Loading…
Loading…
Tender Value
₹48.6 L
EMD Value
₹97,300
Closing Date
30 Jan 2026, 11:30 amClosed
No
No
Single Packet System
Normal Tender
No
Not Applicable
Lowest to Highest
60 days
Expenditure
Capital (Works)
Above/Below/Par
TENDER LKO
10 conditions · 8 needing a document upload
Please enter the percentage of local content in the material being offered. Please enter 0 for fully imported items, and 100 for fully indigenous items. The definition and calculation of local content shall be in accordance with the Make in India policy as incorporated in the tender conditions.
Upload filled & signed Annexure-C:Declaration form regarding site etc.(Format attached with Vol-I of tender document)
Upload filled & signed Annexure-D:"Declaration regarding constitution of firm".(Copy attached with Vol-I of tender document)
Upload filled and signed Annexure-E: List of plant and Machinery.(Copy attached with Vol-I of tender document)
Upload filled and signed Annexure-F: List of Engineers/Personnel (Copy attached with Vol-I of tender document).
Upload filled and signed Annexure-M:"Mandatory Certificate to be submitted by tenderer alongwith the tender documents.". (Copy attached with Vol-I of tender document).
Upload filled & signed Annexure-J:Real Time Gross Saving (RTGS)/National Electronic Fund Transfer(NEFT) Model Mandate Form (copy of format available in Vol-I of tender document)
Upload filled & signed Annexure-Q: Mandatory undertaking Regarding Employment/ Partnership of Retired Railway Employees.(copy of format available in Vol-I of tender document).
Upload filled & signed Annexure-AB: STATEMENT OF DEVIATIONS.(copy of format available in Vol-I of tender document)
Upload filled & signed Annexure K-3 & K-4: If tender submitted on behalf of Partnership Firm, relevant Annexures K-3 and K-4 as Declaration to be submitted by the tenderer alongwith tender document.
S&T work for Improvement of Alam Nagar Goods Shed and provision of connectivity of SSP to Power cabin at Alamnagar station of Lucknow Division.
287-Sig-C-II-LKO-T-03-25~NR
287-Sig-C-II-LKO-T-03-25
Open
Works - General
9 Months
Lucknow, Uttar Pradesh
₹0
₹97,300
30 Jan 2026
7 Jan 2026
16 Jan 2026
135 items across 1 schedule
| # | Description | Unit | Qty | Rate | Amount |
|---|---|---|---|---|---|
| — | — | — | 48,62,495.06 | ||
| — | 30.00 | — | — | ||
| Supply, Installation, Testing and Commissioning of Full HD Fixed Bullet type IP Color Camera along with128 GB or Higher SD Card, housing and mount and all accessories required for installation purposes as per RDSO Spec. No.RDSO/SPN/TC/65/2021, Rev6.0 or latest. Inspection: RDSO for supply portion. | — | — | — | 5,53,353.6 | |
| — | 2.00 | — | — | ||
| Supply and installation of outdoor P/T/Z dome IP Cameras with lens, housing, mount, power supply arrangements and enclosure as per RDSO specification no.RDSO /SPN /TC/65/ 2021 Rev. 6.0 or latest with latest amendment. Inspection: RDSO for supply portion. | — | — | — | 2,14,320.64 | |
| — | 1.00 | — | — | ||
| Supply, Installation, Testing & Commissioning of PC Workstation for Viewing cameras in multiscreen mode, Monitoring and System management and 4K UHD LED Monitor of 24-inch size including all required licensed software's (like OS, MS Office, Anti-virus with 03 year's subscription), multifunction device for documentation, accommodate PC workstation & monitor with all accessories, spike buster (minimum 5 nos. 6A points with fuse), 1KVA UPS, Mounting Rack and other required materials as per RDSO spec. No: RDSO/SPN/TC/65/2021 Revision 6.0 or latest. Inspection by Consignee. material should be procured from RDSO approved vender or OEM supporting certificate shall be provided that the material has been manufactured as per RDSO specification attached. Inspection: RDSO for supply portion. | — | — | — | 2,10,852.36 | |
| — | 1.00 | — | — | ||
| Supply of Server Hardware for Video Management and recording along with all accessories as per RDSO Specification No.RDSO/SPN/TC/65/2021 Version 6.0 or latest. Inspection: RDSO for supply portion. | — | — | — | 2,64,232.11 | |
| — | 32.00 | — | — | ||
| Supply, installation, testing, wiring & commissioning of Video Management & Recording software with license as per RDSO Specification No.RDSO/SPN/TC/65/2021 Version 6.0 or latest amendment. (Per camera license means video management (Viewing) at multiple locations such as station, RPF post & server room by same license). Inspection: RDSO for supply portion. | — | — | — | 2,44,352.32 | |
| — | 2.00 | — | — | ||
| Supply, configuration and installation of NVR 32 Channel (32 input and 32 output) NVR capacity with ethernet, HDMI and VGA output at up to 4K (3840x2160) resolution with HDD 4 SATA port to support up to 10TB HDD along with HDMI cable as per the requirement at site. Make: Matrix/CP Plus or similar. Inspection: Consignee for supply portion. | — | — | — | 97,433.76 | |
| — | 4.00 | — | — | ||
| Supply and installation of 8TB Hard Disk Drive Internal for CCTV for NVR (WD) (WD Surveillance purple) with 3-year Warranty. Inspection: Consignee for supply portion. | — | — | — | 69,269.32 | |
| — | 8.00 | — | — | ||
| Supply & installation of layer-2 switch (minimum 8 +2 manageable) with 08 Nos. 10/100/1000 Mbps ethernet port POE and 02 nos.1000 base X SM SFT port with optical modules complete with all accessories etc. as per RDSO specification no. RDSO/SPN/TC/65/2021 version-6 or latest. All material & accessories required for installation are to be provided by the contractor. Inspection: Consignee for supply portion. | — | — | — | 1,43,221.76 | |
| — | 16.00 | — | — | ||
| Supply of SFP Optical/Electrical 1 Gbps or100/1000 Mbps Electrical as required. Make: Cisco, E-optical or similar suitable for Neon. Inspection: Consignee. | — | — | — | 70,675.2 | |
| — | 16.00 | — | — | ||
| Installation, testing & commissioning of Single mode1G SFP module compatible to Layer 2 switch. | — | — | — | 2,490.4 | |
| — | 3.00 | — | — | ||
| Supply and installation of 9U, 19-inch rack for pole mount/ wall mount with Fan 230VAC 90CFM-02 Nos., AC distribution box (5 socket of 5A, Power on LED indicator, MCB)- 01 No., Shelf Cantilever 1U: 01 No. Cable Manager 1U:01 No. Inspection: Consignee for supply portion. | — | — | — | 36,888.36 | |
| — | 915.00 | — | — | ||
| Supply of STP CAT 6 Cable as per RDSO Specification No RDSO/SPN/TC/65/2021 Version 6.0 or latest. Inspection: Consignee for supply portion. | — | — | — | 40,443 | |
| — | 2.00 | — | — | ||
| Supply of 10/100 Mbps media converter 100 base FX-SM dual fiber, 230vACoperation with all accessories. As per RDSO/SPN/TC/103/2013-Rev-0 (or latest). Inspection: Consignee. | — | — | — | 13,881.58 | |
| — | 500.00 | — | — | ||
| Supply of power cable 3 core, 2.5 sq mm, multi strand (36/0.3 mm dia) cable as per IS 694:1990 reaffirmed 1995 or latest suitable for Railway electrification area, shall be of reputed make like Havells, Delton, LAPP, Finolex, or superior. Inspection: Consignee. | — | — | — | 49,215 | |
| — | 3000.00 | — | — | ||
| Laying of OFC/Power cable/CAT6 Cable on wall/ roof/ FOB/platform structure/ underground through (i) HDPE pipe /PVC conduit/GI pipe/ PVC Tray /casing caping with proper clamping arrangement of HDPE/ PVC Conduit /Cable or (ii) through underground DWC pipe and cutting of masonry wall /platform with a proper depth as per instruction of Railway site in charge and repairing masonry wall cement plastering after cable laying, All fixing , clamping, patching, jointing etc. material like couplers, connectors, OFC patch chords, Power cable Joint Box, masonry materials etc. are to be supplied by contractor with their own cost. | — | — | — | 36,840 | |
| — | 7.00 | — | — | ||
| Supply of 19" 6U Rack with all accessories like Electrical fitting, Fan tray, Patch Panel, cable manager, spike buster for housing IP storage unit. Inspection: Consignee for supply portion. | — | — | — | 29,288.63 | |
| — | 1.00 | — | — | ||
| Supply of 2 KVA Online UPS with 2 Hrs. backup, having SMF battery 4680 to be operated in input voltage of 160-260V, 50Hz AC, input over voltage protection 280VAC, input under voltage protection 155VAC with manual bypass provision, overload capacity of 125% of rated load under test for 60second, warranty of 2yrs for UPS and battery, indications shall be Mains-ON, Battery Charger ON, Battery Low, Inverter ON, Inverter Trip, Overload, DC-ON Minimum VAH 4680. Preferable Make: Hykon Hitachi, Numeric, Techser, Amaraja, V-Guard or similar. Inspection: Consignee. | — | — | — | 72,693.43 | |
| — | 2.00 | — | — | ||
| Supply, Installation, Testing & Commissioning of Professional Large Format LED Video Display Unit, 55" or larger, Full HD 1920 x 1080, Brightness: 350cd/m, contrast ratio1100:1, HDMI & DVI port, Including wall mount kit, HDMI Cable. as per clause no. 9.0 of RDSO/SPN/TC/65/2021 Rev. 6.0 or latest. Inspection: Consignee for supply portion. | — | — | — | 1,33,203.5 | |
| — | 1.00 | — | — | ||
| Supply of rack mountable (4+24) port manageable layer-3 core switch with 4 nos. 10G SFP+ ports and 24 Nos GE ports with all accessories as per RDSO specification no. RDSO/SPN/TC/65/2021 version-6 or latest. Inspection: Consignee. | — | — | — | 1,66,410.77 | |
| — | 1.00 | — | — | ||
| Supply, installation, testing, wiring & commissioning of Layer-2 managed Switch (24 ports 10/100/1000 BASE-Tports, 4 x 1G SFP+ ports) as per RDSO Specification No. RDSO/SPN/TC/65/2021 Version 6.0 or latest make HP/Cisco/Juniper or other reputed make with similar or better specs. Inspection: Consignee for supply portion. | — | — | — | 26,091.23 | |
| — | 4.00 | — | — | ||
| Supply of wireless access point/router dual band indoor managed/standalone access, built in antenna, two ports (1GE + 1FE), POE support. This includes all accessories make DIGISOL model DG-WM5307IAC or superior. Inspection: Consignee. | — | — | — | 57,538.4 | |
| — | 4.00 | — | — | ||
| Installation of wireless access point dual band indoor managed/standalone access, built in antenna, two ports (1GE + 1FE), POE support. This includes all accessories make DIGISOL model DG-WM5307IAC or superior. | — | — | — | 3,596.12 | |
| — | 1.00 | — | — | ||
| Supply of Crimping tool for CAT-6/RJ45 cable AMP, D-Link make or similar. Inspection: Consignee. | — | — | — | 1,110.23 | |
| — | 96.00 | — | — | ||
| Splicing of fibers OFC Cable and making Splice joint with contractor's own splicing machine and tools and consumables. | — | — | — | 20,739.84 | |
| — | 2.00 | — | — | ||
| Supply, installation of 24-Port jack patch panel fully loaded make: D-Link, AMP, DAX, Legrand, Molex or Digi link It Shall comply to TEC GR No. TEC/GR/SLC - 01/02.AUG 05 (TEC Standard Number: TEC 52010:2005) with latest amendments, Version. Inspection by Consignee for Supply portion. | — | — | — | 8,631.66 | |
| — | 915.00 | — | — | ||
| Supply of UTP CAT 6 Cable. Inspection: Consignee for supply portion. | — | — | — | 40,452.15 | |
| — | 12.00 | — | — | ||
| Supply and installation of I/O Box, White Jack Cat 6 Keystone UTP with Face Plate - Single (Keystone Jack, Square) & SMB. Make: D-Link or similar. Model: NKJC6WHI1B21 + NFP- 0WHI11. Inspection: Consignee for Supply portion. | — | — | — | 4,329.12 | |
| — | 100.00 | — | — | ||
| Supply of STP/UTP RJ 45 Connectors with STP Cable Make D-Link, AMP, DAX, Legrand, Molex or Digi link or similar. Inspection: Consignee | — | — | — | 1,192 | |
| — | 20.00 | — | — | ||
| Supply of OFC patch cord 10 Mtrs. Length as per RDSO/SPN/TC/69/2007 or latest. Inspection: Consignee. | — | — | — | 7,798 | |
| — | 30.00 | — | — | ||
| Supply and Installation of RJ-45 patch cord, 1/2/3/5 meter long, of reputed make like Molex or similar, with 02 no. of RJ-45 connectors for every patch cord. Inspection: Consignee | — | — | — | 4,504.2 | |
| — | 1000.00 | — | — | ||
| Supply of OFC single mode 6 fiber armored cables/STP CAT-6 cable as per site requirement and instructions given by site in charge. The CAT-6 cable should be compliant with TIA/EIA-568B or latest standards foe reputed make. Inspection: Consignee. | — | — | — | 32,200 | |
| — | 8.00 | — | — | ||
| Supply of 12 port loaded LIU rack mountable, LIU should be provided for terminating the optical fiber cables. It shall provide minimum bending radius and splice trays shall function as a splice cover for Pigtail Splicing. Cable glands shall be provided for secure anchoring of incoming cables. Rubber grommets shall be provided at the cable entry point for tight sealing. The splice tray should be made of ABS materials. LIU should be of reputed make. Make: D-Link/3M/ Digilink/Molex/ DAX or similar. Inspection: Consignee. | — | — | — | 30,783.52 | |
| — | 8.00 | — | — | ||
| Installation, Testing & Commissioning of rack mountable 12 port Loaded LIU. All the accessories and fixing materials required for this installation are to be supplied by contractor within the same cost. | — | — | — | 5,656 | |
| — | 15.00 | — | — | ||
| Supply, erection, testing, and commissioning of 5 meter high hot dip Galvanized octagonal pole with longitudinal seam weld throughout the length with bottom 130 mm across face, top 70 mm across face made of 3 mm thick high tensile plate and 200 mm X 200 mm X 12 mm base plate complete with two arm of 300 mm for fitting installation and 04 No. M20 (EN 8 Gr) X 700 mm long J type foundation bolt set complete with washer and smart pack junction box with suitable single pole MCB & terminal. | — | — | — | 1,63,841.25 | |
| — | 800.00 | — | — | ||
| Supply and fixing of PVC casing caping/conduit pipe 25mm x 25mm size for indoor wiring. This includes drawl of wires in the casing caping and termination of wire at end point. The work is to be executed as per the instruction of Railway Engineer. | — | — | — | 30,464 | |
| — | 1100.00 | — | — | ||
| Excavating and refilling of trench in Normal Soil to the level of ground with rammed earth as per drg. No.(NR/S&T/CON/1. 1/97-A) so as not to form a drain 0.3 Mtrs. Wide & 1 Mtr. Deep on both side of the station alongside the track to suit Railway electrified area. It shall conform to the safe distance as per signalling and cable plan. It also includes clearance of routes of trees & bushes. Lesser depth of the trench is to be paid proportionately. | — | — | — | 88,341 | |
| — | 100.00 | — | — | ||
| Cutting of the platform with tile/rock cutting machine or manually to 30cm depth and 12 cm width approximately (includes cutting of tiles neatly if provided) by removing slabs/tiles if any and laying of catches/pipe as supplied by railways and refilling the trench after laying of HDPE pipe and repairing the platforms as existing shape. Platform/paccka area only cutting with marble cutting machine. | — | — | — | 11,512 | |
| — | 8800.00 | — | — | ||
| Supply and laying of 2nd class bricks in the trench and laying as per drg. No. (NR/S&T/CON/1. 1/97-A) as per instructions of the site Engineer. | — | — | — | 74,712 | |
| — | 650.00 | — | — | ||
| HDD Boring & Trenchless of 120mm dia without HDPE pipe for laying of signalling / telecom /power cable under track/road/culvert etc., cable laying is covered separately. | — | — | — | 6,50,078 | |
| — | 1400.00 | — | — | ||
| Laying of signalling/Telecom/power cables of different sizes as per drg. No. NR/S&T/CON/1.1/97A and as per cable route plan approved by Railways and meggering of cable before and after its laying of all type of outdoor cables. | — | — | — | 12,782 | |
| — | 15.00 | — | — | ||
| Fabrication, supply and fixing of concrete cable marker as per RDSO drg. No. SDO/Cable Laying/020, dt.31.10.11. The marker shall be fixed at various places of cable route as per instruction of Eng. at site. | — | — | — | 21,336.75 | |
| — | 2.45 | — | — | ||
| Laying of HDPE duct in the trenches, including in HDD/Manual Boring and supply pulling of Nylon rope through is at different places as per direction of Engineer in charge/ site Engineer. It includes Supply of HDPE duct outer dia 40mm & inner dia 33mm as per TEC Gr No. G/CDS-08/02 Nov /2004 with latest amendment with end cap to be provided along with the drum at both ends. (RDSO specs No.RDSO/SPN/TC/45/2013 Rev.2.0). | — | — | — | 1,74,923.8 | |
| — | 5.00 | — | — | ||
| End plug for item no.42 above | — | — | — | 161.75 | |
| — | 5.00 | — | — | ||
| Plastic Coupler-Slip Fit/Push fit type for item no.42 above. | — | — | — | 417 | |
| — | 2.45 | — | — | ||
| Blowing/Drawing of OFC cable in the HDPE duct by mechanical system. | — | — | — | 27,575.78 | |
| — | 24.00 | — | — | ||
| Supply and fixing of G.I. pipe 75 mm dia, 3mm thick perforated at a distance of 20 CM or less of required length at culverts/ bridges/along the cuttings, suitably concreted at both ends as per drg. No. (NR/S&T/CON/1. 4/97) or at ASM office / other buildings suitably fixing it to the wall and at both ends. G.I. clamps of M.S. flats bolts and nut, to be supplied by the contractor. Inspection; Consignee for supply portion. | — | — | — | 20,568.96 | |
| — | 22.00 | — | — | ||
| All work of horizontal boring and trenchless cabling along with supply, transportation and insertion of double wall corrugated pipe -(ISI marked) conforming to RDSO Spec No. RDSO/SPN/204/2011 and the laying of cable in the boring under the track / road by using pipe of size 120 mm outer dia, 103.5 mm inner dia in which required number of cables to be crossed. The depth of horizontal boring should be minimum 1.0 m from rail flange/road level. (This item will be used for track crossing of running lines). Inspection: Consignee for supply portion. | — | — | — | 45,044.56 | |
| — | 1.00 | — | — | ||
| Casting, concreting and curing of foundation and erection of App. Cases half as per drg. No. (NR/S&T/CON/2.8/97). All materials such as cement, sand, aggregate and anchor bolts shall be supplied by the contractor. Contractor is required to execute all type of repair works of foundations if required during inserting the cable for termination. | — | — | — | 5,619.21 | |
| — | 1.00 | — | — | ||
| Painting of two coats of enamel paint over one coat of RED oxide primer on the single apparatus case after scrapping and cleaning of the surface wherever necessary. Primer and paints both Asian paints make are to be supplied by contractor. Location boxes inside and outside surface with aluminum paint. | — | — | — | 952.72 | |
| — | 72.00 | — | — | ||
| Testing & meggering of all types of outdoor cables after its laying and termination on both ends under supervision of Railway representative. This also includes preparation of test report for core to core and core to earth on prescribed proforma for each core of the cable separately after termination of cable. This also includes dressing & lacing of cable on both ends. Performa for testing & material for lacing to be supplied by the contractor. | — | — | — | 1,077.84 | |
| — | 2.00 | — | — | ||
| Supply & provison of straight through joints with the help of thermo shrink joints kit as per specification, drawings and stipulations of tender documents and as per approved cable route plan at various locations for 06 Quad/04 Quad cable. Jointing kit to be supplied as per RDSO spec. no. IRSTC 77/2012 (Rev-3) or latest. Inspection: RDSO for supply portion. | — | — | — | 14,820.86 | |
| — | 2.00 | — | — | ||
| Supply and installation of Fiber management system 19" with all installation materials, splicing, termination and testing of 2*24 fiber of the cable i.e. 48 fibers with all connectors material as per the instruction of the site engineer. Inspection: Consignee for supply portion. | — | — | — | 74,205.56 | |
| — | 2.00 | — | — | ||
| Supply and installation earth electrodes as per technical specification NR/S&T/CON/6.3/97. The item includes digging of pit in earth, 3 Mtrs. deep and fixing earth electrode pipe. Casting of Cement concrete enclosures as per drg. No. (NR/S&T/CON/6.4/97). The soil treatment shall be done as per std. practice. The item includes provision of earth lead wires and soldering of lead wires. The other end of the earth wire to be connected to cable sheath of power equipment, apparatus case, relay racks, other equipment's as per the instruction of Engr. at site & IRSEM. Complete materials such as earth electrodes of 50mm dia, cement, wiring material, soldering material to be supplied by the contractor. Inspection: Consignee for supply portion. | — | — | — | 7,264.48 | |
| — | 4.00 | — | — | ||
| Supply of OFC jumper (Patch card) 10mtr. long with FC/PC & SC or suitable connector at both ends as per IRS:TC-81/2000 with latest amendment. Inspection: Consignee for supply portion. | — | — | — | 2,545.04 | |
| — | 2.00 | — | — | ||
| Supply and Installation of 20 pair DP box made of cast Aluminium with in built locking system and water proof should have double outlet with leadig in brass nozzle.The main tag block plate is mounted on the inner aluminium chamber with brass terminal studded in back lite sheet. DP boxes & termination of cables as per specifications, drawing and stipulations of tender documents. This includes fixing of the same on 1" thick board of size as per directions of site engineer with ground nuts and bolts of suitable size and pipe fixed with clamps on pole/wall. All materials required for fixing & termination including salwood/hylum board and the hardware required for fixing will be supplied by contractor. Inspection: Consignee for supply portion. | — | — | — | 3,182.68 | |
| — | 450.00 | — | — | ||
| Provision of cable clamps on platform wall with fixing of angle bracket two no's size 40x40x6 of 300 mm length at a vertical distance of 400 mm or less as per available space in platform wall to carry required cables. Outer end of both angles to be welded/connected with 25x6 size MS flat. MS angle to be grouted in wall with concrete as per direction of consignee. | — | — | — | 4,65,390 | |
| — | 1.00 | — | — | ||
| Supply of 6 pin emergency socket as per IRS/TC/42/87(Amd.1) or latest. Inspection: Consignee. | — | — | — | 375.63 | |
| — | 1.00 | — | — | ||
| Supply of "Emergency socket Box of FRP material" as per RDSO specification no. RDSO / SPN / TC / 44/ 02 Ver.2.0, Amendment No.3 or latest. Inspection: Consignee. | — | — | — | 1,325.7 | |
| — | 1.00 | — | — | ||
| Fabrication and fixing of E.C. socket assembly complete and erection of fabricated assembly at location indicated in the route chart and as directed by engineer in charge. E/Socket assembly box with socket to be wielded on the metal body of apparatus case track side as per instruction of site engineer. Termination of derivation cable inside emergency socket box. Inspection: Consignee for supply portion. | — | — | — | 931.5 | |
| — | 2.00 | — | — | ||
| Supply & Installation of 9U Rack,9U*500W*450D, Front Glass Door with lock, 2 pairs of 19" Mounting Rails: Standard Accessories: -1Ucable manager, Roof Mounted Fan Unit/90 CFM/230V AC,6-way 5 Amp Power Distribution Unit, Mounting Hardware. Make:D-Link. Model: NWR- 9U- 5045-GR or similar. Inspection: Consignee for supply portion. | — | — | — | 24,043.26 | |
| — | 1.00 | — | — | ||
| Supply of 10/100 Mbps media converter 100 base FX-SM dual fiber, 230vACoperation with all accessories. As per RDSO/SPN/TC/103/2013-Rev-0 (or latest). Inspection by Consignee. | — | — | — | 6,940.79 | |
| — | 1.00 | — | — | ||
| Supply of portable Management Console for onsite programming. Model: DELL Inspiron 14 Laptop or similar (12th Generation Intel Core i7 or better, processor 4.4 Ghz or higher, RAM 8GB or higher, SSD 1TB, with inbuilt dual Graphic Card) or better as per specification". Inspection: Consignee. | — | — | — | 75,650.75 | |
| — | 10.00 | — | — | ||
| Supply of power Extension Board Wall mount with 5 nos. of 6-amp switch cum socket and ON/OFF switch along with indication of power ON and power cord of 3mtr length. | — | — | — | 4,229.4 | |
| — | 2.00 | — | — | ||
| Supply, installation & commissioning of maintenance free earth suitable kit as per RDSO specification RDSO/SPN/197/2008 and Drg No. SDO/RDSO/E&B/002 dated 19.09.2008 or latest with latest amendments. Earthing kit consisting of 1. Earthing electrode of 17 mm dia 3m long - 01 No. 2. MEEB (300mm X 25mm X 6mm) - 01 No. 3. SEEB (200mm X 25mm X 6mm) - 01no. 4. Earth Enhancing compound-30-35 Kg (minimum). 5. Multistand Single core PVC insulated copper cable 35 sq mm as per IS:694 (Duplicated) used to connect MEEB to main earth electrode Min. 10 mtrs or as per site requirement. This includes: - provision of earth connection from MEEB to S&T equipment i.e. cable sheath, apparatus case, BPAC, Axle counter, IPS, Data logger etc. with PVC earth wire of Size 16/25 Sq mm. through copper lugs of suitable size. PVC earth wire shall be supplied by Contractor. Note: At certain locations, it may not be possible to achieve earth resistance of less than 1.0 ohm with one earth electrode/ pit due to soil resistivity. In such cases, provision of loop earth consisting of more than one earth pit shall be done for interconnection of two earth pits copper tape of size 25 X 2 Sq. mm shall be provided by the contractor. The number of pits required shall be decided based on the resistance achieved for the earth pits already installed. The procedure mentioned above for one earth pit shall be repeated for other earth pits. The other earth so installed for the purpose of loop earthing arrangement shall be counted as separate earth. Supply by RDSO approved Firm. Inspection by RDSO for supply Portion. | — | — | — | 55,992.52 | |
| — | 1.00 | — | — | ||
| Supply and installation of Class B and Class C Surge Protection Device -indicative type - for protection of Intercom Exchange as per RDSO/SPN/TC/98/2011 Rev. 0 or latest Inspection: Consignee for supply portion. | — | — | — | 43,253.07 | |
| — | 2.00 | — | — | ||
| Supply of Self supported aluminum step ladder (conforming of ISI) 10 ft. Height (Telescopic). | — | — | — | 14,236.38 | |
| — | 1.00 | — | — | ||
| Supply of ESM furniture of Godrej or similar make consisting of the following: 1. Executive revolving bearing series low back floating chair with normal arms cushioned Chair : 1No. 2. Executive Table size 72x36x30" with 3 drawers one side, lockers cabinet on other side : 1No. 3. Visitor chair seat & back cushion with high density Foam with plastic PVC handle capsul type Flat pipe duly Painted black : 3Nos. 4. One Steel Almirah of size 72"x30"x17" with lock and handle arrangement for record keeping at station (Model: Godrej Store Well/Slimline 4S). Inspection: Consignee | — | — | — | 45,010.61 |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
HTML
nit.pdf
NIT
TenderDocument03-25.pdf
ATTACHMENT
TenderNotice03-25.pdf
ATTACHMENT
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .