type with Electrical and Mechanical interlock and automatic safety shutter gear including padlocking arrangement, isolation plugs, assembly of 3 vaccum interrupters (Should be VCB manufacturer's own make) , with each pole individually encapsulated by epoxy insulations and self - aligning finger type isolating contacts, truck having integral racking with necessary interlocks (for insertion and removing of VCB), manual and automatic motor charged independent closing/ tripping spring , trip free operating mechanism with closing and tripping push buttons and mechanical breaker, interconnected with OEM's own factory made (system house not allowed), Full voltage sleeve (PVC sleeve not accepted) insulated electrolytic copper bus bar of 630 Amps, including Power pack of 42 AH maintenance free battery back up system & all protection, indication, Operation, monitoring and control and accessories as per the specification for each VCB. Resin Cast Wound type CT Ratio : 200-100A/ 5-5 A, Core1: 5P20, 10 VA; Core 2: 0.5, 7.5 VA for incoming VCB and 100-50A/5-5A core 1-5P10, 10VA, core 2-0.5, 7.5 VA for - 02 No outgoing VCB. VT Ratio: 11KV/1.732/110V/1.732/110V/1.732, -Core 1: 1.0, 100VA for incoming and 02 No outgoing VCB-Core 2: 3P, 100VA IEC 61850 , HSR-PRP complient Numerical relay having protections of 50,51, 50N,51N, 67RYBN, 50LBB, 27, 59 etc for each VCB. Contd...
Taking down old defective UG LT cable of size 400 / 630 sqmm upto a length as specified by Engr-in-charge
Supply, laying, jointing and testing LT underground cable XLPE insulated , PVC sheathed, armoured heavy duty and 1100 volts grade with multistranded aluminium conductor of size 630 sqmm 3.5 core in trenches/ducts/through pipes/under culverts etc complete all as specified and as directed.
All as per item No 43.00 here in before but size 500 sqmm 3.5 core.
Supply, installation,commissioning and testing outdoor type floor mounting double door feeder pillar box , fabricated from 3.15 mm thick CRCA sheet and MC 75 for base channel, 04 nos legs 750 mm long made from 50 x 50 x 6 mm angle iron , duly powder coated, dust/water and weather proof , grouted in PCC 1:2:4 type B-1 foundation, suitable for 415 volts, 3 phase, 4 wire , 50 Hz complete of suitable size with and including the following:-
Earthing complete with galvanised steel earth plate electrode 60x60cmx6 mm thick burried directly in ground ( earth pit not less than 2.25 Mtr deep below ground level ) with top edge of the plate not less than 1.5 Mtr below normal ground level, connected to galvanised earth lead strip 32x6mm dia by means of bolts, nuts, check nuts and washers of GI or steel all as shown in electrical plate No. 5 of SSR Part-I 1991 connected to earthing test point panel all as specified or indicated and testing on completion as directed by the Engineer-in-Charge including necessary excavation & earth work in any type of soil, funnel, PCC chamber (1 : 3 : 6) type C1, CI pit cover and frame , charcol, salt including earth lead protected by 40 mm dia medium grade GI pipe and 20mm dia medium grade GI Pipe for watering complete. Note :- Earth strip 32 x 6 mm and GI 40 mm dia protecion pipe upto 7.5 mtr length will be deemed to include in the unit rate quoted.
M & L for cutting of road/ hardstanding for laying of cables in GI pipe of size 100 mm dia and making good the surface as per existing complete all as specified and as directed.
M & L GI tubes 100 mm bore light grade for cable protection on poles/walls/under road/culvert etc complete all as directed.
M & L for route indicator for HT cable disc type of size 150 mm dia CI, 8 mm thickness embossed with " MES HT CABLE" and fixed on angle iron 35 x 35 x 5 mm, 600 mm long as directed and painted in anti corrosive brown color paint incl PCC 1:2:4 type B-1 foundation block of size 300 x300 x 300 mm, duly fixed in ground complete all as specified and as directed.
M&L for shifting of LT panels from its exisiting position to a new position at a distance not more than 300 metres by disconnectinng all the electric connections and earthing strips, ungrouting the panel carefully and regrouting the same at its new location, making foundation work if necessary, making good the damaged surface, re-connecting all the electric connections and earthing strips as directed, dressing the LT cable for uninsulated or weakly insulated portion if any, complete all as specified and as directed. Note :- (a) PCC work for foundation of LT panel shall be measured and paid for separately under respective item of work. (b) Necessary frame work/ angle iron work for fixing of panel shall be deemed to be included in the quoted rate.
M & L PCC 1:2:4 type B-1 using 20 mm graded crushed stone aggregate for foundation of LT panels complete all as specified.
Supplying and laying synthetic Rubber insulated mats 2.5 mm thick for voltage 11 KV for electrical purpose as per IS 15652-2006, (superseding IS 5424) suitable for electrical shock safety of sizes 2m x 1m.
Rolled MS Framed work Fe 410-W (Gde E- 250) quality A as in doors or gates of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing complete
Total amount of Schedule 'A' /BOQ
M/s Kataria Construction Company
Sant Construction Co.
NARINDER KUMAR SONS
RAVINDRA BROTHERS
Raman Electric Trading Co
Sham Sunder Bansal
Vardhman Airport Solutions Private Limited
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.PDF
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .