Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹67.3 LAccepted-AOC VILL JAMALPUR P O NAYA MAHMMADPUR DISTT BHOJPUR ARA PIN 802163 | ARA | BHOJPUR | BIHAR | 802163 | ₹67.3 L Quoted ₹68.9 L | 1 | Accepted-AOC Lowest bidder |
| 2 | 2₹69.9 L+₹95,348 (1.38%)Rejected-Finance OPP BSF GATE NO 3 AZARA GUWAHATI 17 ASSAM | ₹69.9 L+₹95,348 (1.38%) | 2 | Rejected-Finance Not Being Lowest |
| 3 | 3₹87.7 L+₹18.8 L (27.3%)Rejected-Finance AZARA BHARALIPARA NEAR AZARA PUBLIC HALL GUWAHATI 781017 ASSAM | KAMRUP METRO | ASSAM | 781017 | ₹87.7 L+₹18.8 L (27.3%) | 3 | Rejected-Finance Not Being Lowest |
| 4 | 4₹95.0 L+₹26.1 L (37.9%)Rejected-Finance | ₹95.0 L+₹26.1 L (37.9%) | 4 | Rejected-Finance Not Being Lowest |
| 5 | Rejected-Technical HOUSE NO 2 SATGAON MAIN ROAD NEAR BAILEY WATER FACTORY P O UDAYAN VIHAR DIST KAMRUP METRO GUWAHATI ASSAM 781171 | GUWAHATI | KAMRUP METRO | ASSAM | 781171 | - | - | Rejected-Technical Not admitted as firm is one class below eligible class and present work load of firm is more than 05 times the tendering limit. |
Tender Value
₹99 L
EMD Value
₹1.7 L
Closing Date
3 Oct 2022, 6:00 pmClosed
CWE SHILLONG
HQ CWE SHILLONG SE FALLS SHILLONG
CERTAIN REPAIR TO INTERNAL ELECTRIFICATION WORKS TO MD ACCN AT PHASE-I AND PHASE-II AREA UNDER GE NARANGI
2022_MES_545984_1
8580/NAR/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
NARANGI
Please refer Tender documents.
8 documents required · 8 mandatory
₹1,000
GE NARANGI
₹1.7 L
Yes
15 Nov 2022
23 Aug 2022
4 Oct 2022
23 Aug 2022
3 Oct 2022
18 Sept 2022
Amount
Taking down copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc. removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc. complete all as specified and directed.
Material and Labour Point wiring with PVC insulated and unsheathed cable single core multistranded copper conductor 1.5 sqmm size, 1100 volts, FRLS grade cable conforming to IS-694 1990 drawn in and including PVC Casing and Caping with all accessories including fabricated MS/PVC terminal boxes fixed flush with wall surface with 3mm thick masonite laminated sheet top cover fixed with brass screw for mounting switches, sockets, regulator etc including 1.5 sqmm single core PVC insulated and unsheathed copper conductor earth continuity conductor to common earth and connecting to earth dolly all as specified for One light or fan point controlled by one 5 Amps switch one way complete all as specified and directed.
All as per item No 2 here-in-before but One bell/buzzer point controlled by one push button on the same board with other switches or independent with cables complete all as specified and directed.
All as per item No 2 here-in-before but for One 3 pin 5 Amp switch socket outlet on independent board complete all as specified and directed.
All as per item serial No 2 here-in-before but for One 3 pin 5 Amp socket outlet on same board with other switches complete all as specified and directed.
All as per item No 2 here-in-before but wiring with 2.5 sqmm size single core multistranded copper conductor cable for 6 pin 15 Amps switch socket combination outlet on independent board with 2.5 sqmm PVC insulated and unsheathed copper conductor as earth and connected to earth dolly complete all as specified and directed.
Material and Labour Point wiring with PVC insulated and unsheathed cable single core multistranded copper conductor 1.5 sqmm size, 1100 volts, FRLS grade cable conforming to IS-694 1990 drawn in and including PVC Conduit with all accessories including fabricated MS/PVC terminal boxes fixed flush with wall surface with 3mm thick masonite laminated sheet top cover fixed with brass screw for mounting switches, sockets, regulator etc including 1.5 sqmm single core PVC insulated and unsheathed copper conductor earth continuity conductor to common earth and connecting to earth dolly all as specified for One light or fan point controlled by one 5 Amps switch one way complete all as specified and directed.
All as per item No 7 here-in-before but One bell/buzzer point controlled by one push button on the same board with other switches or independent with cables complete all as specified and directed.
All as per item No 7 here-in-before but for One 3 pin 5 Amp switch socket outlet on independent board complete all as specified and directed.
All as per item serial No 7 here-in-before but for One 3 pin 5 Amp socket outlet on same board with other switches complete all as specified and directed.
All as per item No 7 here-in-before but wiring with 2.5 sqmm size single core multistranded copper conductor cable for 6 pin 15 Amps switch socket combination outlet on independent board with 2.5 sqmm PVC insulated and unsheathed copper conductor as earth and connected to earth dolly complete all as specified and directed.
All as per item No 2 here-in-before but wiring with 4 sqmm size single core multistranded copper conductor cable for 6 pin 15 Amps switch socket combination outlet on independent board with 4 sqmm PVC insulated and unsheathed copper conductor as earth and connected to earth dolly complete all as specified and directed.
Supply and fixing switch piano, flush type single pole one way 5 Amps 230 volt complete all as specified and directed.
Supply and fixing Bell push switch, flush type, 5 Amps 230 volt complete all as specified and directed.
Supply and fixing socket outlet 3 pin, 2-in-1, 5 Amps flush type complete all as specified and directed.
Supply and fixing switch socket combination outlet 5 pin, 2-in-1, 5 Amp flush type complete all as specified and directed.
Supply and fixing switch socket combination multipurpose, 2 in 1, 6 pin, 5 & 15 Amp flush type complete all as specified and directed.
Supply and fixing ceiling rose surface bakelite 65x50mm three terminals complete all as specified and directed.
Supply and fixing lamp holder insulated PVC/ Polycarbonate/ bakelite body, with back plate suitable for batten fitting or PVC round or square box, complete all as specified and directed.
Supply and fixing stepped type electronic fan regulator, two module size, flush type complete all as specified and directed.
Supply and fixing Buzzer, Ding Dong AC. 230 volts,single pole complete all as specified and directed.
Supply and fixing Bell, AC, 230 volts, single pole complete all as specified and directed.
Supply and fixing Single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB 20 Amp 240 V complete all as specified and directed.
Material and Labour for submain wiring with 2 runs of 1.5 sqmm, single core,FR-LSH PVC insulated & unsheathed cable conforming to IS-694, 1100 volts with copper conductor multi stranded drawn in and including 20mm dia non metallic PVC grey conduit with all accessories such as Tees, Elbows, junction box, reducers etc as requied alongwith one run of 1.5 sqmm single core FR-LSH PVC insulated & unsheathed copper conductor as continuos earth wire dolly and connecting to existing main switch board / distribution board of each building / qtr as ordered and testing on completion including taking down old wiring and type of conduit complete all as specified and directed. Note: 2 runs of 1.5 Sqmm cable and 1 run of 1.5 Sqmm cable along with conduit altogether shall be measured as one unit.
Material and Labour for submain wiring with 2 runs of 2.5 sqmm, single core,FR-LSH PVC insulated & unsheathed cable conforming to IS-694, 1100 volts with copper conductor multi stranded drawn in and including 20mm dian non metallic PVC grey conduit with all accessories such as Tees, Elbows, junction box, reducers etc as requied alongwith one run of 2.5 sqmm single core FR-LSH PVC insulated & unsheathed copper conductor as continuos earth wire dolly and connecting to existing main switch board / distribution board of each building / qtr as ordered and testing on completion including taking down old wiring and type of conduit complete all as specified and directed. Note: 2 runs of 2.5 Sqmm cable and 1 run of 2.5 Sqmm cable along with conduit altogether shall be measured as one unit.
Material and Labour for Sub main wiring with 2 runs of 4.0 sqmm, single core,FR-LSH PVC insulated & unsheathed cable conforming to IS-694, 1100 volts with copper conductor multi stranded drawn in and including 20mm dian non metallic PVC grey conduit with all accessories such as Tees, Elbows, junction box, reducers etc as requied alongwith one run of 4.0 sqmm single core FR-LSH PVC insulated & unsheathed copper conductor as continuos earth wire dolly and connecting to existing main switch board / distribution board of each building / qtr as ordered and testing on completion including taking down old submain wiring and type of conduit complete all as specified and directed. Note: 2 runs of 4 Sqmm cable and 1 run of 4 Sqmm cable along with conduit altogether shall be measured as one unit.
Material and Labour for Sub main wiring with 2 runs of 6.0 sqmm, single core,FR-LSH PVC insulated & unsheathed cable conforming to IS-694, 1100 volts with copper conductor multi stranded drawn in and including 20mm dian non metallic PVC grey conduit with all accessories such as Tees, Elbows, junction box, reducers etc as requied alongwith one run of 6.0 sqmm single core FR-LSH PVC insulated & unsheathed copper conductor as continuos earth wire dolly and connecting to existing main switch board / distribution board of each building / qtr as ordered and testing on completion including taking down old submain wiring and type of conduit complete all as specified and directed. Note: 2 runs of 6 Sqmm cable and 1 run of 6 Sqmm cable along with conduit altogether shall be measured as one unit.
Supply and fixing in repair batten type LED light fitting 1x 20W, 220V,AC decorative type with internal SPD upto 4kV and overload voltage protection upto 440V including flexible copper conductor cable of suitable size from ceiling rose complete all as specified and directed.
Supply and fixing in repair wall mounted decorative luminaire in design mesh suitable for 7W LED lamp B22 base ,including lamp of 7watt complete all as specified and directed.
Supply and fixing in repair LED (double sided connection) ) ultra bright polycarbonate tube rod 18/20 watt retrofit in existing box type tube light complete all as specified and directed.
Supply and fixing in repair LED light fitting 1x9W/1X10Wbulkhead luminaires including LED light driver holder connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed.
Material and Labour for plate earthing complete with galvanized mild steel plate electrode 60 cm x 60 cm x 6 mm thick buried directly in ground vertically (in earth pit not less than 2.25 m deep below normal ground level) with the top edge of the earth plate at a depth not less than 1.5 m below normal ground level, the earth electrode surrounded by adequate quantity of charcoal dust and salt to a packed thickness of 15 cm on all sides and incl GI earth lead wire 4 mm dia or 8 SWG bolted (with GI nuts, bolts & check nuts) and earth plate electrode at one end and connected to main switch board/ DBs etc. at the other, earth strip encased(protected) in and including 15 mm bore GI pipe medium grade with all fittings from top of electrode to main switch board/ DBs etc fixed with and including 25 x 6mm flat iron clamps, bolts, nuts and washer and also including providing watering pipe 20mm bore GI pipe medium grade from bottom of earth pit to top of electrode complete with earth pit in PCC 1:2:4 type B-2 using 40 mm graded stone aggregate, RCC cover, funnel, wire mesh including necessary excavation and earth work complete all as specified and shown in electrical plate No 3 of SSR Pt-I.
Taking down ceiling fan 1400mm /1200mm sweep ,sealing cable end ,dismantling blade & removing the same and refixing on same location or other location of any type/make and size carefully from fan hook, and transporting from any location in side army area to MES E/M store yard and back after repairing complete all as specified and directed.
M & L for painting of ceiling/exhaust fan complete with blades ,in situ with synthetic enamel paint by spraying including filling cavities with filler ,ones coat after cleaning all dust etc.complete all as per directed by Eng-in -charge.
Rewinding Ceiling fan by cutting the existing copper winding of ceiling fan 1200/1400 mm sweep and make any type with super enamelled copper wire of suitable size incl all insulating materials varnishing and heating complete incl satisfactory testing of fan on full load to entire satisfaction of Engineer-in-Charge complete all as specified and directed.
Rewinding Ceiling fan by cutting the existing copper winding of ceiling fan Heavy Duty old model 1200/1400 mm sweep and make any type with super enamelled copper wire of suitable size incl all insulating materials varnishing and heating complete incl satisfactory testing of fan on full load to entire satisfaction of Engineer-in-Charge complete all as specified and directed.
Supply and fixing in repair fan bearing of size 6201/6202 suitable for ceiling fan 1200/1400mm sweep complete all as specified and directed.
Supply only rubber reels incl shackle clamp, bolts, nuts, washers split pins of appropriate size as required complete all as specified and directed
Supply only down rod made of 15mm bore GI pipe heavy duty 45 cm long incl machining/ threading/drilling hole of size suitable for nuts and bolts washer and split pin suitable for any size and make of fan complete all as specified and directed.
Supply only plastic canopy upper & lower of any size and make of ceiling fan fixed with suitable size of screws complete all as specified and directed.
Taking down exhaust fan of size 200mm to 400mm sweep of any make and refixing on same location or other location carefully from site & transporting from any location inside Army area to MES E/M store yard for stripping of fan washing thoroughly of bearing/bush by petrol, washing fan blade body etc thoroughly provision of new greasing replacement of worn out/defective unserviceable parts (wherever necessary) assembling the same incl provn of twisted twin core flexible wire upto 0.7 mtrs long size 24/0, 020 (ISI marked) and testing the fan on full load to entire satisfaction of Engineer-in-Charge complete all as specified and directed. Note :- (i) Defective/unserviceable parts replaced will be paid separately in respective item of Sch 'A' as Supply only. (ii) The cost of taking down unserviceable parts included in this item.
Rewinding the armature for 200mm to 400mm sweep exhaust / wall fan any make with super enamelled copper wire of suitable size with and including all insulating materials varnishing complete all as specified and directed.
Supply and fixing in repair ball bearing of size suitable for exhaust/wall fan upto 400 mm sweep complete all as specified and directed. (Make : NBC/SKF/SBBI)
Supply and fixing in repair for condenser ISI marked 230/240/250 volts AC 4 MFD suitable for exhaust fan incl condenser spacer and soldering of condenser wire to fan wire and fixing (Make : Usha/Asian/EPCOS).
Supply and fixing in repair of unsv switch piano, flush type single pole one way 5 Amps 230 volt complete all as specified and directed.
Supply and fixing in repair of unsv switch flush type 15 Amp single pole one way complete all as specified and directed.
Supply and fixing in repair of unsv socket outlet 3 pin, 2-in-1, 5 Amps flush type complete all as specified and directed.
Supply and fixing in repair of unsv switch socket combination outlet 2-in-1, 5 Amp flush type complete all as specified and directed.
Supply and fixing in repair of unsvr switch socket combination multipurpose, 2 in 1, 3 pin, 5 & 15 Amp flush type complete all as specified and directed.
Supply and fixing in repair of unsv socket outlet 3 Pin 15 Amp 240 volts complete all as specified and directed.
Supply and fixing in repair of unsv ceiling rose surface bakelite 65x50mm three terminal complete all as specified and directed.
Supply and fixing in repair of unsv lamp holder insulated PVC/Polycarbonate/bakelite body, with back plate suitable for batten fitting or PVC round or square box, complete all as specified and directed.
Supply and fixing in repair of unsv stepped type electronic fan regulator, two module size, flush type complete all as specified and directed.
Supply and fixing in repair of unsv fan capcitor 2.5 Mfd suitable for 1200/1400mm sweep ceiling fan complete all as specified and directed.
Supply and fixing in repair for factory made, sheet steel distribution boards, TPN, 4 Way, double door,with provision for FP MCB as incomer and SP MCBs as outgoing complete and grouted in wall with PCC(1:2:4) type B-1 using 20 mm graded stone aggregate complete all as specified and directed.
Supply fix in repair MCB DB of sheet metal enclosure double door SPN 8 way with 200 A rated bus bar and grouted in wall with PCC(1:2:4) type B-1 using 20 mm graded stone aggregate complete all as specified and directed.
Supply fix in repair MCB DB of sheet metal enclosure double door SPN 4 way with 200 A rated bus bar and grouted in wall with PCC(1:2:4) type B-1 using 20 mm graded stone aggregate complete all as specified and directed..
Supply fix in repair MCCB DB IP-43 of sheet metal enclosure double door VTPN 4 way with 250 Amps rated copper bus bar 415 volt and grouted in wall with PCC(1:2:4) type B-1 using 20 mm graded stone aggregate complete all as specified and directed.
Supply and fixing in repair MCBs, SP 6 to 32 Amps In accordance with IS/IEC 60898-1, 240 V, 50 Hz, 10 kA ,C-series marked fixing in DBs (DBs catered separately in this Schedule) complete all as specified and directed.
Supply and fixing in repair MCBs, SPN 32 Amps In accordance with IS/IEC 60898-1, 240 V, 50 Hz, 10 kA ,C-series marked fixing in DBs (DBs catered separately in this Schedule) complete all as specified and directed.
Supply and fixing in repair MCB triple pole & neutral 40 to 100 Amps in accordance with IS/IEC 60898-1, 415 V, 50 Hz,10 kA,C-series rupturing capacity providing in DB complete all as specified. complete all as specified and directed.
Supply and fixing in repair for MCCBs 415 V, 16 KA, 4P, upto 40-63 Amps complete all as specified and directed.
Supply and fixing in repair for MCCBs 415 V, 16 KA, 4P, upto 100-125 Amps complete all as specified and directed.
Supply and fix in repair modular fan regulator,120 W, 2 module complete all as specified and directed.
Supply and fixing in repair modular switch 1 way 6 amp, 1 module complete all as specified and directed.
Supply and fixing in repair modular switch 1 way 16 amp, 1 module complete all as specified and directed.
Supply and fixing in repair modular switch 2 way 6 amp, 1 module complete all as specified and directed.
Supply and fixing in repair modular socket, 6 Amp 2/3 pin combined, 2 module complete all as specified and directed.
Supply and fixing in repair modular socket, 16 Amp 2/3 pin combined, 2 module complete all as specified and directed.
Supply and fixing in repair modular Bell push 6A, 1 module complete all as specified and directed.
Supply and fixing in repair modular white cover plate with frame, 1 module complete all as specified and directed.
Supply and fixing in repair modular white cover plate with frame, 2 module complete all as specified and directed.
Supply and fixing in repair modular white cover plate with frame, 3 module complete all as specified and directed.
Supply and fixing in repair modular white cover plate with frame, 4 module complete all as specified and directed.
Supply and fixing in repair modular white cover plate with frame, 6 module complete all as specified and directed.
Supply and fixing in repair modular white cover plate with frame, 8 module complete all as specified and directed.
Supply and fixing in repair metal flush box 1/2 module for modular switches complete all as specified and directed.
Supply and fixing in repair metal flush box 3 module for modular switches complete all as specified and directed.
Supply and fixing in repair metal flush box 4 module for modular switches
Supply and fixing in repair metal flush box 6 module for modular switches complete all as specified and directed.
Supply and fixing in repair metal flush box 8 module for modular switches complete all as specified and directed.
Dressing of pre-wired casing caping/PVC conduit by changing Casing caping /PVC conduit and necessary connecting items (such as flexiable conduit ,screws etc) complete all as specified and directed.
Supply and fixing in repair LED luminaire 600 mm x 600 mm, 35/36 watt, 220 V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complete all as specified and directed.
Supply and fixing in repair 15 watt LED recessed mounted luminaire with high brightness LED for glare-free homogenous illumination suitable for Armstrong/grid ceiling and fixture size in mm (LxWxH) 295x295x70 complete all as specified and directed.
Supply and fixing in repair LED 35 W building secruity light made up of pressure die cast housing with high efficient LED as lighting source and PC cover having TOP Opening separate driver compartment with IP66 protection and impact resistance of IK07 and suitable for dia upto 43 mm complete all as specified and directed.
Material and Labour for GI bracket made out of 40 mm bore medium grade GI Pipe with two sets clamps, with nuts and bolts, bend to shape all as directed, length of GI Pipe shall not be less than 2.0 metre for fixing of light fittings including taking out old bracket complete all as specified and as directed.
Supply and fixing in repair/replacement LED 40 W post top made in cast aluminium with decorative opal polycarbonate diffuser with IP 65 protection suitable for dia upto 60mm complete all as specified and directed.
Supply and fixing in repair LED surface mounted round downlighter 12 W with pressure die-cast sink and PC difuser in chrome finish diffuser with integrated driver complete all as specified and directed.
Disconnecting the main power supply to distribution box and make a proper dressing of SPN/TPN/VTPN MCB/MCCB DBs of pre-connected MCBs by changing screw of DB cover ,earth wire and other necessary connecting items and dressing of wires with the help of cable tie inside the distribution box after completion supply power complete all as specified and directed.
M/s Dhani Enterprise
Ms N D Enterpise
Roy and Sons Infrastructers
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .