Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹14.4 LAccepted-AOC AT GURUDWARA NEAR UCO BANK PO SOUTH BLANDA TALCHER DIST ANGUL | TALCHER | ANGUL | ODISHA | 759116 | L1 | Accepted-AOC Awarded to M/s Evergreen Electrical Works | |
| 2 | Rejected-Technical AT BAGHUABOL CHHAK PO HATATOTA TALCHER ANGUL ODISHA PIN 759100 | ANUGUL | ODISHA | 759100 | - | Rejected-Technical Non compliance of work experience criteria | |
| 3 | Rejected-Technical AT RAMPUR COLLIERY BRAJRAJNAGAR DIST JHARSUGUDA ODISHA 768216 | BRAJRAJNAGAR | JHARSUGUDA | ODISHA | 768216 | - | Rejected-Technical Non compliance of work experience criteria | |
| 4 | Rejected-Technical AT GURUDWARA SOUTH BALANDA TALCHER ANGUL ODISHA 759100 | ANUGUL | ODISHA | 759100 | - | Rejected-Technical Non compliance of work experience criteria |
Tender Value
₹19.4 L
EMD Value
₹24,200
Closing Date
7 Oct 2024, 5:00 pmClosed
Staff officer (EnM), Bharatpur Area
Sri Samar Parida, mob no. 94372 89178, Address Staff Officer EnM, MCL Bharatpur Area Office, N.S.Nagar, Talcher, Angul dist. 759148
Day to day maintenance of the Transformers, MOCB, OCB, 3.3 KV Starter Panel, LT Panel at CHP and RLS, Bharatpur OCP for a period of one year.
2024_MCL_318059_1
MCL/BA/EnM/e-Tender/242550 Dated 21.09.2024
Open Tender
Miscellaneous Works
Item Rate
365 days
CHP AND RLS, BHARATPUR OCP
REFER NIT
5 documents required · 5 mandatory
₹24,200
21 Mar 2025
24 Sept 2024
8 Oct 2024
25 Sept 2024
7 Oct 2024
25 Sept 2024
24 Sept 2024 - 30 Sept 2024
Amount
Maintenace of the different transformer (power & Lighting) at CHP and RLS - population 13 nos
Rubber Bush
Bushing Gasket
Neoprene type Oil Gasket/Cork Sheet
Connection Stud with Nuts and Washers as per the requirement
Removal of oil/burnt/defunt and providing & fixing of Silica gel
Dismantling, Cleaning and mainteance with opening of top Cover Conservator tank and oil draining, arresting of Oil leakage of the transformer including fixing items provided by the department or above including its safety device testing with NGR.
Transformer Oil filtration one time in a year
Repairing of the 33 KV MOCB (2 nos) - Total 6 nos.
Fixed Contact Assembly ( Upper & lower fixed Contact/ Male & Female Contact )
Moving Contact Rod Assembly
Trip/Closing/shunt Coil Assembly AC/DC
Rubberised Oil Seal
Rubberized Gasket
Indication Lamp
High Speed Tripping Relay, 110 V DC ( Master Trip Relay)
Dismantling, Cleaning and Installation of 33KV,different Amps outdoor type MOCB including Oil draining and refilling with maintenance of spring charging closing and tripping of mechanism units as required including the testing of control circuit with protective device to insure MOCB tripping during fault as required.
Maintenance of 3.3 KV OCB 800/400 Amp ( 12 nos) Make GEC - Total 18 nos.
Providing of Auxillary Contact 110/220 Volt , 2 NO 2 NO as per the requirement with installtion
IDMT Relay, 3OC & 1 EF
Earth Leakage Relay
Shunt Trip Coil Assembly
Indication lamp Assembly
Core balance current Transformer
Tripping /Closing Coil Assembly
Moving Contact
Fixed Contact
Dismantling, Cleaning and mainteance of OCB unit and checking of its incoming and out going bus bar connection with overhauling of its spares including the CT/PT for smooth operation etc as required.
Maintenace of 3.3 KV Starter Panel of 400 KW HT motor (2 nos) - total 4 nos.
Dismantling of the old/burnt/defunt and providing fixing and commissioning of new auxillary contact 4 No + 4 NC as per the requirement
Dismantling of the old/burnt/defunt and providing fixing and commissioning of new hoding Coil 4 No + 4 NC as per the requirement
Dismantling of the old/burnt/defunt and providing fixing and commissioning of new Rectifier unit 110/220 V AC to DC single
Dismantling of the old/burnt/defunt and providing fixing and commissioning of new resistance 110 ohm
Dismantling of the old/burnt/defunt and providing fixing and commissioning of new auxillary 2 NO and 2 NC
Dismantling of the old/burnt/defunt and providing fixing and commissioning of new 160A, 3.3 KV, HT Fuse
Voltmeter /Ammeter96 sq mm
P T 3.3 KV/220 Volt,200 VA
Maintenance of the Panel HT including the wiring, fault analysis and changing the minor part if found damaged as required
Maintenace of the LT Control Panel (14 nos.) - Providing and fixing following capacity TP& N disconnector fuse switch unit inside the existing panels board with ISI marked, HRC Fuses including drilling holes in cubicie panel making connection etc as required
Maintenace of the LT Control Panel (14 nos.) - Providing and fixing following rating and breaking capacity and pole MCCB in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required.
100 Amp, 16 KA,TPMCCB
125 Amp, 16 KA,TPMCCB
150 Amp, 16 KA,TPMCCB
200 Amp, 16 KA,TPMCCB
250 Amp, 25 KA,TPMCCB
400 Amp, 35 KA,TPMCCB
800 Amp, 50 KA,TPMCCB
Maintenace of the LT Control Panel (14 nos.)
Dismantling of Old/burnt/defunt and providing, fixing and commissioning of digital Motor protection Relay, Control volatge 220V(CSMPM06-S)
Dismantling of old/burnt/defunt and fixing and commissing Switch disconnector fuse of different ratings
Maintenance of the Panel LT including the wiring, fault analysis and changing the minor part if found damaged as required
Protective Relay Testing (one time in a year)
Testing and calibration of protective Relay ( Over current/Earth Fault relay)
Testing and calibration of protective relays (Earth Leakage Relay)
Contact Resistance /Milivolt Drop test
Primary injection test
Replacement of old/defunct MCB
providing of MCB 16A 240V 2 Pole
providing of MCB 16A 240V 3 Pole
providing of MCB 32A 240V 3Pole
providing of MCB 63A 240V 3 Pole
providing of MCB 63A 240V 4 Pole
Providing of 1 sq mm mm Single Core HRFR PVC Insulated Industrial Grade Flexible Copper Cable 1100 Volt Confirming to IS 694
Providing of 1.5 sq mm mm Single Core HRFR PVC Insulated Industrial Grade Flexible Copper Cable 1100 Volt Confirming to IS 694
Providing of 2.5 sq mm mm Single Core HRFR PVC Insulated Industrial Grade Flexible Copper Cable 1100 Volt Confirming to IS 694
Maintenance of GOAB Switches
Minor maintenance of GOAB switches alongwith repairing/replacing of jumbers/insulators of overhead lines at CHP/RLS as when required basis
Total impact of GST for the purpose of CTC
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .