Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.3 CrAccepted-AOC | ₹1.3 Cr | L1 | Accepted-AOC L1 Bidder, Accepted |
| 2 | L2₹1.3 Cr+₹55,525.45 (0.42%)Rejected-AOC | ₹1.3 Cr+₹55,525.45 (0.42%) | L2 | Rejected-AOC L2 Bidder, Rejected |
Tender Value
₹1.3 Cr
EMD Value
₹1.4 L
Closing Date
27 Oct 2023, 3:00 pmClosed
Project Director, DRDA, Tiruppur
DRDA Tiruppur, District Collectorate, Tiruppur.
Upgradation/strengthening of road including 5 years of routine maintenance after completion under Package No. 10/NABARD-RIDF-XXIX/2023-24 in Kundadam Block of Tiruppur District.
2023_RDTN_380143_3
DIPR/5562/Tender/2023
Open Tender
Civil Works - Roads
Item Rate
180 days
Tiruppur
Please refer Tender documents.
4 documents required · 4 mandatory
₹0
₹1.4 L
DRDA, Tiruppur
6 Feb 2024
18 Oct 2023
27 Oct 2023
18 Oct 2023
27 Oct 2023
18 Oct 2023
25 Oct 2023
Amount
Strengthening to the road from Vanavarayanallur Karaipudhur road to Sellandiamman koil Km 0/0-3/50 (Working reach km 0/0-3/430) R 122) Part A - Construction Work Clearing the light /scrub jungle by uprooting including all cutting charges and disposing of the products and clearing as directed by departmental officers including all incidental charges etc. complete. MORD Specification 111, 112, 201
Earth work excavation and depositing on back with an initial of 10m and lift 2m in sand, silt or other loose soil, wet sand or silt not under water, light black cotton soil, sandy loam and ordinary soil including excavated earth etc., as per SS 20 B including laying and spreading in layers of 250 mm loose thick each, sectioning , watering and compacting by Power roller to achieve the required Proctor density at 100% compaction at optimum moisture content as determined in occurrence with complete as per MoRD 111, 112, 202, 900, 301, 304
Providing and laying Gravel including cost and conveyance of gravel from approved sources to work site including labour for spreading , watering and compacting by power roller to achieve the required protect density at 100% compaction at optimum moisture content and hire & fuel charges for power roller, water sprinkler and all other incidental charges such as traffic barricading and providing danger lights etc., complete. MORD Specification 111, 112, 401, 900 Km 0/0 - 1/0
Picking of Old matelled / B T surface up to 10 cm thick and disposal of scarified material with a lift upto 3m and lead upto 1000 m as per technical specification clause 301.4 as directed by the departmental officers
Wet Mix Macadam Providing, laying, spreading and compacting graded stone aggregate to wet mix macadam specification including premixing the material with water at OMC in mechanical mixer (Pug Mill), carriage of mixed material by tipper to site, laying in uniform layers in subbase/base course on a well prepared sub-base and compacting with smooth wheel roller of 80 to 100kN weight to achieve the desired density including lighting, barricading and maintenance of diversion, etc as per Tables 400.11 & 400.12 and Technical Specification Clause 406.
Providing and applying primer coat with bitumen emulsion (SS-1) on prepared surface of granular base including cleaning of road surface and spraying primer at the rate of 0.70 kg/sqm using mechanical means as per Technical Specification Clause 502
Providing and applying tack coat with Bitumen emulsion (RS-1) using emulsion pressure distributor at the rate of 0.25 kg per sqm on the prepared granular surface treated with Primer cleaned with Hydraulic broom as per Technical Specification Clause 503.4
Bituminous Concrete (BC) ProvidingBC 25 mm Thick (GradeII)Using VG30 Bitumen Providing and laying Bituminous Concrete to 25 mm thick using 0.13 cum of 19.00- 9.50mm, 0.17 cum of 9.50-2.36mm and 0.26 cum of 2.36 and below with 47.28kgs of VG30 bitumen and 3.02Kgs of Waste Plastic for premixing per 10sqm including cost and conveyance of all materials to CMP site, heating the bitumen and aggregate to required temperature and mixing them in required temperature in central hot mix plant 20-30 ton capacity, conveying the mix by tipper trucks to paver site, spreading the mix to uniform thickness of 30mm with mechanical paver to the specified grades and cross sections and consolidated by 8-10 tonne Vibratory to the required density etc., including labour for attending to paver to site etc., including hire charges and fuel charges for 20-30 t CMP with bitumen boiler, tipper trucks, Paver Finisher, Vibratory roller and all other tools and plant required, including fuel and all other incidental charges etc., complete as per specification using CMP as per clause 507 of MORTH Rev-5
Reinforced cement concrete M15 grade kilometre stone of standard design (size 1.65m x 0.45m x 0.15m) as per IRC:8 fixing in position including painting and printing, etc as per drawing and Technical Specification Clause 1703 Ordinary Kilometer Stone (Precast) specification Clauses 1703
Reinforced cement concrete M15 grade Hectometre stone of standard design (size 0.90m x 0.15m x 0.15m) as per IRC:8 fixing in position including painting and printing, etc as per drawing and Technical Specification Clause 1703
RUMBLE STRIPS COVERED WITH BITUMINOUS SURFACE Provision of 1 nos. rumble strips covered with premix bituminous carpet, 15-20 mm high at centre, 250 mm wide placed at 1 m centre-to-centre at approved locations to control speed, marked with white strips of road marking.
Providing and fixing of typical PMGSY informatory sign board/ CIB with Logo and Maintenance board as per detailed specifications and drawing will be communicated by the Direcorate of Rural Development and Panchayat Raj
Providing and fixing of retro -reflectorised Cautionary,mandatory and information sign as per IRC: 67 made of encapsulated lens type reflective sheeting vide clause 1701.2.3 fixed over aluminium sheeting,1.5mm thick supported on a mild steel angle iron post 75mmX75mmx6mm firmly fixed to the ground by means of properly designed foundation with M15 grade cement concrete 450mmx450mmX600mm,600mm below ground level as per drawings and Technical Specification Clause 801 - 600mm Equilateral triangle or Size as per IRC :67-2001
ROAD MARKING WITH HOT APPLIED THERMOPLASTIC COMPOUND WITH REFLECTORISING GLASS BEADS ON BITUMINOUS SURFACE Providing and Laying of hot applied Thermoplastic compound 2.5 mm thick including reflectorising glass beads @250 gms per sqm area, thickness of 2.5 mm is exclusive of surface applied glass breads as per IRC 35. The Finished surface to be level, uniform and free from streaks and holes etc complete as per MORTH specification No :803
Construction of Pipe culvert at ch 2430 m Earth work Excavation for Foundation in all soils and Sub Soil to full depth as may be directed except in hard rock requiring blasting but inclusive of shoring strutting and requiring the sides of foundation.Clause 305.1
Cement concrete 1 : 4 : 8 mix using 40mm HBG metal for foundation including watering wherever necessary and laid in layers of not more than 15cm thick., compacting etc., complete complying with standard specifications and as directed.Clause 802, 803, 1202 & 1203
Supplying and erecting centering shuttering including necessary supports for plane surface in foundation and basement and in all floors for R C C column footing column plinth beam, beams, roof slabs, staircase steps, bed blocks, critical pier etc using mild steel sheets of size 90 x 60 cm and 10 guage stiffened, welded with mild steel angles of size 25mmx25mmx3mm for boarding laid over silver oak (country wood) scantlings of size 10cm x 6.5cm spaced of about 90cm centre to centre and supported by casurina props of 10cm to 13cm dia spaced at 75cm centre to centre complete complying with standard specifications and as directed by departmental officers including conveyance of all materials to site and proper centering etc complete.
Cement concrete 1 : 3 : 6 mix using 20mm HBG metal for foundation including watering wherever necessary and laid in layers of not more than 15cm thick., compacting etc., complete complying with standard specifications and as directed.Clause 802, 803, 1202 & 1203
Supplying and fixing of RCC hume Pipes with suitable collars including cost of pipes and labour charges etc, complete.
PART (B) Maintenance Routine Maintenance After completion of construction works Maintenanace I year
Maintenanace II year
Maintenanace III year
Maintenanace IV year
Maintenanace V year
GST Amount for providing Service to Government Contract Works for the above Construction & Maintenance Works. { GST Amount is the Total GST Amount for overall quoted amount (Both Construction and Maintenance) above this row in column "BB" for all works in this package} (Refer Clause 13.2 & 13.3 of Section 2 of Instruction to Bidders (ITB) of SBD)
malaiammanconstruction
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.05 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .