Loading…
Loading…
Tender Value
₹50 L
EMD Value
₹1 L
Closing Date
27 Aug 2026, 6:00 pm2d left
GE LALGARH JATTAN
GE LALGARH JATTAN - 335037, RAJASTHAN
REPAIR, REPLACEMENT OF FLAMEPROOF FITTINGS, FIRE FIGHTING SYSTEM AND CONNECTED WORKS AND REPAIR, MAINT OF LIGHTENING PROTECTION SYSTEM OF VARIOUS SHEDS AND OTHER BLDGS AT LGJ MIL STN UNDER GE LALGARH JATTAN
2026_MES_783534_1
8937-26/GE/2026-27
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE LALGARH JATTAN
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE LALGARH JATTAN
₹1 L
Yes
8 Aug 2026
8 Aug 2026
29 Aug 2026
8 Aug 2026
27 Aug 2026
22 Aug 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | M&L for flame proof point wiring for one light point / Exhaust fan point with 2.50 Sqmm FRLS PVC insulated copper conductor cable and 2.50 sq mm as earth wire in and including ERW steel rigid heavy duty conduit duly painted flame proof black enamelled of suitable size on wall complete with all fittings such as elbows, bends, connectors, sadles, clamps etc and other accessories complete all as specified and directed by Engr-in- Charge.
Note :- 1. Taking down of old point wiring is incuded in this item.
2.Junction Box will be measured and paid seperatly. | 100 | per point | - | - |
| 2 | Supply and fixing in replacement CMRI certified flameproof/weather proof 1X40 Watt LED bulkhead fitting wall/surface mounted or recess in wall/roof, well glass luminaire suitable for RF LED lamp, recommended for Gas/Vapour group of IIA & IIB and zone 1 & 2, IP65 protection, Epoxy finish LM6 die cast aluminium housing with heat resistant toughened glass, including inbuilt electronic driver, 2 kv surge protection, internally pre-wired, LED lamp, connector block etc complete with all other accessories and including making electric connection connecting with twin core twisted flexible copper conductor cable (flame proof) and making good disturbed surfaces of walls/ceiling etc. by using CM (1:3) including taking down old unserviceable light fitting any type complete all as specified and as directed by Engineer-in-Charge. | 60 | Each | - | - |
| 3 | Supply and fixing in replacement (concealed in wall) factory made Flameproof DB duly painted, 12 Way, SPN, dust and vermin proof including operating knob, cable glands, earth bar, bus bar with all accessories and comprising of the following including taking out old unserviceable existing DB any type complete all as specified and as directed.:-
(i) MCB B curve, SPN 32 Amps, 10KA - 01 No (incoming)
(ii) MCB B curve, SP 6 Amps, 10KA - 10 Nos (outgoing) | 4 | Each | - | - |
| 4 | Supply and fixing in replacement (concealed in wall) factory made Flameproof DB duly painted, 08 Way, SPN, dust and vermin proof including operating knob, cable glands, earth bar, bus bar with all accessories and comprising of the following including taking out old unserviceable existing DB any type complete all as specified and as directed.:-
(i) MCB C curve, SPN 32 Amps, 10KA - 01 No (incoming)
(ii) MCB C curve, SP 6 Amps, 10KA - 06 Nos (outgoing) | 12 | Each | - | - |
| 5 | Supply and fixing in replacement of LED flameproof light fitting 2 x 16/20 Watt, Poly Carbonate appx 4 feet long, environment friendly, including electric connection with using 2 core flexible copper conductor cable 23/0.00076 from ceiling rose to tube fitting, complete fitting with all accessories and following specifications, including taking down old Unserviceable light fitting any type complete all as specified and directed by Engineer-in-Charge :- (a) Lumen system efficacy of luminaire should be minimum 100 Lumen per watt. (b) Input Voltage range : 140 to 270 volts. (c) Temp operating range : Minus 10°C to Plus 45°C (d) Power factor : Minimum 0.95 (e) THD : Max10%. (f) IP rating : IP-20. (g) CRCA pre coated housing with two coloured plastic end cap. (h) LED Driver of the make as of the luminaire. (j) LED driver should be complete with all protections viz open/short circuit protection, over voltage protection, all as per
standard design of manufacturer. (k) Surge protection minimum 2.5 kV. (l) CCT : 6500K | 50 | Each | - | - |
| 6 | S&F in repair flame proof MCB B Curve SP 6 to 32 Amp complete all as specified and as directed. | 40 | Each | - | - |
| 7 | S&F in repair flame proof MCB B Curve SPN 32 Amp complete all as specified and as directed. | 10 | Each | - | - |
| 8 | S&F in repair flame proof switch rotary type with termination box in LM6,16A, single pole 250V complete all as specified and as directed. | 60 | Each | - | - |
| 9 | S&F in repair flame proof switch socket and plug combined in LM6 cable termination box in LM6,16A, 250V, 2P + Earth complete all as specified and as directed. | 30 | Each | - | - |
| 10 | Supply and fix in repair flame proof, water proof Junction box 4 way 20 mm entry size of LM 6 material complete incl all necessary fixing arrangement and electric connection complete all as specified and directed. | 25 | Each | - | - |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.28 MB
BOQ_877888.xls
BOQ • 1.22 MB
tender.pdf
Tender Documents • 1.28 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at [email protected].