Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1st₹30.6 LAccepted-AOC | 1st | Accepted-AOC Being L1 | |
| 2 | 2nd₹32.3 L+₹52,697 (1.66%)Rejected-Finance | 2nd | Rejected-Finance L2 | |
| 3 | 3rd₹33.3 L+₹1.6 L (4.90%)Rejected-Finance | 3rd | Rejected-Finance L3 | |
| 4 | 4th₹34.8 L+₹3.0 L (9.54%)Rejected-Finance | 4th | Rejected-Finance L4 | |
| 5 | 5th₹37.2 L+₹5.4 L (17.1%)Rejected-Finance 19 SAINIK COLONY BAIRAGARH BHOPAL MP 462 030 | BHOPAL | MADHYA PRADESH | 462030 | 5th | Rejected-Finance L5 |
Tender Value
₹40 L
EMD Value
₹80,000
Closing Date
17 Apr 2023, 6:00 pmClosed
GE AWC MHOW
GE AWC MHOW
REPAIR/REPLACEMENT AND MAINT OF EXISTING UNSERVICEABLE SWITCHES , SOCKETS, INTERNAL WIRING, SUBMAIN WIRING, OLD CFL/FTL FITTINGS, DISTRIBUTION BOARDS AND OTHER ALLIED WORKS AT KLP LOCATION OF AWC ( INCLUDING CAMP AREA AND DEMO SQN ) UNDER GE (AWC), M
2023_MES_586495_1
8645 GE(AWC) /MHOW / OF 2023-24
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
GE AWC MHOW
All as per NIT and Tender Documents
7 documents required · 7 mandatory
₹500
Yes
GE AWC MHOW
₹80,000
Yes
6 May 2023
21 Mar 2023
18 Apr 2023
21 Mar 2023
17 Apr 2023
4 Apr 2023
Amount
Taking down carefully copper / aluminium point wiring (light, fan, sockets or power) complete including all fittings and fixtures such as switches, sockets, ceiling roses, pendents, regulators, light fittings etc, removing materials to store for taking credit and making good disturbed surfaces complete all as specified and directed.
M&L point wiring with 1.5 sqmm (nominal cross sectional area) single core, PVC insulated, unsheathed FRLSH copper cable, 1100 volts grade, with multi stranded copper conductor drawn through and including non-metallic, rigid non metallic PVC conduit (medium grade) concealed in wall / ceiling with and including 1.5 sqmm single core PVC insulated, multistranded, unsheathed, FRLSH copper conductor cable as continuous earth continuity conductor (green in colour) with cast Iron / pressed steel modular terminal boxes any size/module, concealed on walls and fixed by means of brass screws incl modular cover plates and cover frame any size/module and blank plates, for mounting or housing switches, socket outlets, fan regulators, etc. including all other fixing accessories for one light / fan / exhaust fan / call bell point controlled by one 5 / 6 Amps switch, complete incl making good of wall surface by cementing/plastering , applying wall putty incl 02 coat of distempering to match with the existing colour complete all as specified and directed.
Description same as per Item No. 02.00 above but for one 3 pin, 5/6 Amps socket outlet point on same board controlled by one, 1 way 5/6 Amps switch complete all as specified and directed.
Description same as per Item No. 02.00 above but for one 3 pin, 5/6 Amps socket outlet point on independent board controlled by one, 1 way 5/6 Amps switch complete all as specified and directed.
Description same as per Item No. 02.00 above but for one light point controlled by one, 2 way 5/6 Amps switch complete all as specified and directed.
M&L point wiring with 2.5 sqmm (nominal cross sectional area) single core, PVC insulated, unsheathed FRLSH copper cable, 1100 volts grade, with multi stranded copper conductor drawn through and including non-metallic, rigid non metallic PVC conduit (medium grade) concealed in wall / ceiling with and including 2.5 sqmm single core PVC insulated, multistranded, unsheathed, FRLSH copper conductor cable as continuous earth continuity conductor (green in colour) with cast Iron / pressed steel modular terminal boxes any size/module, fixed concealed in walls by means of brass screws incl modular cover plates and cover frame any size/module, for housing switches, socket outlets, fan regulators, etc. including all other fixing accessories for 15 / 16 Amps socket outlet on independent board, complete incl making good of wall surface by cementing/plastering , applying wall putty incl 02 coat of distempering to match with the existing colour complete all as specified and directed.
M&L point wiring with 1.5 sqmm (nominal cross sectional area) single core, PVC insulated, unsheathed FRLSH copper cable, 1100 volts grade, with multi stranded copper conductor drawn through PVC casing and caping of suitable sizes (medium grade ISI marked ) in wall / ceiling with and including 1.5 sqmm single core PVC insulated, multistranded, unsheathed, FRLSH copper conductor cable as continuous earth continuity conductor (green in colour) with cast Iron / pressed steel modular terminal boxes any size/module, concealed on walls and fixed by means of brass screws incl modular cover plates and cover frame of any size/module, for mounting or housing switches, socket outlets, fan regulators, etc. including all other fixing accessories for one light / fan / exhaust fan / call bell point controlled by one 5 / 6 Amps switch, complete incl making good of wall surface by cementing/plastering , applying wall putty incl 02 coat of distempering to match with the existing colour complete all as specified and directed.
Description same as per Item No. 07.00 above but for one 3 pin, 5/6 Amps socket outlet point on same board controlled by one, 1 way 5/6 Amps switch complete all as specified and directed.
Description same as per Item No. 07.00 above but for one 3 pin, 5/6 Amps socket outlet point on independent board controlled by one, 1 way 5/6 Amps switch complete all as specified and directed.
Description same as per Item No. 07.00 above but for one light point controlled by one, 2 way 5/6 Amps switch complete all as specified and directed.
M&L point wiring with 2.5 sqmm (nominal cross sectional area) single core, PVC insulated, unsheathed FRLSH copper cable, 1100 volts grade, with multi stranded copper conductor drawn through and including rigid,non-metallic PVC casing and caping (medium grade) on wall / ceiling with and including 2.5 sqmm single core PVC insulated, multistranded, unsheathed, FRLSH copper conductor cable as continuous earth continuity conductor (green in colour) with cast Iron / pressed steel modular terminal boxes any size/module, fixed concealed in walls by means of brass screws incl modular cover plates and cover frame any size/module, for housing switches, socket outlets, fan regulators, etc. including all other fixing accessories for 15 / 16 Amps socket outlet on independent board, incl making good of wall surface by cementing/plastering , applying wall putty incl 02 coat of distempering to match with the existing colour complete all as specified and directed.
S&F in repair Ceiling rose 3 terminal AC 230 V, 50 Hz ISI Marked all as specified and directed.
S&F in repair modular switch 1 way 6A, 1 module, ISI Marked complete all as specified and directed.
S&F in repair modular switch 2 way 6A, 1 module, ISI Marked complete all as specified and directed.
S&F in repair modular bell push one way, 5/6 Amp, 240 V ISI Marked complete all as specified and directed.
S&F in repair modular switch 1 way 16A, 1 module, ISI Marked complete all as specified and directed.
S&F modular socket outlet, 6A - 2/3 pin combined 2 module, ISI Marked complete all as specified and directed.
S&F modular socket multipurpose 6/16A, 2 module, ISI Marked complete all as specified and directed.
S&F stepped type electronic modular fan regulator - 2 module, with 5 step, AC 50 Hz, 230/240 Volts grade, ISI Marked complete all as specified and directed.
S&F call bell, ding dong, AC 230 V, 50 Hz complete all as specified and directed.
S&F TV socket outlet ISI Marked complete all as specified and as directed.
S&F RJ 11 /RJ 45 LAN jack with shutter ISI Marked complete all as specified and as directed.
S&F modular type angular lamp holder, PVC / Polycarbonate fancy type with back plate 230 V, 50 Hz including taking down complete all as specified and as directed.
S&F in repair of pendent lamp holder, brass body for decorative wall fittings complete with mounting clamp (as per sample) for fixing inside wall mounted luminaire 240 volt complete all as specified and as directed.
S&F in repair metal plug and socket DB concealed in wall, double pole 240 volts and including one 20 Amp MCB SPN, C-Curve, ISI Marked complete incl making good of disturbed surface by plastering, painting, applying putty all as specified and directed.
S&F in repair 9 watt LED lamp (5 star rated) with B22 base including taking down complete all as specified and as directed.
S&F in repair surface / wall mounted LED batten (other than slim channel type) poly carbonate housing for retrofit LED tube T-8 type up to 1x22 watt, 4 feet long pre wired incl integrated electronic driver complete with all connected accessories complete all as specified and directed.
S&F in repair ultra bright LED poly carbonate tube light 4 feet long 18 to 20 watts with THD less than 15% very high efficiency suited for T-8 tube light luminaire with system efficiency 120 lumens per watts. High quality polycarbonate end cap in white finish and snap fitted to the housing complete all as specified and directed.
S&F in repair decorative ultra slim poly carbonate LED tube light fitting 4 feet long 22 watts with THD less than 15% very high efficiency suited for T-8 tube light luminaire with system efficiency 110 lumens per watts. High quality polycarbonate end cap in white finish and snap fitted to the housing complete all as specified and directed.
S&F in repair wall mounted 10 watts LED batten 2 feet long comprising extruded aluminium heat shrink provided for efficient heat dissipation & integrated electronic driver with aluminium housing system efficiency of 110 lumen per watt and lumen package ≥1100 lumen, THD < 10% complete all as specified and directed.
M&L for LED Bulk head fittings of wattage 6 to 13 watts designed for modern homes available with premium quality diffuser for glare free light and easy to install snap fit installer complete including taking down of old CFL/bulb bulk head fitting, making good of surfaces all as specified and directed.
S&F wall mounted decorative luminaire, SS finish fixture with opal glass diffuser suitable for 8/9 watts LED, designed for modern homes, glare free light and easy to install snap fit installer complete including taking down of old CFL/bulb wall fittings making good of surfaces all as specified and directed.
S&F in repair LED bldg. security light fitting 30 watts made up of pressure die cast aluminium housing with acrylic cover as diffuser with IP-65 and IK-07 protection, THD < 10% , lumen output ≥ 110 lumen per watt complete all as specified and directed.
S&F in repair GI mounting pipes of building security light fittings of size 32 mm to 40 mm size up to 1.2 mtr length bend into sizes incl mounting clamps, saddles, nut bolt and washers all as specified and directed.
S&F in repair recess mounted downlight 18 watts 224 mm dia with white powder coated polycarbonate housing and pressure die-cast heat sink having high efficiency with heavy duty driver of lumen out put colour off white/yellow incl making good of ceiling / POP ceiling all as specified and directed.
S&F in repair repairs sleek round surface mounting LED down light 18 Watts with cover frame, 23 V, 50 Hz , 220 mm dia complete with Aluminium die cast body, finish with drop down PC diffuser to deliver low glare illumination with optimised heat sink for efficient heqat dissipation complete incl electronic driver, outer cover all as specified and directed.
S&F recess mounted downlight 6 watts 105 mm dia with white powder coated polycarbonate housing and pressure die-cast heat sink having high efficiency with heavy duty driver as per sample all as specified and directed.
S&F in repair recess mounted downlight square type 12 watts 150 mm size with white powder coated polycarbonate housing and pressure die-cast heat sink having high efficiency with heavy duty driver complete all as specified and directed.
S&F in repair recess mounted downlight square type 18 watts 180 mm size with white powder coated polycarbonate housing and pressure die-cast heat sink having high efficiency with heavy duty driver complete all as specified and directed.
S&F VTPN DB, 06 way, IP- 43, IK 09, double door type with metal door, suitable for fixing up to 3 pole 160 Amp MCCBs as incomer and SP/TP MCB/Isolator as outgoing, including taking down, fixing flush to wall & making good the disturbed surfaces complete all as specified and as directed.
S&F MCB DB, TPN 4 way, IP-43, IK 09, double door type with metal door, 415 V, 50 Hz, suitable for fixing MCB TPN as incomer and SP/TP MCB/Isolator as outgoing, including taking down old DB with MCBs, fixing flush to wall & making good the disturbed surfaces complete all as specified and as directed.
S&F MCB DB, SPN 8 way, IP-43, IK 09, double door type with metal door, 230 V,50 Hz suitable for fixing MCB SPN as incomer and SP MCB/Isolator as outgoing, including taking down old DB with MCBs, fixing flush to wall & making good the disturbed surfaces complete all as specified and as directed.
S&F MCCB 3 pole 160 Amps breaking capacity 25 KA, Ics = 100% Icu including spreader link & taking down complete all as specified and directed.
S&F in repair MCCB 3 pole 100 Amps breaking capacity 25 KA, Ics = 100% Icu including spreader link complete all as specified and directed.
S&F MCB TPN 32 Amps,10 KA breaking capacity, 'C' curve complete all as specified and directed.
S&F MCB TPN 63 Amps,10 KA breaking capacity, 'C' curve complete all as specified and directed.
S&F MCB SPN 20 to 32 Amps,10 KA breaking capacity, 'C' curve complete all as specified and directed.
S&F MCB SPN 40 Amps,10 KA breaking capacity, 'C' curve complete all as specified and directed.
S&F MCB SP 6 to 32 Amp, 10 kA breaking capacity, 'C' curve complete all as specified and as directed.
M&L for MCB two way centre off change over switch 40 Amps, for duel electricity supply management complete all as specified and directed.
M&L for 20A DP energy saving switch (with key tag) 3 module complete all as specified and directed. Note For item no. 40 to 51 - Make of all items should be same.
M & L sub main wiring with 2 runs of 6 sqmm main wire along with 1 run of 6 sqmm earth wire (green in colour) single core FRLSH PVC insulated, unsheathed, multi-stranded, 1100 volts grade ISI marked copper conductor cable, drawn through and including adequate size rigid non-metallic PVC concealed / surface conduit (medium grade) wherever necessary with all fittings & accessories including cutting chases for conduits as required, sinking for terminal boxes, making good the same & taking down complete all as specified and directed. NOTE:- Two runs of main copper conductor, one run of earth wire and one run of PVC conduit shall be measured as one unit length.
Description same as per Item No. 52.00 here in above but with 2 runs of 4 sqmm main wire along with 01 runs of 4 sqmm earth wire complete all as specified and directed.
Description same as per Item No. 52.00 here in above but with 2 runs of 10 sqmm main wire along with 01 runs of 6 sqmm earth wire complete all as specified and directed.
Description same as per Item No. 52.00 above but with 4 runs of 10 sqmm main wire along with 2 runs of 6 sqmm earth wire complete all as specified and directed.
M&L for flexible wire twisted 23/0076 of size 1.5 sq. mm in repair from ceiling rose to light fittings/ceiling fan/exhaust fans complete all as specified and directed.
S&F in repair 3 core copper flexible cable 2.5 sqmm complete all as specified and directed.
M&L for removing and refixing LED tube light fitting before and after point wiring with screws, connecting clips all as specified and as directed.
S&F in repair PVC insulated, unsheathed FR copper cable, 1100 volts grade, with multi stranded copper conductor 4 core, 6.0 sqmm, 1100 volt complete all as specified and directed.
M&L for replacement of FRP junction box three terminal and neutral with one MCB SP 20 A for control of security light / garden light / gates / post top lantern incl making good of PCC and finishing with cement rendering complete all as specified and directed.
M&L cement concrete 1:3:6 type C2 using 40mm graded stone aggregate in foundations, filling and mass concrete, incl necessary form work, finishing with cement mortar 1:4 externally 15mm thick after removal of form work complete all as specified and directed.
Supply only batteries of capacity 12 volts 18 AH, Dry type for ARD device all as specified and as directed.
Supply only batteries of capacity 12 volts 7.2 AH, Dry type for ARD device all as specified and as directed.
M&L in repair Mini MCB 6 to 32 Amps , 23 volts, 50 Hz all as specified and directed.
M&L for Blank Plate 01 Module complete all as specified and directed.
M&L in repair change over MCB 4 pole 63 Amps, 415 volts, 50 Hz all as specified and as directed.
Supply only cross flow fan, 200mm sweep metallic body as per sample all as specified and directed.
M&L in repair GI tubings 50 mm size light grade for cable protection/stand post of garden lights incl welding bending complete all as specified and directed.
M&L for bollard 09 watts made of extruded aluminium housing for land scaping with better light quality and enhance architectural design IP 65 protection, fixing in PCC foundation with suitable nut bolt and washers complete all as specified and as directed.
Supply and fix of ceiling fan 1200 mm sweep with wattage < = 50 watt and air delivery >= 220 Cum/ minimum with electronic modular type fan regulator 1 or 2 modular complete all as specified and as directed.
Excavation in trenches not exceeding 1.5 meter depth and 1.5 meter in width in loose/ soft soil for laying of cable/errection of pole getting out soil complete all as specified and directed.
Returning filling incl spreading , levelling, watering and well ramming in layers not exceeding 25 cm complete all as specified and directed.
Removing excavated materials not exceeding 50 mtr and depositing where directed at a level not exceeding 1.5 mtr above the starting point complete all as specified and directed.
M&L for repair of fire pumps Kirloskar make, 35 HP,2280 LPM, at 2150 RPM by removing the pump assembly carefully from fire engine, removing the MS coupling, taken to work shop in repair brass impellor of existing size, incl necessary grinding, lathe work for main shaft, refixing/ recoupling the pump with existing engine fly wheel, alignment of MS coupling, checking the RPM to deliver out put water pressure as per deigned parameters of pump all as specified and directed . Note: 1. The rates are inclusive of all item incl impellors, MS couplings, nut, bolt, washers and gaskets . 1. Rate incl all transportation charges. 2. Area of work : Amn dump ( 08 km from AGE E/M-II) 3. Necessary entry passes required for entry of each persons
M&L in repair foot valve 100 mm size, CI body by taken out suction line of fire pumps incl testing all as specified and directed.
M&L in repair Flexible rubber hose pipe line 100 mm size designed for high pressure min 8 bar incl removing old rubber hose from suction line of fire pumps incl testing all as specified and directed.
M&L Earthing complete with galvanised steel earth plate electrode of size 600 x 600 x 6 mm thick buried directly in ground in vertical position (earth pit not less than 2.25 m deep below the normal ground level) with top edge of the earth plate not less than 1.5 m below normal ground level, connected to GI earth wire 4 mm dia by means of bolts, nuts, check nuts and washers of , all as shown in electrical plate No. 3 connected to earthing test point and complete all as specified and directed. Note:- The unit rate shall also include for earth work in any type of soil, PCC 1:3:6 type C-1 (using 20 mm grade crushed stone aggregate) earth chamber, RCC 1:1.5:3, type A-1 cover slab, 40 mm thick reinforced with 6 mm dia TMT bar @ 150 mm C/C both ways, 10 mm dia plain bar lifting handle embedded in cover slab, 20 mm bore medium grade GI watering pipe, 15 mm bore GI light grade earth lead protection pipe, funnel, wire mesh, copper lugs, charcoal and common salt in alternate layer etc.
Vinayak Trading House
Raj Contruction
Auto Traders
SUNIL ENTERPRISE
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .