Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹9.8 LAccepted-AOC | L1 | Accepted-AOC L1 Bidder | |
| 2 | L2₹10.0 L+₹20,438 (2.10%)Rejected-Finance | L2 | Rejected-Finance HIGHER THEN L1 BIDDER | |
| 3 | L3₹10.4 L+₹68,509 (7.02%)Rejected-Finance | L3 | Rejected-Finance HIGHER THEN L1 BIDDER | |
| 4 | L4₹10.6 L+₹80,230 (8.22%)Rejected-Finance | L4 | Rejected-Finance HIGHER THEN L1 BIDDER | |
| 5 | Rejected-Technical | - | Rejected-Technical The firm has not compiled with the eligible category b (i) |
| Sl No | Description | Qty | Unit | Darjeeling Enterprises L4 | TSHERING WANGYAL BHUTIA L3 | BIMAL BHATTRAI L2 | HIRA SINGH L1 |
|---|---|---|---|---|---|---|---|
| 1.00 | Taking down defective Geyser of any capacity ltrs from its existing position with all allied T&P/ladder etc. duly disconnected inlet/outlet water connection transporting to repair workshop if required and for repairing and re-fixing after successful repairing complete as and when requird complete all as specified and directed. | 156 | Each | 298 ₹46,488 | 323 ₹50,388 | 295 ₹46,020 | 280 ₹43,680 Lowest |
| 2.00 | Repair/maintenance of geyser of 25/50 Ltrs capacity of any make carefully by dismantling and inspecting all the parts, for its serviceability, cleaning/reconnection of serviceable parts i.e. Heating element, base assy, connecting lead, thermostat, electrical contact, electrical wiring, indicators, safety valves, vacuum control/pressure reducing valve, PVC connection, inner tank, outer tank, glass wool/puf insulation etc and refixing cover after replacement of unserviceable parts matching with existing make and sizes as mentioned above complete all as directed. [Notes (i) The defective parts to be replaced shall be measured and paid separately under relevant item of BOQ.] | 156 | Each | 500 ₹78,000 | 518 ₹80,808 | 435 ₹67,860 | 432 ₹67,392 Lowest |
| 3.00 | S&F steel wire mesh covered flexible connection pipe 15mm bore size with nuts, rubber washers etc complete of length 450 mm long matching with existing, complete all as specified and directed. | 48 | Each Pair | 230 ₹11,040 | 218 ₹10,464 Lowest | 285 ₹13,680 | 225 ₹10,800 |
| 4.00 | S&F steel wire mesh covered flexible connection pipe 15mm bore size with nuts, rubber washers etc complete of length 600 mm long matching with existing, complete all as specified and directed. | 48 | Each Pair | 365 ₹17,520 | 377 ₹18,096 | 345 ₹16,560 Lowest | 365 ₹17,520 |
| 5.00 | S&F geyser element 1.5 KW, ISI marked with gasket, nuts, bolts suitable for the existing triangular/round shape/make of the geyser under repair incl. matching with existing, complete all as specified and directed. | 46 | Each | 850 ₹39,100 | 792 ₹36,432 | 740 ₹34,040 Lowest | 810 ₹37,260 |
| 6.00 | S&F geyser element 2.0 KW, ISI marked with gasket, nuts, bolts suitable for the existing triangular/round shape/make of the geyser under repair. matching with existing, complete all as specified and directed. | 30 | Each | 1,200 ₹36,000 | 1,155 ₹34,650 | 910 ₹27,300 Lowest | 960 ₹28,800 |
| 7.00 | S&F thermostat (ISI marked) suitable for existing make of the geyser under repair of cap 50/25 Ltrs, complete all as specified and directed. | 70 | Each | 580 ₹40,600 | 553 ₹38,710 | 500 ₹35,000 | 460 ₹32,200 Lowest |
| 8.00 | M&L for wall fastners/ Anchor bolt of size 100 mm long 8mm dia with double washers incl grouting and make good the wall surface with cement mortar (1:4) for fixing water heater after removing the existing unserviceable nuts,bolts and washers complete all as specified and as directed. | 60 | Each | 87 ₹5,220 | 88 ₹5,280 | 60 ₹3,600 | 50 ₹3,000 Lowest |
| 9.00 | Supply and fix in reapair plug top 3 pin 16 Amps ISI marked incl taking down old unserviceable plug top complete all as specified and as directed. | 42 | Each | 162 ₹6,804 | 153 ₹6,426 | 155 ₹6,510 | 145 ₹6,090 Lowest |
| 10.00 | Supply and fix in 3 core 1.5 sqmm round copper flexible conductor incl taking down old unserviceable wire complete all as specified and as directed. | 200 | RM | 155 ₹31,000 | 149 ₹29,800 | 135 ₹27,000 | 132 ₹26,400 Lowest |
Tender Value
₹9.2 L
EMD Value
₹18,400
Closing Date
31 Oct 2025, 6:00 pmClosed
CWE
HQ 136 WORKS ENGINEERS PIN - 914136 C/O 99 APO
REPAIR / MAINT OF HEATING APPLIANCES, EXHAUST FAN REFRIGERATON AND INTERNAL ELECTRIFICATION OF MD ACCN MES AREA AT JALAPAHAR AND KATAPAHAR UNDER AGE(I) DARJEELING
2025_MES_729107_2
CWE/136-WE/35 OF 2025-26
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
DARJEELING
Class E, Category b(i)
8 documents required · 8 mandatory
₹500
Yes
AGE(I) Darjeeling
₹18,400
Yes
20 Nov 2025
16 Oct 2025
1 Nov 2025
16 Oct 2025
31 Oct 2025
24 Oct 2025
16 Oct 2025 - 20 Oct 2025
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Document
0.31 MB
BOQ
BOQ • 0.33 MB
Tender Documents
Tender Documents • 1.18 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .