| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹10.4 LAccepted-AOC | ₹10.4 L Quoted ₹10.8 L | L1 | Accepted-AOC L1 bidder |
| 2 | L2₹12.1 L+₹1.3 L (12.0%)Rejected-Finance 58 CHANDRALOK BLDG MAYO HOSPITAL ROAD NAGPUR 440018 | NAGPUR | NAGPUR | MAHARASHTRA | 440018 | ₹12.1 L+₹1.3 L (12.0%) | L2 | Rejected-Finance Higher side quoted |
Tender Value
₹10 L
EMD Value
₹20,000
Closing Date
18 Dec 2019, 6:00 pmClosed
GE (AF) Amla
GE (AF) Amla Amla Depot Distt Betul (MP) 460553
Repair and maint of ceiling fans exhaust fans geysers and energy meter at AFS Amla
2019_MES_280993_3
8300/E8 of 2019-20
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE (AF) Amla
As per Notice of Tender
8 documents required · 8 mandatory
₹500
GE (AF) Amla
₹20,000
Yes
31 Mar 2020
6 Dec 2019
19 Dec 2019
6 Dec 2019
18 Dec 2019
7 Dec 2019
Amount
Taking down ceiling fan carefully from any height of any size, type and make after disconnecting the electrical connections and refixing back after carrying out servicing/ overhauling/ painting/ rewinding works etc., including cleaning of surface with detergent and replacing the damaged rubber reel, nuts and bolts with washers and safety pins as required complete all as directed.
Taking down Exhaust fan carefully from any height of any size, type and make after disconnecting the electrical connections and refixing back after carrying out servicing/ overhauling/ painting/ rewinding works etc., including cleaning of surface with detergent and replacing the damaged rubber reel, nuts and bolts with washers and safety pins as required complete all as directed. Note for item No. 1 & 2: The cost of these items is deemed to be included only taking down, cleaning and refixing. The cost of servicing/ overhauling/ painting/ rewinding works etc., will be measured and paid separately under appropriate items.
Taking down copper/aluminium point wiring (light, socket or power) complete, including fitting fixtures and fittings such as switches, ceiling roses, pendants, regulators, sockets etc. removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surface of walls, floors, etc. complete all as specified
Material and labour for transporting the unserviceable ceiling fans to local work shop opening the motor and taking out the old burnt out copper winding wire from the fan of 1200mm sweep and rewinding by using same gauge of copper wire insulating and varnishing including reassembling and testing complete all as directed.
Material and labour for transporting the unserviceable ceiling fans to local work shop opening the motor and taking out the old burnt out copper winding wire from the fan of 1400mm sweep and rewinding by using same gauge of copper wire insulating and varnishing including reassembling and testing complete all as directed.
Material and labour for transporting the unserviceable heavy duty exhaust fans to local work shop opening the motor and taking out the old burnt out copper winding wire from the fan of 300mm sweep and rewinding by using same gauge of copper wire insulating and varnishing including reassembling and testing complete all as directed.
Material and labour for transporting the unserviceable flame proof exhaust fan to local work shop opening the motor and taking out the old burnt out copper winding wire from the fan of 450mm sweep and rewinding by using same gauge of copper wire insulating and varnishing including reassembling and testing complete all as directed.
Material and labour for transporting the unserviceable flame proof ceiling fan to local work shop opening the motor and taking out the old burnt out copper winding wire from the fan of 1200mm sweep and rewinding by using same gauge of copper wire insulating and varnishing including reassembling and testing complete all as directed.
Material and labour for transporting the unserviceable flame proof ceiling fan to local work shop opening the motor and taking out the old burnt out copper winding wire from the fan of 1400mm sweep and rewinding by using same gauge of copper wire insulating and varnishing including reassembling and testing complete all as directed.
Material and labour for painting of ceiling fans of size 1200/1400 mm sweep complete including down rod and blades with two coats of synthetic enamel paint by spray painting, filling cavities with filler materials such as metal paste etc, after cleaning all dust complete all as directed and writing MES No. with black enameled paint all as directed.
Material and labour for painting of exhaust fans of size 300 mm to 450 mm sweep complete including mounting frame and blades with two coats of synthetic enamel paint by spray painting, filling cavities with filler materials such as metal paste etc, after cleaning all dust complete all as directed and writing MES No. with black enameled paint all as directed.
Supply and fix in repair ball bearing suitable for ceiling fans 1200/ 1400mm sweep complete all as specified and directed.
Supply and fix in repair ball bearing suitable for exhaust fans 300 mm to 450 mm sweep complete all as specified and directed.
Supply and fix in repair Capacitor 2.5 MFD 230 Volts with PVC clamps suitable for ceiling fans complete all as specified and directed.
Supply and fix in repair Capacitor 4.0 MFD 230 Volts with PVC clamps suitable for exhaust fans complete all as specified and directed.
Supply and fix in repair 1.5 Sqmm three core PVC flexible cable for connecting up ceiling fans, exhaust fans etc. from ceiling rose complete all as directed.
Supply and fix in repairs down rod for ceiling fans, 300 mm long GI pipe heavy grade, 15 mm dia complete including welding, painting as required complete all as specified and directed.
Supply and fix in repairs extra down rod of 10 cm length G.I. pipe, 15 mm dia, heavy grade including welding, painting etc., as required. (Note : More than 5 cm length shall be rounded to the nearest 10 cm and 5 cm or less shall be ignored)
Supply and fix in repairs down rod for ceiling fans 2 metre long GI pipe heavy grade, 15 mm dia complete including welding, painting as required complete all as specified and directed.
Supply and fix in repair iron hook/U clamp of suitable size and shape for ceiling fans as per site requirement including nuts bolts washers etc., complete all as specified and directed.
Supply only 40mm dia bore GI tubing light grade.
Fixing only in repairs GI tubing light grade of size 40 mm on wall for hanging of ceiling fan including taking down old one, civil works, cutting of GI tubing, provn of clamps, nuts & bolts, wshers and making good the disturbed surface complete all as specified and directed.
Material and labour for making of wall opening/hole in exsiting wall for fixing exhaust fan of size 300mm to 450 mm dia including making good the disturbed surface using cement mortar 1:4 to match with existing surface complete all as specified and directed.
Supply and fixing in repair Lamp holder, PVC/Polucarbonate type with plate suitable for batten fitting complete all as specified.
Supply and fixing in repair grouting bolts on wall with T head 10 mm dia 100 mm long (2 Nos) for fixing geyser of capacity 25/ 50 ltr all as specified and directed.
Preventive maintenance/servicing of storage type electric water heater (Geyser) of capacity 25 ltrs/ 50 ltrs for the task as mentioned in Appdx "A” of PS including taking down & replacement of all defective parts such thermostat, safety valves fusible, plug, heating elements, storage tank, insulating material, PRV dead wt valve etc., as and when required complete all as directed for any make. Note:- (i) All the spares replaced will be measured and paid separately as supply only. Cost of labour charge for taking down & replacing the unserviceable spares is deemed to be included in the quoted rate and no extra claim is entertained on this account. (ii) The mechanic/service person should attend all the break down calls immediately on priority for carrying out necessary maintenance/servicing/ replacement of the unserviceable spares as and when directed.
Supply only heating element 1.5 KW including rubber washers (Triangular base, ISI marked)
Supply only heating element 2.0 KW including rubber washers (Triangular base, ISI marked)
Supply only thermostat ISI marked suitable for the Geysers 25 ltrs capacity, 20 Amps, 240 Volts AC, fixed type, 300 mm long or nearest size, Set at 90+/-6 degreeC as per sample (ISI marked)
Supply only thermostat ISI marked suitable for the Geysers 50 ltrs capacity, 20 Amps, 240 Volts AC, fixed type, 300 mm long or nearest size, Set at 90+/-6 degreeC as per sample (ISI marked)
Supply only Geysers inner water tank made of copper suitable for 25ltrs capacity including checking of water tightness after fixing all as directed.
Supply only Geysers inner water tank made of copper suitable for 50ltrs capacity including checking of water tightness after fixing all as directed.
Supply only indicators for Geysers 25/ 50 ltrs capacity.
Supply & fix in repair 45cm long PVC reinforced connections pipe for cold water with brass hexagonal adapters both side suitable for 15mm dia pipe complete all as specified and directed.
Supply & fix in repair 60cm long PVC reinforced connections pipe for cold water with brass hexagonal adapters both side suitable for 15mm dia pipe complete all as specified and directed.
Supply & fix in repair 45cm long staineless steel flexible connections pipe for HOT water with brass hexagonal adapters both side suitable for 15mm dia pipe complete all as specified and directed.
Supply & fix in repair 60cm long staineless steel flexible connections pipe for HOT water with brass hexagonal adapters both side suitable for 15mm dia pipe complete all as specified and directed.
Supply and fix in repairs copper cable PVC insulated with 3 core 2.5 Sqmm with stranded conductor 1100V grade from socket/switch to geyser all as directed.
Supply and fix in repair Sheet metal enclosure single pole and neutral with two pin and earth plug and socket complete with one MCB SP 20 Amps and plug top complete all as specified and directed.
Supply and fix in repair 3 pin plug top, 16 amp capacity, 240 VAC, heavy duty, ISI marked all as directed.
Material and labour for servicing of air blast type electrically operated chimney installed in cook houses by dismantling complete filter assemblies / ducts and connected items for descaling with suitable chemical solution / caustic soda including reassembling, testing and painting with one or more coats of spray painting with synthetic enamel paint of approved brand and manufacture to give an even shade complete all as specified and directed.
Material and labour for dismantling unserviceable blower motor 3 phase 415 volts 1400 PRM 3 HP from existing pillar and transporting to civil work shop for repair/rewinding and reassembling the same on foundation and testing includes the followings:- (i) Opening/dismantling electric motor and removing burnt copper winding from starter and cleaning. (ii) M & L for rewinding starter with same gauge of super enameled copper winding wire including fixing of insulating papers, varnishing complete. (iii) S&F of ball bearings to match existing Nos. 2 (Make: SKF)
Supply and fix in repair MCB DB TPN 4 way double door sheet metal enclosure, 415 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) complete all as specified and as directed.
Supply and fix in repair MCB SPN 4 way double door sheet metal enclosure, 240 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) complete all as specified and as directed.
Supply and fix in repair MCB SPN 8 way double door sheet metal enclosure, 240 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) complete all as specified and as directed.
Supply and fix MCB triple pole and neutral 415 Volts, 63 Amps, 10 KA.
Supply and fix 'C' curve MCB single pole & neutral 240Volts 40 Amps.
Supply and fix 'C' curve MCB SP 240 volt 6 to 30 Amp
Supply and fix in repairs submain wiring with two runs of 6 sqmm single core FR PVC insulated unsheathed cable, 1100 volt grade, multistranded copper conductor cable including one run of 4 sqmm single core FR PVC insulated unsheathed cable, 1100 volt grade, multistranded copper conductor IS-694 marked drawn through heavy duty ISI Marked rigid PVC conduit with all accessories etc., including making good the disturbed surface complete all as specified and directed. Note:- Two runs of cable and one run of earth continuity conductor cable and one run of PVC conduit shall be measured as one unit length.
Supply and fix in repair environment friendly high efficiency with better thermal management type building security light 25Watt with integeral electronic driver connector block etc complete with all accessories internally prewired including neccessary mounting arrangement, provision of 2 core 1 Sqmm multistranded copper conductor from ceiling rose to fitting complete all as specified and directed. Make: Cat Part No ASTRA LSTS-25-CDL of crompton, Edqe Plus series 169826 BRLEP 25W LED WH of Bajaj, Endura city Lite platinum TGL LHETAXU7PA6S025 of Havells
Supply and fix in repair wall mounted LED 20W CRCA fitting 230 V with extruded aluminium heat sink provided for efficient heat dissipation and integeral electronic driver connector block etc complete with all accessories internally prewired including neccessary mounting arrangement , provision of new 3 core multistranded copper conductor of size 23/0.193 from ceiling rose to fitting including neccessary polycarbonate LED tube 4FT 20 W complete all as specified and directed. Make: TARA-M/20W of make C&S, LT8 20 865 2 FOR ROD & DML N1 LT8-16 for batten of Crompton, LHLDBXEUL7Z020 for rod & LMFYBWP1TB1W020 For batten of Havells
Material and labour for earthing complete with galvanized steel earth plate electrode 60cm x 60cm x 6mm thick buried directly in ground vertically (earth pit not less than 2.25 m deep below ground level) with top edge of the plate not less than 1.50 mtr deep below normal ground level, connecting to GI earth wire 4 mm dia by means of bolts, nuts, check nuts, and washers of galvanized iron or steel including 15 mm dia. light grade protection pipe for earth lead complete with charcoal and common salt in alternate layer including watering arrangement with galvanized iron pipe medium grade 20mm dia, PCC Chamber, CI frame and cover, MS funnel with wire mesh all as shown in electrical plate no 3 of SSR part I including excavation and earthwork in any type of soil/strata and testing on completion. Note :- GI earth wire 4 mm dia and 15 mm dia protection pipe upto 7.5 mtr from earth plate is deemed to be included in rate quoted.
Material and labour for point wiring using approved colour coding as per IS with 1.5 sqmm two single core PVC insulated but unsheathed FR cable, 1100 volts grade, ISI-694 marked with multistranded copper conductor and earth continuity wire with similar 1.5 sqmm cable (including connecting to earth dolly) drawn through ISI marked PVC Casing caping with all accessories etc with mild steel sunken box duly conceled in wall and having ISI marked hylem sheet suitable for piano type switch/Sockets/regulators for the following :-
One light/Fan point controlled byt oine no way switch
One three pin 5 Amps socket outlet point controlled by one No one way switch on same board.
One three pin 5 Amps socket outlet point controlled by one No one way switch on independent board.
One bell/buzzer point controlled by one bell push
All as per Item No 53 but point wiring with 2.5 sqmm single core copper cable and earth continuity wire with 2.5 sqmm single core cable for one three pin 15 Amp socket outlet point on independennt board.
Supply & fixing for switch piano flush type single pole one way, and 6 amp complete ISI mark
Supply & fixing for Socket outlet multipurpose having provision for 2 in 1, 3 oin 5 Amp piano flush type complete all as specified.
Supply & fixing for Switch piano flush type single pole one way, and 15 amp complete ISI marked.
Supply & fixing for socket outlet 2 in 1, 2/3 Pin 5 Amps and 15 Amps flush type .
Supply & fixing for stepped type electronic fan regulator socket type on the existing phenolic laminated sheet, etc as required.
Paragon Electrotechnics
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .