Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Tender Value
₹2.5 L
EMD Value
₹5,000
Closing Date
30 Oct 2025, 6:55 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Executive Engineer PWD RandB PROJECT DIVISION III
Office of the PWD RandB PROJECT DIVISION III JAMMU
Electric Repair/Renovation of Govt. Qtr. No. 2 B, 25 B and 9 B Gandhi Nagar, Jammu. CNO-366 NP
2025_PWDJK_293256_10
Short e-NIT No. 69 of 2025-2026 Dated 25-10-2025
Open Tender
Electrical Works
Percentage
15 days
JAMMU
Please refer Tender documents.
2 documents required · 2 mandatory
₹600
Executive Engineer PWD RandB PROJECT DIVISION III
₹5,000
Office of the PWD RandB PROJECT DIVISION III JAMMU
1 Nov 2025
25 Oct 2025
31 Oct 2025
25 Oct 2025
30 Oct 2025
25 Oct 2025
27 Oct 2025
Wiring for light point/ fan point / exhaust fan point/ call bell point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed PVC conduit, with modular switch, modular plate, suitable GI box earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc as required (Group-A)
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess including providing and fixing 6 pin 5/6 amps & 15/16 amps. modular socket outlet and 15/16 amps modular switch connection etc. as required.
1 x 2.5 sq. mm
1 x 4 sq. mm
Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. 25 mm
Supplying and fixing 5 amps to 32 amps rating 240/415 volts "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required of Approved Brand. Single pole upto 32 amp.
Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.
Suplying and fixing following modular switch/ socket on the existing modular plate & switch box inculding connection but excluding modular plate etc. as required. 5/6 amps switch
Suplying and fixing following modular switch/ socket on the existing modular plate & switch box inculding connection but excluding modular plate etc. as required. 3 pin 5/6 amp socket outlet
Suplying and fixing following modular switch/ socket on the existing modular plate & switch box inculding connection but excluding modular plate etc. as required. Bell push
Supplying and fixing PVCbatten/ angle holder including connections etc. as required.
"Supplying & fixing of following way single pole and netural, sheet steel, MCB distribution board, 240 volts, on surface/ recess complete with tinned copper busbar netural busbar, earth bar, din bar, inter connections, powder painted including earthing etc. as required.(But without MCB/RCCB/Isolater) " 12 way (Double door )
Suplying and fixing following modular switch/ socket on the existing modular plate & switch box inculding connection but excluding modular plate etc. as required. 6 pin 15/16 socket outlet
Supplying and fixing following rating 240/415 volts "C" curve, miniature circuit breaker suitable for inductive load of following poles Modular SPN/DP 32 A
Supplying and fixing following rating 240/415 volts "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. SPN 63 AMP
Providing and fitting of LED Bulbs 9W
Supplying and fixing of surface mounted 18/20 watt LED batten tube fiiting 4 feet long including connections etc as required warm/white
Supplying and fixing of 10 watt LED batten fitting 2 ft long including connections etc. warm/white
Providing and fixing ceiling panel light in false ceiling. 6" 12 Watt/ 15 watt
cove light strip
Supply, Installation , Commissioning and Testing of Hot & Cold Split Type air Conditioning Unit, Inverter Heat Pump type Heating and cooling Function Opertation -10deg C to 54deg C ( Heating range: -10 to 24 deg c, Cooling range: 20 to 54 degc) in 3 STAR Rating, with Dew Clean Technology (auto cleans the coil of inddor units), Stablizer inside ( 130 v to 285 v) operation,(Triple Display-Power consumption display in %,Automatic error code display & set/room temperature display), Power airflow duel flaps,Air Filteration -PM1.0,Co2 filteration,Anti corrosion- Blue fin coating Cooling capacity at 43 degc is 100%, ISEER - 4.39 & above, Air throw 52 ft ( 1.5 ton & 1.8 ton machines only),3D air flow,Min IDU sound level- 32 (dBA),(Warranty- Compressor-10 years,PCB-5 year,Total system warray-1 year) with Interconnecting copper pipe of 3 metres, Control cable of three metres of the following Capacities. 1.5 Ton with Cooling Capacity of 5.0KW Cooling/Heating
Supplying and fixing of twin core aluminium cable all along the wall surface unarmoured. 25 sq.mm
Providing and fixing of up down lights three way lights
Providing and fixing Fancy decorative light complete with 9 watt LED Bulbs.
stage.html
html • 0.02 MB
cancelled_1.pdf
pdf • 0.66 MB
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.85 MB
BOQ_947383.xls
BOQ • 0.34 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .