Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Infra Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance | Admitted-Finance |
| 2 | Admitted-Finance | Admitted-Finance |
Tender Value
₹4.2 L
EMD Value
₹8,500
Closing Date
6 Feb 2024, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
EE Civil Pune
O/O EE Civil, BSNL Civil Dn MHS TE Pune-01
Maintenance and repairs to ITPC building at RTTC campus, Chinchwad, Pune.
2024_BSNL_183484_2
e-13/EEC(P)/BSNL/2023-24
Open Tender
Civil Works
Item Rate
120 days
RTTC CHINCHWAD
Please refer Tender documents.
3 documents required · 3 mandatory
₹590
ACCOUNTS OFFICER (Cash) BSNL Pune and payable at P
₹8,500
15 Feb 2024
29 Jan 2024
8 Feb 2024
30 Jan 2024
6 Feb 2024
30 Jan 2024
Amount
Providing and fixing in position factory made precast RCC M-40 fixing with hold fast embedded in 1:3:6 concrete block for doors and windows frames having excellent smooth finish as per IS: 6523 with reinforcement of 3 Nos, 6 mm dia main bars tied with 3 mm M.S stirrups placed @ 200 mm C/C and 6 numbers high strength polymer blocks of required size for fixing hinges including providing 6 no specially designed M.S. galvanised sleeves for accomodating 6 mm dia fully threaded bolts for fixing hold fast on vertical members, providing suitable arrangement for recieving sliding door bolts and tower bolt etc all complete, as per the direction of Engineer in charge. The frame shall be measured in running metre correct to two places of decimal. a) Door frame 100 mmx 60 mm
Providing and fixing ISI marked oxidised M.S. handles conforming to IS:4992 with necessary screws etc. complete : a) 125 mm
Providing and fixing oxidised M.S. hasp and staple (safety type) conforming to IS : 363 with necessary screws etc. complete : a) 150 mm
Repairs to aluminium door shutter by removing the shutter from its position, fixing Aluminium corner brackets of approved quality on both faces using nut & bolts of suitable size at four corners of shutter to ensure proper fixity and alignment of vertical door styles & refixing the door shutter to its original position etc. all complete as directed by Engineer-in-charge.( Cost of hinges etc if required will be paid seperatly) a) Single shutter aluminium door of size upto 1.0 x 2.10m
Taking out doors, windows and clerestory window shutters (steel or wood) including stacking within 50 metres lead: a) Of area 3 sq. metres and below
Providing and fixing aluminium die cast body tubular type universal hydraulic door closer (having brand logo with ISI, IS : 3564, embossed on the body, door weight upto 35 kg and door width upto 700 mm), with necessary accessories and screws etc. complete. a) Providing and fixing to existing door frames.
Providing and fixing to existing door frames. 30 mm thick factory made Fibreglass Reinforced Plastics (FRP) door shutter of approved make with 1.5mm thick F.R.P. Skin moulded with the Core Material forming a Sandwich Pannel, necessary wooden supports are provided for fixing the Handles, Locks, Stoppers and other accessories including SS hinges (3 Nos per door), screws etc. including taking out damaged shutter and disposal of the same also including new set of door fittings such as handles, tower bolt, door latch etc.all complete as directed by Engineer in charge.
Wall painting with acrylic emulsion paint, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre, of approved brand and manufacture, including applying additional coats wherever required, to achieve even shade and colour. a) Two coats.
Distempering with 1st quality acrylic distemper (Ready mix) having VOC content less than 50 grams/ litre of approved brand and manufacture to give an even shade : a) Old work (one or more coats)
Painting with synthetic enamel paint of approved brand and manufacture to give an even shade : a) Two or more coats.
Renewing glass panes, with putty and nails wherever necessary including racking out the old putty: a) Float glass panes of nominal thickness 4 mm (weight not less than 10kg/sqm).
Cleaning of terrace/loft water storage tank (inside surface area) upto 2000 litre capacity at all heights with coconut brushes, duster etc., removal of silt, rubbish from the tank and cleaning the tank with fresh water disinfecting with bleaching powder @ 0.5gm per litre capacity of tank, including marking the date of cleaning on the side of tank body with the help of stencil and paint and disposing of malba, all complete as per direction of Engineer-in-Charge. (The old date already written on tank should be removed with paint remover or black paint and if date is not written with the stencil or old date is not removed deduction will be made @ Rs. 0.10 per litre if during cleaning any GI fittings or ball cock is damaged that is to be repaired by contractor at his own cost and nothing extra will be paid on this account)
Cleaning of under ground sump, Over Head R.C.C. Tank (independent staging) including disposal of slit and rubbish, all as per direction of Engineer-in-Charge. The cleaning shall consist following operations:- (i) Tank shall be emptied of water by pumping & bottom shall be cleaned of slit and other deposits. (ii) Entire surface area of the sump shall then scrubbed thoroughly with wire brush etc. and pressure washed with water. (iii) Chlorination of RCC internal surface by liquid chlorine. (iv) The treated surface shall be dried using air jetting and all loose particles shall be removal from the surface. (v) Finally the surface shall be treated with ultraviolet radiation etc. as per direction of Engineer-in-Charge.
Dismantling of flushing cistern of all types C.I./PVC/Vitrious China) including stacking of useful materials near the site and disposal of unserviceable materials within 50 metres lead. including stacking of useful materials near the site and disposal of unserviceable materials within 50 metres lead.
Providing and fixing C.P. brass bib cock of approved quality conforming to IS:8931: a) 15 mm nominal bore.
Providing and fixing C.P. brass long body bib cock of approved quality conforming to IS standards and weighing not less than 690 gms. a) 15 mm nominal bore.
Providing and fixing C.P. brass stop cock (concealed) of standard design and of approved make conforming to IS:8931. a) 15 mm nominal bore.
Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:8931. a) 15 mm nominal bore.
Providing & fixing PTMT plumbing fixtures of standard make, Prayag or equivalent ncluding all required neecessary fittings, screws etc. complete as directed by Engineer in charge. a) Bib Cock/Stop Cock
b) Pillar Cock
c) Two way Cock/Angle cock
d) Shower with Lever arm
e) Health faucet with pipe and brackets
f) Handspray/hand shower with pipe and brackets
Providing and fixing P.V.C. low level flushing cistern with manually controlled device (handle lever) conforming to IS : 7231with all fittings and fixtures complete. a)10 litre capacity-white
Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete. a) Flexible pipe i) 32 mm dia
Cleaning of manholes by rodding, scrubbing and flushing to remove the clogged drain of sludge, waste & rubbish material and disposal of waste/ refuge/ filth etc. (recovered in this process) to a place permitted and approved by the Local Municipal corporation all as per the direction of Engineer-in-Charge.
Cleaning of sewer line by rodding, scrubbing and flushing to remove the clogged drain of sludge, waste & rubbish material and disposal of waste/ refuge/ filth etc. (recovered in this process) to a place permitted and approved by the Local Municipal corporation all as per the direction of Engineer-in-Charge. a)Sewer pipe line of dia. Upto 300mm.
Providing and laying APP (Atactic Polypropylene Polymer) modified prefabricated five layer, 3mm thick water proofing membrane, black finished reinforced with glass fibre matt consisting of a coat of bitumen primer for bitumen membrane @ 0.40 ltr/sqm. by the same membrane manufactured of density at 25°C, 0.87 - 0.89 kg/ltr and viscosity 70 -160 cps. Over the primer coat the layer of membrane shall be laid using butane torch and sealing all joints etc., and preparing the surface complete. The vital physical and chemical parameters of the membrane shall be as under : Joint strength in longitudinal and transverse direction at 23°C as 350/300 N/5cm. Tear strength in longitudinal and transverse direction as 60/80N. Softening point of membrane not less than 150°C.Cold flexibility shall be upto -2°C when tested in accordance with ASTM,D - 5147. The laying of membrane shall be got done through the authorised applicator of the manufacture of membrane. a) 3 mm thick
Repairs to top layer of existing water proofing treatment as detailed below: (a) Dismantling the top layer of damaged waterprrofing treatment, cleaning the surface with wire brush, broom and applying bonding coat as per the manufacturer specifications etc (b) Applying a base coat of cement slurry using 2.75kg/ sqm of cement admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge. (c) Finishing the surface with 20 mm thick jointless cement mortar of mix 1:3 (1 cement :3 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge including laying glass fibre cloth of approved quality in top layer of plaster and finally finishing the surface with trowel with neat cement slurry and making pattern of 300x300 mm square 3mm deep. (d) Curing the surface for seven days. All above operations to be done in order and as directed and specified by the Engineer-in-Charge.
Providing and fixing 12.50 mm thick tapered edge gypsum plain board to ceiling, matching with existing design over exisitng framework to a height of 5 m above floor level etc. complete as directed by Engineer In Charge.
Disposal of waste / malba by mechanical transport including loading, transporting, unloading to approved municipal dumping ground for lead upto 10 km, complete as per directions of Engineer-in-Charge. (trip of one brass ie 2.83 Cum)
Dismantling tile work in floors and roofs laid in cement mortar including stacking material within 50 metres lead. a) For thickness of tiles 10 mm to 25 mm
Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08%and conforming to IS : 15622 , of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand) jointing with grey cement slurry @ 3.3kg/sqm including grouting the joints with white cement and matching pigments etc., complete. a) Size of Tile 600x600 mm
Anoj Enterprises
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .