Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹22.1 LAccepted-AOC MEHEM ROAD NEAR TVS BIKE AGENCY GOHANA SONIPAT HARYANA 131301 ON MEHAM ROAD NEAR TVS BIKE AGENCY GOHANA 131301 | SONIPAT | HARYANA | 131301 | L1 | Accepted-AOC Accepted | |
| 2 | L2₹23.5 L+₹1.4 L (6.53%)Rejected-AOC | L2 | Rejected-AOC Rejected | |
| 3 | Rejected-Technical VILLAGE DUMERKHA KALAN POST OFFICE DUMERKHA KALAN TEHSIL UCHANA DISTRICT JIND 126115 HARYANA | DUMERKHA KALAN | JIND | HARYANA | 126115 | - | Rejected-Technical rejected | |
| 4 | Rejected-Technical | - | Rejected-Technical rejected | |
| 5 | Rejected-Technical | - | Rejected-Technical rejected |
Tender Value
₹24.7 L
EMD Value
₹49,480
Closing Date
5 Aug 2021, 5:00 pmClosed
Executive Engineer
Electrical Division PWD BnR Rohtak
DNIT for the work Special Repair to E.I. in Civil Hospital at Narwana in Jind Distt.
2021_HRY_180032_1
PWD/Electrical/117364
Open Tender
Electrical Works
Item-rate/Agreement basic
60 days
Jind
Please refer to tender documents as per DNIT conditions.
3 documents required · 3 mandatory
₹1,000
₹49,480
Yes
3 Nov 2021
17 Jul 2021
6 Aug 2021
17 Jul 2021
5 Aug 2021
17 Jul 2021
Amount
23.5 Copper Wiring in Existing PVC/MS Conduit Pipe Surface/Recessed
23.5.1 Wiring only in 1.5 sqmm PVC insulated copper conductor cable for LIGHT/FAN/Call bell point in existing conduit pipe and MS boxes including cost of Bakelite cover for MS box, switch, wall socket, ceiling rose/connector etc.
23.5.1.2 Group B
23.5.3 Wiring only in existing conduit and MS Box for Light/Fan/call bell point in 1.5 sqmm FRLS PVC insulated copper conductor cable , without separate
23.5.1.2 Group B
23.5.4 Wiring in existing conduit and MS box for 3-pin Samp. Plug point by using 2 no 1.5 sqmm FRLS copper wire and 1 no 1.5 Sqmm FRLS copper wire , including providing 1 no 5/6 Amp 3/5 pin socket and 1 no 5/6 Amp switch etc complete as required
23.5.4.2 Group B
23.5.5 Wiring in existing conduit system for 3-pin 15amp. Plug point by using 2 no 4 sqmm FRLS copper wire and 1 no 4 Sqmm FRLS copper wire for earthling , including providing 1 no 15/16 Amp 3/6 pin socket and 1 no 15/16 Amp switch etc complete as required
23.5.5.2 Group B
23.5.6 Wiring main and sub mains in two single core for phase and neutral wire and one single core for earth wire PVC insulated Copper conductor cable 1100 Volts grade in existing MS/PVC Conduit etc as required.
23.5.6.5 1 run of Size 10 Sqmm(1/3.50 mm).
23.5.6.6 2 run of Size 1.50 Sqmm(1/1.40mm)
23.5.6.8 2 run of Size 4 Sqmm(1/2.24mm)
23.7.6 Supply and erection of PVC CONDUIT ISI marked (Medium) recessed in wall/ceiling etc. including the cost of PVC bends, inspection boxes, iron hooks and cement concrete etc. complete in all respect up to the entire satisfaction of Engineer-in-Charge of work.
23.7.6.1 PVC pipe of 20 mm dia
23.7.6.2 PVC pipe of 25 mm dia
23.8 Fitting and Accessories
23.8.1 Providing and fixing Piano type accessories of approved make in existing box and Bakelite sheet including fixing and making necessary connections, complete in all respect.
23.8.1.1 Switch 5 amp. on existing sheet.
23.8.1.2 Wall socket 5 amp on existing sheet.
23.8.1.6 Call bell 220/230 volts musical type
23.8.1.9 Bell push
23.8.1.12 Bakelite angle/straight button holder large size.
23.8.1.13 Socket size rotary step type Electronic regulator for A.C. ceiling fan
23.9 Erection of exhaust fan in existing opening ,complete with necessary earthling of fan including carriage from PWD store to the site of work.
23.12 Providing and fixing outdoor type ply of 12 mm thick frame suitable for exhaust fan upto 450 mm sweep etc. complete as required
23.22 Moulded case Circuit breakers.
23.22 (I) Supply and erection of moulded case circuit single/4 pole on existing wall /pedestal/panel including bounding to earth and making necessary connection required to complete the job in all respect upto entire satisfaction of engineer in charge of the work.
23.22 1 (iii) Triple pole MCCB 16 to 100 Amp. 25 KA
23.22 1 (v) TRIPLE POLE MCCB 200 to 250 Amp, 25 KA
23.22 1 (ix) 4 pole MCCB 6 amp to 100 amp 25 KA
23.22 1 (xii) 4 pole MCCB 300 to 400 amp , 50 KA
23.22 (2) MCCB Enclosure made of Sheet Steel suitable for mounting MCCB of following ratings
23.22.2.1 MCCB up to 125 A FP
23.22.4 Supply and erection of double door sheet steel enclosure distribution board suitable for MCBS and ELCBS etc. recessed in wall including bonding to earth with all labour and material required to complete the job in all respect up to the entire satisfaction of the Engineer-in-Charge of the work.
23.22.4.5 TPN DB Horizontal type Double Door 4 way ( 8 incoming and 3 phase“4 outgoing)
23.22.4.7 TPN DB Horizontal type Double Door 8 way ( 8 incoming 3 phase* 8 outgoing)
23.22 (5) Supply and erection of miniature circuit Breaker 240/415 V in the existing distribution board including making necessary connections:-
23.22.5.1 6 amp. to 32 amp Single Pole
23.22.5.8 40 amp to 63 amp. MCB's FOUR POLE
23.24 MS STAND, BUS BAR CHAMBER AND PANELS
23.24 (1) Supply and erection of M.S. angle iron frame duly welded for housing M.S. sheet & main switches etc. on it, fixed on wall by means of suitable size of rag bolts with cement concrete, duly painted with three coats of approved paint including one coat of red oxide.
23.24.3 Supply and erection of metal clad bus bar chamber made from 1.6 mm thickM.S. sheet and fixing with rag bolts on wall or on existing pedestal/angle iron frame including bonding, detachable top and bottom including painting and necessary connection etc. (Aluminium bars).
23.24.3.2 100 amp 4 bars of 55 cm each (cross section 25 mm x6 mm) chamber over all size 60 cm x 45 cm x 18cm
24.1 EARTHING AND LIGHTENING ARRESTOR
24.1.3 Earthing with G.I. earth plate 600 mmx 600 mm x 6 mm thick including accessories and providing masonry enclosures with cover plate having locking arrangement and watering pipe etc. (but without charcoal or coke and salt) complete as required.
24.1.4 Earthing with tinned copper earth plate 600mmx600mmx3mm thick including accessories and providing masonry enclosures with cover plate having locking arrangement and watering pipe etc. (but without charcoal or coke and salt) etc. complete as required.
24.1.5 Extra for charcoal or coke and salt for G.I. Plate or copper plate earth electrode
24.1.7 Supplying and laying 25mm x 3 mm G.I. strip in 40 mm dia,GI pipe as/from earth electrode including soldering etc. as required
24.1.9 Providing and fixing 25 mm x5 mm copper strip in 40 mm dia G.I. pipe from earth electrode as required.
24.1.14 Supply and erection of 20mm x 3 mm thick GI, tape fixed with suitable G.I. staples of same size.
NS-1 Supply & erection of M.S. Box made of size d 8" x 10" x 4" (20cm x 25cm) and 10cm deep made one of 1.6mm thick MS covered with 5 mm thick bakelite sheet for fixing of 4 Nos. socket ans switch of 6 Amp. and one no. socket and switch of 15 amp. including fixing of one no. fuse unit and indicator of approved make. The MS box is recessed in wall including cost of necessary cement sand and mixture required to complete the job in all respect with cost of necessary labour charges for fixing the bakelite sheet and complete the job in all respect upto the entire satisfaciton of Engineer-in-charge of the work.
NS-2 Supply & erection of undergroun cable loose in existing pipe or trenches complete in all respect upto the entire satisfaction of Engineer in charge of the work.
35 Sqmm 3.5 core
50 Sqmm 3.5 core
70 Sqmm 3.5 core
95 Sqmm 3.5 core
Balraj Singh Contractor
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .