Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.1 CrAccepted-AOC 126 NARANG COLONY JANAKPURI NEW DELHI 110058 | WEST | DELHI | 110058 | ₹1.1 Cr | L1 | Accepted-AOC BEING L1 BIDDER |
| 2 | L2₹1.2 Cr+₹14.4 L (13.2%)Rejected-Finance | ₹1.2 Cr+₹14.4 L (13.2%) | L2 | Rejected-Finance BEING L2 BIDDER |
Tender Value
₹1.2 Cr
EMD Value
₹1.9 L
Closing Date
13 Nov 2021, 6:00 pmClosed
CWE (AF) Palam Delhi Cantt-10
HQ CWE (AF) Palam Delhi Cantt-10
SPECIAL REPAIR TO SMC OF HQ WAC (U) AT SUBROTO PARK UNDER GE (AF) SUBROTO PARK DELHI CANTT-10
2021_MES_468014_2
CA NO CWE/PM/SP-12/2021-22
Open Tender
Civil Works
Item Rate
270 days
GE (AF) Subroto Park Delhi Cantt
Please refer Tender documents.
7 documents required · 7 mandatory
₹1,000
GE (AF) Subroto Park
₹1.9 L
Yes
22 Nov 2021
20 Oct 2021
15 Nov 2021
20 Oct 2021
13 Nov 2021
27 Oct 2021
Amount
BOQ PART-I (B/R WORKS)
Demolition of wall and ceiling boards (fibre, pulp, insulation, etc.) or insulation boards/ slabs/ blankets, any thickness , including cover fillets.(incl Removing of debris from defence land and disposed off from the premises where dirceted) complete, all as specified and directed by Engineer-in-Charge.
S & F of 'E' board (Design: LACK & hILL) 605x605x4 mm thick, white pre laminated set embosed reinforced designer ceiling board tiles of approved texture at all height laid on hot dipped galvanised iron imposed grid with 24 mm wide T-section exposed flanges which shall be power coated white. The frame work shall be comprise of main runner made from 0.33 mm thickgalvanised steel sheet and of size 24 mm X32mmX300 mm board spaced at 120 mm maximum centre to centre, hangers of GI wire 4 mm dia to be fixed by approved rawl plug level and fasterners and screws etc.,The last hanger at the end of each main runner shall not be greater than 450 mm from adjecent wall , flushing fitting of 1200 mm longer cross tee(with double stitching) to be interlocked between main runners at 600 mm centre to centre from 1200X600 mm modules cross tee longer than 600 mm to be supported independently . 600mm long cross tee centrally between the 1200 mm cross tee(with double stitching) to be interlocked between main runners at 600 mm centre to centre from 1200X600 mm modules cross Tee longer thyan 600 mm to be supported independently . The perimeter wall angle shall be 0.45 mm thick GS sheet of size 19 mm X 19 mm and 300 mm long of white colour all as per manufacturer's instructions complete, all as specified and directed by Engineer-in-Charge.
Demolition of floor, hearth or wall tiling (floor/wall tiling of ceramic/ kota stone/ marbles/ granite) including cement mortar bedding (but not backing) removing serviceable tiles to spread , rubbish off the premises , complete, all as specified and directed by Engineer-in-Charge.
M&L for PCC 1:2:4 type B-0(12.50 mm graded aggregate), 25mm thick as in sub base to the tile flooring , incl demolition of unreinforced cement concrete as in floors, pavings n.exc 15 cm thick complete, all as specified and directed by Engineer-in-Charge.
M&L for vitrified double charged/dark shade/ Ultra Charged ceramic tiles 10mm thick (square/rectangular) polished, area of each tiles exceeding 0.36sqm but not exceeding 0.42 sqm , in floors etc., set and jointed in neat cement slurry and pointed in white or coloured cement to match etc over 15 mm thick screed in cement mortar (1:4) complete, all as specified and directed by Engineer-in-Charge.
All as per item No 1.05 hereinbefore but in Skirting/ dado over 10mm thick rendering in CM 1:4 complete, all as specified and directed by Engineer-in-Charge.
M&L non skid ceramic coloured tiles 7 to 8 mm thick (square/rectangular) area of each tiles exc 0.11 sqm but n. exc 0.18 sqm, in floors etc, set and jointed in neat cement slurry and pointed in coloured cement to match over 15 mm thick screed bed or bedding layer in CM (1:4) complete, all as specified and directed by Engineer-in-Charge.
M&L Glazed coloured ceramic tiles in vertical surface 350x 250x 7 mm / 450X 350X 7mm / 300X200X7mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match over 10 mm thick rendering in cement mortar(1:4)complete, all as specified and directed by Engineer-in-Charge.
M&L Kota stone slab flooring (Mirror Polished) 20 mm (+/- 2 mm) mm thick over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete, all as specified and directed by Engineer-in-Charge.
M&L Machine Cut Kota stone slab (mirror Polished) 20-25 mm thick in riser of steps, skirting, dado & pillar over 10mm thick plater in CM (1:4) & jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing & polishing complete, all as specified and directed by Engineer-in-Charge.
Taking down chowkhat or frame with shutters of any description (without taking off shutter from the frames) n. exc 1.50 Sqm each complete, all as specified and directed by Engineer-in-Charge.
Taking down chowkhat or frame with shutters of any description (without taking off shutter from the frames) exc 1.5 Sqm but n. exc 4.00 Sqm each complete, all as specified and directed by Engineer-in-Charge.
S&F Aluminium grills 10 mm thick as made by Associated Grill and Profile Ltd. complete, all as specified and directed by Engineer-in-Charge.
S&F 12mm thick prelaminated particle boards, interior grade prelaminated both sides with decorative choice lamination fixed with screws to timber/aluminium frame work complete, all as specified and directed by Engineer-in-Charge.
S&F stainless steel wire cloth, 0.36 mm nominal dia of wire and average width of aperture 1.18mm and fixed with tinned tacks, or stainless steel wire staples complete, all as specified and directed by Engineer-in-Charge.
M&L for 2nd class hard wood plain, solid, straight, chowkats and frames, wrought, framed rebated on the solid, rounded or chamfered, put together with glue pinned at joints, supplied and fixed complete, all as specified and directed by Engineer-in-Charge.
S&F flush shutters, 35 mm thick solid core construction, with block board core and plywood face panels, commercial type on both sides complete, all as specified and directed by Engineer-in-Charge.
M&L for varnishing finishing coat with synthetic varnish over a coat of wood filler liquid transperent including preparation of newly or previously untreated surfaces of any descriprtion over 10 cm width or girth complete, all as specified and directed by Engineer-in-Charge.
S&F door closer hydraullically regulated designation No 3, universal type, suitable for door shutters of 851 to 1000 mm in width and of weight between 61 to 80 kg and fixed complete, all as specified and directed by Engineer-in-Charge.
S&F extruded aluminium alloy handles , fabricated type , anodised 100 mm size of handle complete, all as specified and directed by Engineer -in-Charge.
S&F mortice latch with two levers (vertical type), aluminium anodised body length of latch 100 mm complete, all as specified and directed by Engineer-in-Charge.
S&F 100 mm long butt hinges, extruded aluminium alloy with galvanised mild steel hinge pin, anodised and fixed, type B-21 complete, all as specified and directed by Engineer-in-Charge.
S&F for factory made solid PVC moulded door with particle board core shutter 28 to 30mm thick (stiles) with 2,4, or 6 raised panel design with 2mm thick moulded PVC sheet on the front face & 2mm plain colour PVC sheet on back face, fixing in frame at site as per specification & drawing complete, all as specified and directed by Engineer-in-Charge.
S&F PVC solid door frame of size 50mm x47mm made out of 5mm single side prelam PVC sheet reinforced with MS square tube, fixing in opening as per specification & drawing complete, all as specified and directed by Engineer-in-Charge.
S&F 100 mm long aluminium handles, cast type, anodised complete, all as specified and directed by Engineer-in-Charge.
S&F of 75 mm long aluminium anodised, barrel tower bolts of extruded section and fixed complete, all as specified and directed by Engineer-in-Charge.
S&F 100 mm long medium weight, cold rolled mild steel butt hinges complete, all as specified and directed by Engineer-in-Charge.
S&F 32mm dia aluminium powder coated drapery rod including all necessary fixing arrangement like clamps, end brackets, end to end bracket complete, all as specified and directed by Engineer-in-Charge.
Demolition to brick work or stone/boulder masonry, built in cement mortar complete, all as specified and directed by Engineer-in-Charge.
M&L for brick work with sub class 'B' bricks, straight or curved on plan exc 6m mean radius built in cement mortar (1:6) complete, all as specified and directed by Engineer-in-Charge.
M&L for rendering 15 mm thick on fair faces of brick work or concrete surfaces of walls in cement mortar 1:6 and finished even and smooth without using extra cement complete, all as specified and directed by Engineer-in-Charge.
M&L for preparing new plastered or unplastered surface of walls and applying 2 coats of oil bound distemper over one coat of chalk whitening over 1.50mm thick wall care putty as in walls complete, all as specified and directed by Engineer-in-Charge.
M&L for providing cement concrete type C-1, (1:3:6) ( 20 mm graded stone aggregate) in roof kerbs or mud stops, rounded or chamfered on edges in lintels up to 1.50 m clear span, cills, steps, seismic and other similar bands, pilnth courses, parapets and railing upto 60 cm in height, copings , kneelers, apex stones, bed plates, kerbs not provided for in item 04028, water troughs and like including weathering, slightly rounded or chamfered angles and throating complete, all as specified and directed by Engineer-in-Charge.
Demolition of reinforced cement concrete of any description and in any position not otherwise specifically provided if cement concrete is reinforced (reinforcement cut as required to facilitate demolition) including removing of debris from the defence land and disposed off from the premises where directed complete, all as specified and directed by Engineer-in-Charge.
M & L for RCC (nominal mix ) type B-1, (1:2:4) (20 mm stone aggregate) as in Slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and shelves and the like complete, all as specified and directed by Engineer-in-Charge.
M&L for mild steel TMT bars 6 to 8 mm dia, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends & binding with & including mild steel wire (annealed) not less than 0.9mm dia or securing with clips quality conforming complete, all as specified and directed by Engineer-in-Charge.
M & L for formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work, not exceeding 200m thick (horizontal or sloping), rough finished flat surfaces of concrete complete to walls and ceilings or laid in floors complete, all as specified and directed by Engineer-in-Charge.
M & L for cutting, polishing and bees wax polishing of existing kota stone flooring by machine complete, all as specified and directed by Engineer-in-Charge.
M & L for preparation of old decorated surfaces of walls including scraping down smoke soot, moulds, moss and efflorescent salts and trading oil and greasy spots etc. including cornices, pilasters etc. (Plastered or unplastered surfaces) and applying two coats of plastic emulsion coloured, incl 1.50 mm thick putty complete, all as specified and as directed by Engineer-in-Charge.
M&L for preparation of old decorated surfaces of walls including washing, rubbing down and stopping of distempered and painted surfaces and applying two coat of oil bound distemper (white/tinted) on walls over 1.50 mm thick putty finish complete all as specified and as directed by the Engineer-in-Charge.
M & L for taking down cement plaster of any description on brick or concrete surfaces of walls etc ., incl 12 mm thick cement plaster in cement mortar (1:6) on brick surfaces on brick work and finished even and smooth without using extra cement and preparation of new plastered surface of walls and applying two coats of oil bound distemper over chalk whitening, including removing of debris/rubbish off the premises complete all as specified and as directed by Engineer-in-Charge.
M & L for taking down cement plaster of any description on brick or concrete surfaces of walls , incl 15 mm thick cement plaster in cement mortar (1:4) on concrete or brick surface and finished even and smooth without using extra cement and preparation of new plastered surface of walls and applying two coats cement base paint over a priming plastered and other surfaces with alkali resistant priming paint, including removing of debris/rubbish off the premises complete all as specified and as directed by Engineer-in-Charge.
Supply only integral water proofing compound complete, all as specified and directed by Engineer-in-Charge.
M&L 150 mm thick PCC type C-2, (1:4:8) using 40mm graded stone aggregate as in sub floors, sub bases, floors and pavings, etc complete, all as specified and as directed by Engineer-in-Charge.
M&L for 150 mm thick cement concrete type C 2, 1:3:6 (using 20 mm graded granite stone aggregate) in sub base of path/floor/hard standing finished even and fair surfaces complete all as specified and as directed by Engineer-in-Charge.
M&L for repairs (cutting of RCC fins/facia in any position of any description in a symmetrical manner with cutting tools/machineries required including all necessary arrangements) to broken sides/faces of fins/ facade , facia by all means i.e. cement plaster of any thickness or cement concrete 1:1.5:3, type B-0 (using 12.5 mm graded stone aggregate) etc using chicken wire mesh to reinforce & form work and making good as required design (for aesthetic appearence) including two coats of weather proof acrylic paint over primming coat complete, all as specified and directed by Engineer-in-Charge.
S&F in repairs WHB counter top oval type size 195x814x470mm with pedestal excluding taps, waste chain plug and plain stopper, but including brackets including waste pipe complete, all as specified and directed by Engineer-in-Charge.
S&F in repair to rotational moulded vertical water storage tanks of capacity 500 liters, triple layered (white in colour) with closed tops (cylindrical) hoisted and fixed in position, including disconnecting and refixing the existing GI fitting and pipe complete, all as specified and directed by Engineer-in-Charge.
S&F in repair to rotational moulded vertical water storage tanks 1000 litres, triple layered (white in colour) with closed tops (cylindrical) hoisted and fixed in position, including disconnecting and refixing the existing GI fitting and pipe complete, all as specified and directed by Engineer-in-Charge.
S&F ball valves high pressure of PTMT with epoxy coated aluminium rod & high density plastic ball screwed suitable for iron pipe 20mm bore complete, all as specified and directed by Engineer-in-Charge.
S&F as in repairs, gate valves gun metal with iron wheel head screwed both ends for iron pipe and fixed 20 mm bore fixed complete, all as specified and directed by Engineer-in-Charge.
Taking down or up 15 mm steel water tubing including S&F steel water tubing, galvanised, medium grade, ISI marked with all fittings and fixed on walls and ceilings or laid in floors bore of pipe 15 mm complete, all as specified and as directed by Engineer-in-Charge.
Taking down or up 20 mm steel water tubing S&F steel water tubing, galvanised, medium grade, ISI marked with all fittings and fixed on walls and ceilings or laid in floors bore of pipe 20 mm and removing to store complete, all as specified and directed by Engineer-in-Charge.
M&L for PCC (1:2:4) type B-1 (Using 20 mm graded stone aggregate) in roof kerbs, plateform for PVC tank, on roofs or below or above ground level and in any position, etc complete, all as specified and as directed by Engineer-in-Charge.
S&F in repair CP shower rose 125 mm square size with arms 15 mm dia 195 mm long with bends 45 mm degree with flange of brass complete, all as specified and directed by Engineer-in-Charge.
S&F in repairs CP body hand shower (health faucet) with 1 meter long easy flex tube in chrome finish & wall hook complete, all as specified and directed by Engineer-in-Charge.
S&F as in repairs, toilet paper holder with flap recessed type (stenless steel) complete, all as specified and directed by Engineer-in-Charge.
S&F as in repairs, vitreous china wash down water closet pan (Pedestal pattern) excluding flushing cistern and flush pipe and including , cast iron P or S trap, connection, seat cover complete, all as specified and directed by Engineer-in-Charge.
S&F as in repairs, vitreous china squatting pan “Orissa” pattern of size 580mmx440mm “white” with integral foot rest (excluding flushing cistern and flush pipe) including provision of cement concrete bedding, CI ‘P’ trap 100mm dia connection to trap and flushing pipe, anti-syphonic complete, all as specified and directed by Engineer-in-Charge.
S&F as in repairs, 10 litre PVC valve less syphonic action type low level flushing cistern with inlet ball valve float and handle incl CI bracket and 32mm bore PVC flush pipe and connection to pipe complete, all as specified and directed by Engineer-in-Charge.
S&F as in repairs, vitreous china wash hand basin of size 550 mm x 400 mm white, flat back including angle iron brackets including waste pipe of 32 mm dia of suitable length, PVC connection of 15 mm dia & 450 mm long with PTMT nuts with 32 mm dia brass chromium plated bottle trap and waste coupling complete, all as specified and directed by Engineer-in-Charge.
S&F as in repairs, soap hand dish niche chromium plated fancy type complete, all as specified and directed by Engineer-in-Charge.
S&F as in repairs, PVC cabinet mirror (600x400x160 mm) decorative white wall mounted complete, all as specified and directed by Engineer-in-Charge.
S&F fancy type mirror of 5 to 10 mm thick glossy glass decorative type, bevelled edges allround, wall mounted mirror complete, all as specified and directed by Engineer-in-Charge.
S&F as in repairs, liquid soap dispenser with s/s metalic bottle complete, all as specified and directed by Engineer-in-Charge.
S&F towel rack 600mm long with lower hangers complete, all as specified and directed by Engineer-in-Charge.
S&F in repairs, towel ring squar type complete, all as specified and directed by Engineer-in-Charge.
S&F vitreous china bowl urinal flat back, size of 465 x 355 x 265 mm white (minimum), with grating and union for discharge pipe (excluding flushing cistern, flush pipe and waste pipe) complete, all as specified and directed by Engineer-in-Charge.
S&F pillar tap, cast copper alloy, chromium plated, with capston heads screwed down, high pressure with or without lettered hot or cold with long screwed shames and fly nuts, screwed for 15mm bore pipe complete, all as specified and directed by Engineer-in-Charge.
S&F as in repairs, bib taps, cast copper alloy, fancy type with crutch or butterfly handles, chromium plated, screwed down to iron pipes or for brass ferrule of 15mm bore complete, all as specified and directed by Engineer-in-Charge.
S&F as in repairs, angle valve/stop valve, cast copper alloy, fancy type, chromium plated with long shank & cup (concealed type) with crutch or butterfly handle, screwed both ends for iron pipe of 15mm bore complete, all as specified and directed by Engineer-in-Charge.
S&F as in repairs pillar cock, CP 15mm bore cast copper alloy with chromium plated fancy type screwed both ends, screwed down high pressure without lettered Hot or Cold with long screwed shanks and fly nuts screwed for iron pipe complete, all as specified and directed by Engineer-in-Charge.
S & F 15mm dia chromium plated bib taps, cast copper alloy with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule and fixed complete, all as specified and directed by Engineer-in-Charge.
S&F 15mm dia PVC connection 450 mm long with brass nuts complete, all as specified and directed by Engineer-in-Charge.
S&F mild steel chromium plated grating (round) 125/150mm dia fixed over floor/nahani trap (with hole and without hole) complete, all as specified and directed by Engineer-in-Charge.
S&F glass shelf assembly consisting of 5.5 mm thick sheets glass shelf 12cm wide with chromium plated bracket guard and railing 60cm long complete, all as specified and directed by Engineer-in-Charge.
S&F corner glass shelf assembly consisting of 5.5 mm thick sheets glass shelf with chromium plated bracket guard and railing complete, all as specified and directed by Engineer-in-Charge.
M & L for complete removal of existing roof treatment including bedding layer in cement mortar and disposed from site n.exc 500 m complete, all as specified and directed by Engineer-in-Charge.
Demolition of cement concrete (unreinforced) of any description and in any position not otherwise specifically provided for complete as in bedding of roof treatment, roof kerbs etc complete, all as specified and directed by Engineer-in-Charge.
M&L for five layer prefabricated atactic polypropylene polymer (APP) modified 3.00 mm thick membrane ( weight not less 3 kg/sqm) reinforced with 160 gm polyester non-woven fabric with scratched tool, 10 mm thick (1:4) cement plaster shall be laid over the roof surface shall be throughly wire brushed washed dried up and cleaned of all foreign matter and dust prior to the application of primer on the dried surface one coat of approved bituminous primer, having density in the range of 0.87 to 0.89/kg at 25 dgree and viscositing of 70 to 130 CPS manufactured by the same manufacturer @ 0.40 litres/sqm shall be applied and applying one coat of industrial bitumen grade 85/25 evenly over bitumous primer . APP membrane shall be laid on primed surface by tourch application mehtod. After allowing 24 hours of primer to dry. Laying of APP membrane shall be commneced at the lowest level and worked upto the crest.APP membrane will normally be laid in length at right angle to the direction of slope. The overlaps shall be of minimum 100 mm on longitudinal direction and 150mm on the transverse direction. All overlaps shall be bonded with bitumen primer and levelled by the heating the overlaps with brutane tourch. This treatment shall be done by the approved authorised applicator. Guarantee of treatment shall be for 10 years. Thereafter APP membrane shall be painting with two coat of water proofing paint with aluminium finish.
M&L for PCC (1:2:4) type B -1 (using 20mm graded stone aggregate) mixed with water proofing compound as per manufacturer instructions laid 25 mm thickness as in padding over roof slabs for providing proper slope to the concrete padding, surface finished even and smooth without using extra cement complete, all as specified and directed by Engineer-in-Charge.
M&L for providing cement concrete type C-1, 1:3:6 (20 mm graded stone aggregate) as in plinth courses , apex stones, hard standing , etc complete, all as specified and directed by Engineer-in-Charge.
M & L for providing cement concrete type B-O, 1:2:4 (12.5mm graded stone aggregate) as in copings rounded or chamfered edges, kneelers, water troughs and the like including weathering, slightly rounded or chamfered angles and throatings, etc complete, all as specified and directed by Engineer-in-Charge.
S&F 150 mm bore PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to walls complete, all as specified and directed by Engineer-in-Charge.
S&F 150 mm bore PVC (SWR) bends any radius complete, all as specified and directed by Engineer-in-Charge.
S&F 150 mm wide water proofing APP bituminous membrane felt flashing tape (multi purpose self adhesive sealing tapes) SBS (Styrene Butadiene) modified bituminous water proofing compound made with buty1 rubber with self protecting Aluminium upper surface with non stick plastic as release layer in lower face, including preparation of old/ new surfaces and necessary materials and equiptements, the applicator should be from approved authorised applicator complete, all as specified and directed by Engineer-in-Charge.
M&L for applying two coats of highly reflective bitumen based aluminium/silver paint as per (IS-2339-1963) (DFT 30 to 40 microns) over existing water proofing treatment incl preparation of surface and cleaning of surface from dirt, dust, scale, loose coating and rust by wire brush , etc., and paint shall be applied by paint brush, squeeze or airless spray equiptement at the recommended coverage rates (6 to 8 sqm/litre) all brush strokes should be in one direction complete, all as specified and directed by Engineer-in-Charge.
M&L for racking out joints/pointing to old stone masonary random rubble or polygonal rubble , uncoursed or brought up to courses in cement mortar incl raised pointing to random or polygonal rubble, uncoursed or brought upto course in cement morta (1:3), as in any storey/position including necessary props/scafoldings, all necessary arrangements complete, all as specified and directed by Engineer-in-Charge.
M&L for acid washing with muriatic acid of stone masonary including wetting of stone masonary using garden hose to fully saturate the stone , diluting the acid with water, applying the Acid solution onto the stone surface using a stiff-bristled plastic brush, scrubbing and rinsing the stones, complete removal of scales, dust and impurities over stone surfface, surface should be brought upto shining and polished condition, as in any storey/ position including necessary props/scafoldings, all necessary arrangements complete, all as specified and directed by Engineer-in-Charge.
M&L for taking down cement plaster of any description on brick or concrete surfaces of walls etc including 5 mm thick cement plaster in cement mortar (1:3) on concrete or brick surface and finished even and smooth w/o using extra cement as in ceiling and preparation of new plastered surface of ceiling and applying three coats of white wash on ceiling, incl removing of debris/rubbish off the premises complete, all as specified and directed by Engineer-in-Charge.
M&L for applying one coat of synthetic enamel paint as in steel surfcaes of any description over 10 cm width or girth, not otherwise described, including preparation of old painted surfaces complete, all as specified and directed by Engineer-in-Charge.
Providing and fixing 10mm thick plaster of Paris ceiling (Gypsum anhydrous) to sunk or raised moulding to flat surface over metal frame work including reinforced with G.I. wire mesh & Gl frame work for seamless ceiling comprising of Gl perimeter channel 0.55 mm thick with two unequal flanges of 20 and 30 mm and web of 27 mm fixed to surrounding wall using nylon sleeves and screws at 450 mm centre to centre/ intermediate channel 0.9 mm thick having two equal flanges of 15 mm each and web of 45 mm suspended from soffit at approx. 900 mm centre to centre with Gl cleat and steel expansion fasteners with and including ceiling section (not exc 1.2 m length) of 0.55 mm thickness having kurled web of 50 mm and flange of 26 mm each with lips of 10.5 mm fixed to the intermediate channel with connecting clips across the intermediate channel at 457 mm centre to centre & Hangers 6 mm dia. G.I. (upto 1200mm length) adjusting level fixed to roof slabs by means of ceiling cleats made out of G.I. flat 40 x 3 mm size 60mm long and expansion hold fasteners 12.5mm dia. 40mm long incl taking down old ceiling and two coat of OBD over finish surface complete, all as specified and directed by Engineer-in-Charge.
Supply, fabrication and erection of structure on any shape (round, oval or box type) for 3mm thick Aluminium composite panel cladding made of aluminium channel (25 x 50 x 1.6mm) with cleat angle (8 x 18 x 2mm) necessary hardware with material and weather sealant to make joint leak proof and supply and fixing of 3mm thick PVDF coating Aluminium composite panel complete in all respect of Indo bond or equivalent make as per approval of GE. Spacing of the channel should be as per manufacture instruction complete, all as specified and directed by Engineer-in-Charge.
S&F 20mm thick granite (of any type) work (table rubbed & polished) in steps, jambs, pillars, window-cills cooking platforms & like in cement mortar (1:4) including pointing into white cement (1:2) using marble dust with admixture of pigment to match shade of granite including 15 mm thick rendering in CM (1:4) for laying of granite . complete, all as specified and directed by Engineer-in-Charge.
M&L for complete removal of existing treatment from the walls and applying ROYAL TEXTURE PAINT OF ANY TINT from ASIAN PAINTS over one coat of priming paint of any tint over Birla Putty on walls including preparation of surfaces, rubbing etc complete, all as specified and directed by Engineer-in-Charge.
Dismantling aluminum work in cubicals, partitions etc with all acessories including removal from site complete, all as specified and directed by Engineer-in-Charge.
S&F powder coated (minimum thickness of powder coating 50 micron) anodised aluminium frame for door, window, partitions and ventilator with one or more rebates including jointing cleat for fixing etc. complete, all as specified and directed by Engineer-in-Charge.
S&F powder coated (minimum thickness of powder coating not less than 50 micron) anodised aluminium door shutters of section weighing 0.55 Kg/m including necessary joining cleats, glazing clips, rubber neoprene packing, handle 2 Nos in each door, hinges, anodised aluminium snap beading, screws etc. complete, all as specified and directed by Engineer-in-Charge.
S & F powder coated (minimum thick of powder coating not less than 50 micron) anodised aluminium window and ventilator shutters, side hunge type without sash bar, aluminium section weighing 0.55 Kg/m including necessary joining, cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws, anodised aluminium fittings such as peg stays 150 mm long (02 Nos), hinges type B-21 100 mm long (02 No), suitable handle (01No) complete, all as specified and directed by Engineer-in-Charge.
M&L for acid itched toughned glass of 10 mm thick of any colour as in doors, partitions, windows, structural glazing, walls etc with kolf SAFEX fitting acessories like wheel SSF 22SS, track SST 30A (3meter) and handle SSH 7 (65mm) or OZONE fitting acessories like wheel OZE-ESL-11-200, track 02-SL-44-B3, handle SL-HN-50, with pivot, nad sliding arrangement, and all necessary required accessoeies/fitting for fixing, including removing of old glazing in any position/any description, all as specified and as directed by Engr-in-charge.
S&F Stainless steel work as in railing/balusters/pillasters of any section (SHS/RHS/CHS) of any thickness including necessary stainless steel frame work of design and conforming to SS 304, complete all as specified. incl demoliton/ dismantlling of wrought iron/stainless steel hand rails/balusters, etc., complete, all as specified.
BOQ PART-II (E/M WORKS)
Taking down old copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc.removing materials and making good disturbed surfaces of walls, floors, etc complete all as specified and directed by Engineer-in-Charge.
Taking down old Unserviceable LT panel including all connected accessories and electric connection, removing material and making good disturbed surfaces of walls, floors, etc complete, all as specified and directed by Engineer-in-Charge.
M&L for point wiring with single core of FRLS PVC insulated unsheathed ISI marked 1100 V grade cable multi stranded copper conductor of size 1.5 sqmm drawing through in and including PVC casing & caping size of not less than 20mm including all acessories in wall / ceiling or surface, wiring on ceiling /wall terminated in sheet metal flush box alongwith outer cover plate for mounting switch, socket and electronic regulator along with provn of earth wire of PVC insulated, unseathed, 1100 V grade cable multi stranded FRLS ISI marked copper conductor of size 1.5 sqmm for one light point controlled by one switch one way complete all as specified and directed by Engineer-in-Charge. (Note : Cost of making good to disturbed surface all as to match with existing surface are deemed to be included in quoted rate.)
All as per srl item 3.03 above but for one Ceiling fan/Exhaust fan point controlled by one switch one way Complete all as specified and directed by Engineer-in-Charge.
All as per srl item 3.03 above but for call bell controled by one modular push button in indipendent board Complete all as specified and directed by Engineer-in-Charge.
All as per item No 3.03 above but for one 3 pin 5 amps socket outlet on indipendent board with other switchs Complete all as specified and directed by Engineer-in-Charge.
All as per item No 3.03 above but for one 3 pin 5 amps socket outlet on the same board with other switchs Complete all as specified and directed by Engineer-in-Charge.
All as per item No 3.03 above but with 2.5 Sq mm cable for Independent board one 3 pin 15 Amps socket outlet including S/C 2.5 Sq mm PVC insulated copper conductor unsheathed 1100 v grade IS -694 FR LS cable for continuous earth wire complete all as specified and directed by Engineer-in-Charge.
S&F in replacement switch piano, flush type single pole, one way, 5 Amps, 240 volts complete all as specified and directed by Engineer-in-Charge.
Supply only in replacement bell push, modular type, 5 Amps, 240 volts complete all as specified and directed by Engineer-in-Charge.
Supply only in replacement electric calling bell multi music Type suitable for 230 volts complete all as specified and directed by Engineer-in-Charge.
S&F in replacement switch piano, flush type single pole, one way, 15 Amps, 240 volts all as specified and directed at site complete all as specified and directed by Engineer-in-Charge.
S&F in replacement socket outlet 3 pin 5 Amps complete all as specified and directed by Engineer-in-Charge.
S&F in replacement socket 15 Amps, 2 in 1, flush type complete all as specified and directed by Engineer-in-Charge.
S&F in replacement fan regulator,120 W, 2 module complete all as specified and directed by Engineer-in-Charge.
M&L for sub main wiring 2 Run of 4 Sqmm cable and one run of 4 sqmm cable dolly earth continuity of S/C PVC insulated but unsheathed FRLS cable of specified size with multistranded copper conductors 1100 volt grade IS- 694 marked drawn through and including non metalic PVC conduit pipe medium grade ISI marked (not less than 20 mm dia) along with fittings and accessories including the specified runs of specified size earth continuity conductor of similar type of cable complete all as specified and directed by Engineer-in-Charge. (Note : 2 runs of main cable one run of earth wire one run of PVC pipe will be measured as an one run).
All as per item No 3.16 above but 2 Run of 6 Sqmm cable and one run of 6 sqmm cable dolly earth continuty complete, all as specified and directed by Engineer-in-Charge.
Taking down carefully copper/aluminium surface/conduit sub main wiring of any size from Main DB to sub DB and making good disturbed surfaces or walls, floors, etc complete all as specified and directed by Engineer-in-Charge.
Supply and fixing wall mounted LED batten extruded aluminium heat shrink provided for efficient heat dissipation and integrated electronic driver ,1X20 watt MS white powder coated Decorative LED T8 batten fitting with PC Tube, 100 lumen/watt, 6000K, 230 Volts, complete with all accessories, connecting up with twin core twisted flexible copper conductor cable from ceiling rose to fitting, and testing complete all as specified and directed by Engineer-in-Charge.
Supply and fixing wall mounted LED bulk head fittings, 10 watt, warm white, 230 Volts, diffused optics etc complete with all accessories, connecting up with twin core twisted flexible copper conductor cable from ceiling rose to fitting, and testing complete all as specified and directed by Engineer-in-Charge.
Supply and fixing ultra round slim recess downlight decorative 18 watt with 90 lumen/watt, 6000 K, 230 volt, LED ceiling fitting, complete with all accessories, connecting up with twin core twisted flexible copper conductor cable from connector to fitting, and testing complete all as specified and directed by Engineer-in-Charge.
Supply and fixing in replacement of surface mounted LED backlit panel for efficient heat dissipation and integrated electronic driver 2'x2', 30 watt white powder coated CRCA full glow LED fitting, 6000K, 230 Volts, etc complete with all accessories, connecting up with twin core twisted flexible copper conductor cable and testing complete all as specified and directed by Engineer-in-Charge.
S&F ultra slim panel modern design 36 watt 2'x2' extruded aluminium housing with milky diffuser recess mounting ultra slim LED panel, 6000 K luminaire having glare free symmetrical illumination complete all as specified and directed by Engineer-in-Charge.
Taking down carefully ceiling fan of any size/sweep and with one single pole MCB 20A 240 Volts all as specified and directed by Engineer-in-Charge.
Fixing only celing fan after servicing greasing and painting received from item No. 3.24 above and connecting up including provision of suitable size of copper cable from connector of fans to ceiling rose complete all as specified and directed by Engineer-in- Charge.
S&F ceiling fans 1200 mm sweep, 5 star rating, 230 volt SP, with all acessories including provision of MS hooks suitable for hanging ceiling fans and suitable size and length of copper wire and down rod complete all as specified and directed by the Engineer-in-Charge.
S&F single pole and neutral enclosure with a two pin and earth plug and socket with one single pole MCB 20 Amps, 240 Volts, 'C' series complete all as specified and directed by Engineer-in-Charge.
Taking down carefully exhaust fan of any size/sweep complete all as specified and directed by Engineer-in-Charge.
Fixing only exhaust fan and connecting up including provision of cable from ceiling rose/connector to exhaust fan retrieved from item No 3.28 complete all as specified and directed by Engineer-in-Charge.
S&F fresh air fan 300/380 mm sweep, PVC body, heavy duty, 230 volt, with all acessories including provision of suitable cutting making hole for suitable size and length of copper wire and ceiling rose complete all as specified and directed by Engineer-in-Charge.
Taking down unserviceable single pole and neutral enclosure with two pin and earth plug after disconnecting the electric supply, complete all as specified and directed by Engineer-in-Charge.
Supply and fixing ceiling rose polycarbonate, isolated body 65 X 50 mm, 2 to 3 terminal complete all as specified and directed by Enginner-in-Charge.
Supply and fixing in replacement MCB distribution board with Bus bar 200A neutral link , earth bar made out of CRCA mild steel sheet surface mounting SPN 12 way 230 volts double door type regal gray horizontal type complete, all as specified and directed by Engineer-in-Charge. .
Supply and fixing in replacement MCBs 10 KA breaking capacity, single pole, 240 volts, 6 to 32 amps, C Curve capacity complete all as specified and directed by Engineer-in-Charge.
Supply and fixing in replacement MCBs 10 KA breaking capacity, single pole, and neutral, 240 volts, 63 amps, C Curve capacity complete all as specified and as directed by Engineer-in-Charge.
Taking down old unsvserviceable MCB DB including MCBs of any size complete all as specified and as directed by Engineer-in-Charge.
M&L earthing complete with galvanised steel earth plate electrode 600x600x6.3 mm, burried vertically in ground (earth pit not less than 2.25 m deep below normal ground level) with top edge of plate vertically to a depth not less than 1.5m below ground level, connected to galvanised steel earth lead wire 4.00 mm dia (8 SWG) of any length as reqd at site, by means of bolts, nuts, check nuts and washers of galvanised steel, earth lead wire encased in and including 15mm bore G.I. light grade pipe from earth plate upto pole, upto 2.40 M height from GL by means of and including 25 x 3 mm M.S.F.I. Clamps, bolts, nuts and washers etc. and GI Earth lead wire poles/feeders, gang operated air break switches etc. with provision of charcoal dust and common salt packed all around the earth plate, including necessary excavation and earth work in any type of soil/strata and testing complete all as specified and directed and shown on electrical plate No. 5 of SSR Part I (1991) complete all as specified and directed by Engineer-in-Charge. Note : GI wire more than 7.5m will be measured separately.
Supply, installing, testing and commissioning factory made and tested (Inclusive CPRI Test certified) LT feeder pillar box outdoor type, platform mounted suitable for 3 phase, 4 wire, 50 Hz, AC supply system base busbar chamber with insulated AC/copper busbar 400 amps (3 Nos) phase and 200 amps for neutral rating installed on porcelain insulator. The panel shall be dust and vermin proof IP65 class protection and made out of 3.15 mm thick CRCA MS sheet and 50 mm x 50 mm x 6 mm thick angle iron frame works, powder coated finish over one coat of red oxide primer outside two coats of red oxide primer inside, front opening type with approns for cable ending with double door shutter and locking arrangement (including provn of 65 mm Godrej (freedom) lock with 2 keys, insulated copper conductor FRLS IS-699 marked 1100 volt grade but sheathed cable adequate size but not less than 4 mm size comlete all as specified and as directed by Engineer-in-Charge.
BOQ PART-III (REFG/AC WORKS)
M&L for disconnecting, shifting of tower type/slim line air conditioner floor mounted unit of 3.5 TR (indoor and outdoor unit) of any make & model from one location to another location and refixing the tower type AC after over hauling & servicing of tower type/slim line air conditioner with gitties/fasteners, cutting wall/concrete including arrangement of required T&P, positioning of outdoor condensing unit on stand, fixing of extra PVC flexible multistranded copper conductor of size 10 Sqmm 4 core and brazing work, leak check, dehydration and charging of refrigerant gas upto recommended level, connection of drain pipe, making good the disturbed surface including PCC and brick work and testing the unit for satisfactory functioning complete all as specified and as directed by Engineer-in-Charge.
Supply & fix in replacement triple pole and earth enclosure with a plug with socket complete with one triple pole MCB 40 amps 10 KA complete, all as specified and directed by Engineer-in-Charge.
M&L in replacement submain wiring complete with non metallic rigid PVC insulated fire retardent grade unsheathed 1100 volts grade multistranded copper conductor cable 4 run of 10 Sqmm single core conforming to IS-694 with copper conductor drawn through and including suitable dia PVC conduit, conduit fittings and accessories concealed in walls, roofs and floors along with 2 run of 10 sqmm PVC insulated unshaethed cable with multistranded copper conductor as earth contuinity conductor complete, all as specified and directed by Engineer-in-Charge.
M&L in replacement of copper tubing concealed of dia 7/8" including insulation and brazing work complete all as specified and directed by Engineer-in-Charge.
M&L in replacement of copper tubing concealed of dia 3/8" including insulation and brazing work complete all as specified and directed by Engineer-in-charge.
S&F in replacement double door load line 3 phase 415 volts verticle enclosure DB 8 way for housing incoming MCCB and outgoing MCB TPN with suitable capacity busbar 200 apms complete all as specified and directed by Engineer-in-charge.
S&F in replacement MCCB 3 pole 415 V adjustable type 63 amps with breaking capacity 25 KA complete all as specified and directed by Engineer-in-charge.
Supply & Fix in replacement MCB TP, 20 Amps complete all as specified and directed by Engineer-in-Charge.
Supply & laying in replacement of PVC insulated armoured copper cable conductor of 16 sqmm 4 core for voltage upto 1100 volts on wall/roof including accessories such as suitable size of conduit, clamps, fastners and lugs complete all as specified and directed by Engineer-in-charge.
Supply & laying in replacement of PVC insulated armoured aluminium conductor of 95 sqmm 3.5 core for voltage upto 1100 volts including accessories such as calmps, fastners and lugs complete all as specified and directed by Engineer-in-charge.
M&L for disconnecting, shifting of split type AC of any make & model from one location to another location after overhauling and servicing and refixing the AC with gitties/fastners, cutting wall/concrete including arrangement of required T&P, positioning of outdoor condensing unit on stand, fixing of extra PVC flexible multistranded copper conductor of size 2.5 sqmm and brazing work, leak check, dehydration and charging of refrigerant gas upto recommended level, connection of drain pipe, making good the disturbed surface including PCC and brick work and testing the unit for satisfactory functioning complete all as specified and directed by Engineer-in-charge.
M&L for disconnecting, shifting of voltage stabilizer of any make & model & capacity from one location to another location and refixing the voltage stabilizer and proper connection with gitties/fastners complete all as specified and directed by Engineer-in-charge.
M&L cross arms bracing supports clamps and back plates fabricated from structural steel section of size 40x40x6 mm angle iron including nuts bolts washers welding bending cold or hot drilled holes for bolts in any shape or size as indicated or directed and inclusive of one primer coat one under and finished coat of paint for installation of condensing unit on the wall/ground complete all as specified and directed by Engineer-in-charge.
Supply & Fix in replacement single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB 20-32 amps complete all as specified and directed by Engineer-in-charge.
M&L in replacement submain wiring complete with non metallic rigid PVC insulated fire retardent grade unsheathed 1100 volts grade multistanded copper conductor cable 2 run of 6 Sqmm single core conforming to IS-694 with copper conductor drawn through and including suitable dia PVC conduit, conduit fittings and accessories concealed in walls, roofs and floors alongwith one run of 6.0 Sqmm PVC insulated unsheathed cable with multistranded copper conductor as earth continuity conductor complete all as specified and directed by Engineer-in-charge.
M&L in replacement of copper tubing concealed of dia 5/8" including insulation and brazing work complete all as specified and directed by Engineer-in-charge.
M&L in replacement of copper tubing concealed of dia 1/2" including insulation and brazing work complete all as specified and directed by Engineer-in-charge.
M&L in replacement of copper tubing concealed of dia 1/4" including insulation and brazing work complete all as specified and directed by Engineer-in-charge.
S&F in replacement low density polythylene pipes (LDPE) of pressure rating 6 kg/cm3 drain pipes of size 20mm from indoor unit to exist point as per design including accessories clamps fastners complete, all as specified and directed by Engineer-in-Charge.
S&F in replacement PVC insulated and PVC round sheathed copper conductor (flexible) industrial cable 11 volts conforming to IS-694 of size 2.5 Sqmm 3 core complete, all as specified and directed by Engineer-in-Charge.
S&F in replacement of double door 3 phase 415 volts triple pole and neutral DB 4 way for housing incoming isolator TPN and outgoing MCB SP complete, all as specified and directed by Engineer-in-Charge.
S&F in replacement isolator TPN 63 Amps complete, all as specified and directed by Engineer-in-Charge.
S&F in replacement of MCB single pole 32 Amps 230 volts complete, all as specified and directed by Engineer-in-Charge.
M&L for diconnecting, shifting of air curtain of any make & model from one location to another location after overhauling & servicing and refixing the air curtain with gitties/fastners cutting wall/concrete including arrangement of required T&P and testing the unit for satisfactory functioning complete, all as specified and directed by Engineer-in-Charge.
Disconnecting all ducting with grills/diffusers and connected accessories complete, all as specified and directed by Engineer-in-Charge.
Hindustan Co.Co
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .