Loading…
Loading…
| # | Company | Quoted % | Amount | Rank | Status |
|---|---|---|---|---|---|
| 1 | L1₹2.4 LAdmitted-Finance | L1 | Admitted-Finance | ||
| 2 | L2₹2.6 L+₹11,950.97 (4.91%)Admitted-Finance | L2 | Admitted-Finance | ||
| 3 | L3₹2.6 L+₹16,279.46 (6.68%)Admitted-Finance | L3 | Admitted-Finance | ||
| 4 | L4₹2.7 L+₹25,862.02 (10.6%)Admitted-Finance | L4 | Admitted-Finance | ||
| 5 | L4₹2.7 L+₹25,862.02 (10.6%)Admitted-Finance DEHRADUN | DEHRADUN | UTTARAKHAND | 248001 | L4 | Admitted-Finance |
Tender Value
₹2.7 L
EMD Value
₹5,440
Closing Date
6 Jan 2026, 2:00 pmClosed
Executive Engineer Irrigation Division No.II Jammu
Jammu
Const. of Bathrooms Including Tiles Floor for Zilladar Office R.S Pura and Precast Tile work in Front Building
2025_IFC_299373_3
Fresh e-NIT No. 25 of 12/2025-26
Open Tender
Civil Works - Canal
Percentage
40 days
Jammu
As per NIT
2 documents required · 2 mandatory
₹200
Executive Engineer Irrigation Division No.II Jammu
₹5,440
21 Jan 2026
29 Dec 2025
7 Jan 2026
29 Dec 2025
6 Jan 2026
29 Dec 2025
Earth work in excavation by manual means in trenches for foundations, drains, pipes, cables etc. (not exceeding 1.5 m in width) and for shafts, wells, cesspits and the like not exceeding 10 sqm on plan, including dressing of sides andramming of bottoms lift upto 1.5 m, including getting out excavated earth and disposal of surplus excavated earth 25 meter beyond 1 m from cutting edge
Providing and laying in position cement concrete of specified grade including curing butexcluding the cost of centring and shuttering. All work upto plinth level with:1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size)
Providing and laying in position cement concrete of specified grade including curing but excluding the cost of centring and shuttering. All work upto plinth level with: 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size)
Reinforced cement concrete work in beams, suspended floors, roofs having slope upto 15°, landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases upto five level including curing but excluding the cost of centring, shuttering, finishing and reinforcement with 1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20 mm nominal size)
Brick work with common burnt clay (non-modular) bricks of class designation 7.5 in foundation and plinth including curing in Cement mortar 1:6 ( 1 cement : 6 coarse sand)
Extra for brick work with common burnt clay bricks/cement concrete bricks in superstructure above plinth level upto floor five level
12mm Cement plaster of mix: 1 : 4 ( 1 cement : 4 fine sand).
15mm Cement plaster on the rough side of single or half brick wall of mix:1 : 4 ( 1 cement : 4 fine sand)
6 mm cement plaster to ceiling of mix 1 : 3 (1 cement : 3 fine sand)
Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS : 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shadesexcept burgundy, bottle green, black of any size as approved by Engineer- in-Charge, inskirting, risers of steps and dados over 12 mm thick bed of cement mortar 1:3 ( 1 cement :3 coarse sand) and jointing with grey cement slurry @ 3.3 kg per sqm, including pointingin white cement mixed with pigment of matching shade complete.
Providing and fixing 1st quality ceramic glazed floor tiles conforming toIS : 15622 (thickness to be specified by the manufacturer ) of approved make in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge in skirting, risers of steps and dados over 12 mm thick bed of cement Mortar 1:3 (1 cement: 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm including pointing in white cement mixed with pigment of matching shade complete.
Colour washing such as green blue or buff to give an even shade New work (two or more coats) with a basecoat of white washing with lime.
Finishing walls with water proofing cement paint of required shade on New work (two or more coats applied @ 3.84 kg/10sqm)
Centering and shuttering including strutting, propping etc. and removal of form work for Foundations, footings, bases for columns
Centering and shuttering including strutting, propping etc. and removal of form work for Suspended floors, roofs, landings, balconies and access platforms.
Edges of slabs and breaks in floors and walls Under 20 cm wide
Centering and shuttering including strutting, propping etc. and removal of form work for Lintel, beams, plinth beams, girders, bressumers and cantilevers.
Structural steel work in single section, fixed with or without connecting plate, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete.
Painting with synthetic enamel paint of approved brand and manufacture to give an even shade.Two or more coats on new work.
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level
Providing and fixing white vitreous china pedestal type water closet (European type) with seat and lid , 10 liter low level white vitreous china flushing cistern and CP flush bend with fittings and C.I. brackets, 40mm flush bend, overflow arrangement with specials of standard make and mosquito proof coupling of approved municipal design complete,including painting of fittings and brackets, cutting and making good the walls and floors wherever required: W.C. pan with ISI marked white solid plastic seat and lid.
Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete.
Providing and fixing 600x120x5mm glass shelf with edges round off supported on anodized aluminum angle frame with C.P. brass brackets and guard rail complete fixed with 40 mm long screws, rawl plugs, etc. complete
Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fitting arrangement of approved quality and colour: 450 mm long towel rail with total length of 495 mm, 78 mm wide and effective height of 88 mm, weighing not less than 170 gms.
Providing and fixing PTMT soap dish holder having length of 138mm, breadth 102mm, height of 75mm with concealed fitting arrangements, weighing not less than 106gms.
Providing and fixing wash basin with C.I. brackets, 15mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever required White Vitreous China Flat back wash basin size 550x400 mm with single 15 mm C.P. brass pillar tap.
Providing and fixing white vitreous china pedestal for wash basin completely recessed at the back for the reception of pipes and fittings.
Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C waste fittings complete
Providing and fixing 15 mm nominal bore C.P. brass long nose bib cock of approved quality conforming to IS standards and weighing not less than 810 gms.
Providing and fixing 15 mm nominal bore C.P. brass bib cock of approved quality conforming to IS : 8931
Providing and fixing 8 mm dia C.P. / S.S. Jet with flexible tube upto 1 metre long with S.S. triangular plate to European type W.C. of quality and make as approved by Engineer - in - charge.
Providing and fixing 15 mm nominal bore C.P. brass angle valve for basin mixer and geyser points of approved make conforming to IS : 8931
Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6mm angle iron and 3mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer.Using flats 30x6mm for diagonal braces and central cross piece.
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes,having thermal stability for hot and cold water supply, including all CPVC plain and brass threaded fittings. This includes jointing of pipes and fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer-in-charge 20mm nominal outer dia pipes.
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes,having thermal stability for hot and cold water supply, including all CPVC plain and brass threaded fittings. This includes jointing of pipes and fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer-in-charge 15mm nominal outer dia pipes.
Providing and placing on terrace (at all floor levels) polyethylene water storage tank ISI : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflowpipes but without fittings and the base support for tank
Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand :6 graded stone aggregate 20 mm nominal size) over 75mm bed of dry brick ballast 40mm nominal size well rammed and consolidated and grouted with fine sand including finishing the top smooth and curing complete
Providing and fixing on wall face un-plasticized Rigid PVC rain water pipes conforming to IS: 13592 Type A including jointing with seal ring conforming to IS: 5382 leaving 10 mm gap for thermal expansion.(110 mm diametre)
Providing and laying 60mm thick factory made cement concrete interlocking paver block of M-30 grade made by block making machine with strong vibratory compaction and of approved size and design/shape laid in required colour and pattern over and including 50mm thickcompacted bed of fine sand, filling the joints with coarse sand etc. all complete as per direction of Engineer-in-charge.
Carriage of Sand Bajri for an average distance of 25KM
Carriage of Bricks for an average distance of 20KM
Providing and fixing exhaust fan 250x250mm . (Crompton, Havels) direction of Engineer-in- charge.
Providing & fixing of 3no. Precast P.C.C Cylindrical section for temporary (Septic Tank) having diameter 900mm outer to outer & length of 1.2 mt.height, each having thickness not less than 35mm including cover at the top including excuation of bed of laying of brick bats of thickness 300mm & backfilling with available earth after placing with all connections. All the arrangements shall be done below the existing G.L as per site (Complete Job)
Providing & fixing of 5no. Electric points including all accessories i.e ( Condude pipes, electric wire, M.S electric Boxes, Switches, bulbs, etc in working conditions to be Complete Job ( Anchor, and Polycap and LNT) as direction of Engineer - in - charge
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.28 MB
BOQ_971202.xls
BOQ • 0.30 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .