Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹9.7 LAccepted-AOC SHOP NO 12 KHOPKAR APARTMENT KUMBHARAWADA URAN DISTT RAIGAD 400 702 | URAN | RAIGAD | MAHARASHTRA | 400702 | L1 | Accepted-AOC AWARD OF CONTRACT | |
| 2 | L2₹13.4 L+₹3.4 L (34.1%)Rejected-Finance FLAT NO 404 A WING HILL SIDE RESIDENCY BEHIND KIRTI POLICE SOCIETY KATRAP BADLAPUR EAST DIST THANE MAHARASHTRA 451503 | 451503 | L2 | Rejected-Finance BEING L2 | |
| 3 | L3₹14.6 L+₹4.6 L (46.2%)Rejected-Finance | L3 | Rejected-Finance BEING L3 |
Tender Value
₹10 L
EMD Value
₹20,000
Closing Date
22 Feb 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE AF THANE
The Garrison Engineer (AF) Thane Kolshet Road, Sandoz Baugh Post, Thane 400607
REPAIR/MAINT OF SUMMER APPLIANCES WITH PLANT AND ACCESSORIES AT AF STATION KANHERI HILLS UNDER GE AF THANE
2020_MES_402608_2
8978/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
THANE
AS PER NIT
8 documents required · 8 mandatory
₹500
GE AF THANE
₹20,000
Yes
30 Jun 2021
1 Feb 2021
24 Feb 2021
1 Feb 2021
22 Feb 2021
9 Feb 2021
1 Feb 2021 - 9 Feb 2021
60 days
Amount
Supply only, PCB circit for intelligent cooling ambient sensor suitable for 8.75 TR AC plant. Make: Blue star
Supply only, DLT sensor suitable for 8.75 TR AC plant. Make: Blue star.
Supply only, Acoustic insulation suitable for 8.75 TR AC plant .Make: Blue star
Supply only, thermostate suitable for 8.75 TR AC plant. Make: Blue star
Supply only, PVC blade for condenser blower suitable for 8.75 TR AC plant. Make: Blue star
Supply only, Filter suitable for 8.75 TR AC plant .Make: Blue star
Supply only, PCB circit for intelligent cooling ambient sensor suitable for 7.0 TR AC plant Make: SCHNEIDER LEONARDO. At AFStn Kanheri Hills Top .
Supply only, DLT sensor suitable for 7.0 TR AC plant .Make: SCHNEIDER LEONARDO. At AFStn Kanheri Hills
Supply only, Acoustic insulation suitable for 7.0 TR AC plant. Make: SCHNEIDER LEONARDO.
Supply only, thermostate suitable for 7.0 TR AC plant.Make: SCHNEIDER LEONARDO.At AF Stn Kanheri Hills
Supply only, PVC blade for condenser blower suitable for 7.0 TR AC plant.Make: SCHNEIDER LEONARDO.
Supply only, Filter suitable for 7.0 TR AC plant. Make: SCHNEIDER LEONARDO.
M&L for Dismantling Solar Water Heater Tank 300 Litre capacity by taking out the Outer Cladding, Glass Wool and repairing old unserviceable Inner Tank made of Stainless Steel Sheet of 16 Gauge with Nut, Bolts, from the existing location after disconnecting eletric and water connection carefully and open the all spare parts and clean mud from inner water tank and refixing in same position and Testing upto satisfactory performance, complete all as specified and as directed by Engr-in-charge. Note : Necessary arrangement for servicing solar panel and tank at roof of building will be made by contractor and no extra payment shall be made on this account.
M&L for Dismantling Solar Water Heater Tank 500 Litre capacity by taking out the Outer Cladding, Glass Wool and repairing old unserviceable Inner Tank made of Stainless Steel Sheet of 16 Gauge with Nut, Bolts, from the existing location after disconnecting eletric and water connection carefully and open the all spare parts and cleanded mud from inner water tank and refixing in same position and Testing upto satisfactory performance, complete all as specified and as directed by Engr-in-charge. Note : Necessary arrangement for servicing solar panel and tank at roof of building will be made by contractor and no extra payment will be made on this account.
Taking down Solar Water Heating System Collector Panel 300 LPD/ 500 LPD from its Position, removing the Top Glass of Solar Heat Collector and carry out welding/ brazing work to the Collector and arresting the leakages in the Collector, replacement to broken glass Glass and Testing for proper and satisfactory Functioning, complete all as specified and as directed by Engr-in-charge.
M&L for, Cleaning, washing to Solar Glass Panel of Solar Water Heating System and Painting to Mild Steel Stand of Solar Water Heating System and Mild Steel Staging of Cold and Hot Water Tank with Synethic Enamelled Paint (White Colour), complete all as specified and as directed by Engr-in-charge.
S&F, Heating Element suitable for Solar Water Heating Plant of capacity 3.0 KW, 25mm to 32mm dia, ISI Mark, complete all as specified and as directed by Engr-in-charge. MAKE : BAJAJ/ DITZ/ POWER PACK/ THEETA
S&F Thermostat suitable for Solar Water Heating Plant suitable size and ratings, etc., complete all as specified and as directed. MAKE : BAJAJ/ DITZ/ POWER PACK/ THEETA,
M&L for, Rotational Moulded Polyethylene Water Storage Tank 100 Litre Capacity (Cylindrical, Vertical with Closed Top), triple layered, hoisted and fixed in Position all as specified in MES Schedule Part-I including dismantling/ lowering down unserviceable Water Storage Tank, complete all as specified and as directed by Engr-in-charge. MAKE : SINTEX / POLYCON
S&F ,outer cover of inner tank of electric water heater suitable for 25 ltr capacity ,made up of MS sheet cover 1.6 mm thick, complete all as specified and directed by Engr-in-charge.
S&F,apparatus plate suitable for Geyser 25/50 Ltrs Capacity, complete all as specified and directed by Engr-in-charge.
M & L for Gasket Rubber Ring for Heater Plate for 25 Liter Capacity Geyser, complete all as specified and directed by Engr-in-charge.
M & L for PVC Connection 15mm dia size ISI marked with PTMT Nuts of length 450 mm, complete all as specified and directed by Engr-in-charge. MAKE : POLYTUF/ PRAYAG
M & L taking down/lowering unserviceable Geyser 25/50 Litre capacity of any Make and type from any height by disconnecting all Water and Electric Connections for repairing Inter Connection Assembly, Heating Element, Thermostate, Safety Valve and other Accessories and removing all rusted Nuts, Bolts, de-scaling Inner Tank and Inter Connection Assembly of 25/50 Litre capacity and cleaning thoroughly with diluted Acid, Brazing/Gas Welding of Inter Connection Assembly, checking of Inner Tank to make Fully Leakeage Proof and Testing the same with Water Filling/Air Pressure and re-assembling the Geysers complete with all Accessories i.e. Rubber Gasket, Heating Element, Thermostat, Indicator (Red/ Green) Plug, Safety Valve, Inter Connection Assembly, Nut, Bolts and Glass Wool, etc. re-mounting the same to its existing position including Water/ Electric Connection and Testing on completion to the entire satisfaction of Engineer-in-Charge. NOTE :- (a) Quoted Unit Rate is deem to be included for taking down old unserviceable Accessories and fixing new Accessories including deposit unserviceable Water Heater of any capacity to AGE E/M Store and collection to repaired Water Heater from AGE E/M Store for fixing at required Site is responsibility of Contractor. (b) Cost of Accessories measured and paid under appropriate Items here-in-after.
S&F Galvanised Iron Tubing 15mm bore (dia), 'medium grade' with all Fitting and fixing to Walls and Ceilings or laid in Floors, , complete all as specified and directed by Engr-in-charge.. MAKE : JINDAL/ TATA
S&F Galvanised Iron Tubing 20mm bore (dia), 'medium grade' with all Fitting and fixing to Walls and Ceilings or laid in Floors, , complete all as specified and directed by Engr-in-charge. MAKE : JINDAL/ TATA
Taking out leakage storage type water heater 25/50 ltr capacity, dismantling and taking out the inner tank, find out the leakage point brazing the leakage point and replacement of glass wool insulations using glass wool and refixing the same after testing , complete all as specified and directed by Engr-in-charge.
S&F,in repair, heating element 2000 Watt cap single phase 230 V AC 50 Hz , complete all as specified and directed by Engr-in-charge.
S&F,in repair, heating element 1500 Watt capacity single phase 230 V AC 50 Hz of existing make for 25 ltrs capacity , complete all as specified and directed by Engr-in-charge.
S&F,in repair, NRV 15mm bore of gun metal or brass for storage type water heater at AF Stn Kanheri Hills , complete all as specified and directed by Engr-in-charge.
S&F,in repair, pressure release valve 15 mm dia for out let from water heater at AF Stn Kanheri Hills , complete all as specified and directed by Engr-in-charge.
S&F,in repair, CP connecting pipe 15mm dia for outlet from water heater at AF Stn Kanheri Hills , complete all as specified and directed by Engr-in-charge.
M&L,for Syphon Assembly suitable for Geyser 25/50 Litre capacity including Rubber Gaskets with Nut, Bolts & Washers, complete all as specified and as directed at AF Stn Kanheri Hills , complete all as specified and directed by Engr-in-charge.
M&, for Indicating neon Lamp Red / Green, Round/Square in shape, suitable for Geyser 25/50 Litre, , complete all as specified and directed by Engr-in-charge.
M&L for Thermostat Switch, ISI Mark for 25 litre capacity, complete all as specified and directed by Engr-in-charge.
M & L for Safety Fusible Plug, ISI marked suitable for Geyser 25/50 Litre capacity, complete all as specified and directed by Engr-in-charge.
S&F Bib Cock 15mm bore (dia), Chromium plated , complete all as specified and directed by Engr-in-charge. MAKE : CERA / HINDWARE / MARC,
S&F Stop Valve 15mm bore (dia), Cast Copper alloy, Chromium Plated, Fancy type, screw down high pressure, crutch Handle, screwed both End for Iron Pipe, , complete all as specified and directed by Engr-in-charge.
Supply, Install, Test and commissionig water heater storage type, energy efficient, five star rating electric supplied and installed capacity 25 ltrs including conection with PVC pipe 450 mm long for incoming and outgoing water supply with all arrangement of hanging of water heater with required nut bolts, washers, complete all as specified and directed by Engr-in-charge. Make: Racold ETERNO SWIFT/Havells 25L Monza
S&F ,in repair ,Metal Clad Industrial Socket 16/20 Amp (as approved) , complete all as specified and directed by Engr-in-charge. MAKE : HAVELLS/ INDO ASIAN/ L&T/ STANDARD
S&F ,in repair ,Metal Clad Industrial Plug Top 16/20 Amp (as approved), , complete all as specified and directed by Engr-in-charge. MAKE : HAVELLS/ INDO ASIAN/ L&T/ STANDARD
Equipment & labour for servicing of Split type AC 1.5 Ton / 2 ton , Window type AC 1.5/ 2 Ton , water cooler, refrigerator, and deep freezer of any size & capacity by taking out from its position cleaning dirt, dust checking all the electrical connections and re fixing in its original position , complete all as specified and directed by Engr-in-charge .Note:-servicing of machine shall be carried out as and when required .
S&F,in repair, sealed type compressor unit re-appropriated by the manufactures suitable for Split type AC 1.5 TR capacity including nessessary fittings with existing unit , complete all as specified and directed by Engr-in-charge.
S&F,in repair, sealed type compressor unit re-appropriated by the manufactures suitable for Split type AC 2 TR capacity including nessessary fittings with existing unit , complete all as specified and directed by Engr-in-charge.
S&F,in repair, sealed type compressor unit re-appropriated by the manufactures suitable for Water cooler of cap 150 ltr. including nessessary fittings with existing unit , complete all as specified and directed by Engr-in-charge.
S&F,in repair, sealed type compressor unit re-appropriated by the manufactures suitable for Water cooler of capacity 80/40 ltr. including nessessary fittings with existing unit complet all as directed.
S&F,in repair, sealed type compressor unit re-appropriated by the manufactures suitable for Deep freezer of cap 400 ltrs. including nessessary fittings with existing unit , complete all as specified and directed by Engr-in-charge.
S&F,in repair, sealed type compressor unit re-appropriated by the manufactures suitable for Refrigerators 165 ltrs/ capacity. including nessessary fittings with existing unit , complete all as specified and directed by Engr-in-charge.
S&F,in repair, sealed type compressor unit re-appropriated by the manufactures suitable for Refrigerators 180/210 ltrs/ capacity. including nessessary fittings with existing unit ,complete all as specified and directed by Engr-in-charge.
S&F,in repair, magnetic gasket for Water cooler of capacity 80/40 ltr ,complete all as specified and directed by Engr-in-charge.
S&F ,in repair, screw/pin type shell light bulb 2.5 W ,complete all as specified and directed by Engr-in-charge.
S&F ,in repair, condenser coil for Split AC 1.0, 1.5 & 2.0 TR capacity ,complete all as specified and directed by Engr-in-charge.
S&F ,in repair, condenser coil of water cooler of capacity 80/40 ltr , complete all as specified and directed by Engr-in-charge.
S&F ,in repair, condenser unit for refrigaretor of capacity 180 ltr to 310 ltr , complete all as specified and directed by Engr-in-charge.
S&F,in repair, of chilling door for refrigaretor of capacity 180 ltr to 310 ltr , complete all as specified and directed by Engr-in-charge.
S&F,in repair, of chilling tray for refrigaretor of capacity 180 ltr to 310 ltr , complete all as specified and directed by Engr-in-charge.
S&F,in repair, of door push buttom for refrigaretor of capacity 180 ltr to 310 ltr , complete all as specified and directed by Engr-in-charge.
M&L,in repair, of capillary tube refrigerator for refrigaretor of capacity 180 ltr to 310 ltr , complete all as specified and directed by Engr-in-charge.
S&F,in repair, of capillary tube for Split type air conditioner 1.0/1.5/2.0 Ton , complete all as specified and directed by Engr-in-charge.
S&F,in repair, of capillary tube for water cooler of capacity 80/40 ltr , complete all as specified and directed by Engr-in-charge.
S&F,in repair, of housing (outer cover) for Split type AC of capacity 1.5 Ton to 2.0 Ton. , complete all as specified and directed by Engr-in-charge.
S&F,in repair, of front grill for AC of capacity 1.5 Ton to 2.0 Ton, complete all as specified and directed by Engr-in-charge.
S&F,in repair, of Indoor cabinet for split type AC of capacity 1.5 Ton to 2.0 Ton, complete all as specified and directed by Engr-in-charge.
S&F,in repair, of Outdoor cabinet for split type AC of capacity 1.5 Ton to 2.0 Ton, complete all as specified and directed by Engr-in-charge.
S&F,in repair, of drain tray of water cooler of capacity 80/40 ltr including PVC pipe clamps etc., complete all as specified and directed by Engr-in-charge.
S&F,in repair, of Indoor unit Blower Motor for split type AC of capacity 1.5 ton, complete all as specified and directed by Engr-in-charge.
S&F,in repair, of Indoor unit Blower motor for split type AC of capacity 2.0 ton, complete all as specified and directed by Engr-in-charge.
Supply only Remote control for Split/Window type AC of capacity 1.5 ton to 2.0 ton , complete all as specified and directed by Engr-in-charge..
M&L for PVC stickers of 20 mm of MES no made with computerized cutting to be pasted on equipment in proper shape as directed by Engineer in charge.Stickers with full MES No will be counted as one unit.For example"MES NO R-12345-S"
M&L for PVC stickers of 25 mm of MES no made with computerized cutting to be pasted on equipment in proper shape as directed by Engineer in charge.Stickers with full MES No will be counted as one unit.For example"MES NO R-12345-S"
S&F 8 mm dia post anchorage bolts for fixing of equipment on wall , complete all as specified and directed by Engr-in-charge.
Flushing out the Niterogen gas from condensing coil AC 1.5 Ton capacity, repairs of leaking place by gas welding complete and recharging of Refrigerant (R-12 & R-22 ), complete all as specified and directed by Engr-in-charge.(Note:-Refrigerant will measured and paid seperately under respective items of Sch A)
Flushing out the Niterogen gas from condensing coil AC 2 Ton cap complete and repairs of leaking place by gas welding complete and recharging of Refrigerant (R-12 & R-22 ) , complete all as specified and directed by Engr-in-charge.(Note:-Refrigerant will measured and paid seperately under respective items of Sch A)
Flushing out the Niterogen gas from condensing coil Water cooler of cap 150/150, 120/60 and 80/40 ltrs complete and repairs of leaking place by gas welding complete and recharging of Refrigerant (R-12 & R-22 ) , complete all as specified and directed by Engr-in-charge.(Note:-Refrigerant will measured and paid seperately under respective items of Sch A)
Flushing out the Niterogen gas from condensing coil Refrigerator of any cap and make.complete and repairs of leaking place by gas welding complete and recharging of refrigerant (R-12 & R-22 ) , complete all as specified and directed by Engr-in-charge.(Note:-Refrigerant will measured and paid seperately under respective items of Sch A)
Flushing out the Niterogen gas from condensing coil Deep freezer upto 400 ltr capacity.complete and repairs of leaking place by gas welding complete and recharging of refrigerant (R-12 & R-22 ) , complete all as specified and directed by Engr-in-charge.(Note:-Refrigerant will measured and paid in seperately under respective items of Sch A)
Supply and recharging Refrigerant for any type (R-12 & R-22 ) , complete all as specified and directed by Engr-in-charge.
S&F,in repair, air filter for split/window Air conditioner of capacity 1.5 ton to 2.0 ton , complete all as specified and directed by Engr-in-charge.
S&F,in repair, relay suitable for cap for AC 1.5/2 ton , complete all as specified and directed by Engr-in-charge.
S&F,in repair, relay suitable for water cooler 40/80 capacity , complete all as specified and directed by Engr-in-charge.
S&F,in repair, relay suitable for Deepfreezer upto 400 ltr capacity , complete all as specified and directed by Engr-in-charge.
S&F,in repair, relay suitable for capacity 80/120 ltr water cooler, complete all as specified and directed by Engr-in-charge.
S&F,in repair, relay suitable for capacity 120/150 ltr water cooler , complete all as specified and directed by Engr-in-charge.
S&F,in repair, of starting capacitor 36 MFD for Split/window type AC , complete all as specified and directed by Engr-in-charge.Make: Havells, Sardar
S&F,in repair, of capacitor 6 MFD , complete all as specified and directed by Engr-in-charge.
S&F,in repair, of capacitor 15 MFD , complete all as specified and directed by Engr-in-charge.
S&F,in repair, of Capacitor 8 MFD , complete all as specified and directed by Engr-in-charge.
S&F,in repair, of Capacitor 4 MFD, complete all as specified and directed by Engr-in-charge.
S&F,in repair, of PVC hose pipe for water cooler of capacity 80/40 lit , complete all as specified and directed by Engr-in-charge.
Supply and installation of ceiling rotated air circulator, 1200 mm sweep energy efficient ,five star rating 220V AC 50 Hz , complete all as specified and directed by Engr-in-charge.
Supply and installation of ventalation rotated air circulator 230 mm sweep 220V AC 50 Hz complete all as specified and as directed. Make havells Ventil air DSP,
Disconnecting and taking out brunt out blower motor of Split type AC 1.5 Ton capacity, opening the motor and removing burnt out winding and rewinding the same with super enameled copper wire of existing gauge and reconnecting in the same position , complete all as specified and directed by Engr-in-charge.
all as per item No-82 above but for blower motor of water cooler of capacity 80/40 ltr
all as per item No-82 above but for blower motor for Deepfreezer/refrigaretor of capacity 310 to 400 lit .
S&F,in repair, of burn out thermo-state switch ,suitable for Split/Window type AC1.0/ 1.5/2.0 Ton capacity , complete all as specified and directed by Engr-in-charge.
S&F,in repair, of burn out thermo-state switch, suitable for water cooler of capacity 80/40 ltr , complete all as specified and directed by Engr-in-charge.
S&F,in repair, of burn out thermo-state switch suitable for Refrigerator of capacity 180 to 310 lit . , complete all as specified and directed by Engr-in-charge.
S&F,in repair, of burn out thermo-state switch suitable for Deep freezer of capacity 400 lit , complete all as specified and directed by Engr-in-charge.
Removing the worn out old paint from surface of split unit AC of capacity 1.5 ton to 2.5 ton external, scraping,cleaning the old paint and repainting with proper colour as approved on external surface over a coat of red oxide primer by spray painting till smooth finished ,complete all as specified and directed by Engr-in-charge.
Removing the worn out old paint from surface of water cooler of capacity 80/40 ltr, scraping, cleaning the old paint and repainting with proper colour as approved on external surface over a coat of red oxide primer by spray painting till smooth finished , complete all as specified and directed by Engr-in-charge.
Removing the worn out old paint from surface of water heater 25/50 ltr capacity, scraping, cleaning the old paint and repainting with proper colour as approved on external surface over a coat of red oxide primer by spray painting till smooth finished , complete all as specified and directed by Engr-in-charge.
M&L for cutting and taking out the rusted/damaged portion of the sheet metal of AC (1.5/2.00 ton ) /WATER COOLER ( Capacity 80/ 40 ltr) /DEEP FREEZER ( Capacity 400 ltr) /REFRIGERATOR (Capacity 310 to 400 ltr) and providing new sheet of exiting gauge including welding/brazing as required and painting with two coat of red oxide primer.
S&F, in repair ,glass wool for any type of WATER cooler ( Capacity 80/ 40 ltr) /DEEP FREEZER (Capacity 400 ltr) /Refrigerator (Capacity 310 to 400 ltr) / GEASER( Capacity 25 ltr) with rubber gasket packing with nut bolts etc complete.all as specified and directed.
S&F, in repair ,copper/GI inner water tank of capacity 25 Ltr water heater with necessary gasket packing. with nut bolts etc ,complete all as specified and directed by Engr-in-charge.
S&F,in repair ,PCB of 1.0,1.5 Ton and 2 Ton Split type AC ,complete all as specified and directed by Engr-in-charge.
S & F, in repair , 24 Hours timer for operating 1.5/2 TR split type in 4 to 8 hours time intervals ,complete all as specified and directed by Engr-in-charge.
S&F of Swing motor for split type AC of Capacity 1.5 /2TR,complete all as specified and directed by Engr-in-charge.
S&F Evaporator fan for split type AC of Capacity 1.5 /2TR,complete all as specified and directed by Engr-in-charge.
S&F of Air filter pads PVC type for Split/window type AC of Capacity 1.5 /2TR ,complete all as specified and directed by Engr-in-charge.
S&F 3 way backlite connector of capacity 20Amps ,complete all as specified and directed by Engr-in-charge.
S&F, Cripser tray for refrigerator of Capacity 180/310 ltr,complete all as specified and directed by Engr-in-charge.
S&F, Filter drier for refrigerator of Capacity 180/310 ltr,complete all as specified and directed by Engr-in-charge.
M&L for dismantling the indoor and outdoor units of Air conditioner Window/Split type capacity 1.5 /2TR completely, transporting to Workshop for carrying out repairs, transporting back to the site, reinstalling the same on the new /existing location complete all for satisfactory functioning of the equipment all as directed by Engr-in-charge. Note:- 1. Spare Parts replaced during the proces of repair shall be measured and paid separetely under relivant item of Sch A. 2. Rates include the cost of dismantling and transporting the AC to workshop and labour element for carrying out repairs/replacement. 3 The decision the Engineer -in -charge shall be final and binding ,for machine is required to be sent to workshop for repair or not.
All as per item No. 103 here in before but for water cooler of Capacity 80/40 ltr.
All as per item No. 103 here in before but for refrigerator/deepfreezer of Capacity 180/310 ltr.
S&F,in repair, MCB SP 5 to 30 Amps 10 KA ,complete all as specified and directed by Engr-in-charge.
S&F,in repair, of sheet metal enclosure with socket plug single pole and nertral with 2 pin and earth plug and socket complete with and including MCB SP of 20 Amps capacity ,complete all as specified and directed by Engr-in-charge.
S&F,in repair, of 2.5 sqmm 3 core PVC Sheathed multi-stranded flexible copper cable up to 1.5 mtrs long including connecting upto existing ,complete all as specified and directed by Engr-in-charge.
M&L for dismantling the indoor and outdoor units of Air conditioner Window/Split type capacity 1.5 /2TRcompletely, re-installed in new location ,including connection ,commissioning ,complete all as specified and directed by Engr-in-charge.
Taking down submain wiring cable any number of runs alongwith eirth wire from the existing concealed or surface conduit ,complete all as specified and directed by Engr-in-charge.
M&L for Sub-main Wiring with 2-Runs of 6.0 Sqmm (nominal area) 1100 Volt PVC insulated unsheathed FRLS multi-stranded single core Copper Conductor Cable drawn through in existing conduit /PVC casing and caping and making good the disturbed surface of wall including 1-Run of 4.0 Sqmm (nominal area) 1100 Volt PVC insulated unsheathed FRLS multi-stranded single core Copper Conductor Cable (Green Colour) as Earth Continuty Conductor along with the Wiring in Concealed and Making Good Disturbed Surfaces of Walls/Roofs/Floors, etc. so as to match with the Existing Finishes,,complete all as specified and directed by Engr-in-charge.
M&L Sub-main Wiring with 2-Runs of 4.0 Sqmm (nominal area) 1100 Volt PVC insulated unsheathed FRLS multi-stranded single core Copper Conductor Cable drawn through in existing conduit /PVC casing and caping and making good the disturbed surface of wall including 1-Run of 2.5 Sqmm (nominal area) 1100 Volt PVC insulated unsheathed FRLS multi-stranded single core Copper Conductor Cable (Green Colour) as Earth Continuty Conductor along with the Wiring in Concealed and Making Good Disturbed Surfaces of Walls/Roofs/Floors, etc. so as to match with the Existing Finishes ,complete all as specified and directed by Engr-in-charge.
S&F ,MCB starter single phase current capacity 20 Amps including box suitable for operation of AC 1.5 TR/2.0 TR Capacity ,complete all as specified and directed by Engr-in-charge.Make-Havells/Legrand/Indoasian/North west
Supply, installation, testing and commissioning of high pressure copper R-22/R410A refrigent copper pipe 19mm/13mm thick closed cell elastomeric insulation in tubing ,complete all as specified and directed by Engr-in-charge.
S&F ,raceways PVC duct cover 100mmx38 mm with 2 compartment, 2 mtr length, ,complete all as specified and directed by Engr-in-charge.
M&L for Dismantling Solar Water Heater Tank 500 Litre capacity from Solar Water Heating System, taking Out from Building and Provision of Solar Water Heater Tank, made from Stainless Steel Sheet of 16 Gauge with Nut, Bolts, etc. as per existing and re-fixing the same in Original Position including connecting with Water and Electric Connection and Testing upto satisfactory performance ,complete all as specified and directed by Engr-in-charge.
M &L for cleaning of fins by means of chemical wash with water of Window type AC 1.5/ 2 Ton, water cooler, refrigerator, and deep freezer of any size & capacity by taking out from its position cleaning dirt, dust checking all the electrical connections and re fixing in its original position, all as directed. Note:- Cleaning of Fins of above mentioned item of when required basis
M/S SOMANATH ENTERPRISES
PRABHA ENTERPRISES
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .