| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹5.0 LAccepted-AOC 342 3 RAMASAMY NAGAR NARASOTHIPATTY SALEM 636 004 | SALEM | SALEM | TAMIL NADU | 636004 | ₹5.0 L Quoted ₹5.4 L | L1 | Accepted-AOC L1 |
| Sl No | Description | Qty | Unit | SRI VINAYAKA ENGINEERING SERVICES L1 |
|---|---|---|---|---|
| 1.00 | Charges for complete overhauling of 4000A L&T make, LT air circuit breaker, replacement of worn out mechanism spares if needed, checking operation in test and service position and satisfactory commissioning. (Version EDO/MDO) | 5 | Nos | 15,800 ₹79,000 |
| 2.00 | Charges for complete overhauling of 1000A – 4 nos. & 800A – 6 nos. L&T make, LT air circuit breaker, replacement of worn out mechanism spares if needed, checking operation in test and service position and satisfactory commissioning.
(Version – EDO/MDO) | 10 | Nos | 8,200 ₹82,000 |
| 3.00 | Material Charges :
Tripping/Closing coil 240V AC, 220VDC | 10 | Nos | 15,950 ₹1.6 L |
| 4.00 | Shunt release coil assembly 220 V, Operating range: 65% ≤ V ≤ 130% Vn | 6 | Nos | 6,550 ₹39,300 |
| 5.00 | Spring charge motor, 220V DC, 0.7Amps, 154W, 15000 rpm | 6 | Nos | 30,520 ₹1.8 L |
Tender Value
Refer Docs
EMD Value
₹4,500
Closing Date
15 Apr 2025, 2:00 pmClosed
CHIEF ENGINEER/MTPS-I
CHIEF ENGINEER MTPS-I METTUR DAM
MTPSI ES Circle EMI Complete servicing and replacement of worn out spares in 15 Nos of L and T make LT Air circuit breaker in UnitIII
2025_EB_535901_1
CE-MTPS-I-SE-ES-EM-I-OT 74-2024-25
Open Tender
Electrical Works
30 days
MTPS-I/METTURDAM
AS PER TENDER SPECIFICATION
4 documents required · 4 mandatory
₹0
₹4,500
Yes
12 Mar 2026
27 Mar 2025
16 Apr 2025
27 Mar 2025
15 Apr 2025
27 Mar 2025
27 Mar 2025 - 15 Apr 2025
Amount
Charges for complete overhauling of 4000A L&T make, LT air circuit breaker, replacement of worn out mechanism spares if needed, checking operation in test and service position and satisfactory commissioning. (Version EDO/MDO)
Charges for complete overhauling of 1000A – 4 nos. & 800A – 6 nos. L&T make, LT air circuit breaker, replacement of worn out mechanism spares if needed, checking operation in test and service position and satisfactory commissioning. (Version – EDO/MDO)
Material Charges : Tripping/Closing coil 240V AC, 220VDC
Shunt release coil assembly 220 V, Operating range: 65% ≤ V ≤ 130% Vn
Spring charge motor, 220V DC, 0.7Amps, 154W, 15000 rpm
stage.html