Tender ID
Tender Value
₹9.0 L
EMD Value
₹18,000
Closing Date
17 Feb 2026, 5:00 pmClosed
Jagmal
DIV 1 Rohtak
Annual Maintenance Estimate for Sewerage Scheme in Sector-1, Rohtak for the year 2025-26.
2026_HBC_501709_1
2026F107D49E B363 42C1 B9FB 04E5A6DADF48267HSV
Open Tender
Civil Works
Works
90 days
Rohtak
As per approved DNIT/NIT/CBD
2 documents required · 2 mandatory
₹500
₹18,000
Yes
19 Feb 2026
10 Feb 2026
18 Feb 2026
10 Feb 2026
17 Feb 2026
10 Feb 2026
[14.51.3]Hire charges for Hydraulic excavator/Loader like JCB/Pock lain, Hitachi etc with all accessories having bucket capacity 3. Hire Charges for excavator with over 0.75 cum bucket capacity
[20.10.7]Extra for fixing sluice valves/flap valves socketed or flanged including cartage from stores or nearest Railway Station to site of works 7. 350 mm i/d
[20.114.9]Supplying erection, testing of fully automatic electric control panel board for T/Wells in Pump Chamber consisting of MS sheet of thickness 14 gauge duly painted box type floor mounted made of angle Frame containing 1 no. fully automatic air brake starter suitable for Motor of the following capacity, Min switch of suitable range with HRC fuse, 1 no. volt meter (0 to 500 volts), 1 No. Amp. Meter of 0 to 100 amp. 3 sets of indicating lamp capacitor of suitable capacity and 1 no. single phase preventers with the timer switch including wiring in panel board and suitable electric energy meter wiring in Electric Control Panel Board complete in all respect as per specification given in Schedule No. II, Including MCB, suitable, Capacitor, Wooden Box etc as per site requirement complete in all respect. 9. 50 HP Motor
[20.68.1]Providing, lowering, laying in trenches, aligning, fixing in position and jointing at all level/depths Ductile Iron (DI) standard specials plain /flanged/ socketed confirming to IS9523-2000 with rubber ring (EPDM/SBR) joints such as tees, bends, tapers, caps etc. with in trenches in DI pipe line complete including all material, labour, testing and commissioning along with pipe line as per Technical Specifications and as per direction of Engineer. 1. Up to 300mm dia
[20.68.2]Providing, lowering, laying in trenches, aligning, fixing in position and jointing at all level/depths Ductile Iron (DI) standard specials plain /flanged/ socketed confirming to IS9523-2000 with rubber ring (EPDM/SBR) joints such as tees, bends, tapers, caps etc. with in trenches in DI pipe line complete including all material, labour, testing and commissioning along with pipe line as per Technical Specifications and as per direction of Engineer. 2. Above 300mm dia and up to 600mm dia
[22.162.6.1]Providing and fixing C.I. sluice valves (with cap) complete with bolts, nuts, rubber insertions etc. (the tail pieces if required will be paid separately) : 6.1. 300 mm diameter Class I
[24.12.82]LT CABLES (Aluminium Conductor, Armoured and Unarmoured) PROVIDING AND ERECTION/ LAYING OF PVC/ XLPE INSULATED UNDERGROUND ALUMINIUM CONDUCTOR CABLE 0.75 METER BELOW GROUND LEVEL COVERED WITHOUT SAND AND BRICKS INCLUDING EXCAVATION AND REFILLING OF TRENCHES 82. 185 Sq mm 3.5 core (Arm.)
NS Item) Repairing of 80 HP non clog sewerage motor including cost of rewinding, sewage seal, oil, etc. complete in all respect as per entire satisfaction of Engineer – in – Charge.
NS Item ) Repairing/ rewinding of 40 HP non clog sewerage motor including cost of 48mm dia, shaft, sewerage disposal seal etc. pump Machinening complete in all respect as per entire satisfaction of Engineer – in – Charge.
stage.html
html • 0.02 MB
cancelled_1.pdf
pdf • 0.48 MB
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.83 MB
BOQ_580350.xls
BOQ • 0.30 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .