Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹16.2 LAccepted-AOC 15 CP COLONY MORAR GWALIOR MP 474 006 | GWALIOR | GWALIOR | MADHYA PRADESH | 474006 | 1 | Accepted-AOC BEING LOWEST | |
| 2 | 2₹21.6 L+₹4.8 L (28.9%)Rejected-Finance C 187 NIRMAN VIHAR DELHI 92 | 2 | Rejected-Finance being not lowest | |
| 3 | 3₹21.8 L+₹5.1 L (30.2%)Rejected-Finance SAI LEELA MAHAVIR COLONY BIRLA HOUSE GOLA KA MANDIR MORAR GWALIOR 474005 | GWALIOR | GWALIOR | MADHYA PRADESH | 474005 | 3 | Rejected-Finance being not lowest | |
| 4 | 4₹22.4 L+₹5.7 L (33.8%)Rejected-Finance 42 INDUSTRIAL ESTATE GWALIOR MP 474004 | GWALIOR | GWALIOR | MP | 474004 | 4 | Rejected-Finance being not lowest | |
| 5 | 5₹22.7 L+₹6.0 L (35.8%)Rejected-Finance 24 824 GOVERDHAN COLONY MAIN BHIND ROAD GOLE KA MANDIR | 5 | Rejected-Finance being not lowest |
Tender Value
₹30 L
EMD Value
₹60,000
Closing Date
31 Aug 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
CWE (AF) GWALIOR
CWE (AF) GWALIOR
REPAIR MAINT REPLACEMENT OF UG (11KV) CABLE, JOINTS AND CONNECTED WORKS AT AF STATION GWALIOR
2022_MES_543005_1
85033
Open Tender
Electrical and Maintenance Works
Item Rate
365 days
GWALIOR
Please refer Tender documents.
9 documents required · 9 mandatory
₹500
GE ADM AREA GWALIOR
₹60,000
Yes
17 Sept 2022
3 Aug 2022
5 Sept 2022
3 Aug 2022
31 Aug 2022
17 Aug 2022
Amount
Excavation in trenches in soft & loose soil not exceeding 1.5 metre deep and not exceeding 1.5 mtr in width and getting out soil including forming bottom surface to required slope/gradient for laying cables/pipes etc. all as specified and directed by Engineer-in-Charge including removing cable protection PCC covers any type/ bricks & stacking serviceable covers / bricks for reuse and disposal of unserviceable covers within 50 m all as directed. Note : Excavation shall be made carefully in order to avoid damage of existing cables and protection of covers.
Returning, filling in including spreading, leveling, watering and well ramming in layers of n. exc. 25 cm thick after the cables etc. are laid, jointed & tested complete all as specified and directed by Engineer-in-Charge.
Removal of surplus excavated spoil not exceeding 50 mtr distance and depositing where directed by Engineer-in-Charge at a level not exceeding 1.5 m above the starting point complete all as specified and directed by Engineer-in-Charge.
Material & labour for sand filling with clean dry fine sand unwashed including gently punning around cables in trenches for cable protection complete all as specified and directed by Engineer-in-Charge. NOTE:- For measurement purpose punned thickness shall be considered as per clause 19.75 of SSR Part-I.
Supplying & Laying un-reinforced factory made, pre-cast flat concrete cable protection cover of class HV, type I, size 300mm x 180mm x 40mm, complete all as specified and directed by Engineer-in-Charge.
Fixing / laying only old retrieved cable protection cover of any description as obtained from dismantling of the cable complete all as specified and directed by Engineer-in-Charge.
Disconnecting, taking out and removing old existing unserviceable underground HT 11 kV cable of any description and in any position complete all as specified and directed by the Engineer-in-Charge for the following sizes:
95 Sqmm to 120 Sqmm, 3 core
150 Sqmm to 240 Sqmm, 3 core
Laying, jointing and testing 11kV HT underground cable of any description and any make laid in trenches/ducts, floors, fixed to walls etc. complete all as specified and directed by the Engineer-in-charge for the following sizes :-.
95 Sqmm to 120 Sqmm, 3 core
150 Sqmm to 240 Sqmm, 3 core
Supply, laying , jointing & testing 11 kV (Earthed) XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electirc power cable (heavy duty) with aluminium conductor, 11000 Volts (Earthed) conforming to IS 7098 (Part-II) 1985 amended upto date having following cross sectional area complete all as specified and directed.
95 Sqmm, 3 core
120 sqmm, 3 core
185 sqmm, 3 core
240 sqmm, 3 core
Excavation for removing/checking of HT cable joint with draining out water in trenches including returning filling of existing soil, sand, PCC cable cover and making good disturbed surface complete all as specified and directed by Engineer-in-Charge.
Material and Labour for Cable jointing kit for 11 kV (Earthed grade) for Straight through heat shrink type joint with end termination joint suitable for following sizes complete material & labour including cutting the faulty straight through of any type and in any position including jointing, testing and taking down of existing Straight through heat shrinkable type end termination joint complete all as specified and directed. Note :-(i) All Necessary T&P, Blow lamp, HT Megar, etc. if required shall be arranged by the Contractor. (ii) The contractor has to rectify the joints within 4 Hrs after detecting of the faults, in case of failure the penalty of Rs 1000.00 per hours shall be recovered from contractor dues.
50 Sqmm to 95 Sqmm, 3 core
120 Sqmm to 185 Sqmm 3 core
240 Sqmm to 300 Sqmm 3 core
Material and Labour for cable jointing kit for 11 kV, (Earthed grade) indoor type heat shrink end termination joint suitable for following sizes complete material and labour including cutting the faulty indoor end termination joint of any type and in any position including jointing, testing and taking down of existing indoor type heat shrinkable end termination joint complete all as specified and directed. Note :-(i) All Necessary T&P, Blow lamp, HT Megar, etc. if required shall be arranged by the Contractor. (ii) The contractor has to rectify the joints within 4 Hrs after detecting of the faults, in case of failure the penalty of Rs 1000.00 per hours shall be recovered from contractor dues.
50 Sqmm to 95 Sqmm, 3 core
120 Sqmm to 185 Sqmm 3 core
240 Sqmm to 300 Sqmm 3 core
Material and Labour for cable jointing kit for 11 kV (Earthed grade) outdoor type heat shrink end termination joint suitable for following sizes complete material and labour including cutting the faulty outdoor end termination joint of any type and in any position including jointing , testing and taking down of existing outdoor type heat shrinkable end termination joint complete all as specified and directed. Note :-(i) All Necessary T&P, Blow lamp, HT Megar, etc. if required shall be arranged by the Contractor. (ii) The contractor has to rectify the joints within 4 Hrs after detecting of the faults, in case of failure the penalty of Rs 1000.00 per hours shall be recovered from contractor dues.
50 Sqmm to 95 Sqmm, 3 core
120 Sqmm to 185 Sqmm 3 core
240 Sqmm to 300 Sqmm 3 core
Demolition for cement concrete/road in ground floor and paving not exceeding 15 cm thickness below or above ground level including removal of rubbish to a distance exceeding 1.50 km and not exceeding 5.00 km etc complete all as specified and directed.
Material and Labour for Plain Cement concrete 1:3:6 , type C-1 (using 20 mm graded crushed stone aggregate) as in foundations and mass concrete including necessary filling complete all as specified and directed.
Material and Labour for Boring of hole under road, pavement, hard-standing by trenchless technology using ultrasound technique and necessary machine with & including HDPE pipe of 150 mm dia sutable for 0.4 mpa working pressure complete all as specified and directed by Engineer-in-Charge. Note : Pipes shall be laid minimum 1.00 mtr below/under existing road surfaces/taxi track / apron /floors etc.
Material and Labour for laying & jointing 80 mm bore GI water tubing, light grade as in sleeving etc laid in trenches / ducts / horizontal bore hole including replacement/taking down of existing GI water tubing complete all as specified and directed.
Material and Labour for laying & jointing 100 mm bore GI water tubing, light grade as in sleeving etc laid in trenches / ducts / horizontal bore hole including replacement/taking down of existing GI water tubing complete all as specified and directed.
Material and labour for checking and finding out pin point location of fault in HT 11 KV underground cable with the help of fault locating High Tech mobile machine complete all as directed. Note : (i) Charges for rent and transportation of the fault locating high tech mobile machine including DG Set, necessary earth work for repair HT cable, testing of cable after repair, charges for operator, engineer, electricians etc deemed to be included in the quoted rate. (ii) Fault locating high tech mobile machine will be provided as and when required on short notice otherwise an amount of Rs. 5000.00 per day will be charged as panelty. (iii) The quoted rate deemed to have been included irrespective of number of faults in a stretch of 500 Rm and no extra payment will be made for any number of faults with in the paricular stretch. (iv) No payment will be made for the 500 Rm stretch , if no fault is detected in that stretch.
Supply, installation, testing and commissioning of factory fabricated CPRI approved outdoor Kiosk type HV junction panel of size ((L) 1.80M X (W) 0.90M X (H) 1.80M ) for 3 phase, 11 KV, AC, 50 Hz supply & aluminium bus bar of 600 amp rating , cubical of appropriate size made of 3.00 mm thick CRCA steel sheet and angle iron base & legs 25mm x25mm x 5mm totally enclosed with top canopy, free standing, water, dust & vermin proof with IP 65 protection powder coated internally and externally not less than 80 micron thick after seven tank pre-treatment process including locking arrangement and embeding angle iron legs in PCC (1:3:6) type C-1 precast blocks of size 20X20X45 cm deep all as specified & directed.
Material and labour for earthing complete with galvanized steel earth plate electrode 600mm x 600mm x 6mm buried directly in ground vertically to a depth not less than 2.25 metre below normal ground level (with top edge of earth plate not less than 1.5 metre below ground level) connected to galvanized iron earth strip 32mm x 6 mm (main earthing lead) by means of galvanized bolts, nuts and washers all as shown in electrical plate No 3 of MES Schedule Part-I (2009) connected to earth test point & to main switch board with & including adequate quantity of charcoal dust and common salt alround earth plate & 40 mm dia GI pipe medium grade for earth lead protection pipe for suitable length and GI pipe 20 mm dia medium grade for watering pipe with funnel & wire mesh including necessary earth work and PCC (1: 3 : 6), type C-1 (using 20 mm graded crushed stone aggregate) for earth pit , internal surface of concrete shall be given 10mm thick plaster in CM 1:4 and 40 mm thick pre-cast RCC cover 1 : 2 : 4 ,type B-1( using 20 mm graded crushed stone aggregare ) reinforced with 8 mm dia TMT bars @ 75 mm c/c both ways with 12mm dia round bar as in handle including taking down of existing earthing complete all as specified & directed by Engineer-in-Charge. Note: (i) Test result of earthing to be submitted by the contractor for all earthing. (ii) Earth filling shall be done by soil as approved by GE. (iii) Soil should be free from stone, boulders, aggragates, gravel, etc. (iv) The rate quoted by the bidders shall also be deemed to include :- (a) Excavation upto 5 mtr depth and returning filling in any type of soil and disposal of surplus soil. (b) Supply of charcoal and common salt.
Supply and laying the hard core broken stone/ boulders of gauge not exceeding 63 mm, deposited, spread and levelled in layers not exceeding 15 cm thick, to a true surface at the places as specified and directed by Engineer-in-charge.
M/S KAPIL CONSTRUCTION CO
M/s Gulshan and Brothers
M/s Mahesh Engineering Works
anand enterprises
Kumar Sales Corporation
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .