Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Fee/PreQual/Technical/Finance PLOT NO 1235 JLPL SECTOR 82 SAS NAGAR MOHALI MOHALI PUNJAB 160055 | S A S NAGAR | PUNJAB | 160055 | Admitted-Fee/PreQual/Technical/Finance |
| 2 | Admitted-Fee/PreQual/Technical/Finance 13 SHIVPORA SHIVPORA SRINAGAR JAMMU KASHMIR 190004 | SRINAGAR | JAMMU AND KASHMIR | 190004 | Admitted-Fee/PreQual/Technical/Finance |
| 3 | Admitted-Fee/PreQual/Technical/Finance | Admitted-Fee/PreQual/Technical/Finance |
| 4 | Admitted-Fee/PreQual/Technical/Finance | Admitted-Fee/PreQual/Technical/Finance |
| 5 | Admitted-Fee/PreQual/Technical/Finance PLOT NO 78 NUNEDRESHI COLONY B BEMINA BYPASS SRINAGAR SRINAGAR JAMMU KASHMIR 190018 | SRINAGAR | JAMMU AND KASHMIR | 190018 | Admitted-Fee/PreQual/Technical/Finance |
Tender Value
₹69.7 L
EMD Value
₹1.4 L
Closing Date
5 Oct 2020, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Executive Engineer University of Kashmir
Construction Division
Supplying/ fixing/ Testing/ Commissioning of variable Refrigerant Flow System for Centre for Career Planning Council at Main Campus.
2020_UDJK_103465_1
F(E.Tend)(VRF-CCPC)(UCD)KU/ 07/20
Open Tender
Electronics Equipment
Item Rate
45 days
Supplying/ fixing/ Testing/ Commissioning of varia
As per NIT
4 documents required · 4 mandatory
₹1,600
Registrar University of Kashmir
₹1.4 L
7 Oct 2020
3 Sept 2020
7 Oct 2020
4 Sept 2020
5 Oct 2020
4 Sept 2020
120 days
Amount
VARIABLE REFRIGERANT FLOW/ VARIABLE REFRIGERANT VOLUME SYSTEM (with 2 years AMC for Whole System) Supply, Installation, Testing and Commissioning of Variable Refrigerant Flow/ Variable Refrigerant Volume modular type air- conditioning system suitable for Heating/Cooling by inverter driven capacity control compressor complete with indoor and outdoor units with individual controller , fittings etc. including full charging of eco frindly refrigerant gas complete, units shall be suitable to work on Cooling as well as Heating mode not less than range (-15°C to +46°C) . All individual/single outdoor units combined for making a module should have multiple compressors for better redundancy of the system. including additinal time delay system for entire Make : Daikin/Mitsubishi / Toshiba /O General/ Hitachi. AIR COOLED VRF/ VRV OUTDOOR UNITS Supply Instalaltion, testing and commissioning of Modular type outdoor units alongwith base frame as recommended by OEM equipped with highly efficient scroll / DC Twin Rotary compressors all with inverter type compressors special heat exchanger, low noise condenser fan, auto check function for connection error, auto address setting and capacity as mentioned below. The system should provide continuous heating during defrosting period
EVAPORATIVE VRF INDOOR UNITS Supply, Installation, Testing and Commissioning of modular type indoor units( fully imported) comprising of all accessories as per the specifications. The indoor units shall be suitable to work on Cooling as well as Heating mode.The job includes necessary civil works and supply & return air grills for concealed duct units alongwith allied items. The indoor units shall be suitable for operation on 220±6% volts,50Hz, 1/3 phase AC power supply and the indoor units shall be of following Cooling/ Heating capacities:
Hi-wall Units 2.08 TR
Cassette Units 1.65TR
Cassette Units 2.65 TR
Cassette Units 3.31 TR
Supply, Installation, Testing and Commissioning of Imported fittings (Y-joints)
Supply, Installation, Testing and Commissioning of Corded Remote for Indoor units
Supply, Installation, Testing and Commissioning of Main centralised controller units for minimum 64 indoo units.
REFRIGERANT PIPING Supply, Installation, Testing & Commissioning of high pressure copper refrigerant piping suitable for R 410a refrigerant of suitable size as required and duly insulated with 19mm/13mm thick closed cell elastomeric insulation in tubing form. External Refrigerant piping shall be laid on GI cable trays. Piping inside occupied spaces shall be supported using M S hangers duly painted with black enamel paint. Entire refrigerant piping work be carried out in accordance with the specifications. Piping shall be of following sizes :
6.4 mm dia with 13mm thick nitrile rubber insulation
9.53 mm dia with 13mm thick nitrile rubber insulation
12.7 mm dia with 13mm thick nitrile rubber insulation
15.8 mm dia with 13mm thick nitrile rubber insulation
19.1 mm dia with 13mm thick nitrile rubber insulation
22.2 mm dia with 19mm thick nitrile rubber insulation
25.4 mm dia with 19mm thick nitrile rubber insulation
28.6 mm dia with 19mm thick nitrile rubber insulation
31.8 mm dia with 19mm thick nitrile rubber insulation
34.9 mm dia with 19mm thick nitrile rubber insulation
41.3 mm dia with 19mm thick nitrile rubber insulation
PVC DRAIN PIPING Supply, installation, testing and commissioning of rigid PVC piping complete with fittings, supports as per specifications and duly insulated.
40 mm dia
32 mm dia
25 mm dia
CONTROL & TRANSMISSION WIRES
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable (Havells, Polycab, Skyline) in surface/ recessed medium class PVC conduit as required. 4 X 16 sq. mm + 2 X 6 sq. mm earth wire
2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire
2 X 4 sq. mm + 1 X 4 sq. mm earth wire
2 x 1.5 sq. mm
SNOW HOOD
Providing and fitting of snow/ bird protection hood in 22 gauge GI sheet with 1 inch wire mesh duly spray painted.
GI CABLE TRAY Supply and installation of lader type GI 'U' shaped channel cable tray of following sizes including bends and all fixing assoceries.
40 x 150 x 40 x 2 mm
40 x 300 x 40 x 2 mm
REFRIGERANT CHARGING
Additional Refrigerant eco friendly gas charging of entire VRV system
Leak testing with N2 pressure, holding, flashing etc complete in all pipe lining as required
Power Supply
Supply of ISI marked aluminium conductor XLPE insulated cable as per IS 7098, armoured, served, sheathed 1100 volts grade. Havells/CCI/ Paramount 35 sqmm 3 1/2 core
3½ X 70 sq. mm
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following including sand Cushioning and protactive brick layer (DSR 7.6.) Upto 35 sq. mm
Above 35 sq. mm and upto 95 sq. mm
Supplying and making end termination with brass compression glands of following sizes of 1.1. kv grade multicore aluminium conductor PVC insulated and PVC sheathed (DSR 9.1) 3½ X 35 sq. mm
3½ X 70 sq. mm
Supplying , fixing, testing and commissioning of fully outdoor double type electrical panel standing type powder painted with 200 Amp 36 kA 4p MCCB, 250Amp 4 p Aluminium busbar, including out going 25-32 A RCCBo's and ELCB's(300mA) for each out door unit and C--c-urve MCB's as per requirement and specification of OEMs. Make of switch gear: Legrand, ABB, siemens
Providing and fixing of MCB sub-panel box ( double door). MCB DP 's MCB's as required enclosed in MS box duly fitted on wall complete in all respects. Make: Legrand, ABB, siemens
Supply, Installation, Testing and Commissioning of 125kva 3 phase input 230-460V, Output 415V ± 1% buck booster type copper wound servo stabilizer Digital Microcontroller Servo Voltage Stabilizer fully out-door type of AE/Electric field/ Servo Volt, make with fresh dehydrated oil. With protection, complete in all respects. 1. High & low voltage Cut Off/ Time delay System 2. Cooling:- Oil Cooled 3. Over current/ short circuit protection 4. Auto variable transformer (Variac) 3 No's 5. Series Buck Boost Transformer 3 No's Specifications attached
Civil
Foundation Construction of Foundation for VRF outdoor unit (as required at site) of 600mm high and 300mm deep below ground level. Excavating/ steel bars/ Reinforced cement concrete work in well-staining, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse Sand (zone-III): 3 graded stone aggregate 20 mm nominal size). As required as per site, complete in all respects.
Construction of Foundation for and Servo Stabilzer (as required at site) of 600mm high and 300mm deep below ground level. Excavating/ steel bars/ Reinforced cement concrete work in well-staining, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse Sand (zone-III): 3 graded stone aggregate 20 mm nominal size). and top roofing in CGI on Servo Transformer As required as per site, complete in all respects.
False ceiling Providing/fixing/finishing of false ceiling works including all supporting arrangements, applying of Primer and Emulsion Paint coats as per site to Cover the Pipe lining and casette Units etc to give even shape , in all respects as required complete job.
CHAIN LINK FENCING Providing and Fixing Chain Link fencing with 9 gauge wire conforming to IS 2721 (2003) woven in a 50 mm (2 inch) mesh. Top and bottom selvage shall have twisted and barbed finish. Zinc‑coating weight shall be 570 grams/m2 2.0 ounces per square foot with following items (included) : Truss rods with turnbuckles or other equivalent provisions for adjustment. Top rail and bottom rails fitted with suitable expansion sleeves and means for securing rail to each gate, corner, and end posts. Top & Bottom tension wire as per ASTM A817 and ASTM F626, zinc‑coated, having minimum coating the same as the fence fabric. Item shall include accessories as necessary caps, rail and brace ends, wire ties or clips, braces and tension bands, tension bars,vertical supports, truss rods, and miscellaneous accessories conforming to ASTM F626.Rate including excavation, concreating(1:2:4 mix, Block 1.5ftx1.5ftX 2ft), back filling curing . Sample shall be got approved prior to execution of work.
Providing, fixing and Cladding with 3 mm thick matt finish Aluminium composite panel with all fixing arrangements to cover the pipe line/ finishing etc.
EARTHING
Providing of chemical earthing method (SMC-EAR) single electrode chemical compound based maintenance free earthing (laying) MS with copper cladded rod with minimum 10’ long and 16mm dia.HDPE manhole cover,) Brass bolts and nuts of required size,) Inspection joint of 150x50x5mm copper plate, ground improvement powder with resistance lowering compound/ equivalent chemical compound,copper conductor for providing connectivity up to the installation to be earthed and earth resistance should be less than 2 Ohms
precision systems
ACE COOLING SOLUTIONS
M/S STAR NEOTECH ENGINEERS
M/S MEDICAL ELABORATE CONCEPT PVT LTD
ALPHA TECH ENGINEERS
stage.html
html • 0.03 MB
finance_197313.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .