| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹31.5 LAccepted-AOC | L1 | Accepted-AOC Due to lowest bidder | |
| 2 | L2₹40.8 L+₹9.3 L (29.5%)Rejected-Finance SHIV BARI ROAD NEAR KASUMAL HOTEL BIKANER 334003 RAJASTHAN | BIKANER | BIKANER | RAJASTHAN | 334003 | L2 | Rejected-Finance Due to not lowest bidder | |
| 3 | L3₹40.9 L+₹9.4 L (29.8%)Rejected-Finance BEHIND POWER HOUSE WARD NO 6 UDASAR BIKANER RAJASTHAN 334022 | BIKANER | RAJASTHAN | 334022 | L3 | Rejected-Finance Due to not lowest bidder | |
| 4 | L4₹44.4 L+₹12.9 L (41.1%)Rejected-Finance VILLAGE SATOJ TEHSIL SUNAM DISTT SANGRUR | SANGRUR | PUNJAB | 148001 | L4 | Rejected-Finance Due to not lowest bidder | |
| 5 | L5₹48.7 L+₹17.3 L (54.8%)Rejected-Finance | L5 | Rejected-Finance Due to not lowest bidder |
| Sl No | Description | Qty | Unit | M/S SIDHU CONSTRUCTION COMPANY L4 | M/s Rohit Construction Co. L2 | D DEV COMPANY L5 | BIDAWAT ENTERPRISES L3 | UNITECH CONSULTANCY AND TESTING SERVICES L1 |
|---|---|---|---|---|---|---|---|---|
| 1.00 | Excavation in trenches n. exc 1.5 m in depth and not exc 1.5 m wide for laying of GI tubes,UG cable/pole etc and getting out in soft/ dense soil complete all as specified. | 789 | Cum | 160 ₹1,26,240 | 120 ₹94,680 | 250 ₹1,97,250 | 107 ₹84,423 Lowest | 200 ₹1,57,800 |
| 2.00 | Returning filling in, including spreading, leveling, watering and well ramming in layers not exc 25cm thick complete all as specified. | 707 | Cum | 23 ₹16,261 | 20 ₹14,140 Lowest | 80 ₹56,560 | 21 ₹14,847 | 20 ₹14,140 Lowest |
| 3.00 | Removing excavated soil to a distance n.exc 50m and depositing where directed at a level n.exc 1.5 above the starting point complete all as specified and as directed by Engr-in-charge. | 82 | Cum | 23 ₹1,886 | 20 ₹1,640 Lowest | 90 ₹7,380 | 21 ₹1,722 | 30 ₹2,460 |
| 3.01 | Supplying, laying, jointing and testing Ductile iron pipe (ISI marked) class K-9 bore 150 mm confirming to IS : 8329, Flanged both ends centrifugally cast suitable for rubber tyton joints complete all as specified and as directed.
Note : (a) Earth work and DI specials/ fittings shall be measured and paid separetly.
(b) Cost of joints (push on tyton joints) including jointing materials shall deemed to be included in the quoted unit rate, nothing shall be paid extra on this account. | 220 | RM | 2,620 ₹5,76,400 | 2,200 ₹4,84,000 Lowest | 2,800 ₹6,16,000 | 2,657 ₹5,84,540 | 2,300 ₹5,06,000 |
| 4.00 | Supplying & fixing Ductile iron specials/ fittings of any size, any type like Bends, tapers, increasing, decreasing sockets, tees (Single and double branch), tail pieces and collars etc complete all as specified and as directed.
Note:- Make of DI fittings shall be same make as that of DI pipe or of make recommended by manufacturer of pipe. | 105 | Kg | 160 ₹16,800 | 200 ₹21,000 | 300 ₹31,500 | 217 ₹22,785 | 120 ₹12,600 Lowest |
| 5.00 | Supply, laying and jointing GI tubes, medium grade 100 mm dia in lengths with screwed and socket joints together with all galvanised steel fittings such as bends, elbows, tees, union, short pieces, connectors, check nuts, caps, plugs etc fixed complete laid in trenches/wall complete all as specified and directed by Engr-in-charge.
Note : Yellow arrow marking shall be done on each length throughout the section laid in trenches. | 1,145 | RM | 1,435 ₹16,43,075 | 1,350 ₹15,45,750 | 1,550 ₹17,74,750 | 1,297 ₹14,85,065 | 745 ₹8,53,025 Lowest |
| 6.00 | Supply, laying and jointing GI tubes, medium grade 80 mm dia in lengths with screwed and socket joints together with all galvanised steel fittings such as bends, elbows, tees, union, short pieces, connectors, check nuts, caps, plugs etc fixed complete laid in trenches/wall complete all as specified and directed by Engr-in-charge.
Note : Yellow arrow marking shall be done on each length throughout the section laid in trenches. | 1,100 | RM | 986 ₹10,84,600 | 950 ₹10,45,000 | 1,000 ₹11,00,000 | 907 ₹9,97,700 | 495 ₹5,44,500 Lowest |
| 7.00 | Supply, laying and jointing GI tubes, medium grade 50 mm dia in lengths with screwed and socket joints together with all galvanised steel fittings such as bends, elbows, tees, union, short pieces, connectors, check nuts, caps, plugs etcgalvanised,with all fitting and fixed complete to walls and ceilings or laid in floor all as specified and directed by Engr-in-charge.
Note : Yellow arrow marking shall be done on each length throughout the section laid in trenches. | 500 | RM | 640 ₹3,20,000 | 600 ₹3,00,000 | 600 ₹3,00,000 | 577 ₹2,88,500 | 385 ₹1,92,500 Lowest |
| 8.00 | Supply, laying and jointing GI tubes, medium grade 25 mm dia in lengths with screwed and socket joints together with all galvanised steel fittings such as bends, elbows, tees, union, short pieces, connectors, check nuts, caps, plugs etc fixed complete laid in trenches/wall complete all as specified and directed by Engr-in-charge. | 219 | RM | 320 ₹70,080 | 300 ₹65,700 | 400 ₹87,600 | 297 ₹65,043 | 205 ₹44,895 Lowest |
| 9.00 | Cutting existing pipeline 150/200 mm dia and inserting the tee for branch common connection for STP 1 & STP 2 complete all as specified and directed by Engr-in-charge.
Note : Outlet from STP 01 & from STP 02 and make common connction for outlet for GI 100 mm pipe for arboriculture work.
Note : All the accessories for cutting and insertion of tee labour element is included in the quoted rate.All DI fittings will be paid separetely under respective item. | 2 | Each | 2,500 ₹5,000 Lowest | 2,500 ₹5,000 Lowest | 15,000 ₹30,000 | 4,517 ₹9,034 | 5,000 ₹10,000 |
Tender Value
₹45.4 L
EMD Value
₹90,800
Closing Date
16 Aug 2025, 6:00 pmClosed
GE (N) BIKANER
GE (N) BIKANER
PROVN OF LAYING GI PIPE LINE STP-1 AND STP-2 INTERCONNECTION AND STP TO JCOS AND OR MD ACCN FOR ARBORICULTURE EXTENSION LINE OF CERTAIN UNITS, LIGHTING CONDUCTORS AT BLDG. NO T-381, 4XLIGHTING PROTECTION FOR LPG STORES AT CERTAIN BLDGS. AND 7X GEYSER
2025_MES_721361_1
GE (N) BKN-TOKEN/15/2025-26
Open Tender
Miscellaneous Works
Item Rate
270 days
GE (N) BIKANER
Please refer Tender documents.
6 documents required · 6 mandatory
₹500
GE (N) BIKANER
₹90,800
Yes
6 Oct 2025
18 Jul 2025
23 Aug 2025
18 Jul 2025
16 Aug 2025
4 Aug 2025
Amount
Excavation in trenches n. exc 1.5 m in depth and not exc 1.5 m wide for laying of GI tubes,UG cable/pole etc and getting out in soft/ dense soil complete all as specified.
Returning filling in, including spreading, leveling, watering and well ramming in layers not exc 25cm thick complete all as specified.
Removing excavated soil to a distance n.exc 50m and depositing where directed at a level n.exc 1.5 above the starting point complete all as specified and as directed by Engr-in-charge.
Supplying, laying, jointing and testing Ductile iron pipe (ISI marked) class K-9 bore 150 mm confirming to IS : 8329, Flanged both ends centrifugally cast suitable for rubber tyton joints complete all as specified and as directed. Note : (a) Earth work and DI specials/ fittings shall be measured and paid separetly. (b) Cost of joints (push on tyton joints) including jointing materials shall deemed to be included in the quoted unit rate, nothing shall be paid extra on this account.
Supplying & fixing Ductile iron specials/ fittings of any size, any type like Bends, tapers, increasing, decreasing sockets, tees (Single and double branch), tail pieces and collars etc complete all as specified and as directed. Note:- Make of DI fittings shall be same make as that of DI pipe or of make recommended by manufacturer of pipe.
Supply, laying and jointing GI tubes, medium grade 100 mm dia in lengths with screwed and socket joints together with all galvanised steel fittings such as bends, elbows, tees, union, short pieces, connectors, check nuts, caps, plugs etc fixed complete laid in trenches/wall complete all as specified and directed by Engr-in-charge. Note : Yellow arrow marking shall be done on each length throughout the section laid in trenches.
Supply, laying and jointing GI tubes, medium grade 80 mm dia in lengths with screwed and socket joints together with all galvanised steel fittings such as bends, elbows, tees, union, short pieces, connectors, check nuts, caps, plugs etc fixed complete laid in trenches/wall complete all as specified and directed by Engr-in-charge. Note : Yellow arrow marking shall be done on each length throughout the section laid in trenches.
Supply, laying and jointing GI tubes, medium grade 50 mm dia in lengths with screwed and socket joints together with all galvanised steel fittings such as bends, elbows, tees, union, short pieces, connectors, check nuts, caps, plugs etcgalvanised,with all fitting and fixed complete to walls and ceilings or laid in floor all as specified and directed by Engr-in-charge. Note : Yellow arrow marking shall be done on each length throughout the section laid in trenches.
Supply, laying and jointing GI tubes, medium grade 25 mm dia in lengths with screwed and socket joints together with all galvanised steel fittings such as bends, elbows, tees, union, short pieces, connectors, check nuts, caps, plugs etc fixed complete laid in trenches/wall complete all as specified and directed by Engr-in-charge.
Cutting existing pipeline 150/200 mm dia and inserting the tee for branch common connection for STP 1 & STP 2 complete all as specified and directed by Engr-in-charge. Note : Outlet from STP 01 & from STP 02 and make common connction for outlet for GI 100 mm pipe for arboriculture work. Note : All the accessories for cutting and insertion of tee labour element is included in the quoted rate.All DI fittings will be paid separetely under respective item.
Supply and fixing cast iron sluice valve PN 1.6 (long body ) ISI marked confirming to IS:14846-2000 suitable for 200 mm bore pipe, flanged ends, drilled, stainless steel spindle, CI gate with brass ring, iron wheel handle, complete including jointing material such as nuts, bolts, washers and rubber sheet etc complete all as specified and as directed.
Supply and fixing cast iron sluice valve PN 1.6 (long body ) ISI marked confirming to IS:14846-2000 suitable for 150 mm bore pipe, flanged ends, drilled, stainless steel spindle, CI gate with brass ring, iron wheel handle, complete including jointing material such as nuts, bolts, washers and rubber sheet etc complete all as specified and as directed.
Supply and fixing cast iron sluice valve PN 1.6 (long body ) ISI marked confirming to IS:14846-2000 suitable for 100 mm bore pipe, flanged ends, drilled, stainless steel spindle, CI gate with brass ring, iron wheel handle, complete including jointing material such as nuts, bolts, washers and rubber sheet etc complete all as specified and as directed.
Supply and fixing cast iron sluice valve PN 1.6 (long body ) ISI marked confirming to IS:14846-2000 suitable for 80 mm bore pipe, flanged ends, drilled, stainless steel spindle, CI gate with brass ring, iron wheel handle, complete including jointing material such as nuts, bolts, washers and rubber sheet etc complete all as specified and as directed.
S&F Gun metal gate valve 50mm bore with iron wheel head screwed both ends for iron pipes complete all as specified and directed
S&F Gun metal gate valve 25mm bore with iron wheel head screwed both ends for iron pipes complete all as specified and directed
. S&F Gun metal gate valve 20mm bore with iron wheel head screwed both ends for iron pipes complete all as specified and directed by Engr-in-charge.
Material and labour for Construction of brick masonary valve pit chamber size 150 x 150 x 150 cm (internal dimension) using sub class 'B' bricks complete including excavation & earth work, returning fillig and disposal of surplus soil to distance not exceeding 50m and deposited where directed, PCC 1:5:10 type E-2 using 40 mm graded stone aggregate in foundation, coping on top in PCC 1:2:4 type B-2 using 20 mm graded stone aggregate, brick work in cement mortar (1:4), inner plaster 12 mm thick in cm (1:4) finished even and smooth and pionting flush externally as the work proceeds in the same mortar, MS sheet cover 3.15mm thick mounted on angle iron frame of size 40 x 40 x 6mm with handle and locking arrangement duly painted with two coats of synthetic enamel paint over a coat of red oxide primer and embeded portion of MS work duly applying black bitumenous paint before embeded complete all as specified and as directed and shown on drawings
Material and labour for Construction of brick masonary valve pit chamber size 90 x 90 x 90 cm (internal dimension) using sub class 'B' bricks complete including excavation & earth work, returning fillig and disposal of surplus soil to distance not exceeding 50m and deposited where directed, PCC 1:4:8 type D-2 using 40 mm graded stone aggregate in foundation, coping on top in PCC 1:2:4 type B-2 using 20 mm graded stone aggregate, brick work in cement mortar (1:4), inner plaster 12 mm thick in cm (1:4) finished even and smooth and pionting flush externally as the work proceeds in the same mortar, MS sheet cover 3.15mm thick mounted on angle iron frame of size 40 x 40 x 6mm with handle and locking arrangement duly painted with two coats of synthetic enamel paint over a coat of red oxide primer and embeded portion of MS work duly applying black bitumenous paint before embeded complete all as specified and as directed and shown on drawings.
Cutting existing steel tubing for alterations or additions done in position without taking down for 100 to 40mm dia pipe (Each cut measured)
Supply & Fixed on walls and ceiling or laid in floor/walls and jointing GI tubes, 15 mm dia medium grade in lengths with screwed and socket joints together with all galvanised steel fittings such as bends, elbows, tees, union, short pieces, connectors, check nuts, caps, plugs etc fixed complete laid in wall complete all as specified and directed by Engr-in-charge . Note : GI pipe Outlet Connection from Sintex tank to Geyser inlet shall be concealed & from Geyser Outlet to tap point shall also be concealed.Cost of the same deemed to be inclusive in the quoted rate & nothing shall be paid extra on this account.
Supply and fixing Bib taps, cast copper alloy with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule and fixed
Supply & fixing Rotational molded polyethylene water storage tanks (cylinerical vertical with closed top)hoisted and fixed in position all as directed of cap 500 ltrs complete all as specified and directed.
Supply and Fixing 25mm ball brass valves, high pressure, with polythene float and flynut complete, screwed for iron pipe or brass ferrule all as specified and directed
. M & L for point wiring for for one 3 pin 15/16 Amps socket outlet controlled by one 3 pin socket outlet 5/16 amps,independent board with 4.0 sqmm single core PVC insulated and and sheathed multistranded copper conductor FRLSH cable 1100 Volt grade (ISI marked) including 4.0 Sqmm single core PVC insulated and sheathed multistranded copper conductor FRLSH cable 1100 Volt grade (ISI marked) as continuous earth wire in green colour to coomon earth dolly laid/drawn into and including non metalic PVC concealed conduit (medium duty, ISI marked not less than 25 mm dia) with all fittings such as tee, bends etc all as per IS terminated in & including new modular metal flush boxes of requisite module concealed in wall for mounting fittings like modular Switches, sockets, regulators etc with and including modular cover plates with frame of requisite modules all as specified and as directed: Notes:- (i) Cost of cutting/leaving forming chases for conduit, sinking for metal flush boxes and making good in CM 1:4 shall deemed to be included in quoted rate of this item. (ii) The quoted rates of this item shall deemed for include for modular metal flush boxes of requisite module and modular cover plate with frame of requisite module of colour as approved by GE
S&F in of sheet metal enclosures with socket, plug top complete with one single pole MCB -240 Volt- 20 AMP complete all as specified and as dircted by Engr-in-charge.
. S & F double door, sheet metal enclosure, powder coated for MCB DB TPN DB 4 way fitted with neutral link, earth bar , din rail and 200 amps rated bus bar 230 volt conforming to IS 13032-1991 complete all as specified and as directed by Engr-in-charge. Note : Blank space in DB (MCB) Slot in filled by blanking plate.
S & F double door, sheet metal enclosure, powder coated for MCB DB SPN 4 way fitted with neutral link, earth bar , din rail and 200 amps rated bus bar 230 volt conforming to IS 13032-1991 complete all as specified and as directed by Engr-in-charge. Note : Blank space in DB (MCB) Slot in filled by blanking plate.
S & F MCB SP, 5-32 Amps , 240 volts, breaking capacity 10KA complete all as specified and as dircted by Engr-in-charge.
S & F MCB SPN, 5-32 Amps, 240 volts, breaking capacity 10KA complete all as specified and as dircted by Engr-in-charge.
S & F MCB TPN 40-63 Amps, 240 volts, breaking capacity 10KA complete all as specified and as dircted by Engr-in-charge.
S & F water heater storage type 25 Ltr capacity, BEE 5 star and 8 bar pressure rated stainless steel (minimum wall thickness 2 mm) tank with feroglass coated inner container energy saving high density PUF insulation vertical ABS shock proof plastic body grouting of studs in wall in cement motar (1:3) nuts, washers, provision of two Nos PVC braided connection 450mm long heavy duty with brass nuts and two Nos brass chromium plated angular valve,thermostate,NRV ,TOP PLUG 16 AMP with valve flange suitable for 15mm bore pipe for water supply connection complete. Make : Havell/Bajaj /Crompton
M&L for submain wiring with 2 runs of 6.0 Sqmm (nominal area) size main cable & 1 runs of 6.0 Sqmm size earth continuity conductor single core PVC insulated unsheathed FRLSH multistranded copper conductor 1100 volt grade ISI marked cable drawn through & including suitable size of heavy duty non metalic rigid PVC concealed conduit ISI marked & conduit fittings/accessories, fixede concealed in wall/ceiling including dismantling & taking down old unserviceable sub main wiring complete all as specified & directed. Note :-(i) 02 runs of 6.0 Sqmm size main cable, 01 run of 6.0 Sqmm size earth continuity conductor cable & Conduit with accessories shall be measured as one run length for payment purpose. (ii) Cost of cutting/leaving forming chases for conduits and making good in CM 1:4 shall be included in quoted rate of this item.
M & L for sub main wiring with two single core 4.00 Sqmm PVC insulated unsheathed cable multi-stranded FRLS copper conductor drawn through and including PVC conduit pipe of suitable size not less than 25mm with all fittings and fixing accessories on roof, walls, ceiling etc. including 4.00 Sqmm PVC insulated unsheathed single core solid copper conductor earth wire complete including taking down old sub main wiring all as specified and directed (Note: (i) Two run of single core cable and one run earth wire, pvc Conduit will be measured as one length) (ii) Cost of cutting/leaving forming chases for conduits and making good in CM 1:4 shall be included in quoted rate of this item.
M&L for Earthing complete with galvanized steel earth plate electrode 60cm x60cm x 6mm thick buried directly in ground (earth pit not less than 2.25 meters deep below normal ground level) with top edge of plate not less than 1.5 meters below normal ground level connecting to the galvanised earth lead wire 4.0 mm dia by means of bolts, nuts check nuts and washers of galvanized iron and steel earth wire protected by provision of GI mediumgrade pipe 15mm bore including provision of concrete pit made with 40mm thick cover of RCC 1:2:4 reinforced with XPM (Weight not less than 4Kg/Sqm) and frame of angle iron 40x 40x6 mm and handle of 6mm dia MS bar made to shape, GI light grade 20mm bore pipe for watering perforated at bottom, 1.75meter long placed on top edge of earth plate, common salt & charcoal filling with fixing arrangement, funnel, wire mesh and earth work in hard/dense soil, returing filling in and removal of surplus soil to a distance not exceeding 50 meters all as per electrical plate No -5 of SSR 2009 Part-I and connecting to Lighting protection earth test points all as specifed and directed including testing on completion.
Supply & Laying & commissining of LT UG cable XLPE sheathed PVC insulated, screened PVC bedded, galvanised steel strip of wire armoured electric power cable heavy duty with stranded aluminium conductor 1100 volts grade, laid in tranches, in GI pipe, including brass cable glands, clamps etc of size 4 core x 10 Sqmm complete all as specifed and as directed. Note: Earthwork, sand cushioning, bricks, GI pipe, etc will be measured and pad under appropriate items.
Supplying and laying un-reinforced precast concrete cable cover, class LVP, Flat type, size 250 mm x 150mm x 40mm complete all as specified and as directed by Engr-in-Charge.
M&L for Sand Cushioning (dry) in trenches/ducts for protection of UG Cables (below, above and around the UG Cable laid in Trenches) of 23 cm spread thickness (8 cm in depth before laying the cable and 15 cm in depth after laying the cable) and consolidated (punned) upto 180 mm thickness, complete all as specified and as directed. Note : For the purpose of payment, punned thickness of sand cushioning only shall be measured and paid for.
Air termination, single pointed aluminium rod 12mm dia and 300mm long complete all as specified and directed by Engineer-in-charge.
M&L for PCC 1:3:6 type C2 using 40 mm graded aggregates in bed to 150 mm drain pipes including packing under and haunching against the sides of pipes after they are laid and tested for complete all as specified and as directed by Engineer-in-charge.
.Supply and fixing aluminium strip 25mm x 3mm complete with & including ceramic/backelite insulator base, saddles and fixing screws, nut, bolts and washers etc for fitting the strip on roof surface/wall surface as earth grid and and down conductor of lightning protection system of storage accn all as directed and specified.
M&L for test point terminal block made of gun metal or phoshorus bonze size 75x75x25mm, drilled and screwed including 4 Nos 8mm dia 25mm long hexagonal head screwes, fixed on wall surface, making connections of down earth conductors and earthing strips all as specifed and directed.
Supply and install Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required 32x6mm galvanised iron strip
.Supply and fix as vertical supports (for air terminations & for Al strip to avoid sagging in air) galvanized iron tubing light grade of size 40mm bore suitably grouted in PCC base as directed.
Earthing complete with galvanised steel pipe electrode, 32mm bore, medium grade, 2.5 metres length, buried directly and preferably vertically in ground with top edge not less than 1.25 metres below ground level connected with earthing lead of 4mm dia galvanised iron or steel wire all as shown in Plate No. 2 to the earthing test point all as specified and indicated including testing on completion
M/s Rohit Construction Co. (BID ID -3388095)
BIDAWAT ENTERPRISES (BID ID -3394280)
M/S SIDHU CONSTRUCTION COMPANY (BID ID -3384681)
D DEV COMPANY (BID ID -3395772)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .