Loading…
Loading…
Tender Value
₹5.0 Cr
EMD Value
₹2.5 L
Closing Date
4 May 2026, 5:00 pmClosed
MR Yognarayan sahu(DFLT)
EinC E/M
Shifting of 11KV line, LT line, Transformer DP, 33KV line and RMU for road widening from Thagda Bandh (Jail Tiraha chowk) to Minimata chowk four lane 4.75KM road at Dist-Durg (C.G.)
188804
NIT NO:019/TC/2026-27
RESTRICTED TENDER
WORKS
12 days
EinC E/M
Required Past Technical Experience: AS PER NIT
Required Financial Turnover (in INR): AS PER NIT
Required Bid Capacity (in INR): AS PER NIT
6 documents required · 6 mandatory
Public Works Department (PWD)
WORKS
MR Yognarayan sahu(DFLT)
RESTRICTED TENDER
ITEM RATE
A B
EinC E/M
E/M Circle, Raipur
E/M Division Durg
120
12
No
76
188804
4 May, 2026 5:00:00 PM IST
7 May, 2026 10:00:00 AM IST
13 Apr, 2026 5:00:00 PM IST
NIT NO:019/TC/2026-27
Shifting of 11KV line, LT line, Transformer DP, 33KV line and RMU for road widening from Thagda Bandh (Jail Tiraha chowk) to Minimata chowk four lane 4.75KM road at Dist-Durg (C.G.)
249945.00 INR
RTGS/CHALLAN (ONLINE) Internet Banking (ONLINE)
49989000.00
2
6 May, 2026 5:00:00 PM IST
49989000
AS PER NIT
AS PER NIT
AS PER NIT
0.00 INR
21d 4h 2m
6 documents required · 5 mandatory · 1 optional
₹0
₹2.5 L
13 Apr 2026
13 Apr 2026
7 May 2026
13 Apr 2026
4 May 2026
13 Apr 2026
6 May 2026
Supplying and fixing of Earthing Coil (Coil of 115 turns of 50 mm dia. & 2.5 Mtrs lead of 4.0 mm GI wire) (EARTHING COIL 8SWG GI WIRE 50 MM DIA 450MM height) as per REC specifications.
Supplying and fixing of Aluminium bobbin(Earth knob) as per REC specifications.
Supplying and fixing of M.S. Stay Clamp (50 mmx6 mm) and 246 mm length between 2 nos 18 mm dia holes for 16 mm bolts as per REC specifications.
Supplying and Fixing of 11 kV m.s. "V" Cross Arm Cleat type 75x40x6 mm. 1150 mm long with 18 mm dia hole for pole back clamp and 22 mm dia hole for pin insulator including drilling of holes for insulator and clamping with nuts and bolts but excluding insulator, clamp,nuts and bolts etc as per REC specifications.
Supplying and fixing of Universal hook & Bolts & nuts as per REC specifications.
Supplying and fixing of 11 kV m.s. Top Clamp Angle type 65x65x6 mm 385 mm long as per REC specifications.
Supplynig and fixing of m.s. Nuts and bolts of verious sizes 16x65 mm / 16x90 mm as per REC specifications.
Supplynig and fixing of m.s. Nuts and bolts of verious sizes 16x200 mm / 16x250 mm/ 16x300mm/ 20x75 mm/ 20x90 mm/ 20x110mm/ 24x120mm/ 16x100mm/ 16x140mm/ 16x160mm as per REC specifications.
Supplynig and fixing of m.s. Nuts and bolts of verious sizes 12x65 mm / 12x100 mm / 16x40 mm as per REC specifications.
Supplying and Fixing of Single Pole m.s. Cut Point Fitting 100x50x6 mm, 1800 mm long (11 kV Cut point channel) as per REC specifications.
Supplying and fixing of 11 KV Strain hardware fittings. (Strain H/W up to Rabbit.) as per REC specifications.
Supplying and fixing of 33 KV Strain hardware fittings. (Strain H/W for Raccoon & Dog.) as per REC specifications.
Supplying and Fixing of Transformer mounting m.s. cross arm DC channel 100x50x6 mm, 2.4 mtr long 8' centre as per REC specifications.
Supplying and fixing of Aluminium binding wire and tape as per REC specifications.
Supplying and fixing ms lt side bracket 5 pin 50x50x6 mm, 23.72 kg including drilling of holes for insulator and clamping with nuts and bolts but excluding insulator, clamp,nuts and bolts etc as per rec specifications.
Supply and Fixing of G.I. Eye Hook 236 mm long, 16 mm dia as per REC specifications.
Supplying and Fixing of G.I. WIRES: - Barbed wire 4mm 8 SWG confirming to IS:2781978 as per REC specifications.
Labour charge for Shifting of existing Service cable work to be done as per REC specifications.
Supplying and fixing of 11 kV M.S. Guarding Channel 100x50 mm 2210 mm long (1.1 MTR DPDC CROSS ARM) with 6 nos 18 mm dia holes for fixing of 16 mm Eye bolt and back clamp as per REC specifications.
Supplying and fixing of 33 kV Guarding Channel 100x50 mm, 2210 mm long with 6 nos 18 mm dia holes for fixing of 16 mm Eye bolt and back clamp as per REC specifications.
Labour Charges of Carpet guarding with 2 nos 2210 mm long M.S. gaurding channel 100x50 mm, 04 nos 245 mm back clamp, 4mm dia G.I. guard wire, and 4 nos I bolt 16 mm dia 236 mm long and 4 mm dia G.I. cross lacing first 750 mm from pole and then 2000 mm of spacing between each other for all type of H-BEAM/PCC/RSJoist pole, work to be done as per REC specifications.(Excluding materials)
Supplying and fixing dead end assembly for all size cable including drilling of holes for insulator and clamping with nuts and bolts but excluding insulator, clamp,nuts and bolts etc as per REC specifications.
Supplying and fixing of aluminium cable 1c 150 sq mm unarmoured lt pvc as per REC specifications.
Supplying and fixing of aluminium cable 1c 300 sq mm unarmoured lt pvc as per REC specifications.
Supplying and Fixing of D.O. / LA Mounting M.S. channel 75x40x6 mm, 2800 mm long as per REC specifications.
Supplying and fixing MS LT 5 pin cross arm size 50x50x6 mm, weighing 10.03 kg including drilling of holes for insulator and clamping with nuts and bolts but excluding insulator, clamp,nuts and bolts etc as per REC specifications.
Supply and Fixing of L.T. Distribution Box for 200 kVA X'mer (400 A, isolator & 6 SP MCCB of 120A) as per REC specifications.
Labour charge for Fixing of LT distribution Box with existing Cable For 200 kVA/315 KVA Transformer work to be done as per REC specifications.(Excluding materials)
Labour charge for Shifting / Inst. & wiring with existing cable of Transformer 200 kVA/315 KVA work to be done as per REC specifications. (Excluding materials)
Supplying and laying/stringing 11 kv 3 ph al ab xlpe insulated, armoured cable 3x70 (ph)+1x70 (insulated messenger cable) sqmm, normal current rating as per is 3961 as per REC specifications.
Supplying and Fixing of LT 3 phase 5 Wire Aerial Bunched Cable Confirming to IS 14255/1995 where phase conductors with XLPE insulation (Conforming to IS 8130:1984) with bare messenger cable(Conforming to IS 398(partIV):1979) of Size 3X50(Phase)+1x16(st light)+1x35(bare messenger) as per REC specifications.
Supplying and fixing MS DC cross arm (3.8 m) 8 feet channel 100x50 mm, 79.0 kg/set including drilling of holes for insulator and clamping with nuts and bolts but excluding insulator, clamp,nuts and bolts etc as per REC specifications.
Supplying and fixing of 33 kv MS V cross arm of size 75x75x6 mm weighing 25.7 kg including drilling of holes for insulator and clamping with nuts and bolts but excluding insulator, clamp,nuts and bolts etc as per REC specifications.
Supplying and fixing of 33KV top clamp (33 kV Top m.s. angle 65x65x6 mm, 5.8 kg/m with two nos. 16 mm dia hole for fixing of back clamp. and m.s. channel 100x50x6.4 mm, 65 mm long welded with angle with 20 mm dia hole for pin insulator.) as per REC specifications.
Supplying and Fixing of MS Single Pole Cut Point Fitting 100x50x6 mm, 1800 mm long (33 kV Cut point channel) as per REC specifications.
Supplying and laying hdpe pipe 200 mm id; 240 mm od in normal soil under 2.5 meter deep from ground level using pushing method as per REC specifications.
Supplying and fixing jointing arrangement of 200 mm id; 240 mm od hdpe pipe as per REC specifications.
Supplying and laying 33 kv al 3 core xlpe insulated, armoured ug cable 3x240 sqmm in existing hdpe/rcc/ hume/ stoneware/ metal pipe, normal current rating as per is 3961 and REC specifications.
Supplying and laying GI pipe 200 mm ID for cable support as per REC specifications.
Supplying and laying/stringing 33 kv 3 core al covered conductor xlpe insulated, armoured 157 sqmm, normal current rating as per is 3961 and REC specifications.
Labour charge for installation of compact R.M.U. 11 kv class sf6 / vcb type (1 incoming + 2 breaker + 1 outgoing) work to be done as per REC specifications.
Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal and salt as per specification and IS Code 3043: 1987(R 2016)
Supplying and laying 6 SWG G.I. wire at 0.50 metre below ground level for conductor earth electrode, including soldering, excavation and refilling the trench etc. as per specification.
Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing as per specification.
Supplying and fixing G.I. pipe along with wall or pole/ support with 2 Nos MS clamps for protection of under ground cable in approved manner including bolts and nuts or metal dash fasteners complete as per specification. 14.5.2 40 mm dia
Supplying and making OUTDOOR cable end jointing with heat shrinkable cable jointing kit including lugs and other jointing materials, for following size of 3 core, PILC aluminum conductor cable of 11 KV grade as per specification: 16.13.3 70 sq. mm
Supplying and making OUTDOOR cable end jointing with heat shrinkable cable jointing kit including lugs and other jointing materials, for following size of 3 core, XLPE aluminum conductor cable of 33 KV grade as per specification. : 17.12.7 240 sq. mm
Supply of "H" beam steel pole as per IS specifications in standard length for over head line work: 19.1.2 "H" beam steel pole 152x152x7x12 mm standard weight 37.1 kg /metre
Supply of steel R.S. JOIST as per IS specifications in standard length for over head line work: 19.2.2 Designation ISMB175 size 175x90x8.6x5.5mm weight 19.3 kg /metre
Erection of STEEL TUBULAR or "H" BEAM/ ISMB pole in cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size) foundation and cement concrete collar of size 0.4 metre dia and 0.50 metre height from ground level including excavation and refilling etc. as per specification of length: 19.10.4 7 metre to 10 metre
11 metre to 12 metre
13 metre to 14 metre
Supplying and erection of stay set complete (galvanized) with 19/20mm dia x 1.8 metre long stay rod, anchor plate of size 300mm x 300mm x 6.4 mm, thimble stay clamps, turn buckle (19/20mm x 600mm), strain insulator and specified G.I. stay wire etc. in cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size) foundation including excavation and refilling etc. as per specification. 20.2.1 With 7/4.00 mm dia G.I. stay wire
Supplying and erection of angle/channel iron cross arms/ bracket/ other fitting of approved size and shape including drilling of holes for insulator pins, bolts and nuts etc as per specification.
Supplying and erection of galvanized ‘D’ iron complete with shackle insulator, G.I. bolts and nuts, coach screw etc. as per specification. 20.10.1 Shackle insulator size 75mm x 90mm
Supplying and erection of 11 KV gang operated air break switch on existing two pole structure with insulators and all other accessories complete including locking arangement as per specification.
Supplying and erection of 11 KV D.O. fuse unit on existing two pole structure with insulators and all other accessories complete including locking arangement as per specification.
Supplying and erection of three piece nonlinear resistor type lightning arrestor suitable for 3 wire, 11 KV overhead lines with rated voltage 9 KV (rms) with a nominal discharge current rating of 5 KA and complete with galvanised clamping arrangement, G.I. bolts, nuts, washers etc. as per specification.
Supplying and erection of 33 KV gang operated air break switch on existing two pole structure with insulators and all other accessories complete including locking arangement as per specification.
Supplying and erection of single piece nonlinear resistor type lightning arrestor suitable for 3 wire, 33 KV overhead lines with rated voltage 30 KV (rms) with a nominal discharge current rating of 10 KA (station class) and complete with galvanised clamping arrangement, G.I. bolts, nuts, washers etc. as per specification.
Supplying and erection of galvanised stay set for 33 KV over head lines complete with 19/ 20 mm dia X 1.8 metres long stay rod, anchor plate of size 45 cm X 45 cm X 7.5 mm thick, thimble, stay clamps, turn buckle ( 20 mm X 600 mm ), 7/ 4.00 mm dia G.I. stay wire and 33 KV strain insulator etc in cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size) foundation including excavation and refilling etc. as per specification.
Supplying and erection of G.I wire of size 8 SWG to 4 SWG including binding etc. as per specification.
Supply and erection standard ACSR (aluminium conductor steel reinforced) confirming to IS 398-1961 of approved make at existing insulator at height upto 14m from ground level including stringing, binding with insulator, jointing wherever required, jumpering, tearing off connection etc complete etc. as per specification including clearing off obstacle if any: 20.32.3 Rabbit 6/1/3.35mm dia with calculated aluminium area 52.88 sq.mm, weight 214 kg/ km (100 amps)
Raccoon 6/1/4.09mm dia with calculated aluminium area 78.83 sq.mm , weight 319 kg/ km (198 amps)
Dog 6/4.72(AL), 7/1.57(S) mm dia with calculated aluminium area 105 sq.mm , weight 394 kg/ km (248 amps)
Supplying and erection DANGER BOARD made MS sheet duly painted and maked as per IE rules and specification.
Supply and errection of following Polymer Insulator with G.I. Bolt, Nuts and Straps etc. as per specification. 20.34.2 33 KV Polymer Disc Insulator {45kN}
11 KV Disc Insulator
33 KV Pin Insulator with Pin
11 KV Pin Insulator with Pin
Dismantling the existing armoured / unarmoured power cable from surface including recoiling of dismantled cable and shifting to department store. 29.9.2 Beyond 35 sqmm and upto 95 sqmm
Dismantling of steel pole, R. S. joist, girder pole from the cement concrete foundation with bracket, insulators, stay wires etc, refilling the pit upto ground level including shifting of dismantled material to department store.
Dismantling of stay set from the cement concrete foundation, refilling the pit upto ground level including shifting of dismantled material to department store.
Providing and laying Cast-in-situ cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40mm including mixing with mechanical mixer, compacting with vibrator, finishing and currying etc. complete but excluding form work.
Painting new steel and other metallic surface with red oxide zinc chromide primer paint complete with supply of material labour etc. including preparation of surface.
Painting wood steel and other metallic surface with Aluminium Paint complete with material and labour including preparation of surface.
ACTDN
ACTDSKT
ACTDD
ABVVBC
BALDUPSS
BBDUPSS
BPDUPSS
BASTARJUPS
BSTUPSS
BEMDUPSS
BSSPFK
BIJAPURUPS
BJUPSS
BSPUPSS
CGBOCW
CAOANR
CBOSE
CGHCB
CHiPS
CGKVIB
CGMSC
CGPHC
CGRBEKVN
CRSBM
CRSCS
CGRDC
CGMARKFED
CGCDF
CSIDC
CSIICL
CGSMB
CGMFPFED
CGSPDCL
CGSPGCL
CGSPTCL
CREDA
CSSDA
CGSWC
CGTBC
CMAHOR
DMSSK
DANTEWADAU
DTSCMCB
DJUPSS
DFMAIS
DOPAS
DSCSC
DOCAAC
DOEAT
DOHEC
DOLFA
DTAPC
DTSCD
DOTRATI
DPLCS
DDUPSS
DBUPSS
GDUPSS
GPMDUPSS
IIITNR
JCDUPSS
JASDUPSS
JSKBM
JSKBMD
KANDUPSS
KAWDUPSS
KONUPSS
KJUPSS
KRBAUPSS
KDUPSS
KRYAUPTS
LSPSSKM
MDMPMCSL
MMSSKM
MDUPSS
MGUHF
MUDUPSS
NDUPSS
NRANSCCL
NRANVP
ODPLCSCD
ODCTWDB
ODCSB
OSPDB
OOTCB
OCGBND
RDUPTS
RIGUPSS
RAIPURDUPS
RUPTS
RDUPSS
RNDGUPSS
SRDGUPSS
SUPSS
SUKDUPSS
SRJDUPSS
SBMPARDD
TASCDDMMAC
TWDDS
TWDDBR
TWDDBALOD
TWDDBILASP
TWDDDT
TWDDGPM
TWDDJDP
TWDDKC
TWDDKANKER
TWDDKORIYA
TWDDMSD
TWDDMC
TWDDRJN
TWDDSC
TWDDBB
TWDDD
TWDDKCG
TWDDK
TWDDRG
TWDDJSP
TWDDABK
TWDDBC
TWDDKORBA
TWDDRC
TWDDJCC
ML/GM/KG
one RCC jaali tree guard
one RCC jaali tree guard
P.cumt.
P.KG / P.LTR
P.Pair
P.Point
P.R.M.P.BOX
p.sq.mtr
P/sq.Mt.
Package
Patient
per cm height per letter
per cm height per letter
per day
PER BAG
Per bale
per bar
PER CANDIDATE
Per Candidate Per Exam
per conversation
per cubic centimeter
per day
Per Diem Rate
Per Doz
Per Hour
per HP
PER HUNDRED PIECES
Per inch
PER ITEM
Per Kg
PER KL
Per Km.
PER KW
per letter
Per Ltr
per month
Per MT
Per mtr
Per Night
per nos
PER PACKET
per page
PER PAGE
PER PERSON
Per person per day
PER PERSON PER DAY
PER PIECE
Per Plants
PER POLE
PER POLICY
per pouch
per quintal
PER RUNNING FEET
Per Set
PER SHEET
Per Sqr Km
Per square km
PER STICKER
Per Tanker
per test
PER THOUSAND
per tonne
per tonne capacity
per trip
PER UNIT
per.mtr
percentage of DPR cost
Percentage of Project Cost
PERSQF
PHPPS
PODPRC
Point
PPPMPS
PSLPDM
PSQPM
PUPYR
quintal
Roll_UD
SHEET
Sq.mtr
Tonne
USERS
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 1.07 MB
5970358142869334798_177116_Guidelines_to_Bidders_EPS_v1.pdf
NIT • 0.13 MB
7955669004344352923_188804_Form B.doc
NIT • 0.17 MB
3267325637760498983_188804_NIT.doc
NIT • 0.31 MB
6823533044632628027_188804_List of Approved Materials.doc
NIT • 0.05 MB
2441900881735177066_188804_188804 Notice.docx
NIT • 0.04 MB
3812714733318509988_188804_BOQ.xlsx
BOQ • 0.07 MB
Download all tender documents and submit your bid