Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹37.4 LAccepted-AOC | L1 | Accepted-AOC Lowest Bidder | |
| 2 | L2₹40.5 L+₹2.0 L (5.07%)Rejected-Finance 83 5M 1 SHIV GANGA PURAM YADAVPUR ROAD UMARPUR NEEWAN PRAYAGRAJ 211011 | PRAYAGRAJ | UTTAR PRADESH | 211011 | L2 | Rejected-Finance Other than lowest Bidder | |
| 3 | L3₹41.6 L+₹3.1 L (7.98%)Rejected-Finance | L3 | Rejected-Finance Other than lowest Bidder | |
| 4 | L4₹41.8 L+₹3.3 L (8.45%)Rejected-Finance | L4 | Rejected-Finance Other than lowest Bidder | |
| 5 | L5₹41.9 L+₹3.4 L (8.86%)Rejected-Finance 20 8 EWS PREETAM NAGAR COLONY ALLAHABAD | PRAYAGRAJ | UTTAR PRADESH | 211001 | L5 | Rejected-Finance Other than lowest Bidder |
Tender Value
₹36.9 L
EMD Value
₹73,760
Closing Date
20 Mar 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE (AF) Bamrauli
GE (AF) Bamrauli
SPECIAL REPAIR/ REPLACEMENT TO POWER SUPPLY INFRASTRUCTURE AND STREET LIGHT TIMER AND CONNECTED ITEMS UNDER GE (AF) BAMRAULI
2023_MES_583561_1
8777/E8
Open Tender
Civil Works
Item Rate
180 days
GE (AF) Bamrauli
Please refer Tender documents.
6 documents required · 6 mandatory
₹500
GE (AF) Bamrauli
₹73,760
4 May 2023
1 Mar 2023
28 Mar 2023
1 Mar 2023
20 Mar 2023
14 Mar 2023
Amount
supply and fixing in replacement of single phase nature timer switch-02 (sensor) based illuminance level for switchong ON < 60 Lux & for switching OFF > 10 Lux, along with part-night operation facility of minimum 04 hrs to maximum 12 hrs with hensel enclosure integrated models of rating 40 Amps, suitable contactor, incoming and outgoing MCBs and enclosure etc conforming to IP 66 protection type all as specified and directed by Engr-in-Charge
supply and fixing in replacement of three phase nature timer switch-02 (sensor) based illuminance level for switchong ON < 60 Lux & for switching OFF > 10 Lux, along with part-night operation facility of minimum 04 hrs to maximum 12 hrs with hensel enclosure integrated models of rating 32 Amps, suitable contactor, incoming and outgoing MCBs and enclosure etc conforming to IP 66 protection type all as specified and directed by Engr-in-Charge
Supply , laying in replacement and testing cable XLPE insulated ,screened PVC bedded , galvanised steel strip or wire armoured electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 25 Sqmm 4 Core all as specified and directed by Engr-in-Charge
Supply , laying in replacement and testing cable XLPE insulated ,screened PVC bedded , galvanised steel strip or wire armoured electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 16 Sqmm 4 Core all as specified and directed by Engr-in-Charge
Supply , laying in replacement and testing cable XLPE insulated ,screened PVC bedded , galvanised steel strip or wire armoured electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 10 Sqmm 4 Core all as specified and directed by Engr-in-Charge
M&L Boring of holes (manually) under road, hard standing without damaging the surface for 50 mm bore GI pipe. NOTE:- (i) Depth of hole shall be 1 Metre below the top surface of Road/hard standing.
Supply & Laying in trenches for road/plinth and fixing alongwith pole/wall GI Tube 40 mm light grade for protection of cable
Excavation in trenches not exceding 1.5m wide and noe exceding 1.0 sq m on plan and not exceding 1.5m depth and getting out soft soil all as specified and directed
Returing filling in including spreading leveling watering and well ramming in layer not exceding 25 cm as in soil all as specified and dirceted all as specified and directed
Removing excavated material not exceding 50 m and depostingwhere directed at a level not exceding 1.5 m above the starting pointall as specified and directed
M & L for sand cushioning all around the cable for protection by natural sand all as specified and directed
Supplying and Laying old size bricks of size 230mm x 113 mm x 75 mm for cable protection all as specified and directed
Supply and fixing in replacement of contactor ML-6 type all as specified and directed by Engr-in - charge
Supply and fixing in replacement of MCB SPN 32 Amps rated capacity all as specified and directed by Engr-in-charge
Supply and fixing in replacement of MCB TPN 32 Amps rated capacity all as specified and directed by Engr-in-charge
Supply and fixing in replacement of KIOSK junction box IP 65 protection all as specified and directed by Engr-in-charge
Supply and fixing in replacement of analog type timer all as specified and directed
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size size 240 Sq mm 3½ core.
Supply , laying, jointing and testing in replacement of underground LT cable XLPE insulated ,screened PVC bedded , galvanised steel strip or wire armoured electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 70 Sqmm 3.5 Core laid in trenches/ducts/along poles/ through pipe under road etc all as specified and directed by Engr-in-Charge
Supply , laying, jointing and testing in replacement of underground LT cable XLPE insulated ,screened PVC bedded , galvanised steel strip or wire armoured electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 35 Sqmm 3.5 Core laid in trenches/ducts/along poles/ through pipe under road etc all as specified and directed by Engr-in-Charge
M&L for GI tubing 'light grade' of size 80 mm bore size with all necessary fittings laid in trenches/under road crossing/fixed on pole/wall/under floor including suitable mild steel FI clamps of required size complete all as directed
Boring holes 2 m deep in soil for under-reamed piles and getting out for road crossing of UG cable and disposal of spoil to a distance of n exc. 50 m complete all as specified and directed.
Supply and fix double compression copper stain less steel gland for fixing armoured cable in panel of size 3½ core 240 Sq mm size
Supply and fix cable jointing kit for 1100 Volt grade cable for End terminal joint complete with Jointing material heat Shrink type and accessories suitable for 3 ½ core XLPE, armoured, Al conductor cable of size 240 sqmm, Outdoor type complete all as specified and directed by Engr-in- Charge.
Supply and fix cable jointing kit for 1100 Volt grade cable for straight through joint complete with Jointing material heat Shrink type and accessories suitable for 3 ½ core XLPE, armoured, Al conductor cable of size 240 sqmm, Outdoor type complete all as specified and directed by Engr-in- Charge.
Checking, identifying the defect /faulty point of LT cable using Cable fault locator machine or by manual excavation and taking out bricks from the trench upto fault point along cable route and re-laying the same using old bricks/sand incl returning filling and making good surface after rectification of defect complete all as directed for the length of cable 0 - 600 mtr. Note- (i) Cable fault locator machine with all T&P required for identifying the faulty point will be arrange by contractor and the cost is included in unit rate for finding of fault using machine or by manually.
Dismantling & taking out defective LT PVC/XLPE cable from trenches with cutting and removing defective parts and supply & making cable joint using straight through joint cold shrink type and making connection of LT cables, meggering & re-storation of electric supply complete including jointing material for 240 Sqmm, 3.5 core, sizes of cable :- Joint make- Reychem Note: Rate of Jointing Kit deemed to be included in unit Rate.
S&F (in replacement) following items in the existing out door/ indoor LT panels and connection with using aluminum lugs/ferruls incl disconnection & connection of cable and making necessary alteration in panel/door using welding wk and cutting as required for proper fixing & connection complete all as specified and directed.
(a) MCCB 4pole 125 amps rating, 16 KA breaking capacity with spreader at both side
(b) MCCB 4 pole200 amps rating, 36 KA breaking capacity with spreader at both side
(c) MCCB 4 pole250 amps rating, 36 KA breaking capacity with spreader at both side
(d) Microprocessor based MCCB 400 amps rating, 36 KA breaking capacity with spreader at bothe side
(g) CTs of existing ratio and capacity fixed in LT panels and connect with ammeter
(h) Indicator lamp, LED type incl 1.5 sqmm wire for connection to desired point of bus bar.
(j) MCB TPN 100 amps, 'C' series, 415 volt
M & L for earthing complete with galvanised steel earth plate electrode 600x600x6mm thick directly buried in ground (earth pit not less than 2.25 m deep below ground level) with top edge of earth plate not less than 1.5m below the ground level connected to GI strip 32 x 6mm as earthing lead (earth strip ) by means of bolts nuts check nuts and washers of galvanised iron at 2 points & GI pipe 15 mm bore light grade for protection of earthing wire PCC chamber 1:3:6 (type C-1) using 20mm graded stone aggregate, watering pipe 20mm bore light grade, funnel with wire mesh, 50 mm thick cover of RCC 1:2:4 type B-1 using 20mm graded stone aggregate reinforced with 8 mm MS bars at 150 mm centre to centre both ways and charcoal dust and common salt all as shown in electrical plate No. 3 of MES SSR part-I and including excavation & earth work & connecting the earthing point/equipment and testing complete
Note :- Credit shown in credit schedule of tender document shall be considered by the tenderer while quoting the rates of various items. The same shall be recovered from various payment to contractor before handing over old material.
chauhan construction
M/S SWASTIK BUILDERS
Ambrish Builders
Mohit Enterprises
Bharat Trading Company
Avion Industries
M/S V K MEHROTRA
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .