Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹11.9 LAccepted-AOC 3 N K CHATTERJEE STREET KOLKATA 700 056 | KOLKATA | KOLKATA | WEST BENGAL | 700056 | L1 | Accepted-AOC AOC | |
| 2 | L2₹12.3 L+₹47,130 (3.97%)Rejected-Finance 13 SRIMANTA DEY LANE KOLKATA 700012 | KOLKATA | KOLKATA | WEST BENGAL | 700012 | L2 | Rejected-Finance Bid is not L1 | |
| 3 | L3₹12.7 L+₹78,604 (6.62%)Rejected-Finance 104 RASHTRAGURU AVENUE DUM DUM NAGERBAZAR KOLKATA 700028 | KOLKATA | HOOGHLY | WEST BENGAL | 700028 | L3 | Rejected-Finance Bid is not L1 |
Tender Value
Refer Docs
EMD Value
₹24,000
Closing Date
9 Sept 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Executive Engineer PWD Howrah Electrical Division
Office of the Executive Engineer PWD Howrah Electrical Division Onkarmal Jetia Road Howrah 711103
Repairing and Renovation of Electrical Installation works including mortuary cooler for keeping unclaimed body and still baby at District Hospital, Howrah.
2022_WBPWD_394157_1
WBPWD/EE/HED/NIQ-19 of 2022-2023
Open Tender
MISC ELECTRICAL WORKS
Item Rate
30 days
District Hospital Howrah
Please refer Tender documents.
9 documents required · 9 mandatory
₹24,000
Office of the Executive Engineer PWD Howrah Electr
29 Dec 2022
8 Aug 2022
12 Sept 2022
9 Aug 2022
9 Sept 2022
20 Aug 2022
18 Aug 2022
Amount
Electrical Installation Work
SUB-HEAD 1--DISTRIBUTION WIRING
Distribution wiring in 2 x 22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire (FINOLEX/POLYCAB/ RR KABLE) in 20mm size PVC rigid conduit 'FR' (Precision make), with 1x22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire for ECC, to light/fan/call bell points with Piano Key type switch fixed on MS CRC sheet metal (16 SWG) switch board cum JB on wall complete with 2 no. suitable size “Ph & N” copper bar incl. bakelite/Perspex (wall matching color) top cover 3mm thick and incl. 175mmx100mm x65mm inspection box,making earthing attachment, painting the MS box and mending good the damages to original finish. Avg. Run - 8 Mtr. [2 (c) / E- 14 ]
Distribution wiring in 1.1 KV grade 22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire (FINOLEX/POLYCAB/ RR KABLE) in 20mm size PVC rigid conduit 'FR'(Precision make), with 1.1 KV grade 1 x 22/0.3 (1.5 sqmm)single core stranded 'FR' PVC insulated & unsheathed copper wire as ECC, to 5A 3 pin flush type plug socket & Piano Key type switch fixed on MS CRC sheet metal (16 SWG) switch board cum JB on wall incl. bakelite/ Perspex (wall matching color) top cover 3 mm thick and incl. painting the MS box and mending good the damages to original finish[ As per approved list of Material ][ 4 (a) / E- 15 ] On board
Supplying and Drawing 1.1 KV single core stranded 'FR' PVC insulated & unsheathed single core stranded copper wire of the following sizes in the prelaid polythene pipe as per GS.(FINOLEX/POLYCAB/ RR KABLE)
2x(2.5sqmm)+1x(1.5 sqmm) [FOR 2 nos POWER BOARD]
2x (6 sqmm) + 1x (4 sqmm) [FOR SPNDB]
4x (4 sqmm) + 2x (2.5 sqmm) [FOR Mortuary cooler]
Supplying and fixing PVC Rigid Conduit 'FR' [Precision Make]on wall, ceiling with saddles and other accessories as required and mending good damages to building works
20mm size[E-16/7(a)]
SUB-HEAD 2--SPNMCBDB.
Supplying and fixing double-door SPN MCB Distribution Board with IP-42/43 protection, concealed in wall after cutting the wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment. 2+8 Way ( Make - Legrand/L&T/ABB ELEGANCE ) [ 13 / D- 9 ]
Supplying and fixing 240/415 V MCB Isolator on din rail of existing DBs and necessary connection as perGS ( Make - Legrand/L&T/ABB) 40A DP. [ 6 / D- 5 ]
Supplying and fixing 240/415 V MCB of Breaking capacity 10kA & C characteristics on din rail of existing DBs and necessary connectionas per GS ( Make - Legrand/L&T/ABB) 6-32 A SP [ 7 / D- 6]
SUB-HEAD 3-- SUPPLY & LAYING OF CABLES
Supply & Laying of one No. 1.1 KV Gr. XLPE/ PVC Armoured Al Cable of following size in underground trench 460 mm wide x 760 mm average depth, with brick protection on the top of the cable with 8 (eight) Nos. bricks per metre, including filling the space between the brick & cable and also the trench with shifted soil, leveling up and restoring surface duly rammed ( Make- Gloster/POLYCAB/ RR KABLE) [F-2/1(a)] 4 core 16 sq.mm
Supply & Laying of 1.1 KV Gr. XLPE/ PVC Armoured Al Cable of different sizes on wall/surface including S & F MS clams with earthing attachment in 2 x 10 SWG GI (Hot Dip) Wire, making hole etc. As necy., mending good damages and painting.( Make- Gloster/POLYCAB/ RR KABLE) [F-1/2(c)]
4 core 16 sq.mm
3 core 6 sq.mm
Supplying and fixing compression type gland complete with brass gland, brass ring & rubber ring for dust & moisture-proof entry of XLPE/PVC armoured cables as below.[F-4/7(c)]
4 core 16 sq.mm
3 core 6 sq.mm
Finishing the end of following XLPE/PVC armoured cables by crimping method incl. supplying and fixing solderless socket (Dowels make), tapes, anticorrosive paste & jointing materials[F-5/8(b)]
4 core 16 sq.mm
3 core 6 sq.mm
SUB-HEAD 4 - SUPPLY & FIXING OF LED LIGHT FITTINGS
Supply & Fixing Double LED tube light fittings with 2 nos 20 watt LED tube llight suspended 25 cm below the ceiling with 2 No. 20 mm dia EI conduit (14 SWG) supports fixed with “L” type MS clamp whose one side fixed on ceiling with sutable size 4 nos. fastener and other side connected with the conduit with suitable size of bolts and nuts incl. S&F EI conduit, “L” type (125mmx125mm) 6mm thick and 25mm with MS clamps and connecting the length of PVC insulated wire and mending good damages to original finish and painting etc. by 2x24/0.20 mm (1.5sqmm.) flexible copper wire of 1.10 mt. length.[Make: Signify -TMC 501 2XT-LED, Tube-MASLED TUBE 1200MM 18W865T81- 2100 lm / WIPRO: WIO14 2208 / Crompton: IGP 162 LT8-16, 18/20 watt LED tube]
Supply & Fixing single LED tube light fittings with 1 no 20 watt LED tube llight suspended 25 cm below the ceiling with 2 No. 20 mm dia EI conduit (14 SWG) supports fixed with “L” type MS clamp whose one side fixed on ceiling with suitable size 4 nos. fastener and other side connected with the conduit with suitable size of bolts and nuts incl. S&F EI conduit, “L” type (125mmx125mm) 6mm thick and 25mm with MS clamps and connecting the length of PVC insulated wire and mending good damages to original finish and painting etc. by 1.5 sqmm flexible copper wire of 1.10 mt. length. [Make: Signify -TMC 501 1XT-LED, Tube-MASLED TUBE 1200MM 18W865T81- 2100 lm / WIPRO: WIO14 1208 / Crompton: IGP 161 LT8-16, 18/20 watt LED tube]
Extra for suspension exceeding 25 cm with S&F additional 2 no. 20 mm dia EI conduit (14 SWG) supports & necy. PVC insulated wire and painting etc. as required by 2x24/0.20 mm (1.5sqmm.) flexible copper wire of 1.10 mt. length.[16/C-2 ]
Supply &Fixing of 9 W LED Lamp (Make:Philips Ace Saver) on existing angular batten holder (Anchor) on 75mm dia PVC round block / round bakelite on wall/ceiling.) (22/D-13)
Supply & Fixing of 220-240V 90W LED outdoor type street light fittings complete with all accessories (Make: Crompton--- Cat No. CRP-404-90-57-SL-GL-NSG, NEXUS NEO/Signify/Wipro) to be fixed/projected from the wall of the building incl. making holes to building, S&F 40 mm dia GI pipe (ISI-Medium) 1.50 mts. average length, with GI socket at one end and thread at the other end & suitable bend to house the fitting & making necy. connections with S&F necy. length of 1.5 sqmm PVC insulated single core stranded annealed copper wire and making connections as required and mending good damages to wall and painting
S&F 25cm X 25 Cm X 16 cm Sintex mk. single hinged SMC GSJB Material- FRP , Plastics, Cable entry from bottom and/or sides, Shockproof and rustproof and Rotproof and termite resistant, on wall/Pole with necessary accessories , connector & fuse as per direction of E.I.C.
Supply & providing CC (6:3:1)base block (around the pole) dimension .45x0.45x0.60mt. above ground level, neatly cemented finish (3 mm thick), at the base pole (in lieu of CC muffing) incl.drilled hole in pole suitable for alkathene/polythene pipe entry, for street light wiring, without Loop Box.[H-1/3b,(ii)]
S&L inside Pole 3 x 1.5 Sqmm copper wire through 13 mm heavy gauge polythine pipe from loop box to light fittings with making neccesary. Connection.
SUB-HEAD 5 -- SUPPLY & FIXING OF FANS
Supplying & Fixing following AC ceiling fan (Make: Orient Energy star / Crompton HS+ or HB+/ USHA Striker) complete with blades, canopy, fork, rubber bush etc. incl. S&F connecting wire for down rod upto 30 cm incl. painting the rod with approved paint and making necessary connection as required by 2x1.5 sqmm flexible copper wire. 48''(1200 mm) sweep [C3/21a].
Supply & fixing Electronic Socket type fan regulator on existing sheet metal switch board with backelight/ perpex top cover by serew after making housing for regulator knob by cutting backelight/ perpex top cover including making necessary connections. [Make: Anchor] [18(a)/E-6]
Supplying & Fixing MS fan clam of two piece type for RC ceiling as per approved specification, fabricated from 40 mm x 9 mm MS flat including making good damages to building roof with satisfactory finishing and painting – (As per Drawing no. 475 of PWD Specification Book – May 1991)[D14/29]
Supply & Fixing of Heavy Duty Exhaust fans after making hole in wall and making good damages and smooth cement finish etc. as practicable as possible and providing necy. length of PVC insulated wire and making connection for exhaust of following diameter:complete with all accessories having the following Model / Cat No.( Make -EPC Electrical Pvt Ltd ). 30 cm (12")(Speed : 1420 rpm).
Supply & Fixing GI sheet (20SWG) metal Cowl with MS flat iron frame & GI wire mesh on wall with necy. bolts & nuts (6 mm dia x 62 mm long)30 cm (12") [ 33)/D-14 ]
SUB-HEAD 6-- PLUGS & SOCKETS
Supply & Fixing 240 V, 20A, plug socket with separate 20 A Piano key type switch (Brand approved by EIC) on sheet metal switch board embedded in wall incl. S & F 150x100x 65mm MS (16SWG) switch board and bakelite/perspex top cover of 3mm thick by Brass screws aftermaking housing for switch by cutting bakelite/perspex cover and making necessary connections as required[E-6/22].
SUB-HEAD 7 -- MAIN SWITCH
Supplying and fixing 415V, 63 A TPN SFU with sheet steel enclosure on angle iron frame on wall/LT panel with nuts bolts etc incl. S & F 3 nos. DIN type HRC fuse as per rating. Make- L & T /Havells/ABB. [D-3/4(a)]
SUB-HEAD 8 --MISCELLANEOUS
Supplying & fixing 50 mm dia medium gauge GI Pipe ( ISI-Medium) Protection with necessary fittings and jointing metarials as required. [F-6/11(d)]
Cutting channel on C.C. Floor 100 mm X 100 mm depth with drilling arrangement system by compressor machine on the top of the pheriphari surroundingly and Supply & filling the cutting portion of the same floor by cement mortar mixture & neatly cement finising and properly curing of water as per direction of E.I.C.
Supply and Installation of recetangular type Poly Vinyle glow sign board of size 6' X 4' X 10" at main gate . Description is given below :- Charges for making of metal housing fabricated structure made by 25 X 25 X 6 mm thick M.S. Angle and 25 mm X 6 mm thick flat from main structure suitable for rectangular type glow sign board, welded point to point, fixing the back portion covering the 22 SWG G.I. sheet providing with 2 rod back stay made of 25 X 25 X 6 mm angle for grouting the same on piller to keet it rigidly. The structure will be grouting at piller of gate by cement and sand. The complite sets to be painted by 2 coats of synthetic enamel paints over 2 coats of R.O Primer. S& F 2 mm thick imported quality polycarbon sheet vinyle pasted facia size 13' X 3 ' letters will be pasted on the facia by imported quality masting materials after cutting and shaping the all illuminated letters.S&F of 40 X 40 mm and 24 SWG thick G.I. Angle with necy. Screws, nuts,washers on the sorrounding corner of the board(front Side) to keep it rigidly. Supplying and fixing of 4 ft long 20 watt LED light fittings 5 nos. main line connection made by 2.5 Sq.mm. Single core copper wire. ( Make - Signify/Crompton/Wipro)
SUB-HEAD 9 -- EARTHING
Earthing with 50 mm dia GI pipe 3.64 mm thick x 3.04 Mts. long and 1 x 4 SWG GI (Hot Dip) wire (4 Mts. long), 13 mm dia x 80 mm long GI bolts, double nuts, double washers incl. S & F 15 mm dia GI pipe protection (1 Mts. long) to be filled with bitumen partly under the ground level and partly above ground level driven to an average depth of 3.65 Mts. below the ground level as below: ( By ISI-Medium GI pipe) G1-2(a)
Excavation of soil for installation of Earth Electrode and filling & ramming. (G1-1a) For soft Soil
Supplying & fixing earth busbar of galvanized (Hot Dip) MS flat 25 mm x 6 mm on wall having clearance of 6 mm from wall including providing drilled holes on the busbar complete with GI bolts, nuts, washers, spacing insulators etc. as required.(G2-4a)
Connecting the equipments to earth busbar including S & F 7/14 SWG GI Standard (Hot Dip) wire of size as below on wall/floor with staples buried inside wall/floor as required and making connection to equipments with bolts, nuts, washers, cable lugs etc. as required and mending good damages.(G2-5bi)
S.I.T.C. of 1 no. 2 X 4 body mortuary cooler.
Supply & Installation of 08 body mortuary chamber (Dimension-- L- 10'-6"ft x D-9'-6"ft x H-5-0’ft) costructed with well seasoned & treated wooden frame work, GI mesh wire net, anti-rat protection, 4mm. thick standard size glass tiles layer and 100mm thick thermocol insulative board on walls, ceiling & floor including finishing with cement plastering & suitable painting. Floor will be finished by 50mm thick cement concert casting including neat cement finish after thermal insulation. "U" Shaped drainage arrangement by glaze tiles including S & F siphon system drainage pipe will be in side walls.
Supply & Installation of 415V. 3Ph 50Hz 5 TR Capacity Air Cooled Condensing unit (1W+1S) with R-22 refrigerant complete with Sealed Unit compressor, heavy duty Copper Condenser coil, Blower Motor (18" Crompton Greaves), Receiver, Accumulator, Condenser Fan Motor, Service Valve, and LP/HP cut out Switch, Condenser Housing and Complete Angle Iron Unit base with brick foundation for both Stand by unit as well as working unit (for the 1 no. 2 x 4 Body Mortuary cooler)
Supply & Installation of 5 Ton Capacity low temperature cooling coil (Desired Temperature :- 40 ⁰F ± 2 ⁰F) made by heavy duty 5/8 " dia copper pipe with distributor, angle Iron frame with blower motor & base, fan blade and Vibration shock absorption rubber base complete set.
Supply & fixing new mortuary doors (Size 4" x 4" & 4" x 5") for the 8 body mortuary made of well seasoned & treated Sal wood including adequate 4" thick inner outer insulation against heat leakage, covering with 24 SWG Aluminum sheet & finished with paint, complete with door gasket, thickly chromium plated brass hinges, latches & locking arrangement fixed on the wooden frame work of mortuary chamber.
Supply & fixing new cooling coil inspection doors with wooden frame (Size 4" x 4" & 4" x 5") at the back of the cooling coil made of well seasoned & treated Sal wood including adequate 4" thick inner outer insulation against heat leakage, covering with 24 SWG Aluminum sheet & finished with paint, complete with door gasket, thickly chromium plated brass hinges, latches & locking arrangement fixed on the wooden frame work of mortuary chamber.
Construction of cooling coil base by bricks, sand and cement with required necessary masonry work inside the cooling chamber including insulation of the same by 4" thermocol, wire mesh net, "U" hocks with plaster finish and neat cement at the top of the base to accommodate 2 no's cooling coil for each chamber.
Supply & Installation Complete arrangement of 4 track-2 tire self type structure of welded 3” x 3” x 3/8 “ angle iron with necessary cross sectional joint for accomodating the mortuary trays would be insulated inside of the morgue as per drawings. The structure will have two coats of red oxide and two coats of grey enameled paint.
Supply & Charging R –22 refrigerent Gas.
Supply & fixing of Mortuary tray each having dimensions 24"x72" long & fabricated by 20 SWG SS Sheet & placed on requisite angle iron frame on (40mm x 40mm x 6mm) complete. With 4 Wheels MS pin and Handel including sliding arrangement on the frame for pulling the trays on wheels.
S & drawing refrigerant pipe lines for suction line, Discharge line, Condenser to receiver pipe line of with suitable sizes copper pipe including S& Fixing Thermostat Switch, Expansion Valve, Solenoid Valve, Hand Shutoff Valve, Drier, Dial type Thermometer, necessary brass flayer nut, suction line insulation complete in all respect as per direction of E.I.C
Cost of Thorough testing of the complete Installation of the Plant including High pressure dry Nitrogen gas pressure testing 48 hrs, with thorough system vacuum testing 48hrs,with testing the plant proper maintaining desired temperature.
Supply & Installation of wall mounting cubicle type 450 Volt, 50 Hz. electrical control panel fabricated from 40 x 40 x 5 mm MS angle and 40 x 5 mm MS flat & painting with 2 coats of Synthetic Enamel paint over 1 coat of RO primer & earthing attachment comprising with following electrical accessories & interconnection with suitable copper wire including wiring in between panel board to condensing unit & cooling unit motor with inter locking connection by suitable size of copper wire from condensing unit to control panel through PVC rigid pipe incl. proper earthing arrangement. INCOMER: 440V, 63 amps TPN MCB (Make- L&T/Legrand/ABB)- 1 no OUTGOING: 440 V, 32 A TPN MCB (Make- L&T/Legrand/ABB) - 2nos, 220V, 16 A DPMCB ( Make- L&T/Legrand/ABB) - 2 Nos. BUSBAR: 100 Amp capacity 99.9% - 99.5% electrolytic tinned copper 4 bar bus bar [size of flat 4 x 20 mm x 3 mm] mounted on non-hygroscopic porcelain insulator / hylam sheet having sufficient di-electric strength duly wrapped with colour PVC tapes (Red, yellow, blue & black) for phases & neutral identification & all connection made with required size cu bars - 1set.
CONTROLLING: 440 V, DOL Starters with over load relay (relay rang 9-14 amps), ( Make-LT/LK MUG-10) -2 nos METERING: 250 V, 10 A SPMCB 3 NOS, Voltmeter, Ammeter & 3 NOS CT coils of suitable specification & brand . INDICATORS: 3 nos LED R, Y, B indicators (Siemens) with 3 nos 250V, 6A SPMCB SAFETY: Single Phase Preventer & EI Danger board 1 no.
Charges for minor civil work as required to finish the job such as cutting of wall, making hole in wall and finishing the same by C.C mortar (4:2:1), plastering etc as per direction of EIC.
Terms & Conditions for Mortuary Cooler.
The agency must procure the matrials from the manufacturer / OEM or from their authorised sales channel so that the standard warrenty/ support of the manufacturer / OEM becomes applicable to the products to be delivered and installed by them.
Documents that authanticates such procurement from the manufacturer / OEM of from their authorized sales channel and standard warrenty/ support should be sent from e-mail of the manufacturer / OEM / authorised sales channel to the e-mail or E.I.C. And hard copy of it to be submitted during execution of work/submission of bill.
If any refurbished materials is supplied and installed penel action will be taken as per existing rules.
Defect Liability period 1 (One) year.
Rate should be quoted including all Taxes & L.W.C (if any).
NATIONAL ENGINEERING INDUSTRIES
SNOWLINE ENGINEERS
technical_772955.pdf
PDF • 0.08 MB
techsummary_772955.pdf
PDF • 0.09 MB
finance_772955.pdf
PDF • 0.04 MB
BOQ Comparative Chart
xlsx • 0.02 MB
finsummary_772955.pdf
PDF • 0.09 MB
AOC.pdf
PDF • 0.16 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .