Loading…
Loading…
| # | Company | Status |
|---|---|---|
| 1 | Not Admitted-Finance | Not Admitted-Finance Not qualified for AOC |
| 2 | Not Admitted-Finance | Not Admitted-Finance Not qualified for AOC |
| 3 | Not Admitted-Finance | Not Admitted-Finance Not qualified for AOC |
Tender Value
Refer Docs
EMD Value
₹30.4 L
Closing Date
6 Oct 2025, 12:00 pmClosed
EE(UD)-cum-Member Secy.
O/o the EE(UD)-cum-Member Secy., DUDA, Jairampur
Design, Build, Construct and Commission of Sewage Treatment Plant (STP) along with Co-treatment of Faecal sludge-septage with 5 years of Operation and Maintenance in Jairampur towns of Arunachal Pradesh
2025_APUDH_2778_1
EE/UD/JRP/PLG/01/2025-26
Open Tender
Solid Waste Management
Turn-key
730 days
Jairampur
Please refer Tender documents.
4 documents required · 4 mandatory
₹10,000
DC-cum-Chairman, DUDA, Jairampur
₹30.4 L
DUDA, Jairampur
6 Nov 2025
22 Sept 2025
6 Oct 2025
22 Sept 2025
6 Oct 2025
22 Sept 2025
30 Sept 2025
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Construction of RCC elevated Platform for screen channel and Grit Chamber | - | - | - | - |
| 2 | Earth work in excavation in foundation and trenches etc. in all kinds of soil (excluding soil containing 50% or more of shingle or small size boulders upto 30 cm size, saturated soil and rock) lift upto 1.50m and stacking the excavated soil not more than 3m clear from the edge of the excavation and returning the stacked soil in 15 cm layers, when required into plinth sides of foundation etc. consolidating each deposited layer by arming and watering of all surplus soil as directed within a lead of 50m in all types of soils for footings | - | Cum | - | - |
| 3 | Earth work in excavation in foundation and trenches etc. in all kinds of soil (excluding soil containing 50% or more of shingle or small size boulders upto 30 cm size, saturated soil and rock) lift upto 1.50m and stacking the excavated soil not more than 3m clear from the edge of the excavation and returning the stacked soil in 15 cm layers, when required into plinth sides of foundation etc. consolidating each deposited layer by arming and watering of all surplus soil as directed within a lead of 50m 10% of the Total Qty | - | Cum | - | - |
| 4 | Filling with sand including watering, ramming, consolidating and dressing complete.Below CC bed Below CC bed | - | Cum | - | - |
| 5 | Providing and laying in foundations and plinth cement concrete 1 : 4 : 8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size) excluding the cost of centring and shuttering.CC Bed | - | Cum | - | - |
| 6 | Reinforced concrete work in foundations, footings, bases of columns etc. and mass concrete excluding cost of centring, shuttering and reinforcement in :
a) M20 (1 cement : 1.5 coarse sand : 3 stone aggregate 20 mm nominal size).Footings | - | Cum | - | - |
| 7 | Reinforced concrete work in foundations, footings, bases of columns etc. and mass concrete excluding cost of centring, shuttering and reinforcement in :
a) M20 (1 cement : 1.5 coarse sand : 3 stone aggregate 20 mm nominal size).Pedastal | - | Cum | - | - |
| 8 | Reinforcement cement concrete work in columns, pillars, piers, abutments, post and struts etc up to floor two level including finishing and plastering the exposed surface with cement mortar 1 : 3 (1 cement : 3 fine sand) of thickness not exceeding 6 mm to give a smooth and even surface but exluding cost of centring, shuttering and reinforcement.
a) M20 (1 cement : 1.5 coarse sand : 3 stone aggregate 20 mm nominal size).Columns upto GLColumns Above GL | - | Cum | - | - |
| 9 | Reinforced cement concrete work in lintels, beams and bresumers up to floor two level including finishing and plastering the exposed surface with cement mortar 1 : 3 (1cement : 3 fine sand) of thickness not exceeding 6 mm to give a smooth and even surface but excluding cost of centering, shuttering and reinforcement.
a) M20 (1 cement : 1.5 coarse sand : 3 stone aggregate 20 mm nominal size).Plinth BeamBracing Tie Beam @ 4m heightRoof Beam | - | Cum | - | - |
| 10 | Reinforced cement concrete in suspended floors, roofs, landings and balconies upto floor two level including finishing and plastering the exposed surface with cement mortar 1 : 3 (1 cement : 3 fine sand) of thickness not exceeding 6 mm to give a smooth and even surface but excluding cost of centring and shuttering and reinforcement with M20 (1 cement : 1.5 coarse sand : 3 stone aggregate 20 mm nominal size).Roof Slab | - | Cum | - | - |
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.48 MB
BOQ_2966.xls
BOQ • 0.47 MB
RFP.pdf
Tender Documents • 6.45 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .