Loading…
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹4.8 LAccepted-AOC 93 2B DR GIRINDRA SEKHAR BOSE ROAD KOLKATA 700039 | KOLKATA | WEST BENGAL | 700039 | L1 | Accepted-AOC Quoted rate stands Lowest (L1) | |
| 2 | L2₹4.9 L+₹8,682.09 (1.80%)Rejected-Finance RABINDRA NAGAR SILIGURI 734 006 | SILIGURI | DARJEELING | WEST BENGAL | 734006 | L2 | Rejected-Finance Rejected due to High rate. | |
| 3 | L3₹5.2 L+₹36,821.32 (7.65%)Rejected-Finance | L3 | Rejected-Finance Rejected due to High rate. |
Tender Value
Refer Docs
EMD Value
₹10,000
Closing Date
14 Jul 2025, 12:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Executive Engineer Electrical DIV I HD
New Secretariat Building B Block Room No1 Ground Floor 1 KS Roy Road Kolkata 700001
Internal electrification and outdoor illumination works of two storied office building including store room and site office for both electrical and civil wing at backside of Darjeeling Rest Shed at Darjeeling.
2025_HSD_874078_1
WBHD/EE/ED-1/eNIT-95/2025-26
Open Tender
ELECTRICAL WORKS ORG
Item Rate
15 days
Darjeeling
Please refer Tender documents.
5 documents required · 5 mandatory
₹10,000
29 Oct 2025
4 Jul 2025
16 Jul 2025
4 Jul 2025
14 Jul 2025
4 Jul 2025
Amount
Sub Head-1 Point wiring Distribution wiring in 2 x 22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire (Brand approved by EIC) in 20mm size PVC rigid conduit 'FR' (Precision make), with 1x22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire for ECC, to light/fan/call bell points with Modular type switch (Brand approved by EIC) fixed on Modular GI switch board with top cover plate and 2 no. suitable size “Ph & N” copper bar & earthing attachment fixed on wall incl. mending good damages to original finish. Average run 8 Mtr
Distribution wiring in 1.1 KV grade 22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire (Brand approved by EIC) in 20mm size PVC rigid conduit 'FR' (Precision make), with 1.1 KV grade 1 x 22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire as ECC, to 6A 3 pin Modular type plug socket & switch (Brand approved by EIC) on 4 Module GI switch board with 3/4 Module top cover plate on wall incl. necy. connection making earthing attachment, painting and mending good damages to building works. On Board
Sub Head-2 Switch & Socket Supplying & Fixing GI Modular Switch Board of the following sizes complete with three no. suitable size Copper bar with holes (for Ph, N & E) fixed on bakelite/Hard Rubber insulator over the MS welded chairs incl. top cover flushed in wall for housing the board after cutting the brick wall incl. making earthing attachment, painting and mending good damages to building works (Legrand myrius or equivalent model as per direction of E.I.C).6 Module
Supply & Fixing 240 V 6 A Modular type switch (Brand approved by EIC) on existing GI Modular type switch board having top cover plate and making necessary connections as required (Legrand myrius or equivalent model as per direction of E.I.C)
Supply & Fixing 240 V, 6A, 5 pin Modular type plug socket (Brand approved by EIC), without switch & plug top, on existing GI Modular type switch board with top cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc. (Legrand myrius or equivalent model as per direction of E.I.C)
Supply & Fixing 240 V, 16 A, 3 pin Modular type plug socket (Brand approved by EIC) with 16A Modular type switch, without plug top on 4 Module GI Modular type switch board with top cover plate flushed in wall incl. S&F switch board and cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc. (Legrand myrius or equivalent model as per direction of E.I.C)
Supply & Fixing 240 V, 25 A, 3 pin Modular type plug socket (Brand approved by EIC), without plug top and switch with 2 Module GI Modular type switch board with top cover plate flushed in wall and making necy. connections with PVC Cu wire and earth continuity wire etc.(Legrand myrius or equivalent model as per direction of E.I.C)
Supply & Fixing 240 V,25 A, 3 pin Modular type plug top with indicator ((Legrand or equivalent model as per direction of E.I.C) & necy. Connections.
Supply & Fixing 240 V 16 A Modular key type switch (Brand approved by EIC) on GI Modular type switch board having top cover plate and making necessary connections as required (Legrand myrius or equivalent model as per direction of E.I.C)
SUB-HEAD 3--BDB,PDB,VTPN ETC Supplying and fixing double-door SPN MCB Distribution Board with IP-42/43 protection, concealed in wall after cutting the wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment. 2+12 Way [Legrand Enclosure: 607712) or equivalent model of L&T/ABB] as approved by EIC.
Supplying and fixing double door Horizontal TPN MCB Distribution board with IP-42/43 protection, concealed in wall as per GS.( Make - Legrand/L&T/ABB) as per direction of EIC. ) 6 Way [Make - Legrand, Enclosure-607716/ or equivalent model of L&T/ABB as per choice of E.I.C]
Supplying and fixing 240/415 V MCB Isolator on din rail of existing DBs and necessary connection as perGS [Make-Legrand/L&T/ABB) as per direction of EIC. ] 63 A FP
Supplying and fixing 240/415 V MCB of Breaking capacity 10kA & C characteristics on din rail of existing DBs and necessary connectionas per GS [Make- Legrand/L&T/ABB) as per direction of EIC. ] 6-32 SP
Supply & fixing of Hylam sheet ot thickness 6mm of 12'' x 12'' size to be fixed on angle iron frame on wall & 3 nos 100 Amp kitkat type fuse to be fixed on hylam sheet. (Make: Havells/ Anchor)
SUB-HEAD 4-- Polythene pipe and wires Distribution wiring in 1.1 KV single core stranded 'FR' PVC insulated & unsheathed copper wire (Brand approved by EIC) in 20mm size PVC rigid conduit 'FR' (Precision make) incl. necy. fittings as required (KEI/Polycab/Finolex as per choice of E.IC) 2 x 22/0.3 (1.5 sqmm) + 1 x 22/0.3 (1.5 sqmm) ECC
2 x 36/0.3 (2.5 sqmm) + 1 x 22/0.3 (1.5 sqmm) ECC ( for power board & Geyser)
2 x 56/0.3 (4 sqmm) + 1 x 36/0.3 (2.5 sqmm) ECC (for AC)
2 x 84/0.3 (6 sqmm) + 1 x 56/0.3 (4 sqmm) ECC ( for SPN DB)
Supplying and Drawing 1.1 KV single core stranded 'FR' PVC insulated & unsheathed single core stranded copper wire (Brand approved by EIC) of the following sizes in the prelaid polythene pipe and by the prelaid GI fish wire and making necy. connection as required (KEI/Polycab/Finolex as per choice of E.IC) 4x80/0.4 (10 sqmm) + 2x84/0.3 (6 sqmm) as ECC
S & F solderless Copper socket by crimping of Copper wires. 2.5 sq mm
SUB-HEAD 5--Supplying & Laying of Cable Supply of 2 Core XLPE Insulated & Sheathed Armoured stranded Aluminium Conductor cables for Working Voltage up to 1100 Volts of following sizes [ Make Polycab / RR /KEI/ as approved by E.I.C] 2 CORE 6 SQMM (for compound light )
Laying of cable upto 2 core 25 sqmm on wall/surface incl. S & F MS saddles with earthing attachment in 10 SWG GI (Hot Dip) Wire, making holes etc. as necy. mending good damages and painting
Laying of one No. cable upto 35 sqmm in underground trench 460 mm wide x 760 mm average depth, with brick protection on the top of the cable with 8 (eight) Nos. bricks per metre, including filling the space between the brick & cable and also the trench with shifted soil, leveling up and restoring surface duly rammed
Supplying & fixing medium gauge GI Pipe ( ISI-Medium) Protection with necessary fittings as per GS. 40 mm dia
Supplying and fixing compression type gland complete with brass gland, brass ring & rubber ring for dust & moisture-proof entry of XLPE/PVC armoured cables as below : 2 CORE upto 06 SQMM.
Finishing the end of following XLPE/PVC armoured cables by crimping method incl. supplying and fixing solderless socket (Dowels make), tapes, anticorrosive paste & jointing materials : 2 CORE 06 SQMM
SUB-HEAD 6---SUPPLY OF LIGHT FITTINGS Supply and delivery of 2ft single LED tube incl. Supply of 1nos. 12W LED Tube [Make- Philips cat no- BN 021 LED12S 6500 PSU GR or equivalent model of /CG / Bajaj /Havells as approved by E.I.C]
Supply of 15 W Recessed mounted round LED light fittings having 105 lm/Watt and CCT-6500K with glare free uniform illumination Incl. necessary connections as per direction of EIC. (make- Phillips: Duraslim LED Downlighter or equivalent model of Havells/CG / Bajaj as approved by E.I.C )
Supply of 9W LED bulb (Bajaj/CG/Philips) on existing batten holder
Supply & Fixing metal body decorative single head wall light fittings with 1no. E27 9 watt warm white light on wooden circular board (Make philips/ crompton/bajaj/ Havells Florene wl1sB22ssrpcp)
S&F LED picture light (Make-Philips /CG/Havells)
Supply & Fixing Surface mounted round shape LED light fittings include light with durable housing with Al heat sink with diffuser to give glare free light with removable driver(Make-Philips Cat No. SM250C LED 7S - 6500 PSU -WH/Havells/Crompton).
SUB-HEAD 7-- FIXING OF LIGHT FITTINGS Fixing only single/twin florescent light fitting complete with all accessories Directly on wall/ceiling by screws etc.]
Supply & Fixing angular batten holder (Anchor) on 75mm dia PVC round block / round bakelite on wall/ceiling.
Fixing only lamp
Fixing of circular recessed mounted LED fittings after cutting of false ceiling and finising of same
Sub head-08 compound light Supply of 240V, 36 W LED Street light luminarie complete with all accessories and equipped with IP66 Protection (Philips Cat no BRP 331 LED46 CW R5N PC PSU S1 SPD or equivalent model of Crompton-LSTS-36-CDL-M /Bajaj as approved by E.I.C) on existing GI pipe bracket as per direction of E.I.C
Fixing only outdoor / street light type fluorescent light fitting complete with all accessories to be fixed/projected from the wall of the building incl. making holes to building, S&F 40 mm dia GI pipe (ISI-Medium) 1.50 mts. average length, with GI socket at one end and thread at the other end & suitable bend to house the fitting & making necy. connections with S&F necy. length of 1.5 sqmm PVC insulated single core stranded annealed copper wire and making connections as required and mending good damages to wall and painting.
Supplying & Fixing GI waterproof type looping cable box size 200x150x100 mm deep having 4 mm thick comprising of one 250 V 15 A kit-kat fuse unit, one NL on porcelain insulator, one compression type brass cable gland for upto 2- core 16 sqmm PVC/A cable and having lined with rubber gasketted GI top cover with brass machine screws etc., earthing terminal with lug, on steel tubular pole near base, including S&F 40x6 mm thick, MS clamps with bolts, nuts etc. including painting with anticorrosive paint.
Supplying and Drawing 1.1 KV single core stranded 'FR' PVC insulated & unsheathed single core stranded copper wire (Brand approved by EIC) of the following sizes in the prelaid polythene pipe and by the prelaid GI fish wire and making necy. connection as required b) 3 x 22/0.3 (1.5 sqmm) {loop box to fittings}
Supply and fixing of 240V, 7 W Warm White LED Bollard luminarie complete with all accessories and equipped with IP65 Protection (Philips or equivalent model of Crompton/Bajaj as approved by E.I.C) as per direction of E.I.C, Bamboled Bollard)
SUB-HEAD 09 --MISCELLANEOUS Supplying & Fixing 240 V AC/DC superior type Ding-Dong Call Bell (Anchor) on HW board incl. S&F HW board
Supply of Heavy duty exhaust fan 80 Watt, 230 mm (9'') sweep 1370 RPM (Make EPC or equivalent model of USHA) as per choice of E.I.C
Fixing only exhaust fan after making hole in wall and making good amages and smooth cement finish etc. as practicable as possible and providing necy. length of PVC insulated wire and making connection for exhaust of following diameter: b) 23 cm (9")
Supply & Fixing louver shutter on wall with necy. bolts & nuts (6 mm dia x 62 mm long) a) For Al 23 Cm Exhaust fan (9'')
Supply and Fixing of 10 L Geyser incl. necessary holding clamp (Make: HAVELLS Fabia/Crompton Arno Neo 5s or equivalent model as approved by EIC/Authority) incl. IN/OUT hot & cold wter pipe line of good quality and necessary interconnection as per direction of EIC. (5Star)
Supply and Fixing of 15 L Geyser incl. necessary holding clamp (Make: HAVELLS/Crompton Arno Neo 5s or equivalent model of Venus as approved by EIC/Authority) incl. IN/OUT hot & cold wter pipe line of good quality and necessary interconnection as per direction of EIC
Supply of 2000W Heat Convector Room Heater. [Instant Warmth: 2000 Watts Heat Convector Room heater, Customized to heating needs with an adjustable thermostat and two heat settings (1000 W/ 2000 W) ,Featuring auto thermal shutoff to prevent overheating & RX8 comes with an adjustable height setting for convenience. (Make: Bajaj Majesty RX 8 2000 Watts or equivalent model of Havells/USHA as per choice of E.I.C) (Colour: Black, ISI Approved)
Sub Head 10 Earthing :- Excavation of soil for installation of Earth Electrode and filling & ramming. B) For Morrum Soil
Earthing with 50 mm dia GI pipe 3.64 mm thick x 3.04 Mts. long and 1 x 4 SWG GI (Hot Dip) wire (4 Mts. long), 13 mm dia x 80 mm long GI bolts, double nuts, double washers incl. S & F 15 mm dia GI pipe protection (1 Mts. long) to be filled with bitumen partly under the ground level and partly above ground level driven to an average depth of 3.65 Mts. below the ground level as below: a) By ISI-Medium GI pipe
Supplying & fixing earth busbar of galvanized (Hot Dip) MS flat 25 mm x 6 mm on wall having clearance of 6 mm from wall including providing drilled holes on the busbar complete with GI bolts, nuts, washers, spacing insulators etc. as required
Connecting the equipments to earth busbar including S & F GI (Hot Dip) wire of size as below on wall/floor with staples buried inside wall/floor as required and making connection to equipments with bolts, nuts, washers, cable lugs etc. as required and mending good damages (a) iii) No 8 SWG
SUB-HEAD 11 -- Lightning Conductor S & F Lightning Conductor Air Terminal made of 20 mm dia 1000 mm long GI pipe (ISI Medium) having five discharge prongs of 4 SWG GI (Hot Dip) wire at top duly soldered with 7/16 stranded GI (Hot Dip) wire and 85 mm dia 6 mm thick GI base plate at bottom incl. necessary holes etc. complete duly grouted on the parapet etc. in CC mortar (4:2:1) as per GS
Supply & Fixing 7/10 SWG GI (Hot Dip) stranded wire for Horizontal run on the parapet/roof/wall with GI saddles spaced not exceeding 1100 mm apart incl. mending good the damages to building works.
Supply & fixing of 7/10 SWG stranded GI (Hot Dip) wire for vertical run on wall with GI saddles spaced not exceeding 1000 mm apart incl. mending good the damages to building work.
Supply, Laying & Fixing of 50mm x 6mm galvanized (Hot Dip) steel strip in underground trench for interconnection between the Earth Points by proper welding and painting the lap & 'T' joints with 2 (two) coats of bituminous paint for making a Earth Grid.
Hiring charges for scaffolding arrangement including dismantling at the end of work and carriage, for LC installation, per storey of building per vertical run
Supply & Fixing of Testing Joints by 20 mm x 3 mm thick GI (Hot Dip) strip 125 mm long grouted on wall having clearance of 6 mm from wall for making connection with thimbles at the end of 7/10 SWG GI (Hot Dip) stranded Wire and 4 SWG GI (Hot Dip) wire of vertical conductor and conductor from earth electrode complete with S & F thimbles, GI bolts, nuts, check-nuts, spring washers etc. as required
Earthing with 65 mm dia GI pipe (TATA-Medium)x 3.0 Mts. long and 1 x 19/10 stranded GI (Hot Dip) wire (4 Mts. long), 20 mm dia x 125 mm long galvanized bolt, double nuts, double washers including socketing at both ends of stranded GI (Hot Dip) wire by crimping sockets/ thimbles and S & F 40 mm dia GI pipe (ISI-Medium) protection (3 Mts. long) to be filled with bitumen partly under the ground level and partly above ground level to an average depth of 3.65 Mts
Excavation of soil for installation of Earth Electrode and filling & ramming as to GS. (For morum soil)
Making soldered joints between conductor/ down pipes / other metallic objects by 7/10 stranded GI (Hot Dip) wire incl. supply of jointing materials & painting with 2 (two) coats of Bituminous paint
Making soldered joints between conductors, conductors and air terminals for 4 SWG GI (Hot Dip) wire incl. supply of jointing materials and painting with 2 (two) coats of bituminous paint
Add. G.S.T.@ 18% (on Total from item no 1 to 66) to be calculated by bidder
Add. LWC.@ 1% to be calculated (on total from item no 1 to 66 + GST@18%) by bidder
M S MAYA AND SONS (BID ID -6703653)
M/S Basak Electrical Repairing House (BID ID -6703881)
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .