Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹29.3 LAccepted-AOC | L1 | Accepted-AOC Being lowest bidder and reasonable | |
| 2 | L2₹31.2 L+₹1.1 L (3.78%)Rejected-Finance 186 B DIAMOND HARBOUR ROAD KOLKATA 700 060 | KOLKATA | WEST BENGAL | 700060 | L2 | Rejected-Finance Other than lowest | |
| 3 | L3₹31.7 L+₹1.7 L (5.52%)Rejected-Finance VILL PUILLYA PO UNSANI DISTT HOWRAH PIN 711302 | HOWRAH | WEST BENGAL | 711302 | L3 | Rejected-Finance Other than lowest | |
| 4 | L4₹33.8 L+₹3.7 L (12.3%)Rejected-Finance 8 28 BIJOYGARH P O JADAVPUR KOLKATA 700 032 | KOLKATA | WEST BENGAL | 700032 | L4 | Rejected-Finance Other than lowest | |
| 5 | L5₹34.1 L+₹4.1 L (13.5%)Rejected-Finance 72 A ABINASH CHANDRA BANERJEE LANE KOLKATA 700010 | KOLKATA | WEST BENGAL | 700010 | L5 | Rejected-Finance Other than lowest |
Tender Value
₹28 L
EMD Value
₹56,000
Closing Date
19 Sept 2022, 6:00 pmClosed
GE(FW) Kolkata
D9 Commissariat Road Hastings Kolkata 700022
REPAIR /MAINTENANCE OF CEILING / EXHAUST / PEDESTAL / WALL FANS AND ALLIED ELECTRICAL WORKS INSIDE FORT WILLIAM UNDER GE(FW) KOLKATA
2022_MES_546462_1
8887/FW/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE(FW) Kolkata
Ref tender documents
7 documents required · 7 mandatory
₹500
GE(FW) Kolkata
₹56,000
1 Nov 2022
20 Aug 2022
20 Sept 2022
20 Aug 2022
19 Sept 2022
3 Sept 2022
Amount
Taking down copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc. removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc complete all as specified and directed.
Taking down of Old MCB DB any type any size including MCCB/RCCB/MCBs and disconnecting the serviceable MCBs and keeping in safe custody for reuse at site or removal from site complete all as specified and directed.
Taking down of old Submain wiring any type including batten/ conduit/ casing at any indicated situation complete all as specified and directed.
M&L for surface type point wiring with 1.50 Sq. mm (nominal area) FRLS-H PVC insulated and unsheathed, multi stranded copper conductor cable 1100 Volts grade, single core, laid in and including PVC casing capping medium duty complete with all fittings and accessories, fixed to walls/ceiling, including mild steel terminal boxes 1.25 mm thick conforming to IS-5133 (Part-I) with 3.0 mm thick plastic laminated sheet top cover (ISI Marked) for mounting switches/ regulator /bell push etc and including 1.50 Sq. mm (nominal area) FRLS-H PVC insulated and unsheathed multi stranded copper conductor cable 1100 Volts grade, single core, earth continuity conductor connected to common earth dolly, for one light point /bell point/ceiling fan/exhaust fan point controlled by one way switch complete all as specified and directed.
All as per item No. 04 above but for one 5 amps switch socket outlet on same board controlled by another switch, complete all as specified and directed (surface type point wiring with terminal box).
All as per item No. 04 above but for one 5 amps switch socket combination on independent board, complete all as specified and directed (surface type point wiring with terminal box).
All as per item No. 04 above but using 2.5 sqmm single core multi stranded copper conductor FRLS-H PVC insulated and unsheathed, cable for 3/6 pin 15 Amp socket outlet controlled by one switch on independent board with and incl 2.5 sqmm green FRLS PVC insulated and unsheathed, copper conductor as continuous earth wire with lugs complete all as specified and directed (surface type point wiring with terminal box).
M&L for concealed type point wiring with 1.50 Sq. mm (nominal area) FRLS-H PVC insulated and unsheathed, multi stranded copper conductor cable 1100 Volts grade, single core, laid in and including PVC conduit complete with all fittings and accessories, fixed to walls/ceiling, including mild steel terminal boxes 1.25 mm thick conforming to IS-5133 (Part-I) with 3.0 mm thick plastic laminated sheet top cover (ISI Marked) for mounting switches/ regulator /bell push etc and including 1.50 Sq. mm (nominal area) FRLS-H PVC insulated and unsheathed multi stranded copper conductor cable 1100 Volts grade, single core, earth continuity conductor connected to common earth dolly, for one light point /bell point/ ceiling fan/exhaust fan point controlled by one way switch complete all as specified and directed. (NOTES: - (i) Where tube light fitting is to be fitted/suspended, CI Circular boxes shall be provided with the PVC Pipes in the ceiling & the unit rate shall be deemed to be included for the same. (ii) Cost of cutting chases for concealed wiring shall be deemed to be inclusive in the quoted rates. No claim in this regard shall be entertained at a later stage)
All as per item No. 08 above but for one 5 amps switch socket outlet on same board controlled by another switch, complete all as specified and directed (concealed type point wiring with terminal box).
All as per item No. 08 above but for one 5 amps switch socket combination on independent board, complete all as specified and directed (concealed type point wiring with terminal box).
All as per item No. 08 above but using 2.5 sqmm single core multi stranded copper conductor FRLS-H PVC insulated and unsheathed, cable for 3/6 pin 15 Amp socket outlet controlled by one switch on independent board with and incl 2.5 sqmm green FRLS-H PVC insulated and unsheathed, copper conductor as continuous earth wire with lugs complete all as specified and directed (concealed type point wiring with terminal box).
M&L for concealed type point wiring with 1.50 Sq. mm (nominal area) FRLS-H PVC insulated and unsheathed, multi stranded copper conductor cable 1100 Volts grade, single core, laid in and incl PVC conduit complete with all fittings and accessories (except terminal box and laminate cover), fixed to walls/ceiling, for mounting MODULAR TYPE switches/ regulator /bell push etc and including 1.50 Sq. mm (nominal area) FRLS-H PVC insulated and unsheathed multi stranded copper conductor cable 1100 Volts grade, single core, earth continuity conductor connected to common earth dolly for One light point or one fan point or bell point controlled by one switch or bell push complete all as specified and directed. (NOTE :- (i) Where tube light fitting is to be fitted/ suspended, CI Circular boxes shall be provided with the PVC Pipes in the ceiling & the unit rate shall be deemed to be included for the same. (ii) Quoted rate shall be exclusive of the cost of terminal box & laminate cover which shall be measured seperately. (iii) Cost of cutting chases for concealed wiring shall be deemed to be inclusive in the quoted rates. No claim in this regard shall be entertained at a later stage)
All as per item No 12 here-in-before but for one 5 pin 5/6 amp socket out let point in the same switch board of light points (except terminal box and laminate cover), fixed to walls/ceiling, for mounting MODULAR TYPE switches
All as per item No 12 here-in-before but for one 5 pin 5/6 amps multisocket outlet point in independent board (concealed wiring) (except terminal box and laminate cover), fixed to walls/ceiling, for mounting MODULAR TYPE switches
All as per item No 12 above but using 2.50 Sq. mm (nominal area) FRLS-H PVC insulated and unsheathed, multi stranded copper conductor cable 1100 Volts grade, single core for line conductor and 2.50 Sq. mm (nominal area) FRLS-H PVC insulated and unsheathed multi stranded copper conductor cable 1100 Volts grade, single core for earth continuty wire for one 15/16 amp multi socket out let independent. (concealed wiring) (except terminal box and laminate cover), fixed to walls/ceiling, for mounting MODULAR TYPE switches
Materials and Labour for concealed type point wiring with 1.50 Sq. mm (nominal area) FRLS-H PVC insulated and unsheathed, multi stranded copper conductor cable 1100 Volts grade, single core, laid in existing PVC conduit complete with all fittings and accessories, fixed to walls/ceiling, including mild steel terminal boxes 1.25 mm thick conforming to IS-5133 (Part-I) with 3.0 mm thick plastic laminated sheet top cover (ISI Marked) for mounting switches/ regulator /bell push etc and including 1.50 Sq. mm (nominal area) FRLS-H PVC insulated and unsheathed multi stranded copper conductor cable 1100 Volts grade, single core, earth continuity conductor connected to common earth dolly, for one light point /bell point/ ceiling fan/exhaust fan point controlled by one way switch complete all as specified and directed. (NOTE: Wiring shall be done in existing conduit. Quoted rate shall be excusive of the cost of conduit)
All as per item No. 16 above but for one 5 amps switch socket combination on independent board, complete all as specified and directed (concealed type point wiring with terminal box in existing conduit).
All as per item No. 16 above but using 2.5 sqmm single core multi stranded copper conductor FRLS-H PVC insulated and unsheathed, cable for 3/6 pin 15 Amp socket outlet controlled by one switch on independent board with and incl 2.5 sqmm green FRLS-H PVC insulated and unsheathed, copper conductor as continuous earth wire with lugs complete all as specified and directed (concealed type point wiring with terminal box in existing conduit).
S&F switch piano flush button AC 230 V Single pole 5/6 Amp one way complete all as specified and directed.
S&F Bell push, flush type, 5/6 Amps, 240 volts complete all as specified and directed.
S&F socket outlet, non-shuttered, 2-in-1, 3 pin, 6 Amp AC 230 Volts flush type complete all as specified and directed.
S&F switch socket combination, 5 pin, 6 Amp AC 230 Volts flush type complete all as specified and directed.
S&F switch socket combination 2 in 1, 3 pin, 6 and 16 Amps flush type universal complete with all necessary electrical connection all as specified and directed.
S&F switch piano flush button AC 230 V Single pole 15/16 Amp one way complete all as specified and directed.
S&F socket outlet, non-shuttered, 2-in-1, 3 pin, 15 Amp AC 230 Volts flush type complete all as specified and directed.
S&F new Call bell, musical type, AC 230/240 Volts, single pole complete all as specified and directed.
S&F new Call bell, ding dong type, AC 230/240 Volts, single pole complete all as specified and directed.
S&F ceiling rose surface, polycarbonate/bakelite, three terminals complete all as specified and directed.
S&F stepped type electronic fan regulator, flush type, 100 watts, 5 Speed Control, 230/240 Volts complete all as specified and directed.
S&F lamp holder, PVC/Polycarbonate body with back plate suitable for batten/pendant fittings or to be mounted on walls complete all as specified and directed.
S & F Modular Switch 1 way, 6 Amps, 1 module complete all as specified and directed.
S & F Modular Switch 1 way, 16 Amps, 1 module complete all as specified and directed.
S & F Modular Socket 6 Amps, 2/3 pin combined, 2 module complete all as specified and directed.
S & F Modular Socket 6/16 Amps, 2/3 pin combined, 2 module complete all as specified and directed.
S & F Modular Fan step regulator, 120 watt, 2 module complete all as specified and directed.
S & F Modular Bell push 6 Amps, 1 module complete all as specified and directed.
S & F Modular Blank plate, 1 module complete all as specified and directed.
S & F 25 Amps motor starter switch, modular type complete all as specified and directed.
S&F Modular White cover plate with frame 1 module complete all as specified and directed.
S&F Modular White cover plate with frame 2 module complete all as specified and directed.
S&F Modular White cover plate with frame 3 module complete all as specified and directed.
S&F Modular White cover plate with frame 4 module complete all as specified and directed.
S&F Modular White cover plate with frame 6 module complete all as specified and directed.
S&F Modular White cover plate with frame 8 module complete all as specified and directed.
S&F Modular White cover plate with frame 12 module complete all as specified and directed.
S & F Modular type Metal Flush box 1/2 module complete all as specified and directed.
S & F Modular type Metal Flush box 3 module complete all as specified and directed.
S & F Modular type Metal Flush box 4 module complete all as specified and directed.
S & F Modular type Metal Flush box 6 module complete all as specified and directed.
S & F Modular type Metal Flush box 8 module complete all as specified and directed.
S & F Modular type Metal Flush box 12 module complete all as specified and directed.
S & F in repair Modular fittings/accessories in existing location complete all as specified & directed for the following types :-. (Note: Make of fitting shall be as per existing one)
Modular Switch 1 way 6 A, 1 module, 240 Volts AC
Modular Switch 1 way 16 A, 1 module, 240 Volts AC
Modular Socket 6 A, 2/3 pin combined 2 module, shuttered, 240 Volts AC
Modular Socket 16 A, 2/3 pin combined 2 module, shuttered, 240 Volts AC
Modular Fan step regulator, 120 watt, 2 module, 100W, 4 step, 240 Volts AC
M&L for sub main wiring with 4 run of FRLS-H PVC insulated & unsheathed multistranded copper conductor of nominal cross sectional area 10.0 sqmm alongwith one run of FRLS-H PVC insulated & unsheathed multistranded copper conductor of nominal cross sectional area 10.0 sqmm as earth continuity conductor drawn through and including PVC casing-caping of suitable size, surface type complete all as specified and directed. (NOTE : Five runs of single core 10.0 sqmm cable & one run of PVC casing capping shall be measured as one unit)
All as per Srl. Item No. 53 above but with two runs of 6.0 Sqmm cable and one run of 6.0 Sqmm as earth continuity conductor in PVC casing capping (NOTE : Three runs of single core 6.0 sqmm cable & one run of PVC casing capping shall be measured as one unit)
All as per Srl. Item No. 53 above but with two runs of 4.0 Sqmm cable and one run of 4.0 Sqmm as earth continuity conductor in PVC casing capping (NOTE : Three runs of single core 4.0 sqmm cable & one run of PVC casing capping shall be measured as one unit)
S&F TPN DB, IP 43 protection, double door (premium range), 415 volts, 4 way (8+12), with 100 Amps copper bus bar for each phase complete all as specified and directed.
All as per Item No. 56 above 4 Way (8+12) TPN DB (normal range) complete all as specified and directed.
S&F SPN DB, IP 43 protection, double door (Premium range), 240 volts, 4 way, with 100 Amps copper Bus Bar complete all as specified and directed.
All as per Item No. 58 above 4 Way SPN DB (normal range) complete all as specified and directed.
S&F Double Door, Sheet Metal Enclosure for DBs (Premium range), for mounting of MCB for 240 Volts, 8 way, with 100 Amps rated copper bus bar, Single Pole & Neutral, complete all as specified and directed.
All as per Item No. 60 above 8 Way SPN DB (normal range) complete all as specified and directed.
S&F MCB (premium range), 'C' series, TPN, 415 volts, 63 Amps, breaking capacity 10KA complete all as specified and directed.
S&F MCB (normal range), 'C' series, TPN, 415 volts, 63 Amps, breaking capacity 10KA complete all as specified and directed.
S&F MCB (premium range), 'C' series, SPN, 32 Amps, breaking capacity 10KA complete all as specified and directed.
S&F MCB (normal range), 'C' series, SPN, 32 Amps, breaking capacity 10KA complete all as specified and directed.
S&F MCB (Premium Range), 'C' series, single pole, 6 to 32 Amps, breaking capacity 10KA complete all as specified and directed.
S&F MCB (normal range), 'C' series, single pole, 6 to 32 Amps, breaking capacity 10KA complete all as specified and directed.
S&F in repairs PVC casing/caping of size 25 mm with all accessories all as directed by Engr-in- charge .
S&F in repairs PVC casing/caping of size 20 mm with all accessories all as directed by Engr-in- charge .
S&F in repairs GI tubing medium grade of size 15 mm dia incl painting and making hole for extension of fan hook in high roof ceiling complete all as specified and directed.
S&F in repair clamp with buckle for hanging ceiling fan including nuts and bolts and other accessories, suitable for any type of ceiling fan complete all as specified and directed.
Supply only LED driver for 2'x2' LED ceiling light fitting 230 Volt 30 watt - 40 watt complete all as specified and as directed.
Supply only LED driver for LED ceiling light fitting 230 Volt 18 watt - 28 watt complete all as specified and as directed.
Supply only LED driver for LED ceiling light fitting 230 Volt 05 watt - 15 watt complete all as specified and as directed.
Supply only LED driver for LED strip light, 230 Volt 5 W complete all as specified and as directed.
S&F in repair PVC cable tray of size 100 X 100 mm, 16 gauge thickness with all accessories such as clamps, screws etc complete all as specified and directed.
S&F in repair MODULAR MCB protected power unit with one 25 Amps socket with 3 pin plug top and including 01 No MCB, DP, and starter 25 Amps ratings with six module plate and flush metal GI box and electrically connected complete all as specified and directed. (MAKE : HAVELLS, Cat No. DHDUCDP0253025 / NORTH WEST, Cat No: ACPU6M-BT or equivalent model in ABB / CRABTREE / HAGER / SCHNEIDER / LEGRAND) (NOTE : Enclosure & MCB shall be same manufacturer. Cost of MCB is deemed to be included in the quoted rate)
S&F in repairs single pole enclosure with two pin and earth plug and socket complete with one SP MCB, 20 Amps, 'C' Curve, 10 KA including all accesories complete all as specified and directed. (MAKE OF ENCLOSURE: LEGRAND, Cat No. 5078 10 / L&T, Cat No. DBMPS120SD / SCHNEIDER, Cat No: A9HMS220 / ABB, Cat No. NSYN8690SGKSP20 / C&S, Cat No: CSDBPSSPN020 /HAGER, Cat No: VYA220C) (NOTE : Enclosure & MCB shall be same manufacturer. Cost of MCB is deemed to be included in the quoted rate)
Repair/maintanance of ceiling fan, in existing position, of any sweep and at any height by replacing unserviceable spares e.g.capacitors/clamps/rubber reel/tightening the loose connections if any including testing complete all as directed. (Note: Spares shall be will be measured & paid under relavent item here-in-after)
Taking down unserviceable ceiling fan 1200mm sweep of any make, opening the fan, complete overhauling incl oiling, greasing, rewinding with super enameled copper winding wire as per existing size and gauge including heating, varnishing, re-assembling and hanging the ceiling fan, connecting up including provision of three core copper wire of suitable size from ceiling rose or connector to fan, complete all as specified and as directed by Engr In Charge.
Taking down unserviceable ceiling fan 1400mm sweep of any make, opening the fan, complete overhauling incl oiling, greasing, rewinding with super enameled copper winding wire as per existing size and gauge including heating, varnishing, re-assembling and hanging the ceiling fan, connecting up including provision of three core copper wire of suitable size from ceiling rose or connector to fan, complete all as specified and as directed by Engr In Charge.
Taking down unserviceable exhaust fan 200 to 300 mm sweep of any make, opening the fan, complete overhauling incl oiling, greasing, rewinding with super enameled copper winding wire as per existing size and gauge including heating, varnishing, and testing, re-assembling and refixing the same in original position including provision of copper wire of suitable size from ceiling rose or connector to fan, complete all as specified and as directed by Engr In Charge.
Taking down unserviceable exhaust fan 380 mm sweep of any make, opening the fan, complete overhauling incl oiling, greasing, rewinding with super enameled copper winding wire as per existing size and gauge including heating, varnishing, and testing, reassembling and refixing the same in original position including provision of copper wire of suitable size from ceiling rose or connector to fan, complete all as specified and as directed by Engr In Charge.
Taking down unserviceable exhaust fan 450 mm sweep of any make, opening the fan, complete overhauling incl oiling, greasing, rewinding with super enameled copper winding wire as per existing size and gauge including heating, varnishing, and testing, re-assembling and refixing the same in original position including provision of copper wire of suitable size from ceiling rose or connector to fan, complete all as specified and as directed by Engr In Charge.
Taking down unserviceable exhaust fan 600 mm sweep of any make, opening the fan, complete overhauling incl oiling, greasing, rewinding with super enameled copper winding wire as per existing size and gauge including heating, varnishing, and testing, re-assembling and refixing the same in original position including provision of copper wire of suitable size from ceiling rose or connector to fan, complete all as specified and as directed by Engr In Charge.
Taking down unserviceable wall fan 250-400 mm sweep of any make, opening the fan, complete overhauling incl oiling, greasing, rewinding with super enameled copper winding wire as per existing size and gauge including heating, varnishing, and testing, re-assembling and refixing the same in original position including provision of copper wire of suitable size from ceiling rose or connector to fan, complete all as specified and as directed by Engr In Charge.
Taking down unserviceable wall fan 450-600 mm sweep of any make, opening the fan, complete overhauling incl oiling, greasing, rewinding with super enameled copper winding wire as per existing size and gauge including heating, varnishing, and testing, re-assembling and refixing the same in original position including provision of copper wire of suitable size from ceiling rose or connector to fan, complete all as specified and as directed by Engr In Charge.
Taking down unserviceable pedestal fan, any sweep or make, opening the fan, complete overhauling incl oiling, greasing, rewinding with super enameled copper winding wire as per existing size and gauge including heating, varnishing, and testing, re-assembling and refixing the same in original position including provision of copper wire of suitable size from ceiling rose or connector to fan, complete all as specified and as directed by Engr In Charge.
Taking down unserviceable wall mounted air circulators, any sweep or make, opening the fan, complete overhauling incl oiling, greasing, rewinding with super enameled copper winding wire as per existing size and gauge including heating, varnishing, and testing, re-assembling and refixing the same in original position including provision of copper wire of suitable size from ceiling rose or connector to fan, complete all as specified and as directed by Engr In Charge.
M&L for painting to ceiling fans 1200 mm sweep of any make with one coat of synthetic enamel paint by spraying after cleaning thoroughly with kerosene oil including filling cavities with filler etc incl writing MES No. complete all as specified and as directed by Engr In Charge.
M&L for painting to ceiling fans 1400 mm sweep of any make with one coat of synthetic enamel paint by spraying after cleaning thoroughly with kerosene oil including filling cavities with filler etc incl writing MES No. complete all as specified and as directed by Engr In Charge.
M&L for painting to wall fans 250 to 400 mm sweep of any make with one coat of synthetic enamel paint by spraying after cleaning thoroughly with kerosene oil including filling cavities with filler etc incl writing MES No. complete all as specified and as directed by Engr In Charge.
M&L for painting to wall fans 450 to 600 mm sweep of any make with one coat of synthetic enamel paint by spraying after cleaning thoroughly with kerosene oil including filling cavities with filler etc incl writing MES No. complete all as specified and as directed by Engr In Charge.
M&L for painting to exhaust fans 200 to 380 mm sweep of any make with one coat of synthetic enamel paint by spraying after cleaning thoroughly with kerosene oil including filling cavities with filler etc incl writing MES No. complete all as specified and as directed by Engr In Charge.
M&L for painting to exhaust fans 450 to 600 mm sweep of any make with one coat of synthetic enamel paint by spraying after cleaning thoroughly with kerosene oil including filling cavities with filler etc incl writing MES No. complete all as specified and as directed by Engr In Charge.
M&L for painting to pedestal fans, any sweep of any make with one coat of synthetic enamel paint by spraying after cleaning thoroughly with kerosene oil including filling cavities with filler etc incl writing MES No. complete all as specified and as directed by Engr In Charge.
M&L for painting to air circulators, any sweep of any make with one coat of synthetic enamel paint by spraying after cleaning thoroughly with kerosene oil including filling cavities with filler etc incl writing MES No.complete all as specified and as directed by Engr In Charge.
S&F in repair Capacitor 2.5 mfd, 230 Volts, AC, 50 Hz, complete all as specified and as directed.
S&F in repair Capacitor 3.15/3.5 mfd 230 Volts, AC, 50 Hz, complete all as specified and as directed.
S&F in repair Gun Metal Bush suitable for wall Fan /Exhaust Fan complete all as specified and as directed.
S&F in repair Ball Bearing of suitable size for Ceiling / Exhaust Fans of any size complete all as specified and as directed.
S&F in repair MS down rod of size 15/20 mm dia and length 1' for ceiling fan including electric connection, nut, bolt and clamp complete all as specfied and directed.
S&F in repair MS down rod of size 15/20 mm dia and length 2' for ceiling fan including electric connection, nut, bolt and clamp complete all as specfied and directed.
S&F in repair MS down rod of size 15/20 mm dia and length 3' for ceiling fan including electric connection, nut, bolt and clamp complete all as specfied and directed.
S&F of rubber reel 1.7/2.5 insulator for Ceiling fan suitable for 1200/1400mm sweep complete all as specified and directed.
S&F of split pin of suitable size for ceiling fan of sweep 1200mm/1400mm.
S&F of PVC connector for Ceiling fan of 1200/1400mm sweep including all connection complete all as specified and directed.
MS JYOTI INDUSTRIES
PRABIR TRADERS
DEB AND COMPANY
MS HORIZEN
SK CONSTRUCTION SYNDICATE & ENGG CO
UNIVERSAL TRADING CENTRE
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .