| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹20.4 LAccepted-AOC | L1 | Accepted-AOC LOWEST BIDDER | |
| 2 | L2₹21.9 L+₹1.0 L (4.95%)Rejected-Finance SAHEBPARA RAOD UPPER BAGDOGRA P O BAGDOGRA DISTRICT DARJEELING WEST BENGAL PIN 734014 | BAGDOGRA | DARJEELING | WEST BENGAL | 734014 | L2 | Rejected-Finance NOT LOWEST BIDDER | |
| 3 | L3₹22.0 L+₹1.1 L (5.39%)Rejected-Finance | L3 | Rejected-Finance NOT LOWEST BIDDER |
Tender Value
₹23 L
EMD Value
₹46,000
Closing Date
29 Jan 2020, 6:00 pmClosed
GE Bengdubi
PO-Bengdubi, Dist-Darjeeling, Pin 734424
REPAIR TO INTERNAL WIRING SYSTEM AT MC/MF DET, STN HQ, SBPO, TRANSIT CAMP, EPU PLANT AND GRTE UNDER GE BENGDUBI MIL STN
2019_MES_306536_2
GE/BENG/49 OF 2019-20
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
Bengdubi Military Station
MES Enlisted/ Un-enlisted contractor of Class E and above with category b(i)
9 documents required · 9 mandatory
₹500
GE Bengdubi
₹46,000
Yes
27 Feb 2020
10 Jan 2020
31 Jan 2020
10 Jan 2020
29 Jan 2020
17 Jan 2020
11 Jan 2020 - 14 Jan 2020
Amount
SCHEDULE 'A'
Taking down carefully copper/ aluminium point wiring (light, fan, buzzer, socket or power) complete including fixture and fittings such as switches, ceilling roses, pendants , regulators, sockets light fitting etc for taking credit removing from site and making good disturbed surface of walls, floors etc as per existing specification complete all as specified and directed.
Taking down carefully by unscrewing from boards/ outlet boxes, fittings and fixtures such as switches, sockets, ceiling roses, lamp holders, brackets, ceiling fittings, bulk head fittings, tube light fittings and regulators etc for reuse at site complete all as specified and directed. (Note : To be measured only when found serviceable in all respects complete for reuse)
Material and labour for point Wiring with 1.5 Sqmm (Nominal Area) FRLS PVC insulated unsheathed 1100 Volts Grade stranded Copper Conductor Cable (Red Colour Cable for Phase and Black Colour Cable for Neutral), laid in and including rigid non metallic PVC concealed conduit (medium grade) of suitable dia with Accessories including 1.50 Sqmm FRLS PVC insulated Stranded Copper Conductor Cable (Green Colour) as Earth Continuity Conductor and connected to Common Earth Dolly and CI/pressed steel terminal box with 3.00 mm thick laminated sheet cover fixed on Wall for one light point controlled by one switch including necesary Cutting chases in brick walls for concealed conduit wiring etc and making good, cutting not exc 10 cm girth complete all as specified and directed.
All items as per Ser No 3.00 above but for One fan point controlled by one switch
All items as per Ser No 3.00 above but for One 3 pin socket out let 5 Amps on independent board.
All items as per Ser No 3.00 above but for One 3 pin socket out let 5 Amps on same board.
All items as per Ser No 3.00 above but for One calling bell point controlled by one switch
All as per item No. 3.00 above but with 2.5 sqmm (Nominal area) cable with 2.5 Sqmm size copper earth continuity conductor for 15 Amp socket outlet on independent board complete all as specified and directed.
All as per item No. 3.00 above but with 4 sqmm (Nominal are ) cable with 4 Sqmm size copper earth continuity conductor for AC / Gyser socket outlet on independent board complete all as specified and directed.
Material and labour for point Wiring with 1.5 Sqmm (Nominal Area) FRLS PVC insulated unsheathed 1100 Volts Grade Stranded Copper Conductor Cable (Red Colour Cable for Phase and Black Colour Cable for Neutral), laid in and including PVC Casing and Capping with Accessories (size of Casing and Capping as required at Site) including 1.50 Sqmm FRLS PVC insulated Stranded Copper Conductor Cable (Green Colour) as Earth Continuity Conductor and connected to Common Earth Dolly and CI/pressed steel terminal box with 3.00 mm thick laminated sheet cover fixed on Wall for one light point controlled by one switch complete all as specified and directed.
All items as per Ser No 10.00 above but for One fan point controlled by one switch
All items as per Ser No 10.00 above but for One 3 pin socket out let 5 Amps on independent board.
All items as per Ser No 10.00 above but for One 3 pin socket out let 5 Amps on same board.
All items as per Ser No 10.00 above but for One calling bell point controlled by one switch.
All as per item No. 10.00 above but with 2.5 sqmm (Nominal area) cable with 2.5 Sqmm size copper earth continuity conductor for 15 Amp socket outlet on independent board complete all as specified and directed.
All as per item No. 10.00 above but with 4 sqmm ( Nominal area ) cable with 4 Sqmm size copper earth continuity conductor for AC / Gyser socket outlet on independent board complete all as specified and directed.
S&F switch piano flush button single pole 5 Amps 230 volt one way complete all as specified and directed.
Fixing only Switch piano any type (as retrived against item Ser No 2 here-in-before)
Supply and fixing switch socket outlet combination 5 pin 6 amp 2 in 1 flush type all as specified and as directed
Fixing only Switch Socket outlet Combination 5 Amp any type(as retrived against item Ser No 2 here-in-before)
Supply and fixing switch socket outlet combination multipurpose 3 pin 16 amp and one 3 pin 6 amp 5 in 1 controlled by one switch all as specified and as directed.
Fixing only Switch socket combination 5A/ 16A, 5 in 1flush type (as retrived against item Ser No 2 here-in-before)
Supply and fixing Lamp holder, PVC/Polycarbonate type with cord grip cap suitable for pendant fittings including 8 Watt LED bulb all as specified and directed.
Supply and fixing ceiling Rose, surface bakelite 65X35mm, three terminals complete all as specified and directed.
Fixing only Ceiling rose any type (as retrived against item Ser No 2 here-in-before)
Supply and fixing ceiling fan regulator electronic stepping type, SP 230 Volts, suitable for 1200 mm/1400 mm sweep ceiling fan including necessary electric connection complete all as specified and directed.
Supply and fixing including connection call bell AC 230 volts, single pole all as specified and directed.
Supply and fixing including connection of bell push button type 5 Amps all as specified and directed.
Supply and fixing of Single pole and neutral enclosure with a two pin and earth plug and socket complete with MCB of 20 to 32 amps, SPN all as specified and directed.
Supply and fixing of three pole and neutral enclosure with a three pin and earth plug and socket complete with TPN MCB of 32 amps all as specified and directed.
Supply and fixing of three pole and neutral enclosure with a three pin and earth plug and socket complete with TPN MCB of 63 amps all as specified and directed.
Supply and fixing LED tube light fitting 1 X 22 Watts (4 Ft) 240 V Wall mounted with 1X20 Watt single tube LED batten Ultra bright LED polycarbonate Tubelight with very high efficacy suited for installation in existing T8 tubelight with G13 lamp holders to give glare free light.complete with all accessories internally pre-wired and including connection all as specified and directed.
Supply and fixing LED BULK HEAD light fitting 10 watt ,230 V decorative wall mounting type with multicolour ABS housing with poly carbonate rings,and glass shade with lamp holder connector block , etc complele with all accessories per-wired and including connecting up with twin core twisted flexible copper conductor cable with suitable size complete all as specified and directed.
Supply and fixing LED light fitting 1x 9 W, 230 V, 2 feet with extruded aluminium housing with integrated LED driver complete with all accessories internally pre-wired and including connecting up with twin core twisted flexible copper conductor cable with suitable size complete all as specified and directed.
Supply and fixing for Recess mounting high lumen output LED light fittings of size 2 ft X 2 ft for metallic false ceiling type armstrong/US gypsum or similar ceiling mounting system with concealed or exposed 'T' section including 36 watt LED CDL light, all as specified and as directed.
Supply and fixing Street light fittings 1x 15W New generation energy saving & environmental friendly long life Versatile pressure die-cast aluminium IP66 roadway luminaire with high power LEDs as light source and electronic driver with 1.5 M long suitable size all as specified and directed.
Supply and fixing steet light bracket made out of 32 mm bore GI Light grade 1.00 M long to required shape as in bracket for steet light fittings fixed with two pair of MS flate iron clamp of size 50mm X 6 mm thickness of required shape with nuts, bolts and washers suitable for steel tubular pole including painting of mild steel flate iron surface with two coates of synthetic enamel paint over a coat of red oxide primer complete including taking down unserviceable one all as specified and directed.
Taking down MCB & DB from existing location with connection of any size and any type all as directed and specified.
Supply and fixing sheet metal enclosure for MCB, DBs, phosphatised, Powder coated, Tripple pole and neutral (TPN) 415 Volt double door, suitable for 4 way with dim rail earth and neutral bar all as specified and directed.
Supply and fixing sheet metal enclosure for DB's 12 Way when MCBs to be used single pole neutral 240 Volts with 200 Amp Bus Bar complete of following sizes all as specified and directed.
All items as per Ser No 40.00 above but 8 Way
All items as per Ser No 40.00 above but 4 Way
All items as per Ser No 40 above but 2 Way
Supply and fixing in proper position MCB TPN 63 AMP capacity, 415 Volts with 10 kA breaking capacity all as specified and as directed.
Supply and fixing MCB Single pole and neutral 240 Volt 06 to 32 amps capacity complete all as specified and directed.
Supply and fixing MCB Single pole 240 Volt 6 to 32 Amp capacity complete all as specified and directed.
Taking down carefully existing unserviceable tube light / LED light fitting of any watt from existing location to carry out the necessary repair like replacement of bipin holder, tubes etc and fixed to original location after made functional including necessary electric connections with 3 core flexible cable of size 23/0.0076 mm complete all as specified and directed. (Materials measured and paid seperately under relevent item of Sch 'A' /BoQ)
Supply ony Bipin holder for 18/36/40 W tube light complete all as specified and directed.
Supply only LED tube light fitting 1 X 22 Watts (4 Ft) 240 V Wall mounted suited for installation in existing T8 tubelight with G13 lamp holder complete all as specified and directed.
Supply only of LED single tube 1 X 20 Watts,(4 Ft) 240 V Ultra bright LED polycarbonate Tubelight with very high efficacy suited for installation in existing T8 tubelight with G13 lamp holders to give glare free light with all accessories complete all as specified and directed.
Supply only LED light fitting 1x 9 W, 230 V, 2 feet with extruded aluminium housing with integrated LED driver with all accessories complete all as specified and directed.
Supply only Recess mounting high lumen output LED light fittings of size 2 ft X 2 ft for metallic false ceiling type armstrong/US gypsum or similar ceiling mounting system with concealed or exposed 'T' section including 36 watt LED CDL light, all as specified and as directed.
Supply only surface mounting high lumen output LED light fittings of size 2 ft X 2 ft for metallic false ceiling type armstrong/US gypsum or similar ceiling mounting system with concealed or exposed 'T' section including 36 watt LED CDL light, all as specified and as directed.
Supply only LED Gate light 30 Watt New generation, post-top, energy saving, environmental friendly, long life aesthetically designed with symmetrical light distribution, spun aluminium landscape luminaire with high power LEDs as light source all as specified and as directed.
Supply only decorative wall mounting luminaries with end covers suitable for and 1X5 watt LED lamp all as specified and as directed.
Supply only Street light fittings 1x 15W New generation energy saving & environmental friendly long life Versatile pressure die-cast aluminium IP66 roadway luminaire with high power LEDs as light source and electronic driver with 1.5 M long suitable size all as specified and directed.
Supply and fixing in replacement Modular Switch 1 way 6 A, 1 module complete all as specified and directed.
Supply and fixing in replacement Modular Switch 1 way 16 A, 1 module complete all as specified and directed.
Supply and fixing in replacement Modular Socket 6 A, 2/3 pin combined 2 module complete all as specified and directed.
Supply and fixing in replacement Modular Socket 6 A/ 16 A, 2/3 pin combined 2 module complete all as specified and directed.
Supply and fixing in replacement Modular Regulator Step Type 120 watt, 2 module complete all as specified and directed.
Supply and fixing in replacement Modular Blank plate, 1 module complete all as specified and directed.
Supply and fixing in replacement Modular type White cover plate with frame 2 module complete all as specified and directed.
Supply and fixing in replacement Modular type White cover plate with frame 3 module complete all as specified and directed.
Supply and fixing in replacement Modular type White cover plate with frame 4 module complete all as specified and directed.
Supply and fixing in replacement Modular type White cover plate with frame 6 module complete all as specified and directed.
Supply and fixing in replacement Modular type Metal Flush box 2 module complete all as specified and directed.
Supply and fixing in replacement Modular type Metal Flush box 3 module complete all as specified and directed.
Supply and fixing in replacement Modular type Metal Flush box 4 module complete all as specified and directed.
Supply and fixing in replacement Modular type Metal Flush box 6 module complete all as specified and directed.
Supply and fixing in replacement MS Box in concealed of any type and any size complete all as specified and directed.
Supply and fixing in replacement PVC hylum sheet 3mm thik top cover of size 300 x 250 x 3 mm including refixing Switch, socket, regulator etc all as specified.
Supply and fixing in replacement PVC hylum sheet 3mm thik top cover of size 250 x 150 x 3 mm including refixing Switch, socket, regulator etc all as specified and directed.
Supply and fixing in replacement PVC hylum sheet 3mm thik top cover of size 100 x 100 x 3 mm including refixing Switch, socket,regulator etc all as specified and directed.
Supply and fixing in replacement PVC ractangular block for mounting switch/socket/MCB DB's with 3 mm thick plastic laminated sheet cover of size 250 x 200 x 50 mm deep all as specified and directed.
Supply and fixing in replacement PVC ractangular block for mounting switch/socket/MCB DB's with 3 mm thick plastic laminated sheet cover of size 200 x 150 x 50 mm deep all as specified and directed.
Supply and fixing in replacement PVC ractangular block for mounting switch/socket/MCB DB's with 3 mm thick plastic laminated sheet cover of size 150 x 100 x 50 mm deep all as specified and directed.
Supply and fixing in replacement flexible wire 2 core copper size 1.5 sqmm all as specified and directed.
Supply and fixing in replacement MCB Four pole, 415 volts, 40-63 Amps, breaking capacity 10KA Cat No 408700-02, make: Legrand or equivalent model of L&T, C&S, Indoasian
Supply and fixing in replacement MCB 'C' series Double pole 40 to 63 Amps, breaking capacity 10KA, Cat No 408637-39, make: Legrand or equivalent model of L&T, C&S, Indoasian
Supply and fixing in replacement MCB 'C' series Double pole 6 to 32 Amps, breaking capacity 10KA, Cat No 408628-36, make: Legrand or equivalent model of L&T, C&S, Indoasian
Supply and fixing in replacement MCB 'C' series single pole 6 to 32 Amps, breaking capacity 10KA, Cat No 408587-95, make: Legrand or equivalent model of L&T, C&S, Indoasian
Supply and fixing in Repair of 1x 36 watt U-type CFL lamp 240 volt 4 pin type including connection complete after taking down old one all as directed and specified.
Cutting Chases pinning in, for concealed conduit wiring and making goods of disturbed surface not exc 15 cm girth all as specified and directed.
Supply and fixing in replacement Ceiling Fan of Size 1200 mm sweep, 230Volts AC with connection from existing ceiling rose including taking down Old fan and deposting to MES store yard complete all as specified and diercted.
Supply and fixing in replacement Exhaust Fan of Size 250 mm sweep, 230Volts AC, PVC Body with connection from existing ceiling rose including taking down Old fan and deposting to MES store yard complete all as specified and diercted.
Supply and fixing in replacement Exhaust Fan of Size 300 mm sweep, 230Volts AC, Metal Body with connection from existing ceiling rose including taking down Old fan and deposting to MES store yard complete all as specified and diercted.
Supply and fixing in replacement Wall Fan of Size 400 mm sweep, 230Volts AC with connection from existing ceiling rose including taking down Old fan and deposting to MES store yard complete all as specified and diercted.
Supply and fixing in replacement Geyser 25 ltr capacity vertical type with BEE 5 star rating, having working pressure 8.0 Kg/cm² (max), electric water heater with ABS cover outer body 3mm EPAC (Engineered Polymer Anti Corrosion) coated inner tank to suit any kind of water, interchangeble colour panel, vitreous enamel coated incoloy heating element for long life, adjustable capilary thermostat for temparature regulation, multifunctional safety valve etc and fixing along the wall using suitable anchor bolts, nuts, washer complete all as specified and directed. (Note:- Old U/S Geyser shall be deposited to MES store for ledger and disposal action accordingly)
Taking down of wiring/Submain wiring upto size three phase 10.0 sqmm and refixing the same through new / existing casing-caping or conduit for distribution of balanced elect load at any indicated situation [ Note: PVC casing-capping or PVC conduit shall be measured and paid separately under repective item of Sch 'A' / BoQ]
Supply only PVC Casing-Caping of size 25mm
Supply only PVC Concduit of size 20mm
Supply only PVC Concduit of size 25mm
Taking out old U/S underground LT Service wire of any size, any position from trenches, floors and walls, all as specified and directed.
S&F 4 Sqmm 1100 Volts grade heavy duty cable PVC insulated multi stranded aluminium conductor of following size served with inner seathing of PVC tape and over all PVC seathed for service conection suspended by insulating hangers not more then 01 Mtr apart including 4mm dia suspension wire and twin core cable flate or circular including taking down complete as directed and specified.
All items as per Ser No 95.00 above but 6 Sqmm
All items as per Ser No 95.00 above but 10 Sqmm
Taking down of old Submain wiring upto 10 sqmm any type including batten/ conduit/ casing at any indicated situation
M & L for sub main wiring with 2 run of FRLS PVC insulated & unsheathed multistranded copper conductor of nominal cross sectional area 10.0 sqmm alongwith one run of FRLS PVC insulated & unsheathed multistranded copper conductor of nominal cross sectional area 10.0 sqmm as earth continuity conductor drawn through PVC Conduit complete all as directed by Engr-in-Charge (Note :- (a) Taking down of Old U/S Submain/PVC Conduit / casing- caping shall be included in same rate. (b) For concealed sub-main wiring cutting chases will be measured & paid separately. (c) All the incomming and outgoing cable should be connected throgh proper lugs & sockets as per site requirement)
All items as per Ser No 99.00 above but 6 Sqmm
All items as per Ser No 99.00 above but 4 Sqmm
All items as per Ser No 99.00 above but 2.5 Sqmm
Material & labour for advance Maintenance Free G.I. SAFE EARTHING Electrode with PIPE of not less than 50 mm outer dia( THICKNESS NOT LESS THAN -2.5MM) and two meter length, The electrode should be of galvinised (80 -100 micron) along with earth lead as Galvanised wire of size 4 mm . The GI Electrode shall be pre-filled with Cristaline Conductive Material (CCM) . The GI electrode shall be surrounded with 25 kg BackFill compound to provide maximum contact between the electrode and Back Fill Compound. Backfill compound should be eco-frendly and having RoHs certification . GI Electrode Shall be tested from CPRI.The earting pit should be cover with pcc(1:2:4 , B1) cover ,of 450 x 450 mm complete all as specified and directed (Make ASHLOK / INDELEC / JMV /TERCEL)
Excavation of trenches n.exc 1.5 metre wide and n.exc 1.5 metre depth and getting out in soft/loose soil complete all as specified and directed.
Returning, filling in, approved earth, including spreading, leveling, watering and well ramming in layers not exceeding 25cm in soft/loose soil complete all as specified and directed
Removing excavated surplus soil to a distance not exceeding 50 metre and depositing where directed at a level not exceeding 1.50metre above the starting point complete all as specified and directed.
Taking out old U/S underground LT cable of any size, any position from trenches, floors and walls, all as specified and directed.
Supply, fixing,Testing and commissioning XLPE insulated screened PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) with stranded aluminum conductor, 1100Volt grade with fixing acessories of 10 Sqmm, 2 Core complete all as specified and directed.
All as per item No. 107.00 above but for size of cable 16 sqmm, 2 core complete all as specified and directed.
M&L sand cushioning (dry) in trenches for protection of UG cables (below, above and around the cable laid in trenches) of 230mm spreding thickness and consolidated ( punned) upto 180mm thickness, complete all as specified and as directed.
Supply & Laying Sub-Class, old size, B Bricks, well burnt, laid breadth wise along the length of cable laid in trenches over sand cushion laid for UG cable protection complete all as specified and directed.
Taking down following unservisible items form existing board / location and supply and fixed same position incl electrical connection complete all as directed. (Note :- Material shal be measured and paid seperately under respective items of sch 'A' /BoQ)
Supply only Switch piano 5 amp flush type all as specified and directed.
Supply only Switch piano 15 amp flush type all as specified and directed.
Supply only Socket outlet 5 amp 5/6 pin all as specified and directed.
Supply only Socket outlet 15 amp 5/6 pin all as specified and directed.
Supply only Switch socket combination 6 Amp 6 pin flush type as specified and directed.
Supply and Fixing motor starter for 32 Amps 2 modules including modular MS flush box and cover plate 2 module complete all as directed. Make : legrand 673031 or equivelent
Supply only Switch socket combination 16 Amp 6 pin universal type as specified and directed.
Supply only Switch socket combination with box 6 Amp 6 pin flush type as specified and directed.
Supply only Switch socket combination with box 16 Amp 6 pin universal type as specified and directed.
Supply only Ceiling fan regulator electronic stepping type, SP 230 Volts, suitable for 1200 mm/1400 mm sweep ceiling fan
Supply only PVC angular holder polycarbonate as specified and directed.
Supply only Call bell ding dong type 230/240 volt AC as specified and directed.
Supply only Plug top of 15 amps 3 pin as specified and directed
Checking of ceiling fan 1200mm sweep at site when and where required as MES complaint slip on daily basis if reqired excepting sunday and holidays in existing position including Supply and fixing as replacement at site in position ceiling fan condensor 2.5 mfd all as spcified and directed.
All as per item No 126 above but ceiling fan 1400mm sweep when and where required as MES complaint slip on daily basis if reqired excepting sunday and holidays and ceiling fan condensor 2.5 mfd all as spcified and as directed
Taking down carefully ceiling fan any sweep and any make after disconnecting the electrical connection, dismantling the blades and removing fan incl blades to the work shop including cleaning and dismantling the fan into parts and segregation of unserviceable parts, replacement of unserviceable spares parts with new parts including necessary machining work and lubricating with approved grade of grease and necessary minor soldering work (if required) and re-assembling the fan complete and testing and refixing the fan in same position including all electrical connection and material and labour for replacement of two nos split pins, one connection block and one rubber reel all as specified and as directed. Note : i) Rewinding work of armature (if any) shall be measured and paid separately ii) New spare parts required for replacing old burn out parts other than connector, split pins, connection block and rubber reel shall be measured and paid separately as Supply only under item No130 to133 here-in-after. iii) Labour cost for replacing spare parts are deemed to be inclusive in the quoted rate of item No. 128 above.
Material and labour for taking out and removing burnt copper winding, cleaning the armature, rewinding the fan armature for 1200mm sweep fan with new super enamelled copper wire of existing gauge including supply and fixing necessary insulating materials etc and varnishing with approved grade of insulation varnish and heating up and testing all as specified and as directed.
All as pr item No.129.00 above but for 1400mm sweep ceiling fan all as specified and as directed.
Supply only bearing No.6201/6202 for Ceiling Fan
Supply only fan condensor 2.5 mfd
Supply only gun metal bush of any size
Comprehensive repair/maintenance of storage type electric water heater (Geyser ) vertical or horizontal type of capacity 50 Ltrs comprising of the following :- (a) Inspection, taking down , opening or dismantling, de-scaling,brushing and thoroughly cleaning the storage tank up to the satisfaction of the Engineer-in-charge. (b) checking of all stop cock, pressure release valves, fusible plugs for its serviceability etc. in situ to ensure free movement of the parts including supply and replacing the washers/gasket nut etc. (c) Checking and rectify earth continuity of the Electrical circuits of the Geysers and power point. (d) Checking,and re-fixing thermostat and re-adjust. (e) De-scaling the immersion type heating element and siphon assembly with diluted Hydro chloric acid or clear pedette solution. (f) Checking of indicator lamp for it serviceability . (g) Re-assembling the Geyser, re-install and testing complete. Note : Parts / components of geysers found unserviceable shall be replaced by the contractor. New parts/components required shall be measured and paid separately under item No 136 to 139 here-in-after as supply only and labour charges required for replacement are deemed to be included in the quoted rate of item no. 134
All as per item No.134.00 here-in-above but Geysers of capacity 25 ltrs .
Supply only thermostat of Type EST 11 / 20A, 250 Volt of approved make and having ISI mark all as specified.
All as per item No.137 here-in-above but Type EST 7 / 15 A , 250 Volt
Supply only heating elements of capacity 2 KW AC 240 volts suitable for storage type electric water heater as per site requirement (press type /screw type/triangular/circular base or ceramic cartige type), ISI marked all as specified and as directed.
All as per item No.138.00 here-in-before but of capacity 1.5 KW AC 240 volts ISI marked and as per sample.
(Note : The Scope of Work contained in 'Sch of Credit' amounting to Rs. 40266.00 (refer Tender Srl Page No 36). The Quoted sum shall be arrived at after deducting the amount of “Sch of Credit” from the total amount of the ‘BoQ’
M/S G D CONSTRUCTION
NAGALAND AGENCIES CO
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .