Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Tender Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹26.6 LAccepted-AOC 18TH FLOOR FL NO 1801 PANCHASHEEL HEIGHT MAHAVEER NAGAR KANDIVALI WEST MUMBAI 400067 | MUMBAI | MUMBAI SUBURBAN | MAHARASHTRA | 400067 | L1 | Accepted-AOC BEING L1 | |
| 2 | L2₹29.9 L+₹3.0 L (11.3%)Rejected-Finance B 12 VISHAKARMA JYOTI SUBHASH LANE MALAD E MUMBAI 400097 | MUMBAI SUBURBAN | MAHARASHTRA | 400097 | L2 | Rejected-Finance BEING L2 | |
| 3 | L3₹30.8 L+₹3.9 L (14.5%)Rejected-Finance 64 A JASRAJ MANSION 1ST FLOOR OLD HANUMAN LANE KALBADEVI ROAD MUMBAI 400 002 | MUMBAI | MAHARASHTRA | 400002 | L3 | Rejected-Finance BEING L3 |
Tender Value
₹39.5 L
EMD Value
₹79,000
Closing Date
19 Mar 2024, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE AF THANE
Office of Military Engineer Services ,Garrison Engineer (AF) Thane, Kolshet Road, Sandoz Baugh Post, Thane 400607
UPGRADATION OF CERTAIN SMQ AT AFS MADH ISLAND UNDER GE AF THANE
2024_MES_643588_1
8352/E8
Open Tender
Civil Works
Item Rate
180 days
THANE
AS PER NIT
8 documents required · 8 mandatory
₹500
GE AF THANE
₹79,000
Yes
30 Aug 2024
22 Feb 2024
21 Mar 2024
22 Feb 2024
19 Mar 2024
7 Mar 2024
22 Feb 2024 - 7 Mar 2024
Amount
Removal of existing concrete including loose/weak concrete from the concrete structure i.e. beams/columns/deckslab etc upto beyond corroded steel reinforcements to a depth of minimum 10mm minimum behind the reinforcement by chipping/hacking with chisel and hammer or by mechanical means like chisel hammer, pneumatic chippers including high pressure water jetting and removal of debris. Concrete around the corroded reinforcement shall be removed properly. The edges of the repair locations of concrete should be saw cut to depth of at least 10mm to avoid featheredging and to provide a square edge complete all as specified and directed by Engr-in- Charge. Note :- The contractor Quoted rate should includes necessary scaffolding and form work both for new work as well as for protection of existing structure during rehabilitation.
M&L forPreparation of surface and removal of rust in the loosely bonded concrete of the RCC deckslab, beam / girder and piles shall be chipped out using the mechanical cutter exposing the bars and applying Rust Remover using small brush and allow to react it for 16- 24 hrs. Before applying protective coating,the surface should be wire brushed and thoroughly cleaned for dust with dry cloth complete all as per manufacturer instructions and directed by Engr- in- Charge. Note :- The contractor Quoted rate should includes necessary scaffolding and form work both for new work as well as for protection of existing structure during rehabilitation.
M&L for applying two coats of Anti-Corrosive Primer two component (epoxy anticorrosive zinc rich coating) on reinforcement steel surfaces uniformely. Coating shall be applied by the brush to the exposed and cleaned rebars with an interval of 45 minutes to 1 hour @ 40microns DFT / coat and allowed to completely dry for 24 hours complete all as per manufacturer instructions and directed by Engr- in- Charge. Note :- The contractor Quoted rate should includes necessary scaffolding and form work both for new work as well as for protection of existing structure during rehabilitation.
M&L preparation of concrete surfaces by removing loose concrete, dust, dirt etc, cleaning the surface properly and applying one liberal coat of epoxy bonding agent ( two component agent) by brush application complete all as per manufacturer instruction and directed by Engr-in- Charge Note :- The contractor Quoted rate should includes necessary scaffolding and form work both for new work as well as for protection of existing structure during rehabilitation.
M&L for Providing & executing injection/pressure grouting in the cracks in the parent concrete by fixing PVC/Aluminium nipples at 150mm to 200mm distance or specified distances as per design and detailed specifications. Pressure grouting using low viscous epoxy grout. Moisture insensitive epoxy resin injection material supplied in 1.5 Litre pack which can grout gaps ranging from 0.25mm to 9mm, having mix density 1060 Kg/m3, compressive strength 60 N/mm2, Tensile Strength 20 N/mm2, Flutural strength 45 N/mm2. Pressure grouting shall be carried out after surface preperations includes fixing nipples and filling cracks with epoxy mortar one day before grouting, injecting low viscous grout mechanically about pressure 3.5-7.0 Kg/Cm2, removing nipple after grouting and sealing with epoxy mortar etc complete as directed by Engr - in - Charge. Payment shall be made on actual grout consumed. Note :- The contractor Quoted rate should includes necessary scaffolding and form work both for new work as well as for protection of existing structure during rehabilitation.
M&L for Cutting, fabricating new reinforcement Fe500 and fixing with old existing reinforcement which was reduced to 20% or more of its original diameter as provided in original structure and additional steels as directed by EIC to be fixed with chemical anchor grout Lokfix E55 (Styrene free vinyl-ester resin based catridge system for anchoring reinforcement supplied in 300 ml catridge with a single mixer nozzle of Fosroc or equivalent approved make, application includes drilling hole close to old reinforcement bar with suitable drill as per dia of bar, cleaning the hole with wire brush and compressed air, putting Lokfix E55 or equivalent with gun followed by placing rebar with slide rotational motion to avoid air void formation etc complete all as per manufacturer instructions and as directed by the Engr-in- Charge. Note :- The contractor Quoted rate should includes necessary scaffolding and form work both for new work as well as for protection of existing structure during rehabilitation.
M&L for Drilling holes into existing concrete substrate for anchoring of new rebars nwith 10mm dia shear connectors at 0.5 mtr c/c and fixed with chemical anchor Lokfix E55 or equivalent - Styrene free vinyl-ester resin based catridge system for anchoring reinforcement supplied in 300 ml catridge with a single mixer nozzle, shall be tested in accordance European approval to EAD-33087-00-0601 for use in post-installed rebar, which supersedes ETAG 001 TR 023 (rebar), LEED compliant VOC Level, Fire resistance<120mins, Seismic C1 testing as part of EAD 330499-00-0601 for specific fastening sizes etc. Typical applications includes drilling hole 14mm dia and 90mm deep as per manufacturers recommendation, cleaning the hole with wire brush and compressed air, putting Lokfix E55 with gun followed by placing shear connector with slide rotational motion to avoid air void formation etc complete as directed by EIC. HSE Guidelines : Recommended to wear tight fitting, dust-resistant, chemical splash goggles if airborne dust is generated, Wear protective gloves. Wear appropriate clothing to prevent any possibility of skin contact. Note :- The contractor Quoted rate should includes necessary scaffolding and form work both for new work as well as for protection of existing structure during rehabilitation.
M&L for 50mm thick ( average thickness) modified single component, alkaline resistant fibre reinforced, thixotropic, cementitious patch repair mortar on conrete structure. Applying the mortar arround the reinforcement and finishing to bring it in line with existing concrete surface complete all as per manufacturer instructions and directed by the Engr-in- Charge. Note :- The contractor Quoted rate should includes necessary scaffolding and form work both for new work as well as for protection of existing structure during rehabilitation.
M&L for micro concrete to existing concrete structure including proper tight leak proof shuttering SPL polimer modified cementitious ,low permeable'free flow 'non shrink 'self compacting micro concrete shall be grade M70 as per recommended w/c ratio and pouring as per the required thickness complete all as per manufacturer instructions and directed by Engr- in- Charge. Note :- The contractor Quoted rate should includes necessary scaffolding and form work both for new work as well as for protection of existing structure during rehabilitation.
Taking down cement plaster on brick/stone or concrete surface including racking out joints, hacking for key, scrubbing down with water to receive plaster, including removing debris/rubbish materials off the site complete all as specified and directed by Engineer-in-Charge.
M&L for rendering 15mm thick in cm 1:6 finished with neeru finish as specified on fair faces of brick work /stone or concrete surfaces complete all as specified and directed by Engineer-in-Charge.
M & L for rendering 20 mm thick in cement mortar 1:4 (15 mm thick backing coat in CM 1:6 and 5mm thick finishing coat in CM 1:4 ) on fair faces of brick work or concrete surfaces including finished even and smooth without using extra cement with using water proofing compound (water proofing compound shall be measured and paid seperately) complete all as specified and directed by Engineer-in-Charge.
Supply only liquid water proofing compound complete all as specified and directed by Engineer-in-Charge.
Material & Labour for new and old surface of wall applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces all as specified and directed by Engineer-in-Charge.
M&L for preparing newly plastered surfaces ,and applying 2 coats of Oil Bound Distemper over a coat of alkali resistent primer Over 1 mm thick wall care putty on wallscomplete all as specified and directed by Engineer-in-Charge.
M&L for rendering 5 mm thick in cm 1:3 on fair faces of concrete as in soffit/ ceilling or slab, chajjas finished even and smooth without using extra cement complete all as specified and directed by Engineer-in-Charge.
M&L Complete removal of existing treatment on old surface of walls and applying 2 coats of Oil Bound Distemper over a coat of alkali resistent primer complete all as specified and directed by Engineer-in-Charge.
M&L for Preparation of newly surfaces of ceiling and applying three coat of white wash complete all as specified and directed by Engineer-in-Charge.
M&L for special treatment for sunken portion ow WC's bath toilet, kitchen etc executed in following stages:- Stage 1. Proviidng 15mm thick plaster in CM 1:3 mixed with wtaer proofing chemical for Dr.fixit or shalicrete 'R' of STP ltd in the proportion/quantity all as per manufactures' instructuions. Stage2 : Primer-Mix Tarfelt LM of STP letd ( diluted with water in ration 1:1)@ 250 gms/sqm and apply the primer on the plasdtered surfaces. Stage3: Application of 1st coat of tarfeit LM of STP Ltd ( without dilution with water ) !1kg /sqm by brush all as per manufactures instrcutions. Stage 4: Laying fyber galss cloth weight not less tat 50 grms /Sqm) Over the 1st Coat while the coated surfaces is still sticly. Stage 5 : After 6 to 7 housrs interal, apply second coat i.e final coat of trafet LM os STP Ltd (without Dilution with water) @ 1kg Sqm by brush as per manufactures instruicons . Stage 6 . Providing 10mm thick protective plaster in CM 1:3 Mixed with STP No1 @250 Ml/50kg cement aill as per manufacturers instrcuions Stage 7: Carry out ponding test for 48 hours to ensuser water tightness of repaired sunken proiton. NOTES : (I) Mode of measurement : Actual area treatred ( Floor and adjoingi walls) will be measeured and paid. (ii) The above treament shall be got exectued throught authoriesed applicator of manfacturer and necessary authenticated documents on accound of above shall also be produced by the contractor:-
Taking down Chowkhats or frames with shutters (without taking off shutters from the frames) not exc. 1.5 sq. m each and removing from site all as specified and as directed.
Taking down chowkats or frames exc 1.5 sqm & n exc 4 sqm with shutters without taking off shutters from the frame and removing to store
Taking down shutters of any description exc 1.00 sqm but n exc 2 sqm
S&F solid PVC double door frame of size 50mmx95mm made out of 5mm single side prelam PVC sheet reinforced with MS tube, supplying & fixing in opening as per specification and drawing
S&F factory made single exstruded WPC (Wood polymer composite) solid door/ window ceosetory window & other frames/ chowkhat of size 50 x 100 mm comprising of virgin PVC polymer of K Value 58-60 (suspension Grade) calcium carbonate and natural fibers (wood powder/ rice husk/ wheat husk ) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/ cum, screw withdrawal strength of 2200 N (Face) & 1100N (Edge), minimum compressive strength of 58N/ mm2 , modules of elasticyty 900N / mm2 and resistance to spread of flame of class A category with property of being termite/ borer proof, water/ moisture proof and fire retardant and fixed in position with MS hold fast/ lugs/ SS dash fasteners of required dia and length complete as per direction of Engineer -in - charge. (M.S. hold fast/ lugs or SS dash fasteners shall be paid for separately). Note :- For WPC Solid door/ window frames, minus 5 mm tolerance in dimension i.e. depth and width of profile shall be acceptable. Variation in profile but no extra payment on this account shall be made.
S&F factory made single extruded WPC (Wood polymer composite ) solid plain flush door shutter of 30 mm size comprising of virgin polymer of K value 58-60 ((suspension Grade) calcium carbonate and natural fibers (wood powder/ rice husk/ wheat husk ) and non toxic additives (maximum toxicity index of 12 for 100 gms) f having minimum frame density of 650 kg/ cum, screw withdrawal strength of1800 N (Face) & 900N (Edge), minimum compressive strength of 50N/ mm2 , modules of elasticyty 850N / mm2 and resistance to spread of flame of class A category with property of being termite/ borer proof, water/ moisture proof and fire retardant and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk SS screws, all as per direction of Engineer -in - charge. Note Stainless steel butt hinges and necessary S S Screws shall be paid separately)
S&F Factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails. M.S. frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; Panelling of plain colour PVC sheet to be fitted in the M.S. frame welded / sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solventcement, suppling & fixing in the frame at site as per specification & drawing ,complete all as specified and as directed by Engr-in-charge.
S&F PVC factory made wire gauged shutter with wire gauge warpped on an additional square 8mm MS solid tube and this tube shall be welded to MS tube. The wires gauge shall be stretched to tighten firmly, PVC door shutter 30mm thick (stiles) consisiting of frame made out of MS tube for top & bottom rails. MS frame shall be covered with heat moulded plain colour PVC 'C' channel having a PVC sheet strip of 20mm wigth stuck inside with solvent cement for stiles and plain colour PVC sheet for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail all as per specification and drawing given in SSR Part II, Schdule of rates 2010 and directed but as in four panels in lieu of two panels ,complete all as specified and as directed by Engr-in-charge.. Note : The wire mesh shall be measured separately.
S&F 125mm size Butt hinges, extruded aluminium alloy with galvanised mild steel hinge pin, anodised and fixed, type B-21 ,complete all as specified and as directed by Engr-in-charge.
S&F 100mm size Butt hinges, extruded aluminium alloy with galvanised mild steel hinge pin, anodised and fixed, type B-21 ,complete all as specified and as directed by Engr-in-charge.
S&F 100 mm long aluminium extruded alloy handles fabricated type anodized ,complete all as specified and as directed by Engr-in-charge.
S&F 150mm long extruded aluminium alloy handles fabricated type anodized ,complete all as specified and as directed by Engr-in-charge.
S&F 150mm long aluminium anodized barrel tower bolts of extruded section ,complete all as specified and as directed by Engr-in-charge.
M&L for cutting holes in bricks walls built in cement mortar for inserting holdfasts and making good dismantled portion in cement mortar or cement concrete 1:2:4 type B1 as required exc half brick but not exc one brick ,complete all as specified and as directed by Engr-in-charge.
S&F in repair 12mm thick prelaminated particle board interior grade, prelaminated one side with decorative choice lamination and other side balancing white lamination, fixed with screws to timber frame work ,complete all as specified and as directed by Engr-in-charge.
Supply only Stainless steel wire cloth 0.56mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples complete all as directed by Engr-in-Charge
S&F Hasp and staple aluminium anodised wire type stove enamelled black, including bolt to hinge plate and fixed with screws ,complete all as specified and as directed by Engr-in-charge.
Taking down aluminium sliding windows of any description and any size and replacing the wornout, broken wiremesh, aluminium sections, glass grill, rubber beading, rollers, locks etc as required and refixing back into the same opening for easy movement of shutters including necessary fittings and fixtures (Note : Items such as i) Wiremesh, ii) Glass, iii) Grill, iv) Rubber beeding, v) Rollers, vi) Locks, vii) Aluminium sections etc will be paid seperately under respective items as supply only)
Supply only ordinary sheet glass 4.8mm thick in square exc 0.5sqm in each panes.
S&F aluminium alloy anodized sliding door bolts with hasp & staple (bolt type) and fixing clips of sheet cast or extruded section and fixing bolts and sliding bolts 300mm long ,complete all as specified and as directed by Engr-in-charge.
S&F aluminum anodised frame powder coated( of approved colour) for doors, windows, ventilators with one or more rebates including joining cleat (min powder coating 50 micron) any track sliding windows/ Doors/Partition frames with aluminum sections mentioned in catalogue of approved manufacturer including suitable Nylon beading, channel gasket, nylon rollers, star lock with handle with complete fittings including water tightening using silicon compound all around etc complete all as specified and as directed by Engr - in- Charge. (Note : Glass, wire cloth shall be measured under respective items)
Supply only PVC Star lock for Aluminium windows ,complete all as specified and as directed by Engr-in-charge.
Supply only Nylon / PVC Rollers for Aluminium Windows ,complete all as specified and as directed by Engr-in-charge.
Supply only Rubber beeding suitable for aluminium door/window shutters ,complete all as specified and as directed by Engr-in-charge.
S&F 300mm mild steel helical door spring including roller plate ,complete all as specified and as directed by Engr-in-charge.
M &L for 12 mm Prelaminated particle board, interior grade, prelaminated one side with decorative choice lamination & other side balancing white lamination, fixed with screws to timber frame work ,complete all as specified and as directed by Engr-in-charge.
S & F in Continuous (piano) hinges, mild steel, bright finish or electro galvanised width of flap is 30mm when open ,complete all as specified and as directed by Engr-in-charge.
Dismantling floor hearth or wall tilling including cement mortar bedding ( but not backing) all as specified by Engr-in-charge.
M&L for machine cut cuddappa stone slab 20 to 25 mm thick as in cills/jambs of window & door openings, set jointed and pointed in neat cement slurry with grey cement slurry mixed with pigment to match the shade of the slab incl rubbing and polishing complete including 15mm thick backing coat in cement mortar 1:6 ,complete all as specified and as directed by Engr-in-charge.
M&L Chequered cement concrete tiles 20cm x 20cm x 25mm thick, set, jointed and pointed in neat cement slurry in floors with grey cement and pigments over cement screed bed of 20mm thick in CM 1:6 ,complete all as specified and as directed by Engr-in-charge.
M&L Coloured Glazed Ceramic tiles 300 x 450 and 6-7mm thick on vertical surfaces such as skirting, dados and risers to steps etc including 10mm thick backing coat in CM 1:4 complete all as specified and directed by Engineer-in-Charge..
M&L for Painting two coats over a coat of red oxide primer to old steel surfaces of any description, over 10cm in width or girth,not otherwise described including preperation of new surfaces ,complete all as specified and as directed by Engr-in-charge.
M&L for Sub Main wiring with two single core 6 Sqmm PVC insulated FRLS multistranded flexible copper conductor cable 660/1100 volts grade drawn in through flexible non metallic PVC conduit with and including PVC insulated 6 Sqmm multi strand copper conductor as continuous earth wire in green colour connected to common earth dolly and making the good disturbed surfaces of wall in CM 1:3 with white wash or existing colour ,complete all as specified and as directed (Note : PVC cable and PVC conduit shall be ISI marked) ( Make of cable - Havells/Anchor/Finolex) Note :- Two length of 6 Sqmm cable and one length of 6 Sqmm earth cable along with PVC conduit will be measured as one running length
Taking down carefully point wiring and removing from site such as (Light,fan socket or power) Complete including fitting and fixtures,fan regulators switch boards,switches,ceiling rose's lamp holder from existing batten PVC conduit/steel conduit wiring complete excluding light fittings and fans all as specified and making good to the disturbed surfaces to match with existing ,complete all as specified and as directed
M & L for concealed conduit point wiring complete for light/ fan on independent /combine board with cable 1.5 sqmm (Nominal area) FRLS PVC insulated multistranded unsheathed copper conductor, drawn in and including PVC Concealed conduit pipe medium grade 20 mm dia, pipe hooks , elbows, juction covers and junction boxes , after cutting in wall chasing for conduits and sinking's for sunken cast iron/ pressed steel terminal boxes suitable length and thickness for mounting, switches, sockets,fan regulator with 3 mm thick plastic laminated sheet cover fixed with cadmium plated machine screws and cup washers, duly grouting and painted with red oxide metal primer and making the good disturbed surfaces of wall in CM 1:3 with white wash or existing colour including provision of continuous earth continuity conductor along with point wiring of 1.5 sqmm copper PVC insulated cable for one light/ fan point controlled by one switch and connected to common earth dolly, complete all as specified and direced by the Engineer in charge.(Make of cable - Havells/Anchor/Finolex and conduit pipe:-AKG/Finolex/Supreme)
All as per Srl item No -56.00 here in before but for one socket outlet 5/6 amp on independent board complete all as specified and directed
All as per Srl item No -56.00 here in before but for one three pin socket outlet 5 Amp on same board with other switches complete all as specified and directed
All as per Srl item No -56.00 here in before but for one switch socket combinationt 6 pin 6/ 16 Amps on independent board with copper conductor 2.5 Sqmm complete all as specified and directed
S & F ceiling rose surface bakelite three terminals ,complete all as specified and as directed by Engr-in-charge.
S&F Switch piano, flush type single pole, one way 5 Amp ,complete all as specified and as directed by Engr-in-charge.
S&F Switch piano, flush type single pole, one way 16 Amp ,complete all as specified and as directed by Engr-in-charge.
S&F Socket outlet 2 in 1, 5 pin, 5A ,complete all as specified and as directed by Engr-in-charge.
S&F Socket outlet 2 in 1, 6 pin, 6/16A flush type ,complete all as specified and as directed by Engr-in-charge.
S&F Electronic bell AC 230 Volt single pole ding dong type ,complete all as specified and as directed by Engr-in-charge.
S & F stepped type,single socket fan regulator for ceiling fan 1200/1400mm sweep ,complete all as specified and as directed by Engr-in-charge.
S & F angle holder insulated body with back plate including led bulb 9W for conduit fittings ,complete all as specified and as directed by Engr-in-charge.
S & F sheet metal enclosure for double door DB made out of CRCA mild steel sheet surface with insulated material like polyester with epoxy powder coated surface mounted SP & N 8 ways, 240 Volts, ISI marked 200 amps bus bar stove enameled dust and vermin proof, IP 42 suitable for incorporation MCBs and isolators etc including taking down unserviceable old DB any type including MCB etc and including making good disturbed surfaces of walls as necessary ,complete all as specified and as directed by Engr-in-charge.
S & F MCB ‘B’ series type suitable for 240 volts, AC supply 6 to 32 Amps, S P & N with over load and short circuit protection and rupturing capacity not less than 10KA ,complete all as specified and as directed by Engr-in-charge.
S & F MCB ‘B’ series type suitable for 240 volts,10 KA, AC supply 6 to 32 Amps , single pole (SP) with over load and short circuit protection and rupturing capacity not less than 10KA ,complete all as specified and as directed by Engr-in-charge.
Taking down carefully existing serviceable LED Tubelight/ bulkhead/ security light of any size and refixing the same to respective location after carrying out cleaning all the components of fittings, including replacement of nuts, bolts and connection with flexible cable copper conductor twin core of size 23/.2 mm upto ceiling rose/connector,complete all as specified and as directed by Engr-in-charge.
S & F LED Tubelight fitting with polycarbonate housing and integrated electronic driver, 20 watt having input voltage AC90-300V, 50 Hz , 6500K, surge protection min 4 KVA and all other accessories including connection with flexible cable copper conductor twin core of size 23/.2 mm upto ceiling rose/connector ,complete all as specified and as directed by Engr-in-charge.
S & F LED Water tight bulk head fitting 10 W,comprision of connector galvanised cast iron back plate,weather proof enamelled gallery ,glass well,and including 10 watt LED ,complete all as specified and as directed by Engr-in-charge.
M&L for Disconnecting electric connection and taking down carefully serviceable ceiling fans,exhaust fan and Geyser and keep in safe custudy. After the building repair work or as directed refixing /hanging the ceiling fan and geyser including electric connection with and including new flexible sheathed copper wire 3 core from ceiling rose/connector to fan connector, including in replacement new nut bolts, rubber reel, capacitor 2.5mfd, machine screws and split pins etc including painting the ceiling fan,exhaust fan complete body with blades, canopies, down rod etc. with synthetic enamel paint by spray gun after scraping down old paint in colour as directed complete all as specified
S&F Heavy duty metal body exahust fan of 300mm sweep ,240 volt,copper winding, complete with louvers and shutter and mounted in suitable opening arrangement in wall and connecting up including 3 core PVC insulated PVC sheathed copper conductor flexible cable 24/0.2mm from ceiling rose to fan complete including breaking of brick wall and making a hole for fixing of exhaust fan including grouting of bolts and making good to distubed wall in cement mortar (1 :4) white washing matching with existing colour etc ,complete all as specified and as directed by Engr-in-charge.
S&F ceiling fans AC single phase 230/240 V of size 1200 mm sweep without regulator having Min air delivery 210 CFM with service value 6.00 BEE 5 star rated with brushless direct current motor (BLDC) complete with electrical connection providing three core round flexible copper conducter cable of suitable size complete all as specified and directed . MAKE: Orient electric 1200mm hector 500. Havells effeciencia neo 1200mm, Cromption Energin HS.
Vishal Builders
M/s Mukesh Engineers
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .