Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹35.2 LAccepted-Finance 202 400 602 | THANE | MAHARASHTRA | 400601 | L1 | Accepted-Finance LOWEST | |
| 2 | L2₹44.2 L+₹9.0 L (25.7%)Rejected-Finance | L2 | Rejected-Finance HIGHEST | |
| 3 | Rejected-Technical | - | Rejected-Technical DISQUALIFIED |
Tender Value
₹2.2 Cr
EMD Value
₹1.5 L
Closing Date
16 Jun 2022, 3:00 pmClosed
chief offficer ambernath municipal council
Ambernath municipal council,Kalyan-Badlapur Road, Ambarnath West
Operationand maintenance of sewage treatment plants having capacities 45 MLD at Vadolgaon and 09 MLD at Chikhloli with pumping stations and all allied electrical works including 750 KVA, 1600 KVAand2000 KVA transformers and all allied works of STP
2022_DMA_793442_1
AMC/WS/2022-23/439
Open Tender
Civil Works
Item Rate
1080 days
Ambernath
Please refer Tender documents.
3 documents required · 3 mandatory
₹2,360
₹1.5 L
Ambernath municipal council
4 Oct 2024
29 Apr 2022
17 Jun 2022
29 Apr 2022
16 Jun 2022
29 Apr 2022
13 May 2022
Amount
Labor Part for 45 MLD and 9 MLD
Providing & supplying Resident Engineer (Electrical /Mechanical) for day to day electrical & mechanical maintenance along and overall running of pumping stations
Providing & Supplying Laboratory Technician for analysis of parameters for Laboratory and controlling for the chlorination and polydosing units of STPs
Providing & Supplying Electrical Mechanical supervisor for attending electrical preventive and breakdown work in ‘G’ Shift for pumping station & STP
Providing & Supplying pump operator (Skilled) one for each shift in three shift round the clock for operation of pumping stations & STP
Providing & Supplying labor/MajdoorSkilled for day to day preventive maintenance , breakdown work work pumping stations
Security Guards for All plant
Repairs and Maintenance part for Machinery
Repairing / overhauling of sewage submersible pump up to 250 KW including removing from wet well reinstallation and replacement of mechanical seal, bearing, replacement of lubricating oil motor rewinding , cable, SS chain, guide pip, testing for air leakage and satisfactory performance test etc complete including all Material and required labour and as directed by Engineer Incharge
Desilting the supply well intake well in wet or dry conditionby using proper safety devices and precautions etc compete including all Material and required labour and as directed by Engineer Incharge.
Reparing / overhauling of sewage submersible pump up to 7.5 HP including removing from SBR reinstallation and replacement of mechanical seal, bearing, replacement of lubricating oil motor rewinding , cable , SS chain , guide pip , testing for air leakage and satisfactory performance test etc complete including all Material and required labour and as directed by Engineer Incharge.
Replacement of Diffusers OF SBR - Dismentling and erection etc complete by appointing seprate Approved Agency etc Complete including all Material and required labour and as directed by Engineer Incharge.
Reapring/supplying and installing and giving satisfactory test , trial of Dissolve Oxygen Meter with calibration and obtaining signal at PLC guarantee for 6 month and warantee for further 1 year perodetc complete including all Material and required labour and as directed by Engineer Incharge. .
Servicing / Repairing / Overhauling of Chlorination system with all major and minor spares replacement of connecting pipes , dosing pump, flow control vale etc complete by appointing sepratespecalized approved agency including all Material and required labour and as directed by Engineer Incharge.
Oil filtration of transformer including all Material and required labour and as directed by Engineer Incharge.
Supplying and topping filtered transformer oil with test certificate including all Material and required labour and as directed by Engineer Incharge.
Supplying &erecting bank of all polypropylinecondensors (APP) with standard capacities of 2, 3,5,7,10,12.5 & 15 KVAR units of pf correction for operation on 3 phase 50 cycles 400/440 V (10 %) with external discharging resistence ,earthing terminal and built on angle iron or channel iron framewok and provided with terminal cover box complete erected on provided iron bracket or on floor duly tested by licency including all Material and required labour and as directed by Engineer Incharge.
Providing and supplying Lube Oil for oilinmechanical parts joints etc complete including all Material and required labour and as directed by Engineer Incharge.
Providing and supplying Normal Grease for greasing mechanical parts joints etc complete including all Material and required labour and as directed by Engineer Incharge.
Providing and supplying Special Bearing Grease for greasing DDM mixure motor LGHP 2/1 High temperature As per company Specification including all Material and required labour and as directed by Engineer Incharge.
Providing and supplying Liquid chlorine 100 kg including all Material and required labour and as directed by Engineer Incharge.
Providing and supplying Liquid chlorine 900 kg including all Material and required labour and as directed by Engineer Incharge.
Providing and supplying Ready Mix Oil Paint including all Material and required labour and as directed by Engineer Incharge.
Providing and supplying Ready Mix primer including all Material and required labour and as directed by Engineer Incharge.
Providing and supplying Ready Mix aluminum paint including all Material and required labour and as directed by Engineer Incharge.
Repairing of PLC panel of STP including SMPS cards, I/O cards, power supply, indicating lamps, relays, HMI units with software licenced key etc. complete including all Material and required labour and as directed by Engineer In charge.
Repairing of scada unit including display unit, software with licenced key etc. complete including all Material and required labour and as directed by Engineer Incharge.
Reparing of Blower unit 200 HP complete overhauling including replacement of piston, bearing,seal,casing, Drive Belts, Pulley , rewinding and O/H of motor with H class insulation, bearing, shaft,coulpingetc including all Material and required labour and as directed by Engineer Incharge.
Reparing of Blower unit 100 HP complete overhauling including replacement of piston, bearing,seal,casing, Drive Belts , Pulley , rewinding and O/H of motor with H class insulation, bearing, shaft,coulpingetc including all Material and required labour and as directed by Engineer Incharge.
Reparing of APFC Panel including replacement of Capacitor / APFC Relay / incicating Lamp /MCB/Insulator etc Complete including all Material and required labour and as directed by Engineer Incharge.
Repairing of VFD / soft starter upto200 HP including replacement of IGPT , Control Card , power Card , potintio Meter , etc complete including all Material and required labour and as directed by Engineer Incharge.
Sampling and testing of sewage inlet and outlet prescribed parameters at laboratory including necessary Chemicals and repairing / overhauling of existing equipment’s and providing additional necessary test equipment’s / augmentation of test equipment’s etc. complete including all Material and required labour and as directed by Engineer Incharge.
Reparing of Mechanical Screen including belt conveyer unit including motors and control panels etc complete including all Material and required labour and as directed by Engineer Incharge.
Reparing of Split AC up to 1.5 tonne capacity including overhauling replacing copper cable , compressor , relays , fan , PCB , capacitor and refilling of refrigaration gas etc complete including all Material and required labour and as directed by Engineer Incharge.
Reparing of Mechanical Grit Seprator including overhauling of Gear Box , motor ,Swiper arm and control panel etc complete including all Material and required labour and as directed by Engineer Incharge.
Repairing of Control valve / safety valve up to 300 mmdia including replacement of major and minor parts gasket etc complete including all Material and required labour and as directed by Engineer Incharge.
Reparing of decanter including solenoid valves, S.S parts,cable replacement of major and minor parts, including imported parts , gasket etc complete including all Material and required labour and as directed by Engineer Incharge.
Reparing/rewinding of upto 1600 KVA 22 KV/433 V distribution transformer including H.V./L.V. coil rewinding, Oil replacement, H.T/L.T busing replacement, To and Fro transportation, testing etc. complete including all Material and required labour and as directed by Engineer Incharge.
Reparing/rewinding of upto 2000 KVA 22 KV/433 V distribution transformer including H.V./L.V. coil rewinding, Oil replacement, H.T/L.T busing replacement, To and Fro transportation, testing etc. complete including all Material and required labour and as directed by Engineer Incharge.
Repairing of Star-Delta starter upto 50 KW including replacement of contactor,auto transformer, timer, digital ammeter/voltmeter, protection replay, terminal block, SFU, wires, indicating lamp, pump protection relay etc. complete with satisfactory test including all Material and required labour and as directed by Engineer Incharge.
Repairing of Star-Delta/ATS starter upto 250 KW including replacement of contactor, timer, digital ammeter/voltmeter, protection replay, terminal block, SFU, wires, indicating lamp, pump protection relay etc. complete with satisfactory test including all Material and required labour and as directed by Engineer Incharge.
Supplying and erecting asymmetrical beam integral flood light luminaries suitable for 150W metal halide lamp complete with accessories on provided bracket as per specification no. FG-ODF/GFL
Supplying &erecting T8 LED 18W tube light fitting (4 feet) withpolycarbonate housing, heat sink, integrated HF electronic driver complete (including lamp)
Providing and erecting panel mounted digital Multi functionMeter having three and half digit LED display, external C.T. operated, calibrated for 0-1000 A AC suitable to operate on 500 V AC supply with necessary PVC wire leads and lugs and mounting hardware on provide panel complete with calibration certificate from manufacturer including all Material and required labour and as directed by Engineer Incharge.
Supplying and erecting Aluminum ladder of reputed make 9 Mter height including all Material and required labour and as directed by Engineer Incharge
Supply T 5 28 W Energy Efficiantflurosant tube including all Material and required labour and as directed by Engineer Incharge.
Supply 18 W , 230 v intergral type LED lamp including all Material and required labour and as directed by Engineer Incharge.
Supplying and erecting starter upto from 150 HP to 350 HP including suitable size contactors, auto transformer, timer, digital ammeter/voltmeter, MPR, terminal block, SFU, wires, indicating lamp, pump protection relay etc. complete with prior drawing approval & with satisfactory test including all Material and required labour and as directed by Engineer Incharge.
Repairing of Centrifuge unit including rotating drum , motor, starter etc. complete including all Material and required labour and as directed by Engineer In charge.
Repairing of motorised unit of all valves including contactors, switch, gear unit etc. including all Material and required labour and as directed by Engineer In charge..
B) Hiring of Tipper -3.5 cum for Sludge Disposal including
Hiring of Tipper -3.5 cum capacity for Sludge Disposal purpose with diesel charges, maintenance, insurance, labour, etc. at 45 MLD STP and 9 MLD STP
Kishan Construction
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .