Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹20.8 LAccepted-AOC | L1 | Accepted-AOC L1 | |
| 2 | L2₹24.7 L+₹3.8 L (18.4%)Rejected-Finance H NO 177 GOVINDPURA SATWARI JAMMU CANTT 180003 J K | JAMMU | JAMMU AND KASHMIR | 180003 | L2 | Rejected-Finance Other than L1 | |
| 3 | L3₹25.2 L+₹4.3 L (20.7%)Rejected-Finance 201 GANAPATI SANKUL AGASHIVNAGAR MALKAPUR KARAD SATARA MAHARASHTRA 415539 | SATARA | MAHARASHTRA | 415539 | L3 | Rejected-Finance Other than L1 | |
| 4 | L4₹25.2 L+₹4.4 L (21.0%)Rejected-Finance | L4 | Rejected-Finance Other than L1 | |
| 5 | L5₹30.7 L+₹9.9 L (47.4%)Rejected-Finance | L5 | Rejected-Finance Other than L1 |
Tender Value
₹40 L
EMD Value
₹80,000
Closing Date
10 Feb 2022, 6:00 pmClosed
GE Satwari
GE Satwari Jammu
REPAIR/REPLACEMENT OF WIRING DBs SUBMAIN ETC OF CERTAIN OTM BUILDINGS UNDER AGE E/M AND AGE E/M(MH) OF GE SATWARI
2022_MES_501679_1
GEJM-66/2021-22
Open Tender
Civil Works
Item Rate
210 days
Satwari
D Class cat b i
9 documents required · 9 mandatory
₹500
GE Satwari
₹80,000
Yes
26 May 2022
14 Jan 2022
12 Feb 2022
14 Jan 2022
10 Feb 2022
29 Jan 2022
Amount
"Receiving/recording complaints lodged by occupants of area 166 MH and Raipur Satwari and Y Stn under GE Satwari of internal electrification nature, rectification of the fault as per the complaint lodged by the user or as given by MES onward KWH meter in respect of main distribution board having switch fuses, MCB distribution board in sheet metal enclosure, point wiring, fixture for light/ Fan/bell/light or power sockets complete repairs to the extent by removing connections from the system, removing faults in wires, batten, conduit, sunk boxes, junction boxes, main switches, MCBs/DBs utility light fittings, FTL light fitting any wattage lamp, holders, AC ceiling/exhaust fans and other connected fixtures of the internal electrification including providing of petty stores such as wires of appropriate size and conductor matching to existing one upto the length of 1 mtr including insulation tape, screws, nuts as required to rectify the fault with regard to the complaint lodged and refixing of fittings, fixture to their position as dismantled complete all as directed at site to the entire satisfaction of Engineer-in-Charge/users.
NOTE: (i) The new items provided shall be measured and paid for separately under relevant items of Sch ‘A’. (ii) Rate of Other items like screws, nuts, insulation tape, copper wire of diferent size upto 01 mtr length, Modular sheet cover etc are covered under Item No. 1 (iii) If contractor fails to attend the complaints within 48 hrs of receipt of the same from MES a recovery of Rs 300.00 shall be made per complain per 24 Hrs.
Supply only switch piano flush button single pole one way, 6 Amps, 240 V
Supply only bell push piano flush type 6 amps , 240 V.
Supply only buzzer door bell, AC 230 volts Single Phase.
Supply only socket outlet 2-in-1 5 pin, 6 Amps flush type complete all as specified and as directed. .
Supply only Switch socket combination 2-in-1 5 pin 6 Amps flush type complete all as specified and as directed.
Supply only Switch piano flush button single pole one way, 16 Amps, 230/240 V
Supply only Socket outlet 2-in-1 5 pin, 6 & 16 Amps flush type complete all as specified and as directed.
Supply only Switch socket combination 5 in 1, 6A and 16 Amps flush type universal controlled by one switch.
Supply only Fan regulator socket type stepped type (electronic ) for 1200/1400mm sweep AC ceiling fan.
Supply only modular type switch, one way 6 Amps , 1 module complete all as specified and directed. Make: As per existing
Supply only modular type socket 5 pin, 6 Amps combined 2 module complete all as specified and directed. Make: As per existing
Supply only modular type socket 5 pin, 6 /16 Amps combined 2 module complete all as specified and directed. Make: As per existing
Supply only modular type switch, one way 16 Amps, 1 module complete all as specified and directed. Make: As per existing
Taking down carefully aluminium conductor point wiring (light, fan, light socket, power socket) complete fitting such as swithes, sockets, lamp holder, utility light fitting, fan regulator etc and removing materials from sites and making good distrubed surface of walls and roofs complete all as specified and as directed.
Taking down carefully unserviceable sub main wiring any type and size etc.
Taking down unserviceable DBs any type / size carefully disconnecting and making good disturbed surfaces complete all as directed.
Taking down unserviceable MCB SP/SPN/Isolator/MCCB of any rating & size.
M&L for complete point wiring with 1.5 Sqmm single core multi stranded copper conductor FRLS insulated and sheathed heavy duty cable in colour code including continuous earth wire with cable of size 1.5 sqmm multistranded copper conductor FRLS insulated drawn in and including concealed PVC rigid conduit medium grade ISI marked terminated into GI/pressed steel modular terminal boxes including modular switch cover IS marked for mounting modular switches, sockets, fan regulators etc complete all as specified and as directed for the following :- Make of Cable: Polycab, Finolex, RR kabel
One light/fan point controlled by one, one way switch 6 Amp complete
One light point controlled by 2 Nos 6 Amp Two way switch
One additional light point on same switch board
One 3 pin modular socket outlet 6 amp independent board
One 3 pin modular socket outlet 6 amp on same board
One 3 pin 6 Amps modular socket outlet independent but below the switch board of light points in the same vertical plane
One bell/ buzzer point controlled by one push button on same board with other switches or independent with cable 1.5 sqmm size complete all as specified and directed.
Ditto all as per Srl item No 20 above but for one 3 pin modular socket outlet 15/16 Amps independent with cable of size 2.5 Sqmm for point wiring and 2.5 sqmm as in continuous earth wire.
S&F switch modular one way 06 Amp,1 module all as specified and directed.
S&F switch modular two way 06 Amp,1 module all as specified and directed.
S&F switch modular one way 16 Amp,1 module all as specified and directed.
S&F Modular socket 6A-2/3 Pin 2 module 230V AC all as specified and directed.
S&F Modular socket 6A/16A-3 Pin 2 module 230V AC all as specified and directed.
S&F modular bell push type one way 6 Amp 1 module all as specified and directed.
S&F modular type fan regulator 2 Module all as specified and directed.
M&L for point wiring with 1.5 Sqmm single core multi stranded copper conductor FRLS insulated and unsheathed heavy duty cable in colour code including continuous earth wire with cable of size 1.5 sqmm multi stranded copper conductor FRLS insulated drawn in existing concealed PVC/MS rigid conduit of any size terminated in exisitng CI/pressed steel terminal boxes including 3.00 mm thick hylam marked, laminated sheet cover for mounting switches, sockets, fan regulators etc complete all as specified and as directed for the following :- Make of Cable: Polycab, Finolex, RR kabel
One light/fan point controlled by one, one way switch 6 Amp complete
One additional light point on same switch board
One 3 pin modular socket outlet 6 amp independent board
One 3 pin modular socket outlet 6 amp on same board
One 3 pin 6 Amps modular socket outlet independent but below the switch board of light points in the same vertical plane,
One bell/ buzzer point controlled by one push button on same board with other switches or independent with cable 1.5 sqmm size complete all as specified and directed.
Ditto all as per Srl item No 36 above but for one 3 pin modular socket outlet 15/16 Amps independent with cable of size 2.5 Sqmm for point wiring and 2.5 sqmm as in continuous earth wire.
S&F switch piano flush button polycarbonate single pole one way 6 Amps, 240 V.
S & F switch piano flush button polycarbonate single pole one way 16 Amps, 240 V.
S & F bell push piano flush type polycarbonate 6 amps, 240 V.
Supply and fixing bell Ding Dong AC 230 volts Single Phase all as specified and directed.
S&F socket outlet 2-in-1 5 pin, 6 Amps flush type polycarbonate complete all as specified and directed.
S&F socket outlet 2-in-1 5 pin, 6 & 16 Amps flush type polycarbonate complete all as specified and directed.
Supply and fix Fan regulator socket type stepped type (electronic ) polycarbonate for AC ceiling fan all as specified and directed.
Supply and fixing ceiling rose surface, backelite, three terminal, 240 volts complete all as specified and directed.
Supply and fixing lamp holder, Polycarbonate type with back plate suitable for batten fittings all as specified and as directed.
Supply and fixing lamp holder pendant/angle type insulated body with back plate and including 7 watts LED bulb all as directed and specified by Engineer-in-Charge.
Supply and fixing LED tube light fitting 18-20 Watts, polycarbonate with superior aesthetic and heat dissipation capability suitable for G-13 base tube lights base luminaire, 18-20 watt LED wattage with colour temp of 6000K, 1800-2000 lumens and with surge arrestor complete in all respect suitable for installation in existing tube light with G13 lamp holders to give glare free light 18/20 watt.
Supply and fixing LED tube rod light 18/20 watts T -8 with necessary fixing arrangement etc complete all as specifed and directed by Engineer-in-charge.
Supply and fixing with New LED T-5 Fitting 20 watts with necessary braket, clamps, incl. bolts, nuts & washers for fixing arrangement etc complete all as specifed and directed by Engineer-in-charge.
Supply and fixing with LED light fitting 10 watts with LED tube rod, ready to use pack with necessary braket,clamps ,incl. bolts, nuts & washers for fixing arrangement etc complete all as specifed and directed by Engineer-in-charge.
Supply and fixing of energy saving new generation 10W LED IP65 bulk head luminaire with opal diffuser complete all as specified and directed.
S&F LED luminaire 600 mm X 600 mm 35/36 watt, 220 V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver & LED lamp suitable for roof ceiling including connecting up with three core flexible copper conductor cases of suitable size complete.
S&F MCB SPN complete 32 Amp with rupturing capacity 10 KA 'C' series, Complete all as specified and directed.
S&F MCB SPN complete 40-63 Amp with rupturing capacity 10 KA 'C' series, Complete all as specified and directed.
Supply and fixing MCB single pole 6 to 32 Amp with rupturing capacity 10 KA 'C' series complete all as specified and directed.
S&F MCB 4 pole complete 40-100 Amp with rupturing capacity 10 KA 'C' series complete all as specified and directed.
Supply and fixing round shape 12 watt 220 Volts AC recessed type with high efficiency PMMA diffuser sift glare free light complete with drivers, holders, LED lamp suitable for roof ceilingincluding connecting up with three core flexible copper conductor cases of suitable size complete
Supply and fixing round shape 15 watt 220 Volts AC recessed type with high efficiency PMMA diffuser soft glare free light complete with drivers, holders, LED lamp suitable for roof ceiling including connecting up with three core flexible copper conductor cases of suitable size complete
M&L for replacement of RCBO, double pole with sensitivity 100 mA of cap 63 Amp as per existing make all as specified.
S&F Vertical Distribution Board (TP&N) 4 way double door suitable for MCCB 3/4 pole of cap upto 125 Amp as incomer and out going MCBs SP and should be IP 54 protected with Copper Bus Bars, Neutral Links, Earthing bar all as specified and directed.
S&F MCCB four pole 100 Amp, 16 KA, 415 volts with adjustable thermal settings all as spcified and ditected. Note: TPN DB and MCCB should be of same make.
Supply & fixing of Vertical Distribution Board MCB VTPN 4 way double door suitable for and including MCB four pole as incomer and out going MCBs and should be IP 43 protected with Copper BusBars, Neutral Links, Earthing bar all as specified and directed. Note:- (i). MCBs shall be measured and paid separately. (iii) TPN DB and MCB should be of same make.
S&F Distribution Board (SPN) double door 12 Way and should be IP 54 protected with Copper Bus bar, Earth Bar, neutral Bar all as specified and directed.
Ditto all as per item No 70 but 8 Way double door
Ditto all as per item No 70 but 4 Way double door
S&F distribution board single door two way without bus bar complete suitable for mounting MCB all as specified and directed.
S&F single pole and neutral enclosure with a two pin and earth plug and socket complete with one double pole MCB 20 Amp all as specified and directed.
S&F bus bar chamber TPN type with aluminium bus bar IP 42 protection 100 Amp three pole and neutral enclosure including necessary electrical connection all as specified and directed.
S&F sub main wiring with single core cable 4 x 10 sq mm FRLS insulated unsheathed stranded copper conductor cable 1100 Volts grade in rigid PVC conduit (Concealed) medium grade alongwith 1x10 Sq mm FRLS insulated unheathed stranded copper conductor cable as earth wire connected with main earth dolly including chiseling, cutting & making good to match with the existing surface complete all as specified and directed. Make of Cable: Polycab, Finolex, RR kabel
S&F sub main wiring with single core cable 2 x 6 sq mm FRLS insulated Unsheathed stranded copper conductor cable 1100 Volts grade in rigid PVC conduit (Concealed) medium grade alongwith 1x6 Sq mm FRLS insulated unheathed copper conductor cable as earth wire connected with main earth dolly including chiseling, cutting & making good to match with the existing surface complete all as specified and directed. Make of Cable: Polycab, Finolex, RR kabel
Ditto all per Item No 77 but of size 2 x 4 Sqmm with earth wire 1 x 4 Sqmm drawn through existing PVC/steel Surface/Concealed conduit all as specified and directed.
S&F 1100 volt grade heavy duty cable PVC insulated multistranded aluminum conductor served with PVC tape and over all PVC sheathed in service connections suspended by insulating hangers not more than 1 mtr apart including 4mm dia GI suspension wire one twin core cable flat or circular of size 10 Sqmm incl taking down old service connection and removing from the side complete all as specified and as directed. Make:- Havell's/CCI/Poly Cab/Finolex
Ditto all as per item No 79 above but 16 sqmm twin core service wire.
Supply and fixing ceiling fan complete with blade, down rods, electronic regulator and accessories, 230 V, 1200 mm sweep, Min air delivery 210 CFM with service value 6.00 BEE. Five star rated with brushless direct current motor (BLDC) and connected from ceiling rose/ connector with & including suitable size flexible copper conductor PVC insulated sheathed cord, complete.
Supply and fix 5 mm thick acrylic LED light in english alphabet letter and logos to framing lighting sign board in colours on ACP including wiring and necessary connection as per direction of Engr-in-Charge.
Supply and fix Aluminium composite panel (ACP) of 5 mm thickness of required colour fixed on MS framed structure for installation of sign board letter complete all as directed by Engr-in-Charge.
M&L for steel work in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes confirming to IS 1161 -1979 grade St-240 all as specifed and directed.
S&F Supreme Wired Call Bell System with High Glow Digital Numeric Display and Inbuilt Bell for 14 Users with recognising system all as specified. ASIN : B01MUZJTDD, Item model number : SIPCSD14 Manufacturer : SUPREME INTERNATIONAL or its equivalent in Relison
M&L for Cement concrete Type B2 1:2:4 (40 mm graded ) in foundations, filling and mass concrete complete all as specified.
Supply and fix Electronic Meter with digital display with temper proof cover single phase 10-60 Amp IP-54 protection IS 13779 class-1 50 Hz 230 V including necessary electric connection in existing circuit all as specified and directed. Make: L&T / HPL/ Secure
Taking down the defective ceiling fan of any sweep and make after disconnecting electrically & mechanically and transporting to the work shop dismantling, examine & carry out the repairs as required and brought back to site, re-fixing, testing in all respect for smooth running and comprising of the following:- (a) Servicing/overhauling the ceiling fan by thoroughly cleaning the bearing, shaft, stator, rotor & applying the lubricant / grease to the bearing including applying one coat of super enameled varnish over the winding to improve the insulation value complete.
(b) Re-winding the burnt/short circuited winding with same guage supper enameled copper wire to maintain speed at load.
(c) Painting of ceiling fan by applying one coats of synthetic enamel paint after preparation of surface complete.
Taking down the repairable exhaust fan of 300 MM sweep, any make, single phase, 230 volts, 50 hz, AC after disconnecting electrically and mechanically and transporting to the work shop dismantling, examine & carry out the repairs as required and brought back to site, re-fixing, testing in all respect for smooth running and comprising of the following:- (a) Servicing/overhauling the exhuast fan by thoroughly clelaning the bearing, shaft, stator, rotor & applying the lubricant / grease to the bearing including applying one coat of super enameled varnish over the winding to improve the resistance value.
(b) Re-winding the burnt/shourt circuited winding with same cauge supper enameled copper wire to maintain speed at load.
(c) Painting of Exhaust fan by applying one coat of synthetic enamel paint after preparation of surface complete.
M & L for galvanised steel earthing complete with 60 cm x 60 cm x 6 mm thick galvanised steel earth electrode and 04 mm dia galvanised earth lead wire burried directly in ground (earth pit not less than 2.25 mtr below ground level) with top edge of the plate not less than 1.5 mtr below ground level connected to earth lead 4.0 mm dia GI wire protected by 15 mm bore light grade galvanised iron pipe and other and connected to test point as directed including funnel with watering pipe 20 mm bore light grade galvanised iron wire mesh, charcoal and common salt in alternater of 15 cm complete thickness all around the GI plate electrode complete with earth pit PCC 1:3:6 type CI and RCC cover and necesary excavation and earth work in hard/dense soil and disposal of spoil to a distance not exc 50 mtr and necessary testing complete all as shown in electorical plate No 03 connected to earthing test point including following elements/works all as specified.
M/S A TO Z ENGINEERS
Prakash Trading Corporation
Harsh Electricals
LAL CONSTRUCTIONS
M/S S K Electricals Regd
VIDHATA ELECTRICALS
bamral builder
M/S ANIL MAHAJAN
stage.html
html • 0.06 MB
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .