Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹25.0 LAccepted-AOC MULTICARE ENTERPRISES PRIVATE LIMITED COMMERCIAL COMPLEX VARDHMAN TOWER PREE T VIHAR G 63 GROUND FLOOR PLOT NO 16 17 18 110092 DELHI EAST DELHI N N 110092 | EAST DELHI | DELHI | 110092 | L1 | Accepted-AOC Accepted being lowest quoting | |
| 2 | L2₹27.5 L+₹1.6 L (6.12%)Rejected-AOC | L2 | Rejected-AOC Rejected being higher quoting | |
| 3 | L3₹27.8 L+₹1.9 L (7.29%)Rejected-AOC | L3 | Rejected-AOC Rejected being higher quoting | |
| 4 | L4₹29.7 L+₹3.9 L (14.9%)Rejected-AOC H NO 29 DEVILAL COLONY TCP 2 HISAR CANTT HARYANA | HISAR | HISAR | HARYANA | 125006 | L4 | Rejected-AOC Rejected being higher quoting | |
| 5 | Rejected-Technical 62 PINK ROSE COLONY KAIMARI ROAD 125001 | HISAR | HARYANA | 125001 | - | Rejected-Technical Rejected due to non receipt of EMD and DD physically being un enlisted firm |
Tender Value
₹24.2 L
EMD Value
₹48,400
Closing Date
12 Oct 2022, 6:00 pmClosed
GE Hisar
Garrison Engineer Hisar Military Station Hisar 125006
CA No GE(H)-41/2022-23 SPL REPAIR TO LT PANEL AND ALLIED WORKS OF CERTAIN OTM AND MD ACCN AREA AT HISAR MIL STN UNDER GE HISAR
2022_MES_551844_1
CA No GE(H)-41/2022-23
Open Tender
Miscellaneous Works
Item Rate
180 days
Hisar Mil Stn
As per Tender documents
6 documents required · 6 mandatory
₹500
GE Hisar
₹48,400
Yes
24 Nov 2022
14 Sept 2022
14 Oct 2022
14 Sept 2022
12 Oct 2022
29 Sept 2022
Amount
Excavation in trenches not exceeding 1.5 m wide and not exc. 1.5 m depth for laying cables, foundation for pole etc and getting out in soft/loose soil etc complete all as specified and as directed.
Removing excavated material to distance n. exc 50m and depositing where directed at a level n. exc 1.5m above the starting point etc complete all as specified and as directed. .
Returning filling in incl spreading leveling watering and well ramming in layers n. exc 25cm thick etc complete all as specified and as directed.
M&L for Sand cushioning 230mm thickness with dry sand (one layer of 80mm thickness before laying of cable and other layer of 150mm thickness after laying of cable) and punned down to 180mm after laying of cable in trenches for protection of cable complete all as directed. Note :- For the purpose of payment only punned thickness shall be measured.
Taking out the old unserviceable LT underground cable of any size, 1100 volts grade, XLPE insulated and PVC sheathed, armoured heavy duty with multistrand aluminium conductors from trenches/wall/floor/road/ culverts or pole etc including cable cover complete all as specified and directed . Note : Excavation and earth work, duct work, GI pipe for laying of cable and sand cushing etc are beyond the scope of this item and shall be measured & paid for separately under relevant items of BoQ.
Laying only old bricks retrieved from item Srl Item No. 5.00 (here-in-before) as cable covers in trenches etc complete all as specified and directed.
M&L for brick covering to underground electric cable using sub class ‘B’ bricks, laid dry, flat, perpendicular to the direction of cable etc complete all as specified and directed. .
Supply , laying , jointing, testing and commissioning of size 16 sqmm 2 core LT underground cable , 1100 volts grade, XLPE insulated and PVC sheathed, armoured heavy duty with multistrand aluminium conductors IS-7098, laid in trenches /fixed on wall /floor /road /culverts /pole or encased in GI pipe complete all as specified. Note : Sand cushioning, cable protection, GI protection pipe, clamps, jointing kits and excavation & earth work shall be measured & paid for separately.
Supply , laying , jointing, testing and commissioning of size 95 sqmm 3.5 core LT underground cable , 1100 volts grade, XLPE insulated and PVC sheathed, armoured heavy duty with multistrand aluminium conductors IS-7098, laid in trenches /fixed on wall /floor /road /culverts /pole or encased in GI pipe complete all as specified. Note : Sand cushioning, cable protection, GI protection pipe, clamps, jointing kits and excavation & earth work shall be measured & paid for separately.
Supply , laying , jointing, testing and commissioning of size 120 sqmm 3.5 core LT underground cable , 1100 volts grade, XLPE insulated and PVC sheathed, armoured heavy duty with multistrand aluminium conductors IS-7098, laid in trenches /fixed on wall /floor /road /culverts /pole or encased in GI pipe complete all as specified. Note : Sand cushioning, cable protection, GI protection pipe, clamps, jointing kits and excavation & earth work shall be measured & paid for separately.
M&L for earthing complete with galvanized steel earth plate electrode 60cmx60cmx6mm thick burried directly in ground (earth pit not less than 2.25 m deep below ground level) with top edge of plate not less than 1.5 m deep below normal ground level and connected to and including galvanized iron strip 32x6mm size as earthing lead by means of GI nuts, bolts, check nuts, washers thimbles, etc as shown in electrical plate No 3 of SSR Part-I and connection to main switch board/Test point/panel/equipment and testing on completion including excavation and earth work in any type of soil, returning filling in, and removal of surplus spoil to a distance not exc 50 metre, charcoal and salt in alternate layer 15 cm thick all around the earth plate electrode, MS funnel with wire mesh, GI pipe medium grade 20 mm bore for watering and 40 mm bore upto 7.50 metre long GI pipe light grade for earth wire protection fixed with poles/wall with two clamps, made from MS flat 25 mmx3mm, bolts, nuts and washers, PCC chamber (1:3:6) type C1, 40mm thick precast RCC cover 1:2:4 type B1 shall be provided on CI frame etc complete including taking down existing unserviceable earthing all as specified & as directed. Note :- PCC chamber shall be constructed at least 1.5m away from the earth electrode and pipe for watering shall be provided in slanting manners.
Supply, installation, commissioning and testing in replacement of MCCB 630 Amp ( fixed on existing panel) 415 volt, 4 pole, 50 KA breaking capacity with adjustable thermal and fixed magnetic type (Ics =100%Icu) complete with spreader terminals (legs) and with proper lugs and all fixing arrangement in existing panel complete all as specified and as directed.
Supply, installation, commissioning and testing in replacement of MCCB 250 Amp ( fixed on existing panel) 415 volt, 4 pole, 36 KA breaking capacity with adjustable thermal and fixed magnetic type (Ics =100%Icu) complete with spreader terminals (legs) and with proper lugs and all fixing arrangement in existing panel complete all as specified and as directed.
Supply, installation, commissioning and testing in replacement of MCCB 160 Amp ( fixed on existing panel) 415 volt, 4 pole, 36 KA breaking capacity with adjustable thermal and fixed magnetic type (Ics =100%Icu) complete with spreader terminals (legs) and with proper lugs and all fixing arrangement in existing panel complete all as specified and as directed.
Supply, installation, commissioning and testing in replacement of MCCB 63 Amp ( fixed on existing panel) 415 volt, 4 pole, 27 KA breaking capacity with adjustable thermal and fixed magnetic type (Ics =100%Icu) complete with spreader terminals (legs) and with proper lugs and all fixing arrangement in existing panel complete all as specified and as directed.
Supply, installation, commissioning and testing of LT Panel, LT (415 Volts, 50 Hz , 3-Phase, 4 wire supply), CPRI approved, factory assembled ,outdoor type, weather and vermin proof (Protection Class IP-54), made out of 40mm x 40mm x 5mm angle iron frame and 3.15mm thick (for external) and 2mm thick (for internal) MS Sheet CRCA sheet with both side (front and back) hinged, compartmental design with seperate door with provision of side cable relay suitable for 415 Volts, 3 Phase, 4 wire, 50 HZ supply system double door opening for external, rubber lining, locking arrangement, painted externally and internally with Nine tank pretreatment solution prior to a Powder coat of SIEMENS grey shade RAL 7032 (Berger/Nerolac) (first quality) over a coat of red oxide primer complete mounted on angle iron frame 40mmx40mmx6mm legs 45cm high above GL and 15cm embedded in ground with and including block of PCC 1:2:4 type B1 of size 30cmx30cmx30cm complete including and comprising of the following complete all as specified and directed including taking down existing u/s LT panel :-
(a) Bus bar chamber having 4 Nos air insulated Aluminium strip bus bars of rating not less than 1.5 times the rated capacity of the incoming MCCB as well as outgoings shall have aluminium TPN extension links (bus bar) of current carrying capacity not less than 1.5 times the rated capacity of individual MCCBs.
(c) Outgoing (i) MCCB 4 pole , LT 415 Volts, 50 Hz, AC, 250 Amps rating and 36 KA rupturing capacity, Adjustable thermal & adjustable magnetic release type specially fixed for outgoing supply with overload, short circuit and earth fault protection, adjustable type (Ics =100%Icu). - 02 Nos (ii) MCCB 4 pole , LT 415 Volts, 50 Hz, AC, 100 Amps rating and 36 KA rupturing capacity, adjustable thermal and fixed magnetic type ( Ics =100%Icu).- 01 No. (iii) MCCB 4 pole , LT 415 Volts, 50 Hz, AC, 63 Amps rating and 27 KA rupturing capacity, adjustable thermal and fixed magnetic type ( Ics =100%Icu).- 01 No. (iv) Fine wiring with single core copper conductor for instruments / indicating lamps - 01 Job
Note:- (i) All incoming /outgoing cables shall be connected through suitable size gland plate/glands and all spreader terminals of MCCBs should be connected with external links (bus bar). (ii) Taking out of all connections from old panels and connecting to new panel MCCB, bus bar by dressing and providing new thimbles included in quoted rates. (iii) Removing of all old debris of old plinth / panels from site deemed to be included in quoted rates.
Supply, installation, commissioning and testing of LT Panel, LT (415 Volts, 50 Hz , 3-Phase, 4 wire supply), CPRI approved, factory assembled ,outdoor type, weather and vermin proof (Protection Class IP-54), made out of 40mm x 40mm x 5mm angle iron frame and 3.15mm thick (for external) and 2mm thick (for internal) MS Sheet CRCA sheet with both side (front and back) hinged, compartmental design with seperate door with provision of side cable relay suitable for 415 Volts, 3 Phase, 4 wire, 50 HZ supply system double door opening for external, rubber lining, locking arrangement, painted externally and internally with Nine tank pretreatment solution prior to a Powder coat of SIEMENS grey shade RAL 7032 (Berger/Nerolac) (first quality) over a coat of red oxide primer complete mounted on angle iron frame 40mmx40mmx6mm legs 45cm high above GL and 15cm embedded in ground with and including block of PCC 1:2:4 type B1 of size 30cmx30cmx30cm complete including and comprising of the following complete all as specified and directed including taking down existing u/s LT panel :-
(a) Bus bar chamber having 4 Nos air insulated Aluminium strip bus bars of rating not less than 1.5 times the rated capacity of the incoming MCCB as well as outgoings shall have aluminium TPN extension links (bus bar) of current carrying capacity not less than 1.5 times the rated capacity of individual MCCBs.
(c) Outgoing (i) MCCB 4 pole , LT 415 Volts, 50 Hz, AC, 100 Amps rating and 36 KA rupturing capacity, adjustable thermal and fixed magnetic type ( Ics =100%Icu).- 02 Nos. (ii) MCCB 4 pole , LT 415 Volts, 50 Hz, AC, 63 Amps rating and 27 KA rupturing capacity, adjustable thermal and fixed magnetic type ( Ics =100%Icu).- 02 Nos. (iii) Fine wiring with single core copper conductor for instruments / indicating lamps - 01 Job
Note:- (i) All incoming /outgoing cables shall be connected through suitable size gland plate/glands and all spreader terminals of MCCBs should be connected with external links (bus bar). (ii) Taking out of all connections from old panels and connecting to new panel MCCB, bus bar by dressing and providing new thimbles included in quoted rates. (iii) Removing of all old debris of old plinth / panels from site deemed to be included in quoted rates.
Supply, installation, commissioning and testing of LT Panel, LT (415 Volts, 50 Hz , 3-Phase, 4 wire supply), CPRI approved, factory assembled ,outdoor type, weather and vermin proof (Protection Class IP-54), made out of 40mm x 40mm x 5mm angle iron frame and 3.15mm thick (for external) and 2mm thick (for internal) MS Sheet CRCA sheet with both side (front and back) hinged, compartmental design with seperate door with provision of side cable relay suitable for 415 Volts, 3 Phase, 4 wire, 50 HZ supply system double door opening for external, rubber lining, locking arrangement, painted externally and internally with Nine tank pretreatment solution prior to a Powder coat of SIEMENS grey shade RAL 7032 (Berger/Nerolac) (first quality) over a coat of red oxide primer complete mounted on angle iron frame 40mmx40mmx6mm legs 45cm high above GL and 15cm embedded in ground with and including block of PCC 1:2:4 type B1 of size 30cmx30cmx30cm complete including and comprising of the following complete all as specified and directed including taking down existing u/s LT panel :-
(a) Bus bar chamber having 4 Nos air insulated Aluminium strip bus bars of rating not less than 1.5 times the rated capacity of the incoming MCCB as well as outgoings shall have aluminium TPN extension links (bus bar) of current carrying capacity not less than 1.5 times the rated capacity of individual MCCBs.
(c) Outgoing (i) MCCB 4 pole , LT 415 Volts, 50 Hz, AC, 250 Amps rating and 36 KA rupturing capacity, Adjustable thermal & adjustable magnetic release type specially fixed for outgoing supply with overload, short circuit and earth fault protection, adjustable type (Ics =100%Icu). - 02 Nos (ii) MCCB 4 pole , LT 415 Volts, 50 Hz, AC, 200 Amps rating and 36 KA rupturing capacity, adjustable thermal and fixed magnetic type ( Ics =100%Icu).- 01 No. (iii) On Load Change over switch 400 Amps 4 Pole (Make Havells Cap part No IHCNFE0400 or equivalent of make mentioned here-in-after is List of makes).- 01 No. (iv) Fine wiring with single core copper conductor for instruments / indicating lamps - 01 Job
Note:- (i) All incoming /outgoing cables shall be connected through suitable size gland plate/glands and all spreader terminals of MCCBs should be connected with external links (bus bar). (ii) Taking out of all connections from old panels and connecting to new panel MCCB, bus bar by dressing and providing new thimbles included in quoted rates. (iii) Removing of all old debris of old plinth / panels from site deemed to be included in quoted rates.
Supply, installation, commissioning and testing of LT Panel, LT (415 Volts, 50 Hz , 3-Phase, 4 wire supply), CPRI approved, factory assembled ,outdoor type, weather and vermin proof (Protection Class IP-54), made out of 40mm x 40mm x 5mm angle iron frame and 3.15mm thick (for external) and 2mm thick (for internal) MS Sheet CRCA sheet with both side (front and back) hinged, compartmental design with seperate door with provision of side cable relay suitable for 415 Volts, 3 Phase, 4 wire, 50 HZ supply system double door opening for external, rubber lining, locking arrangement, painted externally and internally with Nine tank pretreatment solution prior to a Powder coat of SIEMENS grey shade RAL 7032 (Berger/Nerolac) (first quality) over a coat of red oxide primer complete mounted on angle iron frame 40mmx40mmx6mm legs 45cm high above GL and 15cm embedded in ground with and including block of PCC 1:2:4 type B1 of size 30cmx30cmx30cm complete including and comprising of the following complete all as specified and directed including taking down existing u/s LT panel :-
(a) Bus bar chamber having 4 Nos air insulated Aluminium strip bus bars of rating not less than 1.5 times the rated capacity of the incoming MCCB as well as outgoings shall have aluminium TPN extension links (bus bar) of current carrying capacity not less than 1.5 times the rated capacity of individual MCCBs.
(c) Outgoing (i) MCCB 4 pole , LT 415 Volts, 50 Hz, AC, 200 Amps rating and 36 KA rupturing capacity, Adjustable thermal & fixed magnetic type (Ics =100%Icu). - 02 Nos (ii) MCCB 4 pole , LT 415 Volts, 50 Hz, AC, 160 Amps rating and 36 KA rupturing capacity, adjustable thermal and fixed magnetic type ( Ics =100%Icu).- 01 No. (iii) Fine wiring with single core copper conductor for instruments / indicating lamps - 01 Job
Note:- (i) All incoming /outgoing cables shall be connected through suitable size gland plate/glands and all spreader terminals of MCCBs should be connected with external links (bus bar). (ii) Taking out of all connections from old panels and connecting to new panel MCCB, bus bar by dressing and providing new thimbles included in quoted rates. (iii) Removing of all old debris of old plinth / panels from site deemed to be included in quoted rates.
Supply, installation, commissioning and testing of LT Panel, LT (415 Volts, 50 Hz , 3-Phase, 4 wire supply), CPRI approved, factory assembled ,outdoor type, weather and vermin proof (Protection Class IP-54), made out of 40mm x 40mm x 5mm angle iron frame and 3.15mm thick (for external) and 2mm thick (for internal) MS Sheet CRCA sheet with both side (front and back) hinged, compartmental design with seperate door with provision of side cable relay suitable for 415 Volts, 3 Phase, 4 wire, 50 HZ supply system double door opening for external, rubber lining, locking arrangement, painted externally and internally with Nine tank pretreatment solution prior to a Powder coat of SIEMENS grey shade RAL 7032 (Berger/Nerolac) (first quality) over a coat of red oxide primer complete mounted on angle iron frame 40mmx40mmx6mm legs 45cm high above GL and 15cm embedded in ground with and including block of PCC 1:2:4 type B1 of size 30cmx30cmx30cm complete including and comprising of the following complete all as specified and directed including taking down existing u/s LT panel :-
(a) Bus bar chamber having 4 Nos air insulated Aluminium strip bus bars of rating not less than 1.5 times the rated capacity of the incoming MCCB as well as outgoings shall have aluminium TPN extension links (bus bar) of current carrying capacity not less than 1.5 times the rated capacity of individual MCCBs.
(c) Outgoing (i) MCCB 4 pole , LT 415 Volts, 50 Hz, AC, 100 Amps rating and 36 KA rupturing capacity, adjustable thermal and fixed magnetic type ( Ics =100%Icu).- 02 Nos. (ii) MCCB 4 pole , LT 415 Volts, 50 Hz, AC, 63 Amps rating and 27 KA rupturing capacity, adjustable thermal and fixed magnetic type ( Ics =100%Icu).- 01 Nos. (iii) Fine wiring with single core copper conductor for instruments / indicating lamps - 01 Job
Note:- (i) All incoming /outgoing cables shall be connected through suitable size gland plate/glands and all spreader terminals of MCCBs should be connected with external links (bus bar). (ii) Taking out of all connections from old panels and connecting to new panel MCCB, bus bar by dressing and providing new thimbles included in quoted rates. (iii) Removing of all old debris of old plinth / panels from site deemed to be included in quoted rates.
Supply, installation, commissioning and testing of LT Panel, LT (415 Volts, 50 Hz , 3-Phase, 4 wire supply), CPRI approved, factory assembled ,outdoor type, weather and vermin proof (Protection Class IP-54), made out of 40mm x 40mm x 5mm angle iron frame and 3.15mm thick (for external) and 2mm thick (for internal) MS Sheet CRCA sheet with both side (front and back) hinged, compartmental design with seperate door with provision of side cable relay suitable for 415 Volts, 3 Phase, 4 wire, 50 HZ supply system double door opening for external, rubber lining, locking arrangement, painted externally and internally with Nine tank pretreatment solution prior to a Powder coat of SIEMENS grey shade RAL 7032 (Berger/Nerolac) (first quality) over a coat of red oxide primer complete mounted on angle iron frame 40mmx40mmx6mm legs 45cm high above GL and 15cm embedded in ground with and including block of PCC 1:2:4 type B1 of size 30cmx30cmx30cm complete including and comprising of the following complete all as specified and directed including taking down existing u/s LT panel :-
(a) Bus bar chamber having 4 Nos air insulated Aluminium strip bus bars of rating not less than 1.5 times the rated capacity of the incoming MCCB as well as outgoings shall have aluminium TPN extension links (bus bar) of current carrying capacity not less than 1.5 times the rated capacity of individual MCCBs.
(c) Outgoing (i) MCCB 4 pole , LT 415 Volts, 50 Hz, AC, 63 Amps rating and 27 KA rupturing capacity .- 09 Nos. (ii) Fine wiring with single core copper conductor for instruments / indicating lamps - 01 Job
Note:- (i) All incoming /outgoing cables shall be connected through suitable size gland plate/glands and all spreader terminals of MCCBs should be connected with external links (bus bar). (ii) Taking out of all connections from old panels and connecting to new panel MCCB, bus bar by dressing and providing new thimbles included in quoted rates. (iii) Removing of all old debris of old plinth / panels from site deemed to be included in quoted rates.
Supply, installation, commissioning and testing of LT Panel, LT (415 Volts, 50 Hz , 3-Phase, 4 wire supply), CPRI approved, factory assembled ,outdoor type, weather and vermin proof (Protection Class IP-54), made out of 40mm x 40mm x 5mm angle iron frame and 3.15mm thick (for external) and 2mm thick (for internal) MS Sheet CRCA sheet with both side (front and back) hinged, compartmental design with seperate door with provision of side cable relay suitable for 415 Volts, 3 Phase, 4 wire, 50 HZ supply system double door opening for external, rubber lining, locking arrangement, painted externally and internally with Nine tank pretreatment solution prior to a Powder coat of SIEMENS grey shade RAL 7032 (Berger/Nerolac) (first quality) over a coat of red oxide primer complete mounted on angle iron frame 40mmx40mmx6mm legs 45cm high above GL and 15cm embedded in ground with and including block of PCC 1:2:4 type B1 of size 30cmx30cmx30cm complete including and comprising of the following complete all as specified and directed including taking down existing u/s LT panel :-
(a) Bus bar chamber having 4 Nos air insulated Aluminium strip bus bars of rating not less than 1.5 times the rated capacity of the incoming MCCB as well as outgoings shall have aluminium TPN extension links (bus bar) of current carrying capacity not less than 1.5 times the rated capacity of individual MCCBs.
(c) Outgoing (i) MCCB 4 pole , LT 415 Volts with Microprocessor release, 250 Amps rating and 36 KA rupturing capacity .- 06 Nos. (ii) Fine wiring with single core copper conductor for instruments / indicating lamps - 01 Job
Note:- (i) All incoming /outgoing cables shall be connected through suitable size gland plate/glands and all spreader terminals of MCCBs should be connected with external links (bus bar). (ii) Taking out of all connections from old panels and connecting to new panel MCCB, bus bar by dressing and providing new thimbles included in quoted rates. (iii) Removing of all old debris of old plinth / panels from site deemed to be included in quoted rates.
Supply, installation, commissioning and testing of LT Panel, LT (415 Volts, 50 Hz , 3-Phase, 4 wire supply), CPRI approved, factory assembled ,outdoor type, weather and vermin proof (Protection Class IP-54), made out of 40mm x 40mm x 5mm angle iron frame and 3.15mm thick (for external) and 2mm thick (for internal) MS Sheet CRCA sheet with both side (front and back) hinged, compartmental design with seperate door with provision of side cable relay suitable for 415 Volts, 3 Phase, 4 wire, 50 HZ supply system double door opening for external, rubber lining, locking arrangement, painted externally and internally with Nine tank pretreatment solution prior to a Powder coat of SIEMENS grey shade RAL 7032 (Berger/Nerolac) (first quality) over a coat of red oxide primer complete mounted on angle iron frame 40mmx40mmx6mm legs 45cm high above GL and 15cm embedded in ground with and including block of PCC 1:2:4 type B1 of size 30cmx30cmx30cm complete including and comprising of the following complete all as specified and directed including taking down existing u/s LT panel :-
(a) Bus bar chamber having 4 Nos air insulated Aluminium strip bus bars of rating not less than 1.5 times the rated capacity of the incoming MCCB as well as outgoings shall have aluminium TPN extension links (bus bar) of current carrying capacity not less than 1.5 times the rated capacity of individual MCCBs.
(c) Outgoing (i) MCCB 4 pole , LT 415 Volts, 50 Hz, AC, 100 Amps rating and 36 KA rupturing capacity, adjustable thermal and fixed magnetic type ( Ics =100%Icu).- 01 Nos. (ii) MCCB 4 pole , LT 415 Volts, 50 Hz, AC, 63 Amps rating and 27 KA rupturing capacity, adjustable thermal and fixed magnetic type ( Ics =100%Icu).- 03 Nos. (iii) Fine wiring with single core copper conductor for instruments / indicating lamps - 01 Job
Note:- (i) All incoming /outgoing cables shall be connected through suitable size gland plate/glands and all spreader terminals of MCCBs should be connected with external links (bus bar). (ii) Taking out of all connections from old panels and connecting to new panel MCCB, bus bar by dressing and providing new thimbles included in quoted rates. (iii) Removing of all old debris of old plinth / panels from site deemed to be included in quoted rates.
Supply, installation, commissioning and testing of LT Panel, LT (415 Volts, 50 Hz , 3-Phase, 4 wire supply), CPRI approved, factory assembled ,outdoor type, weather and vermin proof (Protection Class IP-54), made out of 40mm x 40mm x 5mm angle iron frame and 3.15mm thick (for external) and 2mm thick (for internal) MS Sheet CRCA sheet with both side (front and back) hinged, compartmental design with seperate door with provision of side cable relay suitable for 415 Volts, 3 Phase, 4 wire, 50 HZ supply system double door opening for external, rubber lining, locking arrangement, painted externally and internally with Nine tank pretreatment solution prior to a Powder coat of SIEMENS grey shade RAL 7032 (Berger/Nerolac) (first quality) over a coat of red oxide primer complete mounted on angle iron frame 40mmx40mmx6mm legs 45cm high above GL and 15cm embedded in ground with and including block of PCC 1:2:4 type B1 of size 30cmx30cmx30cm complete including and comprising of the following complete all as specified and directed including taking down existing u/s LT panel :-
(a) Bus bar chamber having 4 Nos air insulated Aluminium strip bus bars of rating not less than 1.5 times the rated capacity of the incoming MCCB as well as outgoings shall have aluminium TPN extension links (bus bar) of current carrying capacity not less than 1.5 times the rated capacity of individual MCCBs.
(c) Outgoing (i) MCCB 4 pole , LT 415 Volts, 50 Hz, AC, 63 Amps rating and 27 KA rupturing capacity, adjustable thermal and fixed magnetic type ( Ics =100%Icu).- 03 Nos. (ii) Fine wiring with single core copper conductor for instruments / indicating lamps - 01 Job
Note:- (i) All incoming /outgoing cables shall be connected through suitable size gland plate/glands and all spreader terminals of MCCBs should be connected with external links (bus bar). (ii) Taking out of all connections from old panels and connecting to new panel MCCB, bus bar by dressing and providing new thimbles included in quoted rates. (iii) Removing of all old debris of old plinth / panels from site deemed to be included in quoted rates.
Supply, installation, commissioning and testing of factory made, out door type, self standing, double door, front and back openable, APFC panel compartmental type with APFC relay 8 stage with heavy duty MPP capacitor bank 120 KVAR (5 KVAr - 03 No, 10 KVAr - 03 No, 25 KVAr - 01 No, 50 KVAr - 01 No with 7% detuned harmonics filter reactor) with thyrister control module and MCCB TP of 16 KA of 1.5 times of rating currect of capacitor suitable for each control and MCCB TPN 250 Amps 36 KA as incomer including control CT & control wiring complete having following assessories including control wiring with HR FRLS copper wire complete all as specified and directed including taking down existing u/s panel :-
Notes :- (i) Compact modular bolted design, removable side and back panels with option of top and bottom cable entry. (ii) Capacitor installed in removable assemblies for ease of operation and maintenance. (iii) Incoming of APFC panel of MCCB TPN 250 Amps, 36 KA breaking capacity with high electrolytic grade Aluminium bus bar of suitable rating. (iv) 120 KVAR (5 KVAr - 03 No, 10 KVAr - 03 No, 25 KVAr - 01 No, 50 KVAr - 01 No) with thyrister control module and MCCB TP of 16 KA of 1.5 times of rating current of each capacitor suitable for each control (each capacitor bank equipped with discharge resister) & 7% detuned harmonics filter reactor.
(v) High performance microprocessor based 3 Phase APFC relay 8 stage with Auto / Manual option. (vi) In built 3 Phase power analyzer, Ammeter, Voltmeter and PF meter (each have 01 No) (vii) Capacitor duty thyrister control modules with high thermal current carrying capacity and early make contacts to reduce inrush current for enhancing life of capacitors. (viii) Induced air system provided with axial flow fan / centrifugal fan. (ix) Bottom cable entry system available with front glass for viewing controller and analyzer from front.
Labour only for dismantling the serviceable MCCB / ACB from any existing panel to re-fixed the serviceable MCCB / ACB with all accessories in serviceable panel whose MCCB / ACB damaged / burnt complete all as specified and directed..
PRAJAPATI E and S ENGG CO
SAINI ELECTRIC STORE
M/s Devendera construction
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.PDF
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .