| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹38.8 LAccepted-AOC | L1 | Accepted-AOC Lowest and Reasonable | |
| 2 | L2₹41.6 L+₹2.8 L (7.19%)Rejected-Finance | L2 | Rejected-Finance Not Lowest | |
| 3 | L3₹42.3 L+₹3.5 L (9.01%)Rejected-Finance | L3 | Rejected-Finance Not Lowest | |
| 4 | L4₹43.4 L+₹4.5 L (11.7%)Rejected-Finance | L4 | Rejected-Finance Not Lowest | |
| 5 | L5₹44.0 L+₹5.2 L (13.3%)Rejected-Finance | L5 | Rejected-Finance Not Lowest |
Tender Value
₹41 L
Closing Date
30 Nov 2021, 6:00 pmClosed
GE Golconda
GE GOLCONDA LANGER HOUSE OPP MILITARY HOSPITAL HYDERABAD TELANGANA
SPL REPAIRS TO BLDG NOS 158 159 AND 286 TOILET BLOCK AT MKD LINES STORAGE TANK NEAR ARTY CENTER AND PROV OF 8 BATHROOMS WITH WATER TANK NEAR BLDG NO E25 OF 3 DOGRA UNDER GE GOLCONDA
2021_MES_486004_1
GE/GOL/TOKEN NO 51 OF 2021-2022
Open Tender
Civil Works
Item Rate
180 days
GE Golconda
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
GE Golconda
Exempted
12 Apr 2022
2 Nov 2021
2 Dec 2021
2 Nov 2021
30 Nov 2021
16 Nov 2021
2 Nov 2021 - 15 Nov 2021
Amount
Surface excavation n.exc 30cm deep and averaging 15cm deep and getting out in hard/dense soil.
Excavation in trenches n.exc 1.50m wide and n. exc 1.50m in depth and getting out in hard/dense soil.
Returnng, filling in including spreading, levelling, watering and well ramming in layers not exc 25cm
Spreading & Levelling and well ramming including watering as required in layers n.exc 25 cm thick
Removing excavated material n exc 50m and depositing where directed at a level n exc 1.5m above the starting point.
M & L for sand filling under floors or in foundations including watering and consolidation complete all as specified and directed.
M&L for PCC type D2 1:4:8 type D2 (using 40mm graded stone Aggregate) in foundations, filling and mass concrete complete all as specified and directed.
Use & waste of form work to sides of concrete foundations rafts, footing, base of columns, raft and raft beams, sides & soffits of foundation (if any) and plinth beams and similar work for rough finished flat surfaces complete all as specified and directed.
M & L for reinforced Cement Concrete (Nominal mix) type B1 1:2:4 (using 20 mm graded stone aggregate) in foundations including rafts, footings and mass concrete, foundation beams, plinth beams, bases for columns, basement slabs etc complete all as specified and directed.
Use and waste of form work to sides and soffits of floor or roof beams, lintles, cantlevers, shelves incl supports etc for rough finished surface of concrete flat complete all as specified and directed.
M&L for reinforced cement concrete (Nominal mix) type B1 1:2:4 (using 20 mm graded stone aggregate) in lintel bands, roof beams and cantilevers etc complete all as specified and directed.
Use & waste of formwork to sides of Square, rectangular or polygonal columns/ pillars, posts, struts and stanchions etc for rough finished of concrete complete all as specified and directed.
M & L for reinforced Cement Concrete (Nominal mix) type B1 1:2:4 (using 20 mm graded stone aggregate) in Columns, piers, posts and struts complete all as specified and directed.
Use and waste of form work to chullah hoods,chajjas troughs and similor items including edges for rough finished surfaces of concrete flat complete all as specified and directed.
M&L for reinforced Cement Concrete type B1 1:2:4 (using 20 mm graded stone aggregate) nominal mix as in Chajjas complete all as specified and directed.
Use and waste of formwork to soffits of suspended slabs flat such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick (Horizontal or sloping) for rough finished surface complete all as specified and directed.
Use and waste of formwork to edges of concrete flats, treads, breaks in floors, window cills, concrete railings,openings in concrete walls, floor and roofs n exc 20 cm wide and sides of RCC/PCC bands in walls, horizontal or sloping and similar work exc 10cm but n exc 20cm wide for rough finished surfaces of concrete flat complete all as specified and directed.
Use & waste of formwork to faces of walls, retaining walls, abutments and similar work including attached pillasters, buttresses, etc; vertical or to batter for fair finished surfaces curved complete all as specified and directed.
M&L for reinforced Cement Concrete type B1 1:2:4 (using 20 mm graded stone aggregate) nominal mix as in slabs supported on walls, beams and columns in floors, roofs, landings balconies canopies, desk slabs and in shelves and the like complete all as specified and directed.
M & L for reinforced Cement Concrete Type M-30(DESIGN MIX) using 20 mm graded granite stone aggregate) in foundations including rafts, footings, raft beam, plinth beams and mass concrete complete all as specified and directed.
M & L for reinforced Cement Concrete Type M-30 (DESIGN MIX) (using 20 mm graded granite stone aggregate) in Walls, retaining walls, basement walls, ballast walls and the like; any thickness; above top of footings; including attached pilasters and buttresses complete all as specified and directed.
M&L for mild steel TMT bars 10mm dia and over, cut to length bent to shap required including cranking, bending spirally for hooping for columnshooking ends and binding with and including mild steel wire (annealed not less than 0.9 mm dia or securing with clips complete all as specified and directed.
-Ditto- all as per item 22 above but 5mm dia and over upto and incl 10 mm dia in spacers, stirrups and binders.
M & L for brick work with sub class 'B' bricks, straight or curved on plan exc. 6m mean radius built in CM 1:6 complete all as specified and directed.
M & L for brick work with sub class 'B' bricks, straight or curved on plan exc. 6m mean radius for half brick wall built in CM 1:4 complete all as specified and directed.
Demolition of brick work or stone masonry, built in cement mortar complete all as specified and directed by Engr-in-Charge.
Demolition of cement concrete (Un-reinforced) in ground floors and pavings n exc. 15cm thick.(Below or above ground level).
Demolition of cement concrete (reinforced) of any description and in any position not otherwise specifically provided for.
M&L for Pre Cast Cement Concrete 1:2:4 type B1 (using 20 mm graded aggregate) as in Cover slab for manholes etc set in cement mortor 1:4 including use and waste necessary form work (Reinforced shall be measured and paid seprately) complete all as specefied and directed.
Taking down cement plaster on brick wall/stone wall, ceiling, sunken floors etc, raking out joints, hacking for key & scrubbing with water completely complete all as specified and directed by Engr-in-Charge.
M&L for rendering 10 mm thick on fair faces of brick work or concrete surfaces in cement mortar 1:6, finished even and smooth without using extra cement complete all as specified and directed.
M&L for rendering 5 mm thick on fair faces of concrete surfaces as in ceilings in CM 1:3, finished even and smooth without using extra cement complete all as specified and directed.
M&L for rendering 15mm thick in CM 1:4 mixed with WPC, on fair faces of brick work or on concrete surfaces finished even and smooth without using extra cement complete. (IWPC measured and paid separately) complete all as specified and directed.
M&L for rendering 10mm thick in CM 1:3 on fair faces of brick work or on concrete surfaces finished even and smooth (without using extra cement) mixed with WPC (WPC measured and paid separately).
Supply only integral water proofing compound complete all as specified and directed.
M & L for three coats of white wash on newly plastered surfaces of wall including preparation complete all as specified and directed.
M & L for three coats of white wash on newly plastered surfaces of ceilling including preparation complete all as specified and directed.
M&L for preparation of new plastered surfaces of walls and applying two coats of cement based paint complete all as specified and directed.
M&L for complete removal of existing treatment and praparation of Old plastered surfaces and applying One coat of Cement base paint on walls complete and all as specified and directed by Engr-in-Charge.
M&L for Praparation of Old plastered surfaces and applying One coat of White wash on Ceiling complete all as specified and directed by Engr-in-Charge.
M & L for preparation of old painted steel surfaces of any description, over 10 cm width or girth, not otherwise described and applying one coat of synthetic enamel paint.
Hacking out old broken glass (any thickness, size quality or description) from wooden frame or stone concrete or bricks sorrounds grazed with putty or fixed with beads.
M&L hardcore of gauge n.exc 63mm of broken stone or boulders, deposited, spread and levelled in layers n.exc 15cm thick, watered and rammed to a true surface complete all as specified and directed.
M & L for 75mm thick cement concrete type D-2, 1:4:8 (using 40mm graded stone aggregate) as in sub base to floor complete all as specified and directed.
M&L for 25mm thick cement concrete type B-1,1:2:4 (using 20mm graded stone aggregate) as slevelling course to flooring complete all as specified and directed.
M&L non skid coloured ceramic tiles 7 to 8mm thick (square or rectangular) area of each tile exceeding 0.06sqm but not exceeding 0.11 sqm, as in floors laid over and including cement screed in CM 1:6 15 mm thick set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specified and directed.
M&L glazed ceramic coloured tiles of size 300x200x7mm thick for vertical surfaces as in dado/ skirtings set and jointed in neat cement slurry and pointed in white or coloured cement to match, over and including back coat 10mm thick rendering in CM 1:4 complete all as specified and directed.
M&L chequered cement concrete tiles 20 cm x 20 cm x 25 mm thick with grey cement and pigment, machine pressed, set jointed and pointed in neat cement slurry in floors including 15 mm thick screed bedding layer in CM 1:6.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing) and rubbish off the premises.
M & L for 75 mm thick Cement concrete 1:3:6 type C-2 (using 40 mm graded crushed stone aggregate ) as in plinth protection finished even aned smooth without uisng extra cement complete all as specified and directed.
Taking down chowkats or frames with shutters (without taking off shutter from the frames) n.exc. 1.5 sqm complete all as specified and directed.
S&F solid PVC door frame of size 50mmx47mm made out of 5mm plain colour PVC sheet reinforced with MS square tube, fixing in opening complete all as specified and directed.
S&F factory made solid panel PVC door shutter 30mm thick (Style) consisting of frame made out of M.S tubes for top and bottom rails. M.S frame shall be covered with heat moulded plain colour PVC 'C' channel moulded plain colour PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail and bottom rail on either side and as gap insert for top rail and bottom rail; Panelling of plain colour PVC sheet to be fitted in the MS frame welded/sealed to the stiles & rails with suitable PVC sheet beading, & joined together with solvent cement fixing in frame at site complete all as specified and directed.
S&F 100 mm long extruded Aluminium alloy butt hinges fixed to PVC door shutter complete all as specified and directed.
S&F 150mm long aluminium anodized barrel tower bolts of extruded section complete all as specified and directed.
S&F 125 mm long alluminium alloy anodized handles fabricated type complete all as specified and directed.
S&F stop valve/ cock 15mm bore cast copper alloy fancy, chromium plated with long shank and cup, screwed down high pressure fixed to iron pipes or for unions complete all as specified and directed.
S&F bib tap15 mm bore, cast copper alloy fancy type, screwed down, screwed for iron pipe or for brass ferrule complete all as specified and directed.
S & F for aluminium anodised, Tubular towel rail, 20mm dia, D type, 60cm long between flanges alongwith brackets and fittings, etc complete all as specified and directed complete all as specified and directed.
S & F in repair for aluminium anodised, Tubular towel rail, 20mm dia, D type, 60cm long between flanges alongwith brackets and fittings, etc complete all as specified and directed complete all as specified and directed.
S&F 125mm dia brass chromium plated shower rose with or without swivel joints including fixing to steel pipe or union complete all as specified and directed.
S& F PTMT Soap dish 100mm dia any type, fixed to plugs with chromium plated brass screws complete all as specified and directed.
S&F rotational moulded polyethylene water storage tanks (cylinderical vertical with closed top) hoisted and fixed in position all as specified in SSR Part I of capacity 1000 litre complete all as specified and directed.
S&F rotational moulded polyethylene water storage tanks (cylinderical vertical with closed top) hoisted and fixed in position all as specified in SSR Part I of capacity 1000 litre including dismantling existing tankcomplete all as specified and directed.
S&F ball valves high pressure of PTMT with epoxy coated aluminium rod and high density plastic ball screwed for iron pipe and fixed to 25mm bore pipe complete all as specified and directed.
S&F in repair PVC ball valves high pressure of PTMT with epoxy coated aluminium rod and high density plastic ball screwed for iron pipe and fixed to 25mm bore pipe complete all as specified and directed.
S&F in repairs Vitreous China squatting pan , "Orissa" pattern size 580 X 440 mm white with intgrel footrest (excluding flushing cistern & flush pipe) including 110mm dia PVC SWR 'P' or 'S' trap complete including provision of cement concrete all as specified and directed by Engr-in-Charge.
S&F in repair PVC valveless syphonic action type flushing cistern 10 lit capacity low level white with inlet, ball valve, float and handle including brackets and 32mm PVC flush pipe complete all as specified and directed by Engr-in-Charge.
S & F PVC connection 15 mm size with PTMT nuts, length 450 mm complete all as specified and directed.
S&F in repair 15 mm dia fancy type bib tap cast copper alloy chromium plated, screwed down, screwed for iron pipe or for brass ferrule complete all as specifie and diredted.
S&F in repairs 15 mm dia Brass Stop valves/angle cock chromium plated fancy type, screwed down, high pressure, with crutch handle, screwed both ends for iron pipe or for unions complete all as specified and directed by Engr-in-Charge.
S&F GI tube 15mm dia medium grade with all fitings and fixed to wall, celing or laying in trenches including taking up and down complete all as specified and directed by Engr-in-charge.
S&F GI pipes medium grade 15 mm bore with all fittings fixed to walls and ceilings or laid in floors complete all as specified and directed.
S&F GI pipes medium grade 20 mm bore with all fittings fixed to walls and ceilings or laid in floors complete all as specified and directed.
S&F GI pipes medium grade 20 mm bore with all fittings laid in trenches complete all as specified and directed.
S&F GI pipes medium grade 25 mm bore with all fittings laid in trenches complete all as specified and directed.
S&F GI tube 40mm dia medium grade with all fitings and fixed to wall, celing or laying in trenches including taking up and down complete all as specified and directed by Engr-in-charge.
S&F GI pipes medium grade 50 mm bore with all fittings laid in trenches including taking up or down existing unserviceable GI tubing 50 mm bore complete all as specified and directed.
Taking up or down GI steel tubing and connections for removing unserviceable GI pipe out of site, size 25mm bore all as specified and directed
S & F gun metal globe or gate valve 25mm bore with iron wheel head screwed both ends for iron pipe complete all as specified and directed.
S & F gun metal globe or gate valve 20mm bore with iron wheel head screwed both ends for iron pipe complete all as specified and directed.
S & F gun metal globe or gate valve 25mm bore with iron wheel head screwed both ends for iron pipe including taking out existing unserviceable gate valve complete all as specified and directed.
S & F gun metal globe or gate valve 50 mm bore with iron wheel head screwed both ends for iron pipe including taking out existing unserviceable gate valve complete all as specified and directed.
S & F in repair 125mm size brass chromium plated shower rose with or without swivel joints including fixing to steel pipe or union fixed complete all as specified and directed.
S & F 110 mm dia PVC (SWR) pipe single socketed in any length with rubber ring joints laid in trenches or in floors complete all as specified and directed.
Taking down PVC SWR pipe 110mm dia including fittings complete all as specified and directed.
S & F 110 mm dia PVC (SWR) junction (Single T) equal or unequal with access Door complete all as specified and directed.
S & F 110 mm dia PVC (SWR) junction double Y equal or unequal with access Door complete all as specified and directed.
S & F 75 mm dia PVC (SWR) junction double T equal or unequal with access Door complete all as specified and directed.
S & F 110 mm dia PVC (SWR) bends any radius complete all as specified and directed.
S & F 110 mm dia PVC (SWR) bends any radius with oval access door complete all as specified and directed.
S&F PVC (SWR) vent cowl complete all as specified and directed.
S & F 75mm dia PVC (SWR) pipes single socketed in any length with rubber ring joints, fixed to wall using clamps, laid in trenches or in floors complete all as specified and directed.
Taking up or down PVC SWR pipe 110mm dia including fittings complete all as specified and directed.
S&F 75 mm dia PVC (SWR) bend with oval access doors complete all as specified and directed.
S&F 75mm bore PVC (SWR) bends any radius complete all as specified and directed.
S&F PVC (SWR) floor trap 75mm dia outlet, plain with gratings including jointing with solvent cement complete all as specified and directed.
S&F in repair PVC (SWR) floor trap 75mm dia outlet, plain with gratings including jointing with solvent cement complete all as specified and directed.
Demolition and breaking up drain pipes, 150mm internal dia, (Salt glazed ware, AC or Reinforced concrete) set in cement mortar and haunching complete.
M & L salt glazed stone ware pipes (Grade 'A') 150mm internal dia laid in trenches and jointing socket end with packed spun yarn and cement mortar1:1
M&L for concrete bed to drain pipes 150mm dia using cement concrete 1:3:6 type C2 including packing under and haunching against the sides of pipes after they are laid and tested in complete.
M&L 100mm thick cement concrete type B-2 1:2:4 (using 40mm graded stone aggregate) as in floors complete all as specified and directed.
S&F Collapsible steel gates, consisting of channel pickets, pivoted flat bars, top and bottom runners, brass handles etc., erected in position and securing runners with holdfasts and brackets complete all as specified and directed.
M&L for two coats of synthetic enamel paint to new steel surfaces over a coat of red oxide zinc chrome primer including preparation of surfaces, area exc 10cm width & girth complete all as specified and directed.
S&F steel ventilator with top hung shutter including hinges, steel peg stay, complete all as specified and directed.
S&F Figured glass pin headed quality in squre n.exc. 0.5 Sqm in each pane of 4 mm thick complete all as specified and directed.
S&F 0.63 mm nominal dia of wire ; galvanised mild steel wire cloth and average width of aparture 1.40 mm and fixed with tinned tacks or galvanised wire stapple complete all as specified and directed.
Cutting in to existing manholes for connecting new drains making good to pipe 150mm internal dia and rendering, cutting out existing benching for and forming branch channel (1/2 round or 3/4 section) in cement concrete 1:2:4 type B-1 smooth finished and reforming benching complete all as specified and directed.
M&L for PCC 1:2:4 type B2 using 20 mm graded stone aggregate as in benching/ Coping of manholes including necessary form work complete all as specified and directed.
M & L for construction of valve chamber 90x90x90 cm inner dimensions using brick masonary in CM 1:6, PCC 1:3:6 75mm thick foundation, plastering 15 cm thick in CM 1:4 in inner side/ coping of chamber, fabrication of Iron frame 40x40x6 mm size angle iron MS cover 3 mm thick with hinges and locking arrangements duly painted with two coats of synthetic enamel paint over a coat of red oxide primer including excavation and earthwork complete all as specified and directed.
M & L for construction of valve chamber 60x60x60 cm inner dimensions using brick masonary in CM 1:6, PCC 1:3:6 75mm thick foundation, plastering 15 cm thick in CM 1:4 in inner side/ coping of chamber, fabrication of Iron frame 40x40x6 mm size angle iron MS cover 3 mm thick with hinges and locking arrangements duly painted with two coats of synthetic enamel paint over a coat of red oxide primer including excavation and earthwork complete all as specified and directed.
Cutting/ Boring on the existing GI pipe line 40/ 25mm dia (in position) for insertion of new galvanised Tee 25 x 25 mm for branch connection incl necessary jointing material complete all as specified and as directed.
Cutting/ Boring on the existing GI pipe line 50 mm dia (in position) for insertion of new galvanised Tee 50 x 50 mm for branch connection incl necessary jointing material complete all as specified and as directed.
M&L for walling of random rubble Secunderabad pattern, well bonded, bedded and solidly hearted, built in CM 1:6 complete all as specified and directed.
S&F of 3 mm thick PVC water bar/stop 250 mm wide for construction joint in RCC work complete all as specified and directed.
Taking down existing felt, plaster and preparing the surface of roof by roughening surfaces of old concrete floor or concrete surfaces by picking, sweeping clean and washing down with water to remove dust, etc.and brushing neat cement slurry @ 3 Kg per square metre, applying 10mm thick screed in CM 1:4 mixed with WPC, finished even and smooth and providing APP based polymeric membrane minimum weighing 3Kg/Sqm and minimum 3mm thick reinforced with polyster non wove fabric (weight not less than 150 gms/Sqm) laid over primed surface including bituminous primer conforming to IS-3384 applied @ 0.3 Ltrs/Sqm by forced application and applying one coat bitumen grade 85/25 @ 1.2 Kg/Sqm over finished with one coat of alluminium paint @ 100 ml/Sqm 10cm overlap fused uniformly by LPG torch flame, complete all as specified and directed by Engineer-In-Charge.
Taking out carefully copper/aluminium point wiring,Light,fan,socket or power complete with all fitting, fixtures such as switch socket out let, ceiling rose, holder, regulator, DBs etc including making good the disturbed surface of wall/floors complete.
M&L Point wiring for one light point/fan point/bell point controlled by one switch with 1.5 sqmm multistrand copper conductor cable PVC (FRLS) insulated unsheathed copper conductor single core multi stand flexible cable and 1.50 sqmm PVC (FRLS) insulated unsheathed copper conductor single core cable ( green colour) as earth lead in and including PVC rigid conduit with all fittings for concealed type on stone / brick ,masonary walls, roof etc including in new MS sunk box of required size and all as directed by Engineer-in-Charge & 3 mm thick plastic laminated sheet for housing switches sockets, regulators etc, including running chases, pinning in and making good the disturbed surfaces to match with the existing specification ,complete all as specified and directed at site.
M&L switch piano flush type single pole one way 5 Amps complete all as specified and directed.
M&L lamp holder insulated body with back plate suitable for batten fittings complete all as specified and directed.
S&F Ceiling rose surface bakelite 65 x 50 mm 2/3 terminais complete all as specified and directed.
S&F LED tube light fittings 1 x 22 W, 230V, complete with all accessories internally prewired and including LED Tube rod connecting up with twisted flexible PVC copper conductor cable of 23/0.0079 from ceiling rose all as specified and directed.
S & F New generation energy saving and environmental friendly long life LED Building Security light 1x25 W made up of pressure die cast aluminium housing with high efficient LED as lighting source with IP66 protection complete.
S&F Sheet metal enclosure MCB distribution board double door including 200 Amps bus-bar single pole and neutral 240V, 4 Ways complete all as specifide and directed.
S&F Sheet metal enclosure MCB distribution board double door with 200 Amps bus-bar single pole and neutral 240V, 4 Ways including taking down of existing sheet metal enclosure complete all as specifide and directed.
S&F MCB single pole and neutral 6 to 32 Amps 240 Volts complete all as specified and directed.
S&F MCB SP 240 Volts 6 to 32 Amps, 240 volts 50 Hz complete all as specified and directed.
S&F in repair MCB single pole and neutral 6 to 32 Amps 240 Volts complete all as specified and directed.
S&F in repair MCB SP 240 Volts 6 to 32 Amps, 240 volts 50 Hz complete all as specified and directed.
Earthing complete with galvanized steel earth plate electrode 60cmx60cmx6mm thick buried directly in ground (earth pit not less than 2.25 mtr below ground level) with top edge o the plate not less1.5 mtrs below normal ground level connected to galvanised earth lead wire 4 mm dia by means of bolts nuts, check nuts and washers of galvanized iron of steel all as shown in electrical plate No.3 of SSR Part - I connected to earthing test point incl necessary earth work, excavation, PCC 1:3:6 type CI using 20mm graded stone aggregate for earth chamber provn of PCC cover 40 mm thick 1:2:4 mm type B1 funnel with water Pipe, GI pipe, 15mm dia medium grade protection pipe 5 m, GI earth lead complete all as specified and directed by the Engr-in-charge.
Disconnecting and removing Exhaust fan from any height from electrical connection bringing down, dismantling, cleaning internally and externally thoroughly examine & replacement of split pins, cotter pins and check nuts etc overhauling, lubricating with approved lubricants, reassembling, including labour for replacement of wornout/ defective parts, refixing in original position including minor repairs for the smooth functioning and provision of new flexible wire of size 23/0.0076 multistranded copper conductor cable from ceiling rose to Exhaust fan including testing complete all as specified. NOTE :- Labour element for replacing of unserviceable parts deemed to be included in rate quoted.
Taking out defective winding and rewinding of the Exhaust fan (motor) of size 225mm/250mm complete with equivalent new super enamelled copper wire as per existing gauge and weight as per manufacturer's design and instructions including varnishing of Exhaust fan and spray Paint with one coat of synthetic enamel DUCO paint complete all as specified and directed
S&F 1100 V grade heavy duty cable PVC insulated aluminium stranded conductor served with inner sheathing of PVC tape and over all PVC sheathed twin core cable flat or circular stranded conductor of size 6 Sqmm in service connections suspended by insulated hangers not more than 1 mtr apart incl 4 mm GI suspension wire complete with all as specified and directed.
M&L House service bracket (hook type) complete with 3.0m long G.I pipe 40mm dia Medium Grade bent to shape required, fixed with nut bolts and stay including taking down of old unserviceable one all as specified and directed at site.
Neeru Constructions
BHAGYARAM ENTERPRISES
NAVANAND ENTERPRISES
c devender reddy and co
Venkat Sai Enterprises
M/S PAVANI ENTERPRISES
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .